1.Characteristics of HIV primary drug resistance and molecular transmission clusters in newly reported men who had sex with men in Taizhou City, Zhejiang Province
Shanling WANG ; Xuanhe WU ; Guixia LI ; Tingting WANG ; Yating WANG ; Tailin CHEN ; Weiwei SHEN ; Yali XIE ; Haijiang LIN ; Na HE ; Xiaoxiao CHEN
Shanghai Journal of Preventive Medicine 2025;37(6):496-502
ObjectivesTo investigate the molecular epidemiological characteristics of HIV-1 infection among men who had sex with men (MSM) in Taizhou City, Zhejiang Province, and to provide a scientific reference for acquired immune deficiency syndrome prevention and control efforts. MethodsThe research subjects were all newly reported MSM population in Taizhou City from 2020 to 2023. Blood samples without antiviral therapy were collected. The HIV-1 pol gene was amplified and sequenced, and the sequences were submitted to the Stanford University drug resistance database to identify the mutation sites and drug resistance. MEGA 11.0 software was used to analyze the nucleic acid sequences, construct phylogenetic tree, and calculate genetic distance of gene sequences. The molecular transmission network diagram of HIV-1 was constructed using Cytoscape_v3.10.1, and the influencing factors of network entry were analyzed by logistic regression. ResultsA total of 363 newly reported HIV-infected MSM patients were included, with a median age [M (P25, P75)] of 34 (26,47) years old. The majority had an educational level of junior high school or below (55.65%). A total of eight subtypes were found, mainly CRF07_BC and CRF01_AE. The primary drug resistance rate was 10.47% (38/363). The optimal molecular network gene distance was 0.019, with a network access rate of 42.70% (155/363), and a total of 47 molecular clusters were formed. Multivariate logistic analyses showed that compared with the CRF01_AE subtype, the clustering risk of CRF07_BC subtype was higher (OR=1.916, 95%CI: 1.191‒3.109), cases with drug resistance had a higher risk of cluster formation than those without drug resistance (OR=2.011, 95%CI: 1.006‒4.080), and recent infected patients had a lower risk of entering the largest molecular cluster than long-term infected patients (OR=0.376, 95%CI: 0.137‒0.928). ConclusionThe newly diagnosed infections among the MSM population are active in Taizhou City, Zhejiang Province, with a high level of primary drug resistance. Individuals carrying drug-resistant strains are more likely to cluster. Drug resistance monitoring should be strengthened to prevent further spread of drug-resistant strains in the network.
2.Research progress on early screening methods for occupational noise-induced hearing loss
Aihua LI ; Wenyan YU ; Hongyan YANG ; Weihong CAI ; Rui ZHANG ; Haijiang FENG ; Huaiying TAO ; Yixian MA ; Yan YE
Journal of Environmental and Occupational Medicine 2025;42(11):1400-1404
Occupational noise-induced hearing loss (NIHL) is an irreversible sensorineural hearing loss that severely endangers workers’ health, making early screening crucial. This article reviewed the research progress on early screening methods for occupational NIHL, introduced the testing mechanisms of three core screening methods—tympanometry, otoacoustic emissions, and extended high-frequency audiometry —and summarized their clinical application advantages and limitations. It is proposed that multimodal combined detection (e.g., the combination of tympanometry, otoacoustic emissions, and extended high-frequency audiometry) can significantly improve the accuracy and comprehensiveness of early screening. Meanwhile, future studies with prospective cohort design are encouraged to verify the long-term monitoring value of each method and to strengthen the joint development of screening technologies with cutting-edge approaches such as machine learning, in order to further improve screening efficiency and provide stronger protection for workers’ hearing health.
3.Application of"rotation-correction loop technique"in the retrieval of complex inferior vena cava filters
Jie HU ; Maolin QIAO ; Qinqin TIAN ; Heng WANG ; Sheng YAN ; Wenbo ZHAO ; Yongbin SHI ; Peilu SHI ; Miao XING ; Haifeng LI ; Haijiang JIN ; Ping WANG ; Wenkai CHANG ; Yuwen WANG ; Honglin DONG
Journal of Interventional Radiology 2024;33(3):289-294
Objective To discuss the application of the"rotating guidewire and correcting the filter recovery hook direction technique"("rotation-correction loop technique"for short),a technique invented by the authors in clinical practice,in the retrieval of complex inferior vena cava filter(IVCF),and to discuss its technical skills and advantages.Methods The clinical data of 417 patients carrying an IVCF,who were admitted to the Department of Vascular Surgery of Second Hospital of Shanxi Medical University of China to retrieve IVCF between January 2022 and December 2022,were retrospectively analyzed.Taking the time spent on the retrieval of IVCF and the intraoperative radiation dose as the evaluation indicators,the advantages and disadvantages of the standard filter retrieval technique,the"rotation-correction loop technique"and the other loop-assisted techniques were compared.Results Both the intraoperative radiation dose and the time spent on the retrieval of IVCF using"rotation-correction loop technique"were remarkably lower than those of other loop-assisted techniques(P<0.000 1).Conclusion For the retrieval of complex IVCF,especially for the IVCF which is heavily tilted and/or its recovered hook is attached to the vascular wall,the use of"rotation-correction loop technique"can shorten the time spent on the the retrieval of IVCF and reduce the intraoperative radiation dose.This technique carries high safety and practicability,the device is simple and it can be manipulated by single physician,which is conducive to clinical application and promotion.(J Intervent Radiol,2024,33:289-294)
4.Early clinical outcomes of the domestic KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation: A single-arm, prospective, single-group target value clinical trial
Tong TAN ; Bingqi FU ; Peijian WEI ; Nianjin XIE ; Haozhong LIU ; Xiaoyi LI ; Shengwen WANG ; Haijiang GUO ; Jian LIU ; Jimei CHEN ; Jian ZHUANG ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):269-275
Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.
5.Syphilis infection among male sexually transmitted disease outpatients in Taizhou from 2009 to 2021
Shanling WANG ; Chang LI ; Tingting WANG ; Yating WANG ; Weiwei SHEN ; Haijiang LIN ; Xiaoxiao CHEN
Shanghai Journal of Preventive Medicine 2024;36(8):726-729
ObjectivesTo determine the syphilis infection and risk factors among the male outpatients in sexually transmitted disease (STD) clinics in Taizhou, and to provide a scientific evidence for the development of comprehensive prevention and intervention strategies for syphilis. MethodsA questionnaire survey and serological testing were conducted among the male STD outpatients in the hospitals designated for STD treatment in Jiaojiang, Linhai, Luqiao and Sanmen in Taizhou. Logistic regression analysis was used to determine the risk factors associated with syphilis infection. ResultsA total of 16 400 male STD outpatients were investigated, with a syphilis infection rate of 2.10%. Multivariate analysis showed that aged over 60, non-local household registration, engaging in sexual activity with commercial sex workers in the past three months, having two or more sexual partners in the past three months, engaging in anal sex with heterosexual partners, co-infection with human immunodeficiency virus (HIV), and co-infection with hepatitis C virus (HCV) were significantly associated with a higher syphilis infection rate (all P<0.05). Knowledge of HIV/AIDS, a history of chlamydia infection in the past year, and a history of genital wart infection were significantly associated with a lower syphilis infection rate (all P<0.05). ConclusionSyphilis infection among the male STD outpatients in Taizhou remained lower, compared with the national average level. Targeted comprehensive prevention and control strategies should be implemented based on relevant risk factors. Screening and prevention interventions should be prioritized for the individuals with non-local household registration, at-risk sexual behavior, and co-infection with HCV and HIV. Strengthening the collaborative efforts is also recommended for joint prevention and control of HIV/AIDS and syphilis.
6.Treatment failure and drug resistance among the newly reported HIV-infected patients in Taizhou City from 2020 to 2022
Yan LI ; Xuanhe WU ; Lu SHI ; Guixia LI ; Shanling WANG ; Yating WANG ; Tailin CHEN ; Tingting WANG ; Yali XIE ; Weiwei SHEN ; Haijiang LIN ; Xiaoxiao CHEN ; Na HE
Shanghai Journal of Preventive Medicine 2024;36(11):1031-1038
ObjectiveTo analyze the failure of antiretroviral therapy (ART) and drug resistance characteristics among the newly reported HIV-infected patients in Taizhou City from 2020 to 2022. MethodsBlood samples, sociodemographic characteristics and ART information of the newly reported HIV-infected patients who received ART for ≥6 months in Taizhou City from 2020 to 2022 were collected for the detection of recent infections and HIV-1 genotypic drug resistance. Multivariate logistic regression analysis was used to analyze the influencing factors of treatment failure. The gene sequences of cases with failed ART were submitted to the HIV drug resistance database of Stanford University to determine the drug resistance mutation sites and drug resistance characteristics. ResultsAmong the 1 023 newly reported HIV-infected patients receiving ART, the median age (P25,P75) was 47 (33, 58) years, 81.4% were male, 66.4% (679/1 023) were infected through heterosexual transmission, 74.7% had a WHO clinical stage Ⅰ/Ⅱ, 62.2% had a baseline CD4 count of >200 cell·μL-1, 94.4% (966/1 023) received an immediate ART, and 78.7% were long-term infected. Among the 66 patients with treatment failure (6.5%), the likelihood of treatment failure was lower in those with homosexual transmission (OR=0.39, 95%CI: 0.17‒0.84) and without history of sexually transmitted disease (STD) (OR=0.45, 95%CI: 0.24‒0.92), but higher in those with a baseline CD4 count of ≤200 cell·μL-1, delayed ART (OR=3.19, 95%CI: 1.24‒7.52), and primary drug resistance (OR=4.69, 95%CI: 1.68‒11.89). Among the 36 HIV-infected patients with virological failure, 27 sequences were successfully amplified, with a successful amplification rate of 75.0% (27/36). The total drug resistance rate was 55.6% (15/27), of which the drug resistance rates of nucleoside reverse transcriptase inhibitors (NRTIs), non-nucleoside reverse transcriptase inhibitors (NNRTIs) and protease inhibitors (PIs) were 37.0% (10/27), 51.9% (14/27) and 3.7% (1/27), respectively. Among the NNRTIs, the degree of resistance to efavirenz and nevirapine was consistent, with a majority (51.9%) of highly drug-resistant. K103N and M184V were the most common mutation sites, but PIs mutations occured less frequently. A total of 8 genotypes of HIV-1 were detected, in which subtype CRF01_AE accounted for 37.0% (10/27), followed by CRF07_BC [14.8% (4/27)], CRF08_BC [14.8% (4/27)] and subtype C [14.8% (4/27)]. ConclusionDuring the period from 2020 to 2022, the newly reported HIV-infected individuals in Taizhou City were predominated by long-term infections. Immediate initiation of ART can reduce the risk of treatment failure in HIV-infected individuals. Virological treatment failures are primarily associated with resistance to NRTIs and NNRTIs. It is recommended to strengthen active detection and promptly initiate ART to minimize the occurrence of ART failure. Simultaneously, there is a need to intensify drug resistance detection targeted for those with treatment failure, so as to provide a scientific guidance for drug replacement.
7.A novel homozygous mutation in the SACS gene causing autosomal recessive spastic ataxia of Charlevoix-Saguenay: study of a family
Haijiang LI ; Ailan PANG ; Yanlan ZHANG ; Yanbing HAN
Chinese Journal of Neurology 2024;57(6):593-599
Objective:To report the clinical and genetic characteristics of autosomal recessive spastic ataxia of Charlevoix-Saguenay (ARSACS) induced by a new homozygous mutation in the SACS gene, and to improve the clinicians′ recognition of the disease. Methods:Detailed nervous system physical examination was performed on the patient and his parents from a consanguineous family admitted to the Genetics and Metabolism Clinic of the Department of Neurology, the First Affiliated Hospital of Kunming Medical University in March 2022. The peripheral blood DNA of the patient and his parents was extracted, and whole exon sequencing (WES) was performed on the patient and his parents using second-generation sequencing technology. The mutation sites were verified by Sanger sequencing, and the mutation sites were analyzed by software.Results:The 18-year-old Han ethnic male patient developed a progressive stiffness of his bilateral lower limbs and gait unsteadiness since the age of 3. He had pyramidal tract sign in his bilateral lower limbs, cerebellar ataxia, pes cavus and hammer toes. Brain magnetic resonance imaging (MRI) showed symmetrical low signal of bilateral pons, cerebellar atrophy and thinning of corpus callosum in T 2WI and T 2 fluid attenuated inversion recovery (FLAIR) sequences. Neuroelectrophysiological examination showed sensory motor peripheral neuropathy. Ophthalmic examination revealed concomitant exotropia and ametropia in both eyes. WES revealed a homozygous variant of c.6958T>C (p.Tyr2320His) in exon 10 of the SACS gene of the patient, and his parents were heterozygous variant carriers confirmed by Sanger sequencing. The variant was classified as possibly pathogenic (PM1+PM2+PP3+PP4) according to the American Society for Medical Genetics and Genomics. The patient was clearly diagnosed as ARSACS caused by homozygous mutation of c.6958T>C in the SACS gene. Conclusions:A novel pathogenic variant (c.6958T>C) in the SACS gene identified in this study leads to the manifestation of ARSACS. The primary clinical manifestations include cerebellar ataxia, pyramidal tract signs, and sensorimotor peripheral neuropathy. Head MRI examination of T 2WI and T 2FLAIR sequences with symmetrical low signal on both sides of the pons helps to narrow down the scope of differential diagnosis.
8.Research on calibration method of endoscopic liquid expansion pump
Jing HUANG ; Aowen DUAN ; Li YANG ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Hehua ZHANG
China Medical Equipment 2024;21(10):194-197
A corresponding calibration method was proposed for the key performance parameters of the endoscopic liquid expansion pump,such as the pressure indication error,the flow rate indication error and the flow rate repeatability.4 different brands of endoscopic liquid expansion pumps in clinical use in the hospital were selected for calibration,and the feasibility of the calibration method was evaluated.In the pressure and flow range of the endoscope liquid expansion pump,3 calibration points of high,medium and low were selected,and each flow point was calibrated 3 times.The calibration results showed that the maximum error of pressure indication was 4.3%,the maximum error of flow indication was 9.3%,and the maximum repeatability of flow indication value was 0.8%,all of which met the technical requirements for the maximum allowable error of"Medical Endoscopes.Endoscope Functional Supply Units.Irrigation Pump"(YY/T 0864-2011)and"Calibration Specification for Syringe Pumps and Infusion Pumps"(JJF 1259-2018).The calibration method for endoscopic liquid expansion pump can improve the metrological traceability system of this type of equipment,ensure the accuracy and reliability of equipment values,improve product quality,and ensure medical safety.
9.Effect of negative pressure level on drain volume and prognosis of patients after prosthetic augmentation mammoplasty through inframammary fold incision
Haiyang ZHAO ; Ximei WANG ; Haijiang DONG ; Zhibin LI ; Baihui XIE ; Chengxiang YAN
Chinese Journal of Plastic Surgery 2023;39(4):375-383
Objective:To investigate the effect of different negative pressure level on drain volume after augmentation mammoplasty through inframammary fold incision, and try to put forward the appropriate negative pressure level for the best prognosis of patients.Methods:This was a randomized controlled clinical study. Patients who underwent prosthetic augmentation mammoplasty through inframammary fold incision in the Medical Beauty Center of the First Affiliated Hospital of Zhengzhou University from January 2019 to August 2021 were selected as the study subjects. Patients were divided into 4 groups by random number table method and different levels of negative pressure drainage were applied: 600 ml adjustable negative pressure drain bottle was used uniformly after operation by -80--85 kPa group, -40--60 kPa group, and -15--30 kPa group. In 0--5.2 kPa group, 300 ml drain drum was applied after operation. The criteria for drain removal was that the drain volume within 24 hours was less than 10 ml and the drainage fluid was clear. Daily drain volume, duration of drain placement, total drain volume, acceptance of the drain device and postoperative complications were recorded in the four groups. The corresponding indexes of each group were statistically analyzed by SPSS 21.0. Measurement data were expressed as Mean±SD. One-way analysis of variance was used for comparison between groups, and LSD- t test was used for pair comparison between groups. P<0.05 was considered statistically significant. Results:A total of 80 patients were included, 20 in each group. Inter-group equilibrium analysis: there was no significant difference in age, body mass index, distance from midclavicular point to nipple, distance from inferior mammary fold to nipple, and breast tissue thickness among 4 groups ( P>0.05). Evaluation of curative effect between groups: on the first and second day after operation, there was no significant difference in drain volume between -80--85 kPa group and -40--60 kPa group ( P>0.05), but there was significant difference among other groups ( P<0.05). There was significant difference in drain volume on the third day after operation, total drain volume and duration of drain placement between the four groups ( P<0.05). The lower the negative pressure level was, the less drain volume on the third day after surgery and the less total drain volume, and the shorter duration of drain placement. The duration of drain placement of the four groups were (5.6±0.7) d (-80--85 kPa group), (4.8±0.5) d (-40--60 kPa group), (4.0±0.5) d (-15--30 kPa group), and (3.2±0.4) d (0--5.2 kPa group), respectively. Safety evaluation: the complication rate of -80--85 kPa group, -40--60 kPa group, -15--30 kPa group and 0--5.2 kPa group were 2.5% (1/40), 2.5% (1/40), 0(0/40) and 15.0% (6/40), respectively. The complication rate of 0--5.2 kPa group was the highest. Investigation on the acceptance of the drainage device (no impact/dissatisfaction): 75 patients expressed dissatisfaction, with a dissatisfaction rate of 93.75%(75/80). Conclusion:In augmentation mammoplasty through inferior fold incision low negative pressure provides less drain volume, shorter drain placement. Negative pressure between -15 to -30 kPa is optimal.
10.Effect of negative pressure level on drain volume and prognosis of patients after prosthetic augmentation mammoplasty through inframammary fold incision
Haiyang ZHAO ; Ximei WANG ; Haijiang DONG ; Zhibin LI ; Baihui XIE ; Chengxiang YAN
Chinese Journal of Plastic Surgery 2023;39(4):375-383
Objective:To investigate the effect of different negative pressure level on drain volume after augmentation mammoplasty through inframammary fold incision, and try to put forward the appropriate negative pressure level for the best prognosis of patients.Methods:This was a randomized controlled clinical study. Patients who underwent prosthetic augmentation mammoplasty through inframammary fold incision in the Medical Beauty Center of the First Affiliated Hospital of Zhengzhou University from January 2019 to August 2021 were selected as the study subjects. Patients were divided into 4 groups by random number table method and different levels of negative pressure drainage were applied: 600 ml adjustable negative pressure drain bottle was used uniformly after operation by -80--85 kPa group, -40--60 kPa group, and -15--30 kPa group. In 0--5.2 kPa group, 300 ml drain drum was applied after operation. The criteria for drain removal was that the drain volume within 24 hours was less than 10 ml and the drainage fluid was clear. Daily drain volume, duration of drain placement, total drain volume, acceptance of the drain device and postoperative complications were recorded in the four groups. The corresponding indexes of each group were statistically analyzed by SPSS 21.0. Measurement data were expressed as Mean±SD. One-way analysis of variance was used for comparison between groups, and LSD- t test was used for pair comparison between groups. P<0.05 was considered statistically significant. Results:A total of 80 patients were included, 20 in each group. Inter-group equilibrium analysis: there was no significant difference in age, body mass index, distance from midclavicular point to nipple, distance from inferior mammary fold to nipple, and breast tissue thickness among 4 groups ( P>0.05). Evaluation of curative effect between groups: on the first and second day after operation, there was no significant difference in drain volume between -80--85 kPa group and -40--60 kPa group ( P>0.05), but there was significant difference among other groups ( P<0.05). There was significant difference in drain volume on the third day after operation, total drain volume and duration of drain placement between the four groups ( P<0.05). The lower the negative pressure level was, the less drain volume on the third day after surgery and the less total drain volume, and the shorter duration of drain placement. The duration of drain placement of the four groups were (5.6±0.7) d (-80--85 kPa group), (4.8±0.5) d (-40--60 kPa group), (4.0±0.5) d (-15--30 kPa group), and (3.2±0.4) d (0--5.2 kPa group), respectively. Safety evaluation: the complication rate of -80--85 kPa group, -40--60 kPa group, -15--30 kPa group and 0--5.2 kPa group were 2.5% (1/40), 2.5% (1/40), 0(0/40) and 15.0% (6/40), respectively. The complication rate of 0--5.2 kPa group was the highest. Investigation on the acceptance of the drainage device (no impact/dissatisfaction): 75 patients expressed dissatisfaction, with a dissatisfaction rate of 93.75%(75/80). Conclusion:In augmentation mammoplasty through inferior fold incision low negative pressure provides less drain volume, shorter drain placement. Negative pressure between -15 to -30 kPa is optimal.

Result Analysis
Print
Save
E-mail