1.CXCL17 methylation as a potential marker for papillary thyroid carcinoma
Chenxia JIANG ; Mengxia LI ; Haixia HUANG ; Junjie LI ; Yifei YIN ; Rongxi YANG
Chinese Journal of Clinical and Experimental Pathology 2025;41(5):627-633,638
Purpose To investigate the correlation between the methylation level at CpG sites of CXCL17 and the clinicopathological parameters of papillary thyroid carcinoma(PTC).Methods samples from 186 cases of PTC and 191 cases of benign thyroid nodule(BTN)were collected.Methylation levels of CXCL17 were semi-quantitatively as-sessed using mass spectrometry.Logistic regression analysis,which adjusted for age,gender and related hormones,was conducted to evaluate the correlation between CXCL17 methylation and PTC,and calculate the odds ratios(ORs)and 95%confidence intervals(CIs).Results Hypomethylation level of CXCL17_CpG_1.2 was significantly associat-ed with PTC(OR=1.36,95%CI:1.16-1.60,P<0.001)and early stage of PTC patients(Stage Ⅰ,OR=1.41,95%CI:1.19-1.67,P<0.001).Gender-based hierarchical management analysis showed that decreased methyla-tion level of CXCL17_CpG_1.2 was significantly associated with female PTC patients(OR=1.39,95%CI:1.15-1.67,P<0.001).In subgroups stratified by age(<50 and≥50 years old),hypomethylation at CXCL17_CpG_1.2 was significantly associated with PTC,with a stronger association in the younger subgroup(<50 years old:OR=1.42,95%CI:1.14-1.77,P<0.01;≥ 50 years old:OR=1.30,95%CI:1.03-1.64,P<0.05).Conclusion There was a significant difference in CXCL17 methylation levels between benign and malignant thyroid tumors.It was showed that hypomethylation of CXCL17 is closely associated with PTC,particularly in young women patient.Thus,CXCL17 methylation may serve as a biomarker for accurate differential diagnosis of thyroid nodule.
2.CXCL17 methylation as a potential marker for papillary thyroid carcinoma
Chenxia JIANG ; Mengxia LI ; Haixia HUANG ; Junjie LI ; Yifei YIN ; Rongxi YANG
Chinese Journal of Clinical and Experimental Pathology 2025;41(5):627-633,638
Purpose To investigate the correlation between the methylation level at CpG sites of CXCL17 and the clinicopathological parameters of papillary thyroid carcinoma(PTC).Methods samples from 186 cases of PTC and 191 cases of benign thyroid nodule(BTN)were collected.Methylation levels of CXCL17 were semi-quantitatively as-sessed using mass spectrometry.Logistic regression analysis,which adjusted for age,gender and related hormones,was conducted to evaluate the correlation between CXCL17 methylation and PTC,and calculate the odds ratios(ORs)and 95%confidence intervals(CIs).Results Hypomethylation level of CXCL17_CpG_1.2 was significantly associat-ed with PTC(OR=1.36,95%CI:1.16-1.60,P<0.001)and early stage of PTC patients(Stage Ⅰ,OR=1.41,95%CI:1.19-1.67,P<0.001).Gender-based hierarchical management analysis showed that decreased methyla-tion level of CXCL17_CpG_1.2 was significantly associated with female PTC patients(OR=1.39,95%CI:1.15-1.67,P<0.001).In subgroups stratified by age(<50 and≥50 years old),hypomethylation at CXCL17_CpG_1.2 was significantly associated with PTC,with a stronger association in the younger subgroup(<50 years old:OR=1.42,95%CI:1.14-1.77,P<0.01;≥ 50 years old:OR=1.30,95%CI:1.03-1.64,P<0.05).Conclusion There was a significant difference in CXCL17 methylation levels between benign and malignant thyroid tumors.It was showed that hypomethylation of CXCL17 is closely associated with PTC,particularly in young women patient.Thus,CXCL17 methylation may serve as a biomarker for accurate differential diagnosis of thyroid nodule.
3.Study on different test methods to evaluate the drying effect of flexible endoscope
Xianhuang LI ; Ziyi HUANG ; Liuji CHEN ; Jing ZHEN ; Haixia LIU ; Yanxia ZHANG ; Xun ZHANG ; Xi HUANG ; Jiuhong MA
China Journal of Endoscopy 2025;31(11):34-39
Objective To compare the effectiveness of cobalt chloride test papers and borescope in evaluating the drying of endoscopes,providing a reference for clinical selection of appropriate assessment tools.Methods 10 gastroscopes and 10 colonoscopes procedures were selected from November 2023 to March 2024 for circulation experiments.After endoscope reprocessing,they were randomly divided into five groups with different drying times(30 s,3 min,6 min,9 min,and 12 min)with 200 samples.Cobalt chloride test paper and borescope were used to evaluate the drying effectiveness.Results The qualified rate of gastrointestinal endoscope by borescope was significantly higher than that by cobalt chloride test paper,but cobalt chloride test paper was obviously better than that by borescope in convenience and cost-effectiveness.The borescope had the function of visualization,and the quantitative positioning observation of residual droplets showed that there were a large number of droplets left after gastrointestinal endoscope drying for 30 s,and the number of droplets was obviously reduced after drying for 3 min.Among them,the gastroscope was mainly light(1~5 drops/strip)and none(0 drops/strip),and the colonoscope was mainly moderate(6~10 drops/strip)and light droplets.Compared with different drying times,there was a significant statistical difference in the number of residual droplets in the endoscope(P<0.01),and the localized droplets mainly remained in the distal bending part and the proximal bifurcation part of the lumen.Conclusion Both cobalt chloride test papers and borescope are important methods for assessing endoscope drying efficacy,each with its own advantages and limitations.Clinicians can use both methods in combination to comprehensively evaluate the overall dryness of endoscopes,thereby ensuring the safety and effectiveness of the endoscope reprocessing process.
4.Monitoring of bacterial contamination of water specimens at different pre-discharge time of flexible endoscopic final rinse water before daily use:a multicenter study
Jing ZHEN ; Liuji CHEN ; Yangyang ZHANG ; Ziyi HUANG ; Haixia LIU ; Xianhuang LI ; Xi HUANG ; Jiuhong MA
Chinese Journal of Infection Control 2025;24(2):236-241
Objective To investigate the bacterial contamination of water specimens at different pre-discharge time of flexible endoscopic final rinse water before daily use,and provide reference basis for choosing the optimal pre-dis-charge time in clinical work.Methods From August to December 2023,the water produced by the purified water equipment of the digestive endoscopy centers of 4 tertiary first-class medical institutions in Jiangxi Province,as well as the final rinsing water at the terminal-point at different pre-discharge times(before pre-discharge,discharge of 1,3,5,and 10 minutes)were subjected to on-site sampling,the collected water specimens were performed microbio-logical cultures by pouring and filter membrane methods,unqualified water specimens were performed bacterial i-dentification.Results 48 specimens of water produced by purified water equipment were collected,with qualified rate of 100%.480 final water specimens were collected,with a qualified rate of 0 before pre-discharge.The quali-fied rates of pre-discharge at 1,3,5,and 10 minutes were 0,21.88%,55.21%,and 73.96%,respectively.Bac-terial colony counts in the final rinse water with different pre-discharge times in 4 medical institutions showed statis-tically significant differences(all P<0.001).As the pre-discharge time increased,bacterial colony counts in the fi-nal rinse water of all four medical institutions showed a decreasing trend.The pairwise comparison of the overall bacterial colony count of the final rinse water at different pre-discharge time showed that there was no statistically significant difference in the bacterial colony count of the final rinse water at 5 and 10 minutes of pre-discharge(P>0.05),while the pairwise comparison between other time points showed statistically significant differences(all P<0.001).Environmental contaminated bacteria such as Micrococcus luteus,Cupriavidus paucula,and Sphin-gononas paucimobilis were detected from the unqualified water specimens.Conclusion With the extension of pre-discharge time,the degree of bacterial contamination in the final rinse water significantly decreases.All levels of medical institutions need to pre-discharge the final rinse water daily,and the pre-discharge time should last for at least 5 minutes.
5.Application and management status of automated endoscope reprocessors in 292 medical institutions
Jin ZHEN ; Liuji CHEN ; Haixia LIU ; Jiuhong MA ; Xianhuang LI ; Xi HUANG
Chinese Journal of Infection Control 2025;24(9):1278-1285
Objective To understand the current status of application,management,and maintenance of automa-ted endoscope reprocessors(AERs)in China.Methods A questionnaire survey was conducted using convenience sampling method on the application,management,maintenance,and monitoring of AERs,as well as personnel training in digestive endoscopy centers of 292 medical institutions(MIs).Results A total of 316 questionnaires were distributed,and 292 were available,with an effective response rate of 92.41%.Among the 292 MIs,198(67.81%)were equipped with AERs,with equipment rates of 75.11%in tertiary MIs and 41.27%in secondary MIs.88.38%of MIs performed manual cleaning before placing endoscopes into AERs,while 2.02%of MIs still didn't perform this step,mainly in tertiary MIs.The most common problems in the application of AERs were the detachment or damage of connecting pipes(83.33%),followed by disinfectant leakage of AERs(43.94%),mal-function of control panel(43.94%),and failure or poor water flow of AER pipeline(42.93%).92.42%of MIs regularly disinfected AERs,72.73%of MIs regularly replaced AER air filters,and 80.30%of MIs regularly re-placed AER water filters.96.46%of MIs monitored the concentration of disinfectants before daily application of AERs,87.88%of MIs regularly monitored the final rinse water of AERs,and 96.97%of MIs provided professio-nal training for new employees to use AERs for the first time.Conclusion The equipping rate of AERs at all levels of MIs in China still needs to be improved.Most MIs are able to monitor and maintain AERs well,but there are still many problems in the application process.Due to the large volume of endoscopic diagnosis and treatment as well as insufficient execution rate of manual cleaning in tertiary MIs,it is necessary to optimize workflow and strengthen training.Secondary MIs face challenges such as equipment shortages and low monitoring execution rates,requiring increased funding and regulatory efforts.It is recommended that manufacturers continuously optimize AER design,MIs establish standardized AER application protocol,and relevant departments improve AER application and ma-nagement standards,in order to improve the quality of endoscopic cleaning and disinfection and ensure patient safety during diagnosis and treatment.
6.Application and management status of automated endoscope reprocessors in 292 medical institutions
Jin ZHEN ; Liuji CHEN ; Haixia LIU ; Jiuhong MA ; Xianhuang LI ; Xi HUANG
Chinese Journal of Infection Control 2025;24(9):1278-1285
Objective To understand the current status of application,management,and maintenance of automa-ted endoscope reprocessors(AERs)in China.Methods A questionnaire survey was conducted using convenience sampling method on the application,management,maintenance,and monitoring of AERs,as well as personnel training in digestive endoscopy centers of 292 medical institutions(MIs).Results A total of 316 questionnaires were distributed,and 292 were available,with an effective response rate of 92.41%.Among the 292 MIs,198(67.81%)were equipped with AERs,with equipment rates of 75.11%in tertiary MIs and 41.27%in secondary MIs.88.38%of MIs performed manual cleaning before placing endoscopes into AERs,while 2.02%of MIs still didn't perform this step,mainly in tertiary MIs.The most common problems in the application of AERs were the detachment or damage of connecting pipes(83.33%),followed by disinfectant leakage of AERs(43.94%),mal-function of control panel(43.94%),and failure or poor water flow of AER pipeline(42.93%).92.42%of MIs regularly disinfected AERs,72.73%of MIs regularly replaced AER air filters,and 80.30%of MIs regularly re-placed AER water filters.96.46%of MIs monitored the concentration of disinfectants before daily application of AERs,87.88%of MIs regularly monitored the final rinse water of AERs,and 96.97%of MIs provided professio-nal training for new employees to use AERs for the first time.Conclusion The equipping rate of AERs at all levels of MIs in China still needs to be improved.Most MIs are able to monitor and maintain AERs well,but there are still many problems in the application process.Due to the large volume of endoscopic diagnosis and treatment as well as insufficient execution rate of manual cleaning in tertiary MIs,it is necessary to optimize workflow and strengthen training.Secondary MIs face challenges such as equipment shortages and low monitoring execution rates,requiring increased funding and regulatory efforts.It is recommended that manufacturers continuously optimize AER design,MIs establish standardized AER application protocol,and relevant departments improve AER application and ma-nagement standards,in order to improve the quality of endoscopic cleaning and disinfection and ensure patient safety during diagnosis and treatment.
7.Study on different test methods to evaluate the drying effect of flexible endoscope
Xianhuang LI ; Ziyi HUANG ; Liuji CHEN ; Jing ZHEN ; Haixia LIU ; Yanxia ZHANG ; Xun ZHANG ; Xi HUANG ; Jiuhong MA
China Journal of Endoscopy 2025;31(11):34-39
Objective To compare the effectiveness of cobalt chloride test papers and borescope in evaluating the drying of endoscopes,providing a reference for clinical selection of appropriate assessment tools.Methods 10 gastroscopes and 10 colonoscopes procedures were selected from November 2023 to March 2024 for circulation experiments.After endoscope reprocessing,they were randomly divided into five groups with different drying times(30 s,3 min,6 min,9 min,and 12 min)with 200 samples.Cobalt chloride test paper and borescope were used to evaluate the drying effectiveness.Results The qualified rate of gastrointestinal endoscope by borescope was significantly higher than that by cobalt chloride test paper,but cobalt chloride test paper was obviously better than that by borescope in convenience and cost-effectiveness.The borescope had the function of visualization,and the quantitative positioning observation of residual droplets showed that there were a large number of droplets left after gastrointestinal endoscope drying for 30 s,and the number of droplets was obviously reduced after drying for 3 min.Among them,the gastroscope was mainly light(1~5 drops/strip)and none(0 drops/strip),and the colonoscope was mainly moderate(6~10 drops/strip)and light droplets.Compared with different drying times,there was a significant statistical difference in the number of residual droplets in the endoscope(P<0.01),and the localized droplets mainly remained in the distal bending part and the proximal bifurcation part of the lumen.Conclusion Both cobalt chloride test papers and borescope are important methods for assessing endoscope drying efficacy,each with its own advantages and limitations.Clinicians can use both methods in combination to comprehensively evaluate the overall dryness of endoscopes,thereby ensuring the safety and effectiveness of the endoscope reprocessing process.
8.Pharmacognostic Investigation of Pulsatillae Radix along with Advances in Research on Its Chemical Constituents and Pharmacological Effects
Shuhui HUANG ; Haixia ZENG ; Liping CHENG ; Xiang ZHANG ; Xongning LIU ; Linping HUANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(6):1592-1606
This paper presents a comprehensive study of Pulsatillae Radix,encompassing its pharmacognostic investigation,chemical constituents,and pharmacological effects.Pulsatillae Radix,first recorded in the Shen Nong's Herbal Classic,is known for its efficacy in cooling blood to stop dysentery,clearing heat,and detoxifying,and has been used to treat diseases such as enteritis caused by parasites,demonstrating potential as an antiviral candidate.Research has revealed that its major chemical constituents include triterpenoid saponins,triterpenic acids,and various other components,which collectively constitute the pharmacological foundation of Pulsatillae Radix.Significant pharmacological activities have been observed in antitumor,anti-inflammatory,antimicrobial,and antiviral aspects,providing a scientific basis for its broad application in the pharmaceutical field.
9.Building of an intelligent DRG grouping audit system in a hospital
Juan ZHANG ; Yang PU ; Wen LIU ; Yingpeng WANG ; Lianhua KONG ; Yaxin HUANG ; Bin WAN ; Haixia DING
Chinese Journal of Hospital Administration 2025;41(8):614-618
Diagnosis-related groups (DRG) payment is an important component of deepening the reform of medical insurance payment methods. In June 2023, a tertiary hospital launched an intelligent DRG grouping audit system to enhance grouping accuracy. By establishing a multi departmental collaborative organizational structure, building a standardized knowledge base and a rule base covering five categories (diagnosis, fees, testing, nursing, and pathology), and integrating electronic medical records, medical orders, testing, and imaging data throughout the entire diagnosis and treatment process, the intelligent DRG grouping audit system with data collection, identification, extraction, comparison, and output modules was constructed to achieve intelligent audit. At the same time, it was formed a closed-loop management system for pre reporting quality control, in-process group entry control, and post data analysis and assessment, which would prevent the risk of differentiated behaviors such as high coding and high sets, and ensure the reasonable use of medical insurance funds. By January 2024, the system had covered 89 ADRG groups, and improved the efficiency and quality of DRG grouping audit. Compared with February to May 2023, the monthly average rejection rate of medical records on the first page decreased by 9.4% after the system was put into operation (June to December 2023), and core medical indicators such as the number of DRG groups, medical insurance settlement cases, and time consumption index continued to improve. The practical experience could provide reference and inspiration for other hospitals in China.
10.Research and application of a new deep learning based strategy for platelet histogram review
Enming ZHANG ; Chao YANG ; Xianchun CHEN ; Yan LIN ; Taixue AN ; Haixia LI ; Yongjian HE ; Zhiwei LIU ; Limei FENG ; Wanying LIN ; Tie XIONG ; Kai QIU ; Ya GAO ; Lizhu HUANG ; Jing HE ; Chunyan WANG ; Dehua SUN ; Bo SITU ; Lei ZHENG
Chinese Journal of Laboratory Medicine 2025;48(9):1201-1206
Objective:To develop an artificial intelligence (AI)-based platelet review strategy to identify abnormal platelet histograms with no significant difference between initial impedance platelet count (PLT-I) and PLT-F results.Methods:This study included 5 119 routine blood analysis in Nanfang Hospital of Southern Medical University and its Ganzhou branch from July 2023 and March 2024. Specimens exhibiting abnormal platelet histograms and an initial platelet count >40×10?/L underwent review using the fluorescent platelet count (PLT-F) channel. Consistency of the results was defined as a difference between impedance platelet count (PLT-I) and PLT-F less than ±20% of the PLT-F results. A deep learning model was developed using platelet and red blood cell histogram data from a training set of 3 807 specimens. The model′s diagnostic performance was evaluated on an independent external validation set ( n=805) using receiver operating characteristic (ROC) curve analysis. Changes in the number of reviewed samples and sample turnaround time were analyzed to assess its clinical utility. Results:The deep learning model based on platelet and red blood cell histograms achieved an area under the ROC curve (AUC) of 0.854 in the training set. At a cutoff value of 0.1, the sensitivity was 0.954 and specificity was 0.358. The model could reduce review by 16.80% (190/1 131). In the validation set, the AUC was 0.805, with a sensitivity of 0.955 and specificity of 0.307, corresponding to a reduction of 17.41% (47/270) in reviewed specimens.Conclusion:The platelet review prediction model developed based on deep learning technology can efficiently identify samples with consistent results before and after review, reducing unnecessary reviews and shortening specimen testing time, thereby improving the efficiency of platelet test.