1.Transcatheter edge-to-edge repair using MitraClipTM G4 for severe mitral regurgitation in an advanced elderly patient with Barlow disease.
Fei LUO ; Jiafeng WANG ; Zhifu GUO ; Yongwen QIN ; Yuan BAI
Journal of Zhejiang University. Medical sciences 2025;54(2):199-203
A 91-year-old male patient was admitted with a history of mitral valve prolapse diagnosed by physical examination ten years prior and recent onset of exertional chest discomfort persisting for over one month. Transthoracic echocardiography showed that the anterior leaflet of mitral valve was thickened and prolapsed with severe regurgitation, and transesophageal echocardiography further confirmed that the anterior and posterior leaflets of mitral valve were prolapsed with massive regurgitation (A1, A2, A3, P1 and P2 were all prolapsed). Thus, the diagnosis of Barlow syndrome was considered. Transcatheter edge-to-edge mitral repair was performed with two MitraClipTM G4 XTWs. After a 10 months follow-up, the patient's cardiac function was significantly improved, and the degree of mitral regurgitation was mild.
Humans
;
Male
;
Aged, 80 and over
;
Mitral Valve Insufficiency/surgery*
;
Mitral Valve Prolapse/diagnostic imaging*
;
Cardiac Catheterization/methods*
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
2.Short-term clinical efficacy of transcatheter edge-to-edge repair for moderate to severe mitral regurgitation.
Yunlong MA ; Ruifeng LI ; Mingjun HE ; Shun WANG ; Xiaozhen ZHUO ; Ke HAN
Journal of Zhejiang University. Medical sciences 2025;54(2):204-212
OBJECTIVES:
To evaluate the short-term clinical efficacy of transcatheter edge-to-edge repair (TEER) in patients with moderate to severe mitral regurgitation.
METHODS:
Clinical data of patients with moderate to severe mitral regurgitation who underwent TEER in the Department of Cardiology, the First Affiliated Hospital of Xi'an Jiaotong University from April 2021 to May 2024, were retrospectively analyzed, including preoperative baseline clinical and echocardiography data, intraoperative data and 6-month postoperative follow-up data.
RESULTS:
A total of 67 patients' (47 males and 20 females) data were included, of whom 62 completed 6-month follow-up. The immediately postoperative success rate was 88.1% (59/67), and 83.9% (52/62) patients exhibited mitral regurgitation ≤2+ at 6 months postoperatively, showing significant improvement compared with preoperative (P<0.05). The proportion of patients with mitral regurgitation ≤2+ at 6 months was significantly higher in the degenerative mitral regurgitation (DMR) group than that in the functional mitral regurgitation (FMR) group (P<0.05). The mean mitral valve gradient (MVG) in DMR group was increased from (3.1±1.2) mmHg (1 mmHg=0.133 kPa) to (3.7±1.2) mmHg 6 months after operation (P<0.05), while there was no significant change in FMR group (P>0.05). Compared with those before operation, the N-terminal pro-B-type natriuretic peptide levels in both FMR and DMR groups were significantly lower at 6 months postoperatively (all P<0.05), and the left atrial volume index and left atrial anteroposterior diameter were also significantly lower (all P<0.05). The left ventricular end-diastolic diameter and left ventricular end-systolic diameter were significantly reduced 6 months after operation in the FMR group (all P<0.05), but no significant changes were observed in the DMR group (all P>0.05). The ejection fraction was not significantly changed before and after operation in both groups (all P>0.05). The mitral regurgitation, tricuspid regurgitant, and pulmonary artery pressure were significantly reduced in both groups at 6 months postoperatively (all P<0.05).
CONCLUSIONS
TEER is effective for moderate to severe mitral regurgitation. The improve-ments in left ventricular remodeling are more pronounced in patients with FMR while the degree of mitral regurgitation is more significant in DMR patients. However, MVG elevation is more common during the follow-up.
Humans
;
Mitral Valve Insufficiency/surgery*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Mitral Valve/surgery*
;
Cardiac Catheterization/methods*
;
Heart Valve Prosthesis Implantation/methods*
;
Adult
;
Follow-Up Studies
3.Efficacy of the transcatheter tricuspid valve replacement for patients with severe tricuspid regurgitation: Lux-Valve versus Lux-Valve Plus.
Yandan SUN ; Liang CAO ; Wei BAI ; Yuxi LI ; Jian YANG ; Guomeng JIANG ; Yang LIU ; Ping JIN ; Liwen LIU ; Xin MENG
Journal of Zhejiang University. Medical sciences 2025;54(2):213-218
OBJECTIVES:
To compare the efficacy of transcatheter tricuspid valve replacement (TTVR) using Lux-Valve and Lux-Valve Plus in patients with severe tricuspid regurgitation.
METHODS:
A total of 28 consecutive patients with severe tricuspid regurgitation who underwent TTVR with Lux-Valve (n=14) or Lux-Valve Plus (n=14) in the First Affiliated Hospital of the Air Force Medical University from August 2019 to November 2023 were enrolled. Transthoracic echocardiography was performed in all patients before and 6 months after the TTVR. The ultrasound indexes were compared before and 6 months after the TTVR in all patients and between Lux-Valve and Lux-Valve Plus groups.
RESULTS:
Compared with the Lux-Valve group, the Lux-Valve Plus group showed significantly reduced intraoperative bleeding and shorter postoperative hospital stays (both P<0.05). Six months after the TTVR, none of the patients exhibited more than a mild tricuspid valve regurgitation, and none of the patients had moderate or above perivalvular leakage except for one patient in the Lux-Valve Plus group who had a separation of the clamping member from the anterior tricuspid leaflet. The incidence of perivalvular leakage was significantly lower in the Lux-Valve Plus group (14.29%, 2/14) than in the Lux-Valve group (64.29%, 9/14, P<0.05). At 6 months after operation, the right chamber volume and right ventricle middle transverse diameter were reduced (both P<0.05); the peak blood flow velocity across the tricuspid valve, peak pressure gradient across the tricuspid valve, mean blood flow velocity of tricuspid valve, mean pressure gradient across the tricuspid valve and velocity time integral were increased in both groups (all P<0.05).Compared with the Lux-Valve group, the Lux-Valve Plus group showed higher left ventricular ejection fraction at 6 months postoperatively (P<0.05), while the rest of the indicators were not statistically different (all P>0.05).
CONCLUSIONS
The efficacy of using Lux-Valve and Lux-Valve Plus for TTVR in patients with severe tricuspid regurgitation is comparable. Six months after the TTVR, the right side of the heart has undergone reverse remodeling.While Lux-Valve Plus offers greater minimally invasive benefits, valve selection should consider device-specific characteristics and differences in individual patients.
Humans
;
Tricuspid Valve Insufficiency/surgery*
;
Male
;
Female
;
Heart Valve Prosthesis Implantation/methods*
;
Middle Aged
;
Aged
;
Tricuspid Valve/surgery*
;
Heart Valve Prosthesis
;
Treatment Outcome
;
Echocardiography
;
Adult
;
Cardiac Catheterization/methods*
4.Transesophageal echocardiography assessment of mitral valve for patients with atrial septal defects undergoing surgical repair.
Yuxi LI ; Xin MENG ; Wei BAI ; Liang CAO ; Guomeng JIANG ; Jianlong YANG ; Xuezeng XU ; Liwen LIU
Journal of Zhejiang University. Medical sciences 2025;54(2):191-198
OBJECTIVES:
To investigate the application of transesophageal echocar-diography assessment for mitral valve in patients with atrial septal defects undergoing repair surgery.
METHODS:
The study group comprised of thirty-two adult patients with atrial septal defect who underwent thoracoscopic repair surgery at the First Affiliated Hospital of the Air Force Medical University from March to September 2022. Two-dimensional and real-time three-dimensional transesophageal ultrasonography of the mitral valve were performed after anesthesia. The parameters of the mitral valve structure at the late diastolic and late systolic stages were recorded, including anteroposterior and left-right annular diameters, anterior and posterior valves lengths, the vertical distance from the coaptation point of leaflet zone 2 during systole to the annular plane (mitral valve coaptation depth) and mitral valve coaptation length. Data from 32 patients with normal intracardiac structure and no mitral valve regurgitation (control group) were also collected and compared with those of the study group. Concurrent mitral valvoplasty was performed during the atrial septal defect repair surgery for 7 patients with significant mitral valve structural abnormalities and 2 patients with significantly increased mitral regurgitation after cardiac resuscitation. The study group was followed up with transthoracic echocardiography for 2 years postoperatively.
RESULTS:
In the study group, 26 (81.3%) patients had varying degrees of mitral valve morphological abnormalities. Among them, 10 (31.3%) patients had short mitral valve coaptation length or depth, 12 (37.5%) patients had closure point malposition, and 4 (12.5%) patients had different bulge of anterior and posterior leaflets. Compared with the control group, the study group had significantly smaller systolic and diastolic mitral left-right annular diameter, mitral posterior valves lengths, mitral coaptation length or depth (all P<0.05), a higher pulmonary systemic flow ratio (P<0.01), and a lower maximum blood flow velocity across the mitral valve (P<0.05). After 2 years of follow-up, among the 9 patients who underwent concurrent mitral valvoplasty, the mitral valve maintained no or little regurgitation, and the average mitral valve pressure difference was less than 5 mmHg (1 mmHg=0.133 kPa). Among the 23 patients without concurrent mitral valvoplasty, 2 patients had moderate regurgitation 1 year after surgery, with a pulmonary/systemic flow ratio larger than 2.8.
CONCLUSIONS
Patients with large atrial septal defects often have abnormal mitral valve structure. Therefore transesophageal echocardiography is recommended for mitral valve assessment during the surgery. If significant mitral valve structural abnormalities are detected, concurrent mitral valvoplasty is recommended.
Humans
;
Heart Septal Defects, Atrial/diagnostic imaging*
;
Echocardiography, Transesophageal/methods*
;
Mitral Valve/surgery*
;
Adult
;
Female
;
Male
;
Middle Aged
;
Mitral Valve Insufficiency/diagnostic imaging*
5.Short-term outcomes of transcatheter pulmonary valve replacement with Venus-P valve in patients with moderate-to-severe pulmonary regurgitation and right ventricular systolic dysfunction.
Haiyue XIE ; Wenhao ZHU ; Zhiyuan XIA ; Gejun ZHANG
Journal of Zhejiang University. Medical sciences 2025;54(3):390-398
OBJECTIVES:
To evaluate the short-term outcomes of transcatheter pulmonary valve replacement (TPVR) using the Venus-P valve in patients with moderate-to-severe pulmonary regurgitation and right ventricular systolic dysfunction (RVSD) following surgical repair of complex congenital heart disease.
METHODS:
A retrospective analysis was conducted on patients undergoing Venus-P valve implantation (TPVR group, n=28) or surgical pulmonary valve replacement (SPVR group, n=19) at Fuwai Hospital between February 2014 and February 2024. All patients had moderate-to-severe pulmonary regurgitation with right ventricular ejection fraction less than 45% preoperatively. Postoperative pulmonary valve function and ventricular parameters were assessed at discharge and during a 6-month follow-up.
RESULTS:
All procedures were successfully completed with no early mortality. At 6 months, the TPVR group demonstrated significantly lower pulmonary valve transvalvular pressure gradients compared to the SPVR group (P<0.05). Both groups exhibited significant improvements from baseline in New York Heart Association (NYHA) functional class, biventricular ejection fractions, and right ventricular end-diastolic volume index (all P<0.05). The reduction in right ventricular end-diastolic diameter differed between the two groups (P<0.01). However, multivariable analysis revealed no association between this difference and surgical approach (β=4.4, P>0.05). In the TPVR group, QRS duration was significantly shortened postoperatively (P<0.01), with improvements in left ventricular end-diastolic volume index and cardiac index (both P<0.01), but these improvements did not differ significantly from the SPVR group (all P>0.05). During the follow-up, one patient in each group developed infective endocarditis within 1-month post-procedure; both were successfully treated with antibiotics. No other major complications were observed.
CONCLUSIONS
For patients with moderate-to-severe pulmonary regurgitation and RVSD, TPVR using the Venus-P valve effectively improves short-term pulmonary valve function and ventricular performance with a favorable safety profile, demonstrating potential as a minimally invasive alternative to SPVR .
Humans
;
Pulmonary Valve Insufficiency/surgery*
;
Retrospective Studies
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Ventricular Dysfunction, Right/physiopathology*
;
Treatment Outcome
;
Female
;
Male
;
Child
;
Adult
;
Heart Valve Prosthesis
;
Adolescent
;
Cardiac Catheterization/methods*
;
Child, Preschool
6.Clinical efficacy and safety of transcatheter aortic valve replacement for patients with severe pure native aortic regurgitation.
Jiantao CHEN ; Yi ZHANG ; Kangni FENG ; Suiqing HUANG ; Hanri XIAO ; Mengya LIANG ; Zhongkai WU
Journal of Zhejiang University. Medical sciences 2025;54(4):529-540
OBJECTIVES:
To evaluate the early clinical efficacy and safety of trans-catheter aortic valve replacement (TAVR) for patients with severe pure native aortic regurgitation (PNAR) who are not suitable for conventional surgical aortic valve replace-ment.
METHODS:
A retrospective analysis was conducted on 48 patients with PNAR who underwent TAVR at the Department of Cardiac Surgery, the First Affiliated Hospital of Sun Yat-sen University between March 2019 and February 2025. These included 25 cases with transfemoral approach (TF-TAVR group) and 23 cases with transapical approach (TA-TAVR group). Efficacy and safety were assessed by analyzing baseline characteristics, all-cause mortality, and procedure-related complications.
RESULTS:
Compared with the TA-TAVR group, the TF-TAVR group exhibited significantly smaller aortic annulus circumference and diameter, left ventricular outflow tract circumference and diameter, diameters of the left, right, and non-coronary sinuses, and sinotubular junction (STJ) diameter, along with a shorter distance from the STJ to the aortic annular plane ring plane, a smaller annulus angle (all P<0.05). Additionally, the TF-TAVR group showed a deeper prosthesis implantation depth relative to the aortic annular plane (P<0.01). The overall technical success rate was 91.67%, and the device success rate was 83.33%. Post-TAVR, both groups demonstrated significant improvement in left ventricular end-diastolic diameter (both P<0.05), while only the TA-TAVR group showed significant reduction in left ventricular end-systolic diameter (P<0.05). For primary outcomes, in-hospital mortality occurred in 2 patients (4.17%). No additional deaths were reported at 60 or 90 d after surgery. During 90-180 d after surgery, one patient in the TF-TAVR group died of sudden cardiac death, and one in the TA-TAVR group died of gastroin-testinal bleeding. During 180 d-1 year after surgery, one patient in the TF-TAVR group died of low cardiac output syndrome. No statistically significant differences were observed in 1-year Kaplan-Meier survival curves between the two groups (P>0.05). No conduction block events occurred in TA-TAVR group during hospitalization or 1-year follow-up, while high-grade atrioventricular block, left bundle branch block, permanent pacemaker implantation occurred in TF-TAVR group during hospitalization (12.00%, 4.00%, and 12.00%, respectively).
CONCLUSIONS
TAVR demonstrates high feasibility and acceptable safety for severe PNAR patients who are not suitable for conventional SAVR. Both TF-TAVR and TA-TAVR show comparable early postoperative efficacy and safety profiles.
Humans
;
Transcatheter Aortic Valve Replacement/adverse effects*
;
Aortic Valve Insufficiency/surgery*
;
Retrospective Studies
;
Male
;
Female
;
Aged
;
Treatment Outcome
;
Aortic Valve/surgery*
;
Aged, 80 and over
;
Heart Valve Prosthesis
7.Valve-in-valve transcatheter mitral valve replacement with SAPIEN 3 valve for bioprosthetic mitral valve failure: one-year outcomes in 26 patients.
Zechao RAN ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Tingqian CAO ; Siyu HE ; Xiaoting LI ; Yingqiang GUO
Journal of Zhejiang University. Medical sciences 2025;54(5):668-675
OBJECTIVES:
To evaluate the one-year outcomes of valve-in-valve transcatheter mitral valve replacement (ViV-TMVR) using SAPIEN 3 valve for treating mitral bioprosthetic valve failure.
METHODS:
A retrospective analysis was conducted on 26 patients with mitral bioprosthetic valve failure who underwent ViV-TMVR at West China Hospital, Sichuan University, between November 2022 and July 2024. The age of patients was 71.5 (64.5, 74.5) years, and 69.2% were female. Bioprosthetic valve failure occurred at (9.7±3.7) years after initial surgical implantation, with the most common failure mode being mixed stenosis and regurgitation (53.8%). The SAPIEN 3 valve was implanted via either a transseptal or transapical approach. Echocardiography was performed preoperatively, immediately post-procedure, and at 1 month, 6 months, and 1 year post-procedure. Outcomes included all-cause mortality, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 score, and postoperative complications.
RESULTS:
The procedure was performed via the transseptal approach in 21 patients (80.8%) and the transapical approach in 5 patients (19.2%). All procedures were technically successful. No paravalvular leakage was observed immediately post-procedure, and mitral valve hemodynamics improved significantly. At the 1-year follow-up, 2 patients had died. Two patients (8.3% of survivors) were of NYHA functional class Ⅲ, and KCCQ-12 score improved to (88.4±14.6) points (both P<0.01). Echocardio-graphy at 1 year postoperatively showed significant reductions in peak mitral valve velocity [to (2.29±0.32) m/s] and mean transvalvular pressure gradient [to (9.5±3.5) mmHg, 1 mmHg=0.133 kPa] compared to baseline (both P<0.05). No moderate or severe mitral regurgitation or paravalvular leakage was observed. The proportion of patients with moderate-to-severe pulmonary hypertension decreased from 65.4% preoperatively to 13.0% at 1 year (P<0.05).
CONCLUSIONS
ViV-TMVR with the SAPIEN 3 valve for mitral biopro-sthetic valve failure is associated with high procedural success, significantly improved valve hemodynamics of the mitral value, alleviation of pulmonary hypertension, enhanced quality of life, and a low rate of complications at 1 year after the operation.
Humans
;
Female
;
Male
;
Retrospective Studies
;
Aged
;
Bioprosthesis
;
Heart Valve Prosthesis
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Middle Aged
;
Prosthesis Failure
;
Treatment Outcome
;
Mitral Valve Insufficiency/surgery*
8.Traditional methods and artificial intelligence: current status, challenges, and future directions of risk assessment models for patients undergoing extracorporeal membrane oxygenation.
Zhaojie LIN ; Lu LU ; Menghao FANG ; Yanqing LIU ; Jifeng XING ; Haojun FAN
Chinese Critical Care Medicine 2025;37(10):893-900
Extracorporeal membrane oxygenation (ECMO) is primarily used in clinical practice to provide continuous extracorporeal respiratory and circulatory support for patients with severe heart and lung failure, thereby sustaining life. It is a key technology for managing severe heart failure and respiratory failure that are difficult to control. With the accumulation of clinical experience in ECMO for circulatory and/or respiratory support, as well as advancements in biomedical engineering technology, more portable and stable ECMO devices have been introduced into clinical use, benefiting an increasing number of critically ill patients. Although ECMO technology has become relatively mature, the timing of ECMO initiation, management of sudden complications, and monitoring and early warning of physiological indicators are critical factors that greatly affect the therapeutic outcomes of ECMO. This article reviews traditional methods and artificial intelligence techniques used in risk assessment related to ECMO, including the latest achievements and research hotspots. Additionally, it discusses future trends in ECMO risk management, focusing on six key areas: multi-center and prospective studies, external validation and standardization of model performance, long-term prognosis considerations, integration of innovative technologies, enhancing model interpretability, and economic cost-effectiveness analysis. This provides a reference for future researchers to build models and explore new research directions.
Extracorporeal Membrane Oxygenation
;
Humans
;
Artificial Intelligence
;
Risk Assessment
;
Respiratory Insufficiency/therapy*
;
Heart Failure/therapy*
9.In Vitro Hydrodynamic Performance Evaluation of Valve Repair System.
Liang CAI ; Yibin LI ; Shiwen LYU
Chinese Journal of Medical Instrumentation 2024;48(6):603-606
OBJECTIVE:
To meet the treatment requirements for mitral regurgitation disease, this study designed a novel valve repair system and evaluated its hydrodynamic performance.
METHODS:
A mitral regurgitation model was created. The valve repair system was loaded onto the regurgitation model, and pulsatile flow tests and steady backflow leakage tests were conducted.
RESULTS:
The pulsatile flow test results indicated that the percentage of reflux after product implantation was lower than that before implantation under different concentric outputs and reverse pressures. The average cross-valve pressure difference after implantation was less than 5 mmHg. The steady backflow leakage test results showed that as the reverse pressure increased, the leakage amount of the valve repair system after implantation also increased.
CONCLUSION
The developed valve repair system exhibits excellent hydrodynamic performance, suggesting the feasibility of its application in the treatment of clinical mitral regurgitation.
Hydrodynamics
;
Mitral Valve Insufficiency/surgery*
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis
;
Pulsatile Flow
;
Heart Valve Prosthesis Implantation
10.The clinical impact of tricuspid regurgitation in patients with a biatrial orthotopic heart transplant.
Kevin M VEEN ; Grigorios PAPAGEORGIOU ; Casper F ZIJDERHAND ; Mostafa M MOKHLES ; Jasper J BRUGTS ; Olivier C MANINTVELD ; Alina A CONSTANTINESCU ; Jos A BEKKERS ; Johanna J M TAKKENBERG ; Ad J J C BOGERS ; Kadir CALISKAN
Frontiers of Medicine 2023;17(3):527-533
In this study, we aim to elucidate the clinical impact and long-term course of tricuspid regurgitation (TR), taking into account its dynamic nature, after biatrial orthotopic heart transplant (OHT). All consecutive adult patients undergoing biatrial OHT (1984-2017) with an available follow-up echocardiogram were included. Mixed-models were used to model the evolution of TR. The mixed-model was inserted into a Cox model in order to address the association of the dynamic TR with mortality. In total, 572 patients were included (median age: 50 years, males: 74.9%). Approximately 32% of patients had moderate-to-severe TR immediately after surgery. However, this declined to 11% on 5 years and 9% on 10 years after surgery, adjusted for survival bias. Pre-implant mechanical support was associated with less TR during follow-up, whereas concurrent LV dysfunction was significantly associated with more TR during follow-up. Survival at 1, 5, 10, 20 years was 97% ± 1%, 88% ± 1%, 66% ± 2% and 23% ± 2%, respectively. The presence of moderate-to-severe TR during follow-up was associated with higher mortality (HR: 1.07, 95% CI (1.02-1.12), p = 0.006). The course of TR was positively correlated with the course of creatinine (R = 0.45). TR during follow-up is significantly associated with higher mortality and worse renal function. Nevertheless, probability of TR is the highest immediately after OHT and decreases thereafter. Therefore, it may be reasonable to refrain from surgical intervention for TR during earlier phase after OHT.
Male
;
Adult
;
Humans
;
Middle Aged
;
Tricuspid Valve Insufficiency/diagnostic imaging*
;
Heart Transplantation
;
Echocardiography
;
Ventricular Dysfunction, Left
;
Retrospective Studies
;
Treatment Outcome

Result Analysis
Print
Save
E-mail