1.Celastrol ameliorates atopic dermatitis by modulating Ezrin activation
Hong-Yu JIN ; Dan-Dan WANG ; Xin-Yi SONG ; Ke-Xin XU ; Guang-Hai YAN ; Liang-Chang LI
Chinese Pharmacological Bulletin 2024;40(10):1921-1930
Aim To investigate the effect of Celastrol on the expression of Ezrin in tissues and HaCaT cells of DNCB sensitisation-induced atopic dermatitis(AD)mice.Methods BALB/c mice were taken and ran-domly divided into the control,DNCB group,Celastrol 25 μg,50 μg,75 μg treatment group,and Dex group,with 8 mice in each group;HaCaT cells were induced with TNF-α and treated with 1 μmol·L-1 Celastrol and Ezrin siRNA.The thickness of the skin on the ear and back of mice was measured by a thickness gauge,and the spleen and lymph nodes of mice were taken to observe the changes.HE and toluidine blue staining were used to observe the inflammatory cells and mast cell infiltration in mice.Flow cytometry was used to detect the levels of IL-4 and TNF-α in the lymph nodes of mice,and enzyme-linked immunosorbent was used to determine the levels of IL-4,TNF-α and IgE in serum of mice,and the expression of IL-4,IL-5 and IL-13 in the supernatant of HaCaT cells.Western blot was used to detect the expression of P-Ezrin and Ezrin in skin tissues.Results Celastrol significantly inhibited the swelling of ear and back skin tissues,reduced the de-granulation of inflammatory cells and mast cells,low-ered serum IgE and serum and lymph node levels of IL-4 and TNF-α,and reduced the activation of Ezrin in mice,and the expression of IL-4,IL-5 and IL-13 in the supernatant of HaCaT cells was restored by the treat-ment with Ezrin siRNA.Conclusion Celastrol amel-iorates AD,which may be achieved by modulating Ezrin activation.
2.Correlation analysis between patient stature-based optimization of image acquisition parameters and low-dose coronary angiography
Hai QIAN ; Yu-Qin ZHANG ; Ke-Nan LOU ; De-Xing HU
Chinese Journal of Interventional Cardiology 2024;32(4):191-196
Objective To explore the correlation among image acquisition parameter optimization,coronary angiography radiation dose and image quality.Methods 60 patients scheduled for elective percutaneous coronary angiography from January 2022 to January 2024 in our hospital were selected.Basic information and body measurements were collected.Patients were divided into three groups based on BMI,and patients in each BMI group were randomly assigned to the conventional mode group(coronary mode image acquisition:Cardiac Left Coronary,15fps)and the optimized mode group(electrophysiology mode image acquisition:Cardiac EP,7.5fps).Radiation dose data were collected.Image quality was evaluated using an image quality scoring table.Independent sample t-tests,Mann-Whitney U tests,and one-way ANOVA were used for comparisons between groups.Pearson analysis was used for correlations.Results Higher BMI and larger chest circumference were associated with higher radiation doses in a positive linear correlation.Within each BMI group,all radiation dose data(Dose-Area Product,Air Kerma and Chest skin dose)were lower in the optimized mode group than in the conventional mode group(all P<0.05,reduction rate 48.95%-70.59%).The difference in image quality scores between two groups was not statistically significant(P>0.05),and all images were of the required quality.Conclusions The radiation dose of percutaneous coronary angiography is affected by the patient's body size,image acquisition parameters,exposure time and many other factors.Optimizing the image acquisition parameters can ensure the quality of the image while realizing the low dose of radiation and reducing the radiation hazards to the patient and the operator.
3.Porcine SIRT5 promotes replication of foot and mouth disease virus type O in PK-15 cells
Guo-Hui CHEN ; Xi-Juan SHI ; Xin-Tian BIE ; Xing YANG ; Si-Yue ZHAO ; Da-Jun ZHANG ; Deng-Shuai ZHAO ; Wen-Qian YAN ; Ling-Ling CHEN ; Mei-Yu ZHAO ; Lu HE ; Hai-Xue ZHENG ; Xia LIU ; Ke-Shan ZHANG
Chinese Journal of Zoonoses 2024;40(5):421-429
The effect of porcine SIRT5 on replication of foot and mouth disease virus type O(FMDV-O)and the underlying regulatory mechanism were investigated.Western blot and RT-qPCR analyses were employed to monitor expression of endoge-nous SIRT5 in PK-15 cells infected with FMDV-O.Three pairs of SIRT5-specific siRNAs were synthesized.Changes to SIRT5 and FMDV-O protein and transcript levels,in addition to virus copy numbers,were measured by western blot and RT-qPCR analyses.PK-15 cells were transfected with a eukaryotic SIRT5 expression plasmid.Western blot and RT-qPCR analyses were used to explore the impact of SIRT5 overexpression on FMDV-O replication.Meanwhile,RT-qPCR analysis was used to detect the effect of SIRT5 overexpression on the mRNA expression levels of type I interferon-stimulated genes induced by SeV and FMDV-O.The results showed that expression of SIRT5 was up-regulated in PK-15 cells infected with FMDV-O and siRNA interfered with SIRT5 to inhibit FMDV-O replication.SIRT5 overexpression promoted FMDV-O replication.SIRT5 over-expression decreased mRNA expression levels of interferon-stimulated genes induced by SeV and FMDV-O.These results suggest that FMDV-O infection stimulated expression of SIRT5 in PK-15 cells,while SIRT5 promoted FMDV-O rep-lication by inhibiting production of type I interferon-stimula-ted genes.These findings provide a reference to further ex-plore the mechanism underlying the ability of porcine SIRT5 to promote FMDV-O replication.
4.Genomic characteristics of the Vibrio cholerae O1 group isolated from humans in Fujian Province,2008 to 2022
Zi-Li KE ; Xiao-Xuan ZHANG ; Hai-Bin XU ; Ya-Dong GAO ; Chao-Chen LUO ; Meng-Ying HUANG ; Yu-Feng QIU ; Jin-Song YANG
Chinese Journal of Zoonoses 2024;40(8):708-715
This study was aimed at understanding the genomic characteristics of the Vibrio cholerae O1 group isolated from humans in Fujian Province,to provide essential data for the molecular epidemiological study of cholera.From 2008 to 2022,16 strains of the V.cholerae O1 group from patients and carriers were collected,and antibiotic sensitivity was determined accord-ing to the minimum inhibitory concentration(MIC).The whole genome sequences obtained through second generation sequen-cing were analyzed in open source software,including snippy,Roary,and Prokka,as well as online analysis websites,inclu-ding NCBI and BacWGSTdb,for core-genome multilocus sequence typing(cgMLST),core-genome single nucleotide polymor-phism analysis(cgSNP),virulence gene analysis,drug resistance gene prediction,and pan-genomic diversity analysis.The whole genome sequences of V.cholerae were divided into five sequence types(STs),among which the newly discovered ST182 and ST1480 were the evolutionary branches of the current dominant clonal group ST75 in China,and were highly related to two strains isolated from Taiwan in 2010 and 2013,respectively.Both toxigenic strains and non-toxigenic strains carried a variety of virulence factors and showed gene variation to varying degrees.Thirteen drug resistance genes in seven categories were predicted,among which the distribution of colistin and tetracycline resistance genes was consistent with the drug resistance phenotype.Pan-ge-nomic analysis indicated that V.cholerae had an open pan-genome,and Roary cluster analysis showed higher resolution than cgMLST.In summary,V.cholerae O1 group isolates from humans in Fujian Province have polymorphisms in genome structure and function,and the newly discovered ST1480 clone group has epidemic potential.Therefore,the monitoring of such strains must be strengthened.
5.Distribution and Drug Resistance of Pathogens Causing Bloodstream Infection in Patients with Hematological Malignancies
Ming YANG ; Huai-Xin GENG ; Jin-Ge TAI ; Hai-Lian SHAO ; Jing-Wen CHEN ; Ke DONG
Journal of Experimental Hematology 2024;32(2):583-587
Objective:To investigate distribution and drug resistance of pathogens of bloodstream infection in patients with hematological malignancies,in order to provide reference for clinical infection control and treatment.Methods:The clinical information of blood culture patients in the hematology department of our hospital from January 2016 to December 2021 was reviewed.They were divided into transplantation group and non-transplantation group according to whether they had undergone hematopoietic stem cell transplantation.The types of pathogens and their drug resistance were analyzed.Results:Two hundred and ninety-nine positive strains of pathogenic bacteria were detected.In the transplantation group,Gram-negative bacteria accounted for 68.5%(50/73),Gram-positive bacteria accounted for 6.8%(5/73),and fungi accounted for 24.7%(18/73).The resistance rate of Escherichia coli to the third-generation cephalosporins was 77.8%,and 11.5%to carbapenems.The resistance rate of Klebsiella pneumoniae to the third-generation cephalosporins was 50.0%,and 56.2%to carbapenems.In the non-transplantation group,Gram-negative bacteria accounted for 64.1%(145/226),Gram-positive bacteria accounted for 31.0%(70/226),and fungi accounted for 4.9%(11/226).Gram-positive bacteria were mainly Enterococcus faecium(6.6%,15/226)and Coagulase-negative Staphylococci(6.2%,14/226).The fungi were all Candida tropicalis.The resistance rate of Escherichia coli to the third-generation cephalosporins was 63.8%,and 10.3%to carbapenems.The resistance rate of Klebsiella pneumoniae to the third-generation cephalosporins was 46.3%,and 26.8%to carbapenems.Conclusion:The types of pathogenic bacteria in bloodstream infection in patients with hematological malignancies are varied.Gram-negative bacteria is the main pathogenic bacteria.The resistance of pathogenic bacteria to antibiotics is severe.Antibiotics should be used scientifically and reasonably according to the detection and resistance of pathogenic bacteria.
6.Clinical Characteristics of CD4-CD56+Blastic Plasmacytoid Dendritic Cell Neoplasm
He-Sheng HE ; Yuan-Feng WEI ; Xin-Yue JI ; You-Hai XU ; Yu-Qiong YANG ; Xiao-Ke JIN
Journal of Experimental Hematology 2024;32(2):588-594
Objective:To explore the clinical manifestations,pathological features,immunophenotype,as well as diagnosis,treatment and prognosis of patients with CD4-CD56+blastic plasmacytoid dendritic cell neoplasm(BPDCN),in order to further understand the rare disease.Methods:The clinical data,laboratory examinations and treatment regimens of two patients with CD4-CD56+BPDCN in the First Affiliated Hospital of Wannan Medical College were retrospectively analyzed.Results:The two patients were both elderly males with tumor involved in skin,bone marrow,lymph nodes,etc.Immunohistochemical results of skin lesions showed that both CD56 and CD123 were positive,while CD4,CD34,TdT,CD3,CD20,MPO and EBER were negative.Flow cytometry of bone marrow demonstrated that CD56,CD123,and CD304 were all positive,while specific immune markers of myeloid and lymphoid were negative.Two patients were initially very sensitive to acute lymphoblastic leukemia or lymphomatoid chemotherapy regimens,but prone to rapid relapse.The overall survival of both patients was 36 months and 4 months,respectively.Conclusion:CD4-CD56+BPDCN is very rare and easily misdiagnosed as other hematological tumors with poor prognosis.Acute lymphoblastic leukemia or lymphomatoid therapy should be used first to improve the poor prognosis.
7.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]
8.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]
9.Design and implementation of nuclear emergency medical rescue simulation platform based on VR and AR technologies
Ke-Xian LI ; Hai-Jun WANG ; Ying HE
Chinese Medical Equipment Journal 2024;45(9):50-56
Objective To design a nuclear emergency medical rescue simulation platform to solve the problmes in nuclear accident scenario simulation,fidelity of on-site medical treatment training and training organization.Methords A nuclear emergency medical rescue simulation platform was developed with the technologies of virtual reality(VR),augmented reality(AR),spatial positioning,full-body motion capture,gesture simulation and three-dimensional modeling,Unity3D platform,3D Studio Max software and Visual Studio,which mainly consisted of a hardware system and a software system.The hardware system was composed of the AR training equipment and VR training equipment,of which,the AR training equipment included a surface contamination detector simulator,an individual decontaminator simulator and AR glasses,and the VR training equipment was made up of VR glasses,large-space localization equipment,backpack computers,data gloves and full-body motion capture equipment.The software system involved in several modules for theoretical knowledge teaching and assessment,VR/AR practical teaching training and VR/AR evaluation.Results The system realized simulated collaborative training and evaluation for medical emergency response to nuclear accidents.Conclusion The platform constructed contributes to solving the practical problems in organizing and implementing education and training for nuclear emergency medical rescue,and the education and training are both enhanced greatly.[Chinese Medical Equipment Journal,2024,45(9):50-56]
10.Design of emergency medical rescue information system based on microservices architecture
Jun-Jun WANG ; Xin ZHANG ; Ke-Yu FANG ; Hai-Long SI ; Xiao-Li QIN ; Ping CHEN
Chinese Medical Equipment Journal 2024;45(10):41-48
Objective To design an emergency medical rescue information system to ensure that emergency medical rescue institutions and teams at all levels can quickly access system support under emergency rescue conditions.Methods The emergency medical rescue information system was built with Browser/Server(B/S)architecture,microservices architecture,Java,JavaScript,Spring Boot,Spring Cloud and Alibaba framework,which used MySQL relational database,Redis cache database and Elasticsearch search engine for data storage and management.There were five functional modules involved in the system including the modules for triage,medical treatment,medical technical support,medical evacuation and command and management.Results The system developed behaved well in rapid deployment and response,and realized quick collection of casualty information and enhanced the efficiency and accuracy of casualty triage.Conclusion The system developed can be used in multi rescue scenarios to meet different requirements,which provides information system support for multi emergency medical rescue institutions and teams.[Chinese Medical Equipment Journal,2024,45(10):41-48]

Result Analysis
Print
Save
E-mail