1.The Potential Role of Immune Checkpoint Molecules in the Pathogenesis of Autoimmune Hepatitis and in Targeted Therapy
Haixia LI ; Aiping TIAN ; Miao XUE ; Ziyi LI ; Xiaorong MAO
Medical Journal of Peking Union Medical College Hospital 2026;17(2):512-518
Autoimmune hepatitis (AIH) is a chronic, immune-mediated liver injury of unknown etiology. The onset of this disease involves the activation and recruitment of diverse immune and non-immune cells, which in turn trigger hepatic damage. Immune checkpoint molecules (ICM) are expressed on the surface of multiple cell types. By regulating cellular functional states, they help limit the intensity and duration of immune responses, thereby preventing excessive inflammation and tissue damage, and maintaining immune homeostasis. In AIH, however, this natural "braking" mechanism is impaired, leading to aberrant activation of both immune and non-immune cells and the breakdown of immune homeostasis. Consequently, ICM are likely to play a critical role in the pathogenesis of AIH. A deeper understanding of the function of ICM in AIH not onlyadvances our insight into the disease mechanism, but also suggests that targeting these molecules may represent a promising therapeutic strategy for the treatment of AIH.
2.Clinical application of KASP-based RHCE genotyping in RhD-positive patients
Xiaoyu LIAN ; Mengdan LI ; Xiaoyu GUAN ; Li TIAN ; Chenying WANG ; Di WU ; Tianqiong LUO ; Xiaolin DU ; Xin JI ; Haixia XU ; Jue WANG ; Ling LI ; Zhong LIU
Chinese Journal of Blood Transfusion 2026;39(5):596-602
Objective: To develop a RHCE genotyping assay based on kompetitive allele-specific PCR (KASP) and assess its clinical accuracy for RhCE blood group determination. Methods: KASP primers were designed to interrogate three RHCE loci: the 109 bp insertion/deletion in intron 2, c. 307T>C, and c. 676C>G. A total of 1 194 RhD-positive inpatients from Chengdu were typed by both KASP genotyping and manual tube serology. Discordant samples (n=10) were retested by both methods and further resolved by Sanger sequencing. An additional 377 cases were tested for the c. 48C>G locus to evaluate the predictive accuracy of individual loci and combined locus testing for RhC antigen. Results: Genotyping concordance with serology was 100.0% for both the c. 676C>G locus (RhE/Rhe) and the c. 307T>C locus (Rhc). For RhC prediction using the 109 bp insertion, overall accuracy was 99.7% (1 191/1 194); the 3 discordant cases were confirmed by Sanger sequencing to be false negatives attributable to 109 bp deletion in intron 2. Testing the c. 48C>G allele for RhC prediction yielded 7 false positives, with an accuracy of 98.1% (370/377). RhC antigen status was determined by combining the 109 bp insertion and the c. 48C allele. After excluding 10 samples with inconsistent results between the two loci, the accuracy reached 100% in the remaining 367 samples. When both loci were applied in combination, accuracy reached 100% in the 367 cases with concordant results. Among the 1 194 patients, CCee (45.8%) and CcEe (31.7%) were the most common RhCE phenotypes. The e antigen had the highest positivity rate (92.2%), and the Ce haplotype was the most frequent (66.9%). Conclusion: The KASP-based RHCE genotyping method achieves high accuracy for clinical RhCE typing. Combining the 109 bp insertion/deletion with the c. 48C allele significantly improves RhC antigen prediction compared with either locus alone. This method was applied to RhCE genotyping of 1 194 RhD-positive inpatients in Chengdu, providing local RhCE phenotype and haplotype distribution data to support RhCE-matched transfusion practice.
3.Application and management status of automated endoscope reprocessors in 292 medical institutions
Jin ZHEN ; Liuji CHEN ; Haixia LIU ; Jiuhong MA ; Xianhuang LI ; Xi HUANG
Chinese Journal of Infection Control 2025;24(9):1278-1285
Objective To understand the current status of application,management,and maintenance of automa-ted endoscope reprocessors(AERs)in China.Methods A questionnaire survey was conducted using convenience sampling method on the application,management,maintenance,and monitoring of AERs,as well as personnel training in digestive endoscopy centers of 292 medical institutions(MIs).Results A total of 316 questionnaires were distributed,and 292 were available,with an effective response rate of 92.41%.Among the 292 MIs,198(67.81%)were equipped with AERs,with equipment rates of 75.11%in tertiary MIs and 41.27%in secondary MIs.88.38%of MIs performed manual cleaning before placing endoscopes into AERs,while 2.02%of MIs still didn't perform this step,mainly in tertiary MIs.The most common problems in the application of AERs were the detachment or damage of connecting pipes(83.33%),followed by disinfectant leakage of AERs(43.94%),mal-function of control panel(43.94%),and failure or poor water flow of AER pipeline(42.93%).92.42%of MIs regularly disinfected AERs,72.73%of MIs regularly replaced AER air filters,and 80.30%of MIs regularly re-placed AER water filters.96.46%of MIs monitored the concentration of disinfectants before daily application of AERs,87.88%of MIs regularly monitored the final rinse water of AERs,and 96.97%of MIs provided professio-nal training for new employees to use AERs for the first time.Conclusion The equipping rate of AERs at all levels of MIs in China still needs to be improved.Most MIs are able to monitor and maintain AERs well,but there are still many problems in the application process.Due to the large volume of endoscopic diagnosis and treatment as well as insufficient execution rate of manual cleaning in tertiary MIs,it is necessary to optimize workflow and strengthen training.Secondary MIs face challenges such as equipment shortages and low monitoring execution rates,requiring increased funding and regulatory efforts.It is recommended that manufacturers continuously optimize AER design,MIs establish standardized AER application protocol,and relevant departments improve AER application and ma-nagement standards,in order to improve the quality of endoscopic cleaning and disinfection and ensure patient safety during diagnosis and treatment.
4.Distribution characteristics of infectious respiratory particles in hospital waiting rooms
Haixia ZHANG ; Jianxin MA ; Boyu WAN ; Liyan AI ; Shuyi YANG ; Wenjing LI
Chinese Journal of Infection Control 2025;24(10):1443-1451
Objective To analyze the distribution characteristics of infectious respiratory particles(IRPs)in hospi-tal waiting rooms,and explore the impact of indoor air environmental on the distribution characteristics of bacterial IRPs.Methods In the summer and winter of 2024,nine waiting rooms in non-infectious departments of three ter-tiary hospitals in a district of Beijing were selected for on-site investigation on basic conditions.Concentration and distribution of particle diameter of cultivable bacteria from 36 air specimens collected by the impacting method were analyzed.Cyclone method was employed to collect 36 IRPs specimens.Major respiratory pathogens were analyzed by fluorescence polymerase chain reaction(PCR).Results The median of the total bacterial count in IRPs in the waiting rooms in summer was 1 035 CFU/m3,which was higher than that in winter(295 CFU/m3),with statisti-cally significant difference(P<0.05).The orders of medians of the total bacterial count from IRPs of different types in the waiting rooms in both summer and winter were as follows:emergency department waiting room<re-spiratory department waiting room<pediatric waiting room<general outpatient waiting room.There was no sta-tistically significant difference in the total bacterial count among different waiting rooms(P>0.05).Particle diame-ter of bacterial IRPs in the waiting rooms in summer and winter mainly distributed in the range of<4.7 μm,ac-counting for 73.77%and 69.44%,respectively.The total number of bacteria in IRPs in the waiting rooms was positively correlated with indoor air temperature,relative humidity,PM10,and PM2.5(all P<0.01),while nega-tively correlated with indoor wind speed(all P<0.01).The types of respiratory infectious and non-infectious pathogens detected from IRPs in different types of waiting rooms were different between summer and winter.The pathogens detected in summer were mainly concentrated in respiratory non-infectious pathogens(Escherichia coli,Klebsiella pneumoniae,Staphylococcus aureus).In winter,respiratory infectious pathogens(virus and Mycoplas-ma pneumoniae)were detected.The types of detected pathogens in different types of waiting rooms were different.Non-infectious respiratory pathogens detected from IRPs in winter were mainly Escherichia coli,Klebsiella pneumoniae,and Staphylococcus aureus.Conclusion Particle diameter of bacterial IRPs in the waiting room is mainly<4.7 μm.These particles can enter the lower respiratory tract of human body,and pose potential risk to health.The detection of main infectious and non-infectious respiratory pathogens from IRPs in waiting rooms suggests risk of exposure to infection for patients and healthcare workers.
5.Effect of embryo cryostorage duration on pregnancy and obstetric outcomes in patients undergoing FET assisted reproduction
Haixia CHEN ; Tuo KUANG ; Fang LI ; Jing ZHANG ; Xiaohuan MU ; Yonghuan LYU ; Wenyan TIAN ; Xueru SONG ; Xiaohong BAI
Chinese Journal of Reproduction and Contraception 2025;45(1):59-66
Objective:To investigate the effect of the embryo cryopreservation duration on pregnancy and obstetric outcome.Methods:A retrospective cohort study of 2 662 frozen-thawed embyro tranfer (FET) cycles was conducted in the Reproductive Medicine Center, Department of Obstetrics and Gynecology, Tianjin Medical University General Hospital from January 2016 to December 2020. According to embryo cryopreservation duration, the patients were divided into group A (≤1 year, n=2 115), group B (>1 years and ≤3 years, n=319), group C (>3 years and ≤6 years, n=174), and group D (>6 years, n=54). We used the propensity score matching (PSM) to match the baseline data of oocyte retrieval age of the other three groups according to group D at a ratio of 1∶3. Clinical and obstetric outcomes were compared among the four groups. Multiple logistic regression analysis was used to analyze the effect of oocyte retrieval age, embryo transfer age, the duration of embryo cryopreservation, endometrial preparation scheme, endometrial thickness, the number of transferred embryos and the number of high-quality embryos on pregnancy and live birth outcome. Results:1) Before PSM, there were significant differences in the maternal age at oocyte retrieval and embryo transfer and duration of embryo cryopreservation among the four groups(all P<0.001). 2) After PSM, the baseline characteristics of oocyte retrieval age reached a balance among the four groups. There were no statistical differences in the number of embryos transfer, the number of high-quality embryos, the transferred embryo stage, the endometrial regimen among the groups (all P>0.05). The clinical pregnancy rate [37.04% (20/54)] and the live birth rate [33.33% (18/54)] in group D were lower than those in group A [51.57% (82/159), 40.88% (65/159)], group B [50.00% (65/130), 40.77% (53/130)] and group C [49.59% (61/123), 39.02% (48/123)], but the difference was not statistically significant between the four groups ( P=0.310, P=0.781). There were no statistical differences among the four groups in the ratio of male to female newborns, gestational age, birth weight, preterm delivery rate, low birth weight rate, macrosomia rate, birth defects, and premature repture of membranes (all P>0.05). 3) Multiple logistic regression analysis showed that the number of high-quality embryos transferred affected the clinical pregnancy outcome (before PSM, OR=2.614, 95% CI: 2.168-3.151, P<0.001; after PSM, OR=1.984, 95% CI: 1.406-2.800, P<0.001) and live birth (before PSM, OR=2.708, 95% CI: 2.198-3.336, P<0.001; after PSM, OR=2.122, 95% CI: 1.474-3.053, P<0.001). The duration of embryo cryopreservation does not affect the clinical outcome and live birth (all P>0.05). Conclusion:The duration of embryo cryopreservation does not affect the clinical outcome and live birth, but large sample data are still needed to support this conclusion in the future.
6.Application of optical surface monitoring system in intensity-modulated radiotherapy for thoracic tumors
Haixia YANG ; Menglu SUN ; Xiaosha ZHOU ; Yaxuan HAN ; Baolong REN ; Jianying LI ; Yi LI
The Journal of Practical Medicine 2025;41(9):1345-1351
Objective To evaluate the effect of optical body surface monitoring system(OSMS)in setup of intensity modulated radiotherapy(IMRT)for thoracic tumorsand to analyze its relationship with BMI.Methods Thesetup errors of CBCT and location CT with body membrane and the registration errors of OSMS and first body surface reference image without body membrane were obtained in 49 patients with thoracic tumor who received routine intensity modulated radiotherapy.The paired t-test was used to analyze the difference of registration errors between the two image guidance methods.Pearson′s correlation analysis was used to analyze the correlation between CBCT errors and OSMS errors,and Bland-Altman analysis was employed to evaluatethe agreement of the two errors.The correlation and consistency of the two registration errors in patients with different BMI index were analyzed.PTV external marginsby the two registration methods were calculated using Van Herk formula.Results The OSMS and CBCT groups demonstrated significant differences in setup errors in the ventrodorsal direction(P<0.05),while no significant differences were found in the left-right,head-foot translation directions,or RTN rota-tion directions(P>0.05).Although the two methods showed a significant correlation in setup errors(P<0.05),this correlation was only moderate in the head-foot and left-right directions(r=0.500,0.408),weak in the RTN rotation direction(r=0.339),and very weak in the ventrodorsal direction(r=0.152).The limits of agreement(LOA,95%CI)between the two methods were[-0.45,0.45]cm in the left-right direction,[-0.59,0.57]cm in the head-foot direction,and[-0.48,0.40]cm in the ventrodorsal direction,with(-2.08°~2.19°)in the RTN rotation direction.Different BMI levels influenced the results of the two registration methods,particularly in patients with a BMI of 18.5~23.9 kg/m2.In this group,OSMS and CBCT exhibited a strong correlation in the head-foot direction(r=0.731),a moderate correlation in the left-right direction(r=0.512),and weak correlations in the ventrodorsal and RTN rotation directions(r=0.345,0.267).The absolute difference in setup errors between the two imaging systems was 0.4~0.5 cm/2°.Using CBCT and OSMS image guidance,the margins in the left-right,head-foot,and ventrodorsal directions were[0.5 cm,0.7 cm,0.3 cm]for CBCT,and[0.5 cm,0.7 cm,0.5 cm]for OSMS.Conclusion In chest tumor patients with a BMI of 18.5~23.9 kg/m2,OSMS and CBCT image guidance methods show good correlation in the head-foot and left-right directions,but their limits of agreement exceed the clinically acceptable range.OSMS cannot yet replace CBCT for image guidance in chest tumor intensity-modulated radiotherapy.Further improvements to tumor motion surrogates are necessary to enhance the accuracy of OSMS image guidance.
7.Effect of omalizumab injection combined with compound glycyrrhizin tablets on chronic urticaria with low response to antihistamines
Haixia SHI ; Yuan GUO ; Yanhua LI ; Juping CHEN ; Haochen YUAN ; Yun ZHANG
The Journal of Practical Medicine 2025;41(8):1212-1216
Objective To investigate the effectiveness and safety of combining Omalizumab with compound glycyrrhetinic acid glycoside in the management of chronic urticaria that exhibits poor response to antihistamine therapy.Methods 92 patients with chronic urticaria who were treated with H1 antihistamines and still had symp-toms from February 2022 to February 2024 in the hospital were selected as the study subjects.The study partici-pants were randomly assigned to either the observation group,consisting of 46 cases,or the control group,also comprising 46 cases,using a random number table method.The control group received subcutaneous injection of omalizumab for treatment.The observation group was treated with oral compound glycyrrhizin tablets on the basis of the control group.After 24 weeks of treatment,compare the efficacy,adverse reactions,Urticaria Activity Score over 7 days(UAS7),Dermatology Life Quality Index(DLQI),Immunoglobulin(Ig)E,and High Sensitivity C-reactive protein(hs CRP)between the two groups,and record the recurrence rate.Results After treatment,the UAS7,DLQI,IgE and hs-CRP of both groups of patients decreased compared to before treatment,and the observation group demonstrated lower results compared to the control group(P<0.05).After treatment,the overall effectiveness rate in the observation group exceeded that of the control group(P<0.05),and the recurrence rate was lower than that of the control group(P<0.05).There was no statistically significant difference in the incidence of adverse reactions between the two groups of drugs(P>0.05).Conclusion The combination therapy of omali-zumab and compound glycyrrhetinic acid glycoside in the treatment of chronic urticaria patients with low response to antihistamines helps reduce IgE expression,improve treatment effectiveness,lower recurrence rates,and does not increase adverse drug reactions.
8.Research on the influence of CYP2A6 gene polymorphism on liver function injury in the treatment of hyperthyroidism with methimazole
Zuzhi ZHAO ; Haixia ZHAO ; Pengfei XU ; Yinghao FAN ; Peng SUN ; Suqin ZHANG ; Xinguang QIU ; Jianhua LI
Chinese Journal of Endocrine Surgery 2025;19(4):527-532
Objective:To investigate the influence of cytochrome P450 2A6 (CYP2A6) gene polymorphisms on liver function injury in patients with hyperthyroidism treated with methimazole.Methods:The study selected 90 patients with hyperthyroidism who were treated with methimazole in the Department of Thyroid Surgery at the First Affiliated Hospital of Zhengzhou University from Sept. 2023 to Aug. 2024 as the research subjects. Based on the occurrence of liver injury, they were divided into a liver injury group ( n=36) and a non-liver injury group (n=54). Peripheral blood DNA was extracted from the patients, and the CYP2A6 gene genotypes (rs8192725, rs8192720, and rs28399433) were detected using the polymerase chain reaction (PCR) amplification method. The association between CYP2A6 gene polymorphisms and liver injury induced by methimazole treatment in hyperthyroidism was analyzed. Results:The comparison of genotype distribution frequencies at the rs8192725 locus between the liver injury group and the non-liver injury group showed a statistically significant difference ( P<0.05). The AG and GG genotypes at the rs8192725 locus were protective factors against liver injury in patients with hyperthyroidism (AG vs. AA, OR: 0.21; 95% CI: 0.08-0.57; P<0.05; GG vs. AA, OR: 0.24; 95% CI: 0.06-0.89; P<0.05; AG+GG vs. AA, OR: 0.22; 95% CI: 0.09-0.54; P<0.05). The frequency of the G allele of rs8192725 in the liver injury group was significantly lower than that in the non-liver injury group (G vs. A, OR: 0.36; 95% CI: 0.19-0.70; P<0.05), indicating that it is a protective factor for liver injury in hyperthyroid patients receiving methimazole treatment. Conclusions:The CYP2A6 gene polymorphism at the rs8192725 locus is associated with the occurrence of liver injury in patients with hyperthyroidism treated with methimazole. The G allele may be a protective factor against liver injury in patients with hyperthyroidism, suggesting that individualized treatment plans can be developed based on the patient's genotype.
9.Methodological correlation and efficacy analysis of the detection of hepatitis B virus surface antigen in clinical laboratory
Haixia WANG ; Shulin ZHANG ; Yingying ZHAO ; Yangfan FENG ; Weipeng DU ; Jingyi LIANG ; Jiawei LI
Chinese Journal of Immunology 2025;41(7):1772-1776,1781
Objective:To explore the evaluation and relationship of hepatitis B virus(HBV)surface antigen(HBsAg)in clinical laboratory in different detection systems,further scientifically and reasonably to explain the test results for serving clinical practices.Methods:During the period from June 2021 to July 2022,100 425 specimens of patients with screened,suspected and confirmed HBV infections were collected from the clinical departments(mainly infectious hepatology)of Nanyang Central Hospital.Detection methodology included quantitative(electrochemiluminescence and chemiluminescence),qualitative(gold standard),semi-quantita-tive(ELISA),and highly sensitive HBV-DNA(RT-PCR)methods,and then analyzed the strengths and weaknesses and closeness be-tween each methodology.The relationship between the two Roche HBsAg detection systems was analyzed by correlation analysis.The HBsAg efficacy analysis was validated using Cut/Off value setting and detection limit,which in turn analyzed the distribution of false-positive and false-negative reporting models.Results:Detection results for low-and medium-concentration HBsAg showed a correla-tion between the electrochemical luminescence semi-quantitative method and ELISA method.ELISA method still had advantages in terms of sensitivity and specificity when detecting HBsAg,and there were no significant differences compared to domestic and interna-tional HBsAg quantitative detection systems.Performance validation conducted in accordance with the CNAS-GL038 document showed that the minimum detection limit for HBsAg calculated using the ELISA method in this laboratory was 0.1 U/ml.When the ROC curve Cut/Off value was set to 0.105,the area under the curve was the largest(AUC=0.986).Based on Roche's semi-quantitative electroche-miluminescence detection and patient medical history,in the common reporting model for hepatitis B five-item detection using ELISA method,HBsAg false positives occurred most frequently when HBsAg was positive alone,and HBsAg occurred most frequently in the false positive range when the OD value was less than 0.5.In ELISA method for detecting HBsAg,as the OD value increased from 0.01 to 0.10,the number of false-negative results also increased.Roche Elecsys HBsAg Ⅱ Quant Ⅱ and Elecsys HBsAg Ⅱ testing systems exhibited good linearity under certain conditions,with a ratio of approximately 1/0.18.In Elecsys HBsAg Ⅱ Quant Ⅱ detection sys-tem,the test results of HBsAg samples diluted 400 times were highly consistent with the original test results with a coefficient of deter-mination R2=0.993 8.Conclusion:There was a certain relationship between various detection systems of HBsAg at a suitable concen-tration.The detection of HBsAg by ELISA can meet the needs of clinical detection.
10.Study on the efficacy and safety of Metformin hydrochloride enteric-coated capsules in patients with type 2 diabetes mellitus
Yiming WU ; Jian ZHANG ; Nan GU ; Qijuan DONG ; Ruiyun LIU ; Hong ZHANG ; Haixia LIU ; Yongcai ZHAO ; Lin CHENG ; Lianshan PU ; Fang BIAN ; Gang HE ; Quanmin LI ; Wei DU ; Zhaoling WANG ; Wei XU ; Liyong ZHONG ; Xiaohui GUO
Chinese Journal of Diabetes 2025;33(3):210-214
Objective To evaluate the efficacy and safety of enteric-coated metformin hydrochloride capsules(Junlida?)in patients with T2DM and poor glycemic control under lifestyle interventions.Methods In this study,419 patients with T2DM were recruited from 15 research centers from July 2020 to March 2022,and randomly divided into observation(Obs)group(n=209)and control group(Con,n=210)using a multicenter,randomized,double-blind,non-inferiority trial design.Patients in the Obs group were treated with enteric-coated Metformin hydrochloride capsules(Junlida?),and patients in the Con group were treated with Metformin hydrochloride tablets(Glucophage?).The optimal effective dose of 2 g/d was achieved within 4 weeks,and the reasonable dose was maintained until the end of treatment.The treatment period was 24 weeks.HbA1c and its compliance rate,FPG,and body weight were compared between the two groups in full analysis set(FAS)and protocol set(PPS).Safety and adverse events(AE)were evaluated in safety set(SS).Results A total of 414 participants were randomized(207 cases in Obs group and 207 cases in Con group).414 cases in FAS population(207 cases in Obs group and 207 cases in Con group),and 328 cases in PPS population(164 cases in Obs group and 164 cases in Con group),and 414 cases in SS population(207 cases in Obs group and 207 cases in Con group).After treatment,HbA1c,FPG and body weight were lower in both groups(P<0.05)in FAS and PPS.HbA1c compliance rate was not significantly different between the two groups in FAS and PPS(P>0.05).The results of non-inferiority test showed that the lower limit was>-0.4%in both FAS(-0.154,95%CI-0.384~0.069)and PPS(-0.139,95%CI-0.390~0.112),and the Obs group reached non-inferiority end point.The achievement rate,compliance rate,safety index and incidence of AE were not significantly different between the two groups(P>0.05).Conclusions Junlida? demonstrated non-inferiority to Glucophage? in glycemic control and can be safely and effectively used in patients with diabetes.

Result Analysis
Print
Save
E-mail