1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Correlation between right atrial function parameters and prognosis in patients with chronic obstructive pulmonary disease complicated with pulmonary hypertension
Wanting GUO ; Ying LI ; Hailing LIU ; Xinmei ZHUANG ; Haiyan LI
Chinese Journal of Postgraduates of Medicine 2024;47(2):185-188
Objective:To explore the correlation between right atrial function parameters and prognosis in patients with chronic obstructive pulmonary disease(COPD) complicated with pulmonary hypertension.Methods:Eighty-four patients with COPD combined with pulmonary arterial hypertension treated with bosentan combined with milrinone admitted to the First Affiliated Hospital of Xinjiang Medical University during the period of February 2020 to June 2022 were selected as the study subjects, and they were divided into the effective group (63 cases) and the ineffective group (21 cases) according to the treatment effect. Right cardiac function parameters were measured by Philips iE33 color ultrasonography before treatment and 72 h after treatment. Logistic regression was used to analyze the risk factors affecting the treatment outcome of patients, and receiver operating characteristics (ROC) curve was used to analyze the predictive value of right atrial function parameters in the poor prognosis of patients with COPD complicated with pulmonary hypertension.Results:The main pulmonary artery diameter (MPA), right ventricular base transverse diameter (RVd1), right ventricular middle transverse diameter (RVd2), right atrial diameter (RAd) and right ventricular free wall thickness (RVWT) in the effective group were lower than those in the ineffective group: (2.65 ± 0.23) cm vs. (2.90 ± 0.44) cm, (3.46 ± 0.43) cm vs. (3.76 ± 0.72) cm, (3.48 ± 0.42) cm vs. (3.88 ± 0.69) cm, (3.53 ± 0.81) cm vs. (4.03 ± 1.20) cm, (0.63 ± 0.12) cm vs. (0.72 ± 0.21) cm; end-diastolic to end-systolic tricuspid ring displacement (TAPSE) was higher than that in the ineffective group: (2.08 ± 0.32) cm vs. (1.82 ± 0.46) cm, there were statistical differences( P<0.05). Logistic regression analysis showed that RVd1 increased ( OR = 3.717, P<0.05), RVd2 increased ( OR = 2.162, P<0.05), RAd increased ( OR = 2.838, P<0.05) and TAPSE reduction ( OR = 1.704, P<0.05) were risk factors for treatment failure in patients. The results of ROC curve showed that the area under the curve of RVd1, RVd2, RAd, TAPSE in predicting the therapeutic effect of COPD patients with pulmonary hypertension were 0.820, 0.831, 0.872, 0.909, respectively. Conclusions:The independent influencing factors of ineffective patients with COPD combined with pulmonary arterial hypertension treated with bosentan combined with milrinone are the increase of structural parameters of the right heart and the decrease of systolic function parameters. The therapeutic effect of patients can be evaluated clinically according to the level of each parameter.
5.Interpretation of group standards for nursing care of patients with infusion of vasoactive agents
Yanyan YU ; Qingyin LI ; Xueqin GAO ; Xiaofeng KANG ; Zhuqing ZHONG ; Hongjun ZHANG ; Haiyan ZHANG ; Siqing DING ; Shumei ZHUANG ; Zhenjuan ZHAO ; Yaping LIU
Chinese Journal of Nursing 2024;59(20):2444-2446
0n December 31,2021,the Chinese Nursing Association released the group standard"nursing care of patients with infusion of vasoactive agents(T/CNAS 22-2021)",which outlines the fundamental requirements for intravenous infusion of vasoactive drugs and standardizes the evaluation,administration,and monitoring.This article provides an interpretation of the key parts and sections of the standard to ensure nursing safety during the administration of vasoactive drugs,aiming to reduce complications.Additionally,it serves as a crucial reference for nurses during the administration of the medication.
6.Study on the effect of PBL,TBL and CP teaching methods combined on standardized training of periodontology residents
Deshu ZHUANG ; Liangjia BI ; Haiyan LU ; Lili GAO
STOMATOLOGY 2024;44(7):536-539
Objective To assess the effectiveness of combining problem-based learning(PBL),team-based learning(TBL),and clinical pathway(CP)in standardized training of periodontology residents.Methods A total of 48 residents who were transferred to the Department of Periodontology at the Fourth Affiliated Hospital of Harbin Medical University from January to October 2023 were ran-domly assigned to either the traditional teaching group or the PBL,TBL,and CP combined teaching group,with 24 participants in each group.The traditional teaching group followed conventional teaching methods,while the PBL,TBL,and CP combined teaching group utilized a combination of these three methods.Prior to completing their rotation,both groups underwent professional assessments as well as surveys on satisfaction with standardized training and self-evaluation.Results The professional examination scores ofcombined teaching group were significantly higher than those of the traditional teaching method group(P<0.05).Both groups expressed satisfac-tion with standardized training and demonstrated proficiency in diagnosing and treating periodontitis through instruction;no statistically significant difference was observed between them(P>0.05).However,compared to the traditional teaching group,students in the PBL,TBL,and CP combined teaching group showed significant improvements in doctor-patient communication skills,active informa-tion retrieval abilities,learning interest levels,team discussions,and clinical logical thinking abilities(P<0.05).Conclusion Im-plementing a combination of PBL,TBL,and CP during standardized training of periodontology residents can enhance students'profes-sional examination scores and self-evaluation results,which promotes educational reform development by providing an objective basis.
7.Reliability of nailfold videocapillaroscopy evaluation in patients with Raynaud's phenomenon
Chunxiao WANG ; Haiyan XU ; Xiaoli JIANG ; Feifei JIANG ; Yue ZHUANG
Journal of China Medical University 2024;53(12):1107-1110,1117
Objective To evaluate the reliability of nailfold videocapillaroscopy (NVC) in patients with Raynaud's phenomenon (RP). Methods A total of 302 participants with RP at Sichuan Provincial People's Hospital were examined using NVC with a 200× magni-fication to acquire images from six digits (the second,third,and fourth fingers of both hands) of patients with RP,and 3805 NVC images were obtained. Five rheumatologists assessed the obtained NVC images separately,using the European League against Rheumatism Study Group on Microcirculation in Rheumatic Diseases standardized capillaroscopy evaluation chart. Two months later,the same rheumatolo-gists re-evaluated one-fifth of the randomly selected patients. The intraclass correlation coefficient was used to analyze the inter-and intra-observer reliability. Results When evaluating NVC images,the inter-observer and intra-observer reliabilities of the five researchers were good,and the intraclass correlation coefficient values were 0.724-0.930 (P<0.001) and 0.841-0.939 (P<0.001),respectively. In the subgroup analysis of different patterns of NVC images,four out of five investigators showed moderate to good inter-observer agreement,and only one beginner had poor agreement in identifying normal,non-specific,and early patterns. Conclusion Rheumatologists with dif-ferent experience levels showed good agreement in evaluating NVC images in patients with RP,suggesting that NVC examination has good reliability and reproducibility.
8.Reliability of nailfold videocapillaroscopy evaluation in patients with Raynaud's phenomenon
Chunxiao WANG ; Haiyan XU ; Xiaoli JIANG ; Feifei JIANG ; Yue ZHUANG
Journal of China Medical University 2024;53(12):1107-1110,1117
Objective To evaluate the reliability of nailfold videocapillaroscopy (NVC) in patients with Raynaud's phenomenon (RP). Methods A total of 302 participants with RP at Sichuan Provincial People's Hospital were examined using NVC with a 200× magni-fication to acquire images from six digits (the second,third,and fourth fingers of both hands) of patients with RP,and 3805 NVC images were obtained. Five rheumatologists assessed the obtained NVC images separately,using the European League against Rheumatism Study Group on Microcirculation in Rheumatic Diseases standardized capillaroscopy evaluation chart. Two months later,the same rheumatolo-gists re-evaluated one-fifth of the randomly selected patients. The intraclass correlation coefficient was used to analyze the inter-and intra-observer reliability. Results When evaluating NVC images,the inter-observer and intra-observer reliabilities of the five researchers were good,and the intraclass correlation coefficient values were 0.724-0.930 (P<0.001) and 0.841-0.939 (P<0.001),respectively. In the subgroup analysis of different patterns of NVC images,four out of five investigators showed moderate to good inter-observer agreement,and only one beginner had poor agreement in identifying normal,non-specific,and early patterns. Conclusion Rheumatologists with dif-ferent experience levels showed good agreement in evaluating NVC images in patients with RP,suggesting that NVC examination has good reliability and reproducibility.
9.Determination of eight active components in Buyang Huanwu Decoction by HPLC-DAD-ELSD
Mingcong LI ; Yixin DONG ; Yuming ZHUANG ; Ping YU ; Hui ZHAO ; Haiyan ZOU
International Journal of Traditional Chinese Medicine 2023;45(6):719-724
Objective:To establish an HPLC-DAD-ELSD method for the simultaneous determination of eight main active components in Buyang Huanwu Decoction, including hydroxysafflor yellow A, paeoniflorin, calycosin glycoside, ferulic acid, ononin, calycosin, fermononetin and astragaloside.Methods:Agilent Eclipse XDB-C18 column (250 mm×4.6 mm, 5 μm) was used with acetonitrile-0.1% formic acid as the mobile phase. The flow rate was 1.0 ml/min; the column temperature was 30 ℃; the detection wavelengths were 230 nm (paeoniflorin), 254 nm (calycosin glycoside, ononin, calycosin, fermononetin), 322 nm (ferulic acid) and 403 nm (hydroxysafflor yellow A); the drift tube temperature of the evaporative light scattering detector was 60 ℃; the carrier gas flow rate was 1.6 L/min.Results:Under these conditions, the separation of hydroxysafflor yellow A, paeoniflorin, calycosin glycoside, ferulic acid, ononin, calycosin, fermononetin and astragaloside was good, and the linear relationship was in line with the requirements ( r=0.994 0-0.999 9). The average recovery was 97.8% - 101.4% ( RSD was 1.28% - 3.70%). Conclusion:The method is simple, stable and reproducible, and can be used for the quality control of Buyang Huanwu Decoction.
10.Allogeneic hematopoietic stem cell transplantation for high-risk multiple myeloma patients: a clinical analysis
Yan ZHUANG ; Haiyan HE ; Jing LU ; Lu LI ; Hua JIANG ; Weijun FU ; Jian HOU ; Juan DU
Journal of Leukemia & Lymphoma 2022;31(4):213-217
Objective:To investigate the effects of allogeneic hematopoietic stem cell transplantation (allo-HSCT) in treatment of high-risk multiple myeloma (MM) patients and its influencing factors of the prognosis.Methods:The clinical data of 44 high-risk MM patients treated with allo-HSCT in Changzheng Hospital Affiliated of Naval Military Medical University from April 2003 to March 2017 were retrospectively analyzed. The overall response rate (ORR), relapse rate, non-relapse-related death (NRM) rate, graft-versus-host disease (GVHD) incidence of patients were also analyzed. Kaplan-Meier was used to analyze the overall survival (OS) rate and progression-free survival (PFS) rate after transplantation. Cox proportional hazard model was used to make regression analysis of the factors affecting the prognosis.Results:Among 44 patients, 38 cases could be evaluated for efficacy after transplantation. The median follow-up time was 111 months (0-216) months, 22 cases survived, 22 cases died, 21 cases relapsed. Before transplantation, complete remission (CR) rate was 29.5%(13/44), very good partial remission(VGPR) rate was 45.5%(20/44), partial remission (PR) rate was 22.7% (10/44), stable disease (SD) rate was 2.3% (1/44); After transplantation, CR rate was 71.7%(27/38), VGPR rate was 13.2% (5/38), PR rate was 13.2% (5/38), the progression of the disease (PD) rate 2.6% (1/38). The 5-year OS rate and PFS rate was 51.8% and 47.8%, the 10-year OS rate and PFS rate was 51.3% and 43.1%, respectively; the 5-year and 10-year cumulative disease relapse rate was 38.6% and 45.4%, the 5-year cumulative NRM rate was 25.0%. Acute GVHD rate was 38.6% (17/44) and grade 3-4 acute GVHD rate was 6.8% (3/44); chronic GVHD rate was 27.3% (12/44). Cox univariate and multivariate analysis showed that the use of bortezomib before transplantation ( HR = 3.461, 95% CI 1.211-9.880, P = 0.020) and post-transplant infection ( HR = 0.283, 95% CI 0.098-0.819, P = 0.020) were independent factors affecting OS after transplantation. Conclusions:Allo-HSCT can overcome the high-risk factors of MM and is worth to try for high-risk MM patients. The use of bortezomib before transplantation and post-transplant infection can be important factors affecting OS after transplantation.

Result Analysis
Print
Save
E-mail