1.Screening and influencing factors analysis of myopia in children and adolescent in Wulong district of Chongqing
Huabin ZHENG ; Ting XIAO ; Ji LI ; Qirong HUANG ; Zhi ZHOU
International Eye Science 2025;25(2):297-300
AIM:To investigate myopia status and analyze the influence factors in children and adolescent in Wulong district of Chongqing.METHODS:Cross-sectional study. A stratified cluster sampling method was used to select 2 504 primary and secondary school students in Wulong district, and all students underwent myopia screen and questionnaire survey, statistics and analyses the data.RESULTS:Totally 2 431 students were participated in this study, and 1 217 students with myopia were screened out, the prevalence rate of myopia was 50.06%, awareness rate of myopia was 64.59%, glasses wearing rate of myopia was 51.85%. The prevalence of myopia increased with age and grade(P<0.05), the prevalence of myopia in male(46.97%)was lower than in female(53.18%), and the prevalence of myopia in township(47.06%)was lower than in urban area(52.11%; all P<0.05). Regression analysis showed that outdoor activities were protective factor for myopia, while female, myopic parents, near vision work, short sleep duration and sweet tooth were risk factors for myopia.CONCLUSION:The prevalence rate of myopia was higher in children and adolescent in Wulong district of Chongqing, awareness rate of myopia and glasses wearing rate of myopia were lower, and the genesis of myopia is highly relevant to outdoor activities, gender, myopic parents, near vision work, short sleep duration and sweet tooth.
2.Applications of Vaterite in Drug Loading and Controlled Release
Xiao-Hui SONG ; Ming-Yu PAN ; Jian-Feng XU ; Zheng-Yu HUANG ; Qing PAN ; Qing-Ning LI
Progress in Biochemistry and Biophysics 2025;52(1):162-181
Currently, the drug delivery system (DDS) based on nanomaterials has become a hot interdisciplinary research topic. One of the core issues is drug loading and controlled release, in which the key lever is carriers. Vaterite, as an inorganic porous nano-material, is one metastable structure of calcium carbonate, full of micro or nano porous. Recently, vaterite has attracted more and more attention, due to its significant advantages, such as rich resources, easy preparations, low cost, simple loading procedures, good biocompatibility and many other good points. Vaterite, gained from suitable preparation strategies, can not only possess the good drug carrying performance, like high loading capacity and stable loading efficiency, but also improve the drug release ability, showing the better drug delivery effects, such as targeting release, pH sensitive release, photothermal controlled release, magnetic assistant release, optothermal controlled release. At the same time, the vaterite carriers, with good safety itself, can protect proteins, enzymes, or other drugs from degradation or inactivation, help imaging or visualization with loading fluorescent drugs in vitro and in vivo, and play synergistic effects with other therapy approaches, like photodynamic therapy, sonodynamic therapy, and thermochemotherapy. Latterly, some renewed reports in drug loading and controlled release have led to their widespread applications in diverse fields, from cell level to clinical studies. This review introduces the basic characteristics of vaterite and briefly summarizes its research history, followed by synthesis strategies. We subsequently highlight recent developments in drug loading and controlled release, with an emphasis on the advantages, quantity capacity, and comparations. Furthermore, new opportunities for using vaterite in cell level and animal level are detailed. Finally, the possible problems and development trends are discussed.
3.Development of a RP scoring system for predicting perioperative outcomes in robot-assisted partial nephrectomy by optimizing RENAL and MAP scores
Liang ZHENG ; Bohong CHEN ; Haoxiang HUANG ; Cong FENG ; Jin ZENG ; Wei CHEN ; Dapeng WU
Journal of Modern Urology 2025;30(1):53-58
[Objective] To establish a new scoring system to predict the perioperative outcomes (operation time, intraoperative blood loss, and trifecta achievement) in patients undergoing robot-assisted partial nephrectomy (RAPN) by integrating the RENAL and Mayo adhesive probability (MAP) scores. [Methods] Clinical data of 178 patients with renal cell carcinoma who underwent RAPN performed by the same surgeon in our hospital during Jan.2015 and Jan.2022 were retrospectively analyzed.The RENAL and MAP scores of all patients were calculated.Linear regression and logistic regression were used to evaluate the associations between the components of the RENAL and MAP scores (a total of 6 variables) and perioperative outcomes.The factors with significant associations were then included into logistic regression analysis to identify independent predictors for constructing an assessment system for perioperative outcomes, and the receiver operating characteristic (ROC) curve was plotted to calculate the area under the curve (AUC) to predict its efficacy. [Results] Multivariate linear regression analysis showed that tumor size (β=6.14, 95%CI: 1.93—10.34, P=0.004), exophytic rate (β=10.60, 95%CI: 3.44—17.76, P=0.004), and perinephric fat thickness (β=16.48, 95%CI: 8.52—24.45, P<0.001) were significantly associated with operation time.Tumor size (β=10.55 95%CI: 5.60—15.49, P<0.001) was associated with both intraoperative blood loss and trifecta achievement (OR=1.73, 95%CI: 1.26—2.36, P=0.001). Multivariate logistic regression analysis of these 3 factors identified tumor size (OR=9.07, 95% CI: 1.18—69.45, P=0.03) and perinephric fat thickness (OR=2.28, 95%CI: 1.86—6.04, P=0.01) as independent predictors of perioperative outcomes.Based on these findings, the tumor size and perinephric fat thickness (RP) scoring was constructed, which demonstrated better predictive ability than RENAL score or MAP score alone (RP vs.RENAL vs.MAP: 0.766 vs.0.548 vs.0.684). [Conclusion] The RP score includes fewer variables than the RENAL and MAP scores but outperforms them.
4.Research progress of super-pulse fiber thulium laser lithotripsy
Tianfu DING ; Zhongyue HUANG ; Zheng XU ; Jianxing LI
Journal of Modern Urology 2025;30(1):82-85
Super-pulse thulium fiber laser (hereinafter referred to as thulium laser) has shown broad application prospects in medical research, especially in the treatment of urinary tract stones.Thulium laser has a thin fiber diameter, which reduces the occupation of the working channel and increases the irrigation water flow.Currently, the peak power reaches up to 500 W, the single pulse energy to 6 J, and the frequency to 2000 Hz.The stone-breaking mechanism of thulium laser is photothermal and photomechanical.Different combinations of energy and frequency will significantly affect the volume of stone fragments. "High energy and low frequency" is more suitable for "fragmentation" stone breaking, while "low energy and high frequency" is more suitable for "powderization" stone breaking.Some in vitro experiments have confirmed that thulium laser has higher stone-breaking efficiency, less stone displacement, and more obvious thermal effects compared to holmium laser.Clinically, thulium laser has been applied to ureteroscopic lithotripsy and percutaneous nephrolithotomy., and the stone free rate and safety are relatively high.This article reviews the stone-breaking principles, in vitro experiments, and clinical applications of thulium laser, aiming to provide better theoretical support and practical experience for the development and application of super-pulse thulium fiber laser in the future.
5.The Establishment of a Virus-related Lymphoma Risk Warning System and Health Management Model Based on Traditional Chinese Medicine Conditions
Hanjing LI ; Shunan LI ; Zewei ZHUO ; Shunyong WANG ; Qiangqiang ZHENG ; Bingyu HUANG ; Yupeng YANG ; Chenxi QIU ; Ningning CHEN ; He WANG ; Tingbo LIU ; Haiying FU
Journal of Traditional Chinese Medicine 2025;66(4):335-339
Virus-related lymphoma exhibits a dual nature as both a hematologic malignancy and a viral infectious disease, making it more resistant to treatment and associated with poorer prognosis. This paper analyzes the understanding and therapeutic advantages of traditional Chinese medicine (TCM) in virus-related lymphoma. It proposes a TCM-based approach centered around syndrome differentiation, using standardized measurements of the overall TCM condition, multi-omics research of hematologic tumors, and artificial intelligence technologies to identify the "pre-condition" of virus-related lymphoma. A risk warning model will be established to early identify high-risk populations with viral infections that may develop into malignant lymphoma, thereby establishing a risk warning system for virus-related lymphoma. At the same time, a TCM health management approach will be applied to manage and regulate virus-related lymphoma, interrupting its progression and forming a human-centered, comprehensive, continuous health service model. Based on this, a standardized, integrated clinical prevention and treatment decision-making model for virus-related lymphoma, recognized by both Chinese and western medicine, will be established to provide TCM solutions for primary prevention of major malignant tumors.
6.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
7.Evaluation on repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure
Yue PENG ; Ping ZHAO ; Juan TAN ; Rui LIU ; Yiping ZHENG ; Jiangping HUANG
International Eye Science 2025;25(3):494-498
AIM: To evaluate the repeatability and accuracy of iCare IC100 tonometer in measuring intraocular pressure(IOP)by comparing the correlation and difference with Goldmann applanation tonometry(GAT)and non-contact tonometer(NCT), and to compare the correlation of the three types of IOP measurement with the central corneal thickness(CCT).METHODS: Prospective study. A total of 90 outpatients(90 eyes)in Liaoning Aier Eye Hospital from March 2019 to May 2019 were randomly selected as study subjects. All patients were measured IOP using iCare IC100, NCT, and GAT. The interclass correlation coefficient(ICC)was used to evaluate the repeatability of IOP measured 3 times consecutively using an intraocular tonometer. The correlation and consistency of iCare IC100, GAT and NCT were compared by one-way ANOVA, Pearson linear correlation analysis and Bland-Altman analysis. The linear regression analysis was used to analyze the correlation of the three tonometers with CCT.RESULTS: The mean IOP measured with iCare IC100, GAT and NCT was 19.74±6.90, 19.88±7.07 and 18.47±6.31 mmHg, respectively(F=1.180, P=0.309). The measurements of iCare IC100 with GAT, iCare IC100 with NCT and GAT with NCT were all positively correlated(r=0.930, 0.946, 0.918, all P<0.05), the Bland-Altman analysis showed that the mean differences between iCare IC100 and GAT, iCare IC100 and NCT, GAT and NCT were -0.142±2.61, 1.27±2.24, and 1.41±2.81 mmHg, respectively, with 97%(87/90), 96%(86/90), and 97%(87/90)IOP differences distributed within their 95% confidence intervals. The IOP measured with iCare IC100 and CCT, GAT and CCT and NCT and CCT were all positively correlated(r=0.426, 0.353, 0.451, all P<0.01). The linear regression equations between iCare IC100, GAT and NCT measurement and CCT were iCare IC100 IOP=-19.62+0.074×CCT; GAT IOP=-13.54+0.063×CCT; NCT IOP=-19.65+0.072×CCT; that is, for every 10 μm increase in CCT, iCare IC100 measurement increased by 0.74 mmHg, GAT measurement increased by 0.63 mmHg, and NCT measurement increased by 0.72 mmHg.CONCLUSION: The iCare IC100 tonometer has good repeatability and accuracy in measuring IOP, and the CCT has a greater impact on the measurement of iCare IC100 than the GAT and NCT.
8.Standardization of electronic medical records data in rehabilitation
Yifan TIAN ; Fang XUN ; Haiyan YE ; Ye LIU ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):33-44
ObjectiveTo explore the data standard system of electronic medical records in the field of rehabilitation, focusing on the terminology and coding standards, data structure, and key content categories of rehabilitation electronic medical records. MethodsBased on the Administrative Norms for the Application of Electronic Medical Records issued by the National Health Commission of China, the electronic medical record standard architecture issued by the International Organization for Standardization and Health Level Seven (HL7), the framework of the World Health Organization Family of International Classifications (WHO-FICs), Basic Architecture and Data Standards of Electronic Medical Records, Basic Data Set of Electronic Medical Records, and Specifications for Sharing Documents of Electronic Medical Records, the study constructed and organized the data structure, content, and data standards of rehabilitation electronic medical records. ResultsThe data structure of rehabilitation electronic medical records should strictly follow the structure of electronic medical records, including four levels (clinical document, document section, data set and data element) and four major content areas (basic information, diagnostic information, intervention information and cost information). Rehabilitation electronic medical records further integrated information related to rehabilitation needs and characteristics, emphasizing rehabilitation treatment, into clinical information. By fully applying the WHO-FICs reference classifications, rehabilitation electronic medical records could establish a standardized framework, diagnostic criteria, functional description tools, coding tools and terminology index tools for the coding, indexing, functional description, and analysis and interpretation of diseases and health problems. The study elaborated on the data structure and content categories of rehabilitation electronic medical records in four major categories, refined the granularity of reporting rehabilitation content in electronic medical records, and provided detailed data reporting guidance for rehabilitation electronic medical records. ConclusionThe standardization of rehabilitation electronic medical records is significant for improving the quality of rehabilitation medical services and promoting the rehabilitation process of patients. The development of rehabilitation electronic medical records must be based on the national and international standards. Under the general electronic medical records data structure and standards, a rehabilitation electronic medical records data system should be constructed which incorporates core data such as disease diagnosis, functional description and assessment, and rehabilitation interventions. The standardized rehabilitation electronic medical records scheme constructed in this study can support the improvement of standardization of rehabilitation electronic medical records data information.
9.Standardization of outpatient medical record in rehabilitation setting
Ye LIU ; Qing QIN ; Haiyan YE ; Yifan TIAN ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):45-54
ObjectiveTo analyze the data structure and standards of rehabilitation outpatient medical records, to provide data support for improving the quality of rehabilitation outpatient care and developing medical insurance payment policies. MethodsBased on the normative documents issued by the National Health Commission, Basic Standards for Medical Record Writing and Standards for Electronic Medical Record Sharing Documents, in accordance with the Quality Management Regulations for Outpatient (Emergency) Diagnosis and Treatment Information Pages (Trial), reference to the framework of the World Health Organization Family of International Classifications (WHO-FICs), the data framework and content of rehabilitation outpatient medical records were determined, and the data standards were discussed. ResultsThis study constructed a data framework for rehabilitation outpatient medical records, including four main components: patient basic information, visit process information, diagnosis and treatment information, and cost information. Three major reference classifications of WHO-FICs, International Classification of Diseases, International Classification of Functioning, Disability and Health, and International Classification of Health Interventions,were used to establish diagnostic standards and standardized terminology, as well as coding disease diagnosis, functional description, functional assessment, and rehabilitation interventions, to improve the quality of data reporting, and level of quality control in rehabilitation. ConclusionThe structuring and standardization of rehabilitation outpatient medical records are the foundation for sharing of rehabilitation data. The using of the three major classifications of WHO-FICs is valuable for the terminology and coding of disease diagnosis, functional description and assessment, and intervention in rehabilitation outpatient medical records, which is significant for sharing and interconnectivity of rehabilitation outpatient data, as well as for optimizing the quality and safety of rehabilitation medical services.
10.Structure, content and data standardization of inpatient rehabilitation medical record summary sheet
Haiyan YE ; Qing QIN ; Ye LIU ; Yifan TIAN ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):55-66
ObjectiveTo explore the standardization of inpatient rehabilitation medical record summary sheet, encompassing its structure, content and data standards, to enhance the standardization level of inpatient rehabilitation medical record summary sheet, improve data reporting quality, and provide accurate data support for medical insurance payment, hospital performance evaluation, and rehabilitation discipline evaluation. MethodsBased on the relevant specifications of the National Health Commission's Basic Norms for Medical Record Writing, Specifications for Sharing Documents of Electronic Medical Records, and Quality Management and Control Indicators for Inpatient Medical Record Summary Sheet (2016 Edition), this study analyzed the structure and content of the inpatient rehabilitation medical record summary sheet. The study systematically applied the three major reference classifications of the World Health Organization Family of International Classifications, International Classification of Diseases (ICD-10/ICD-11, ICD-9-CM-3), International Classification of Functioning, Disability and Health (ICF), and International Classification of Health Interventions (ICHI Beta-3), for disease diagnosis, functional description and assessment, and rehabilitation intervention, forming a standardized terminology system and coding methods. ResultsThe inpatient rehabilitation medical record summary sheet covered four major sections: inpatient information, hospitalization information, diagnosis and treatment information, and cost information. ICD-10/ICD-11 were the standards and coding tools for admission and discharge diagnoses in the inpatient rehabilitation medical record summary sheet. The three functional assessment tools recommended by ICD-11, the 36-item version of World Health Organization Disability Assessment Schedule 2.0, Brief Model Disability Survey and Generic Functioning domains, as well as ICF, were used for rehabilitation functioning assessment and the coding of outcomes. ICHI Beta-3 and ICD-9-CM-3 were used for coding surgical procedures and operations in the medical record summary sheet, and also for coding rehabilitation intervention items. ConclusionThe inpatient rehabilitation medical record summary sheet is a summary of the relevant content of the rehabilitation medical record and a tool for reporting inpatient rehabilitation data. It needs to be refined and optimized according to the characteristics of rehabilitation, with necessary data supplemented. The application of ICD-11/ICD-10, ICF and ICHI Beta-3/ICD-9-CM-3 classification standards would comprehensively promote the accuracy of inpatient diagnosis of diseases and functions. Based on ICD-11 and ICF, relevant functional assessment result data would be added, and ICHI Beta-3/ICD-9-CM-3 should be used to code rehabilitation interventions. Improving the quality of rehabilitation medical records and inpatient rehabilitation medical record summary sheet is an important part of rehabilitation quality control, and also lays an evidence-based data foundation for the analysis and application of inpatient rehabilitation medical record summary sheet.

Result Analysis
Print
Save
E-mail