1.Regulation of histidine metabolism by Lactobacillus Reuteri mediates the pathogenesis and treatment of ischemic stroke.
Kangrui HU ; Zhihao ZHOU ; Haofeng LI ; Jijun XIAO ; Yun SHEN ; Ke DING ; Tingting ZHANG ; Guangji WANG ; Haiping HAO ; Yan LIANG
Acta Pharmaceutica Sinica B 2025;15(1):239-255
Increasing evidence has underscored the significance of post-stroke alterations along gut-brain axis, while its role in pathogenesis and treatment of ischemic stroke (IS) remains largely unexplored. This study aimed to elucidate the therapeutic effects and action targets of Panax notoginseng saponins (PNS) on IS and explore a novel pathogenesis and treatment strategy of IS via profiling the microbial community and metabolic characteristics along gut-brain axis. Our findings revealed for the first time that the therapeutic effect of PNS on IS was microbiota-dependent. Ischemia/reperfusion (I/R) modeling significantly down-regulated Lactobacilli in rats, and PNS markedly recovered Lactobacilli, particularly Lactobacillus reuteri (L.Reu). Metabolomics showed a significant reduction in serum histidine (HIS) in clinical obsolete IS patients and rehabilitation period I/R rats. Meanwhile, the L.Reu colonization in I/R rats exhibited significant neuroprotective activity and greatly increased HIS in serum, gut microbiota, and brain. Moreover, exogenous HIS demonstrated indirect neuroprotective effects through metabolizing to histamine. Notably, vagus nerve severance in I/R rats was performed to investigate HIS's neuroprotective mechanism. The results innovatively revealed that PNS could promote HIS synthesis in gut by enhancing L.Reu proportion, thereby increasing intracerebral HIS through peripheral pathway. Consequently, our data provided novel insights into HIS metabolism mediated by L.Reu in the pathogenesis and treatment of IS.
2.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
3.Construction and preliminary verification of a nomogram for survival of TKI-treated adult patients with newly diagnosed chronic myelogenous leukemia in the chronic phase
Guangling HU ; Haiping LIANG ; Xuehan MA ; Bei LIU
Journal of Leukemia & Lymphoma 2025;34(1):16-23
Objective:To investigate the related factors affecting the survival of adult patients with newly diagnosed chronic myeloid leukemia in the chronic phase (CML-CP) treated with tyrosine kinase inhibitor (TKI) and the prognostic predictive effect of the nomogram constructed according to them.Methods:A retrospective cohort study was conducted. Clinical general information and laboratory index data of 243 newly diagnosed adult CML-CP patients treated with TKI in the First Hospital of Lanzhou University from December 2008 to June 2023 were collected, and they were divided into a training set (194 patients) and a validation set (49 patients) by complete randomization in the ratio of 8∶2. In the training set, variables affecting poor overall survival (OS) of patients were analyzed using univariate and multivariate Cox proportional hazards models by R4.3.2 software to obtain the independent influences of poor OS, on the basis of which the Cox regression model was constructed and the nomogram predicting the OS rate at 8 and 10 years was plotted. Kaplan-Meier method was applied to analyze the OS in all 243 patients and patients stratified by the screened independent influencing factors for poor OS, and log-rank test was used for comparison between the groups. In the training and validation sets, receiver operating characteristic (ROC) curve was used to analyze the effect of the nomogram on predicting 8- and 10-year OS rates of patients with actual survival as the gold standard; calibration curve was used to assess the accuracy of predictions of the nomogram; decision curve analysis (DCA) was used to assess the clinical utility of the nomogram.Results:The median age of 243 CML-CP patients [ M ( Q1, Q3)] was 46 (35, 58) years old, 150 cases (61.7%) were male and 9 cases (38.3%) were female, 119 cases (49.0%) had comorbidities, and the efficacy of 82 cases (33.7%) reached molecular response (MR) 5.0. Differences in patient compositions for age and gender, levels of major indicators for peripheral blood and bone marrow, spleen size, comorbidities, short-term efficacy, Sokal score, and long-term survival score of European Treatment and Outcomes Study between the training and validation sets were not statistically significant (all P > 0.05). Multivariate Cox regression analysis showed that patients with elevated age ( HR = 1.04, 95% CI: 1.01-1.08, P = 0.041), comorbidities (with vs. without, HR = 3.48, 95% CI: 1.23-9.86, P = 0.019), and those who did not achieve MR5.0 (achieved vs. unachieved, HR = 0.13, 95% CI: 0.02-0.97, P = 0.046) were independent risk factors for poor OS in TKI-treated newly diagnosed adult CML-CP patients. By the last follow-up (December 2023), the median follow-up was 72 months, with the range of 6-180 months. Kaplan-Meier method analysis showed that the 8- and 10-year OS rates of 243 patients were 83.7% and 81.6%, respectively; patients with age ≥46 years compared to <46 years, with comorbidities compared to without comorbidities, and who did not achieve MR5.0 in terms of efficacy compared to who achieved MR5.0, the OS was poorer, and the differences were statistically significant (all P < 0.01). The nomogram of 8- and 10-year OS rates in TKI-treated newly diagnosed adult CML-CP patients was constructed based on the screened independent influencing factors of poor OS. The area under the ROC curve was 0.910 and 0.851 in the training set and 0.778 and 0.764 in the validation set for the predicted 8- and 10-year OS rates based on the nomogram, respectively, and the calibration curve showed that the predicted 8- and 10-year OS rates based on the nomogram were in high agreement with the actual ones in the training and validation sets; the DCA showed that the nomogram within a certain prediction threshold could benefit the clinical decision-making in both the training and validation sets. Conclusions:Having comorbidities, not reaching MR5.0 in efficacy and old age are independent risk factors for poor survival of TKI-treated adult patients with newly diagnosed CML-CP, and the nomogram constructed based on these 3 factors has a good predictive ability for the survival of such patients.
4.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
8.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
9.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
10.Water quality of self-provided wells water in Haidian District in Beijing in 2018 - 2022
Yongmei HU ; Xueying LIU ; Shuping ZHU ; Haiping CHEN
Journal of Public Health and Preventive Medicine 2024;35(3):86-89
Objective To investigate the water quality and sanitary conditions of rural self-provided wells water in Haidian District, Beijing, and to provide reference for strengthening water supply management of self-provided wells. Methods The water quality monitoring data of rural self-provided wells in Haidian District from 2018 to 2022 were analyzed. Results A total of 1 568 water samples were tested in 2018-2022 , of which 1 486 were qualified, with a qualified rate of 94.77%. The qualified rate in each year was 86.75% , 92.86% , 97.48% , 98.06% , and 99.34% , respectively , and the difference was statistically significant ( χ2= 75.296 , P<0.05). The qualified rates of sensory traits and general chemical indexes, toxicological indexes and microbial indexes were 97.70%, 97.58% and 98.28%, respectively. There were statistically significant differences in the qualified rates among the three indexes in 2018, 2019 and 2021 (P < 0.05). The unqualified indicators included total hardness, total number of colonies, total coliform, fluoride, nitrate and turbidity, with a qualified rate of 97.96%, 98.41%, 99.17%, 99.11%, 98.47% and 99.94%, respectively. Conclusion The water quality of self-provided wells in rural Haidian District is good. Relevant departments should continue to strengthen the supervision of self-provided wells, such as the supervision of self-provided wells disinfection devices and water treatment equipment, to ensure the safety of drinking water for residents.


Result Analysis
Print
Save
E-mail