1.A primary study on the establishment of a low-titer group O whole blood donor bank
Hang YU ; Yanglin ZHUANG ; Yuanqin ZHANG ; Huaqing HE ; Huiqing HUANG
Chinese Journal of Blood Transfusion 2026;39(4):513-518
Objective: To investigate and analyze the IgM/IgG antibody titer levels and population characteristics of local type O blood donors, and to provide data support for the establishment of a low-titer group O blood donor bank. Methods: Whole blood samples were collected from 527 type O blood donors. The agglutination of IgM and IgG anti-A/anti-B antibodies at titers 64 and 128 was assessed using an enzyme immunoassay reader. The distribution of antibody agglutination was displayed using GraphPad Prism 9.5. Statistical analysis was performed to compare antibody agglutination differences among donors of different genders, age groups, and donation frequencies. Results: At a titer of 64, the non-agglutination rate of IgM anti-A/anti-B was 71.35%, and that of IgG anti-A/anti-B was 54.46%. At a titer of 128, the non-agglutination rate of IgM anti-A/anti-B was 83.68%, and that of IgG anti-A/anti-B was 70.21%. At a titer of 64, the agglutination rate of IgM anti-B was significantly higher in female donors than in male donors (23.08% vs 13.71%, P<0.05). The agglutination rates of IgM anti-A/anti-B at a titer of 64 decreased with age in different age groups (anti-A: 26.22% vs 18.28% vs 8.49%; anti-B: 19.82% vs 11.83% vs 5.66%, P<0.05). The agglutination rates of IgM anti-A/anti-B at a titer of 64 were both higher in first-time donors than in repeat donors (anti-A: 24.00% vs 15.82%; anti-B: 18.00% vs 10.73%, P<0.05). The agglutination rate of IgG anti-A at a titer of 128 was higher in first-time donors than in repeat donors (26.57% vs 6.21%, P<0.05). Conclusion: The establishment of a low-titer type O whole blood donor bank should primarily target males, donors aged>30 years and repeat donors, with both IgM and IgG antibodies included in the antibody testing scope.
2.Combined screening of two primary immunodeficiency diseases and spinal muscular atrophy in neonates by multiplex real-time fluorescence quantitative PCR
Chao ZHANG ; Jianbin YANG ; Shiqiang SHANG ; Chi CHEN ; Huaqing MAO ; Xiaolei HUANG ; Fang HONG ; Haixia MIAO ; Hanyi ZHAO ; Rulai YANG
Chinese Journal of Laboratory Medicine 2025;48(2):249-257
Objective:To explore the feasibility of joint screening of the two primary immunodeficiency diseases [severe combined immunodeficiency (SCID) and X-linked agammaglobulinemia(XLA)] and spinal muscular atrophy(SMA) in newborns by multiplex real-time quantitative PCR technology, and to provide evidence for early screening, diagnosis and treatment of children.Methods:Cross-sectional study. From July 2021 to January 2023, a total of 103 240 dry blood spots samples of newborns were collected which were delivered to Neonatal Disease Screening Center of Zhejiang by cold chain transportation. The concentrations of the T cell receptor excision ring (TREC), Kappa deletion of the recombinant excision loop (KREC), and exon 7 deletion of Survival Motor Neuron 1 (SMN1) gene in dry blood spots were simultaneously detected by multiplex real-time fluorescence quantitative PCR, taken ribonuclease P/MRP 30 000 subunits (RPP30) as an internal reference gene. The positive newborns were further diagnosed by other laboratory tests and gene sequencing was taken as gold standard. Children samples from 1 case of SCID, 3 cases of XLA and 2 cases of SMA were used for positive verification. The correlation between detected concentration of TREC/KREC and basic information in newborns were analyzed. The differences among groups for each factor were analyzed.Results:One case of SCID, 2 cases of XLA, 9 cases of SMA and 7 cases of other genetic diseases (4 cases of DiGeorge syndrome, 1 case of trisomy 21 syndrome, 1 case of Noonan syndrome and 1 case of super male syndrome) were identified by multiplex real-time fluorescence quantitative PCR. The positive predictive values of screening neonatal SCID, XLA and SMA were 2.44% (1/41), 2.78% (2/72) and 9/9 respectively. Taking the samples from clinically diagnosed 1 case of SCID, 3 cases of XLA and 2 cases of SMA as positive validation samples, which were all identified. The detected results of TREC/KREC correlated with time of blood collection, sex, weight, gestational age and delivery mode of newborns, whose r values were 0.162/0.187, 0.066/0.032, 0.045/0.042, ?0.015/?0.088 and 0.014/0.068 respectively (all P<0.05). Conclusions:Relying on current neonatal screening platform in Zhejiang, it is feasible to screen jointly two kinds of primary immunodeficiency diseases and spinal muscular atrophy in newborns by multiple real-time fluorescence quantitative PCR technology.
3.Combined screening of two primary immunodeficiency diseases and spinal muscular atrophy in neonates by multiplex real-time fluorescence quantitative PCR
Chao ZHANG ; Jianbin YANG ; Shiqiang SHANG ; Chi CHEN ; Huaqing MAO ; Xiaolei HUANG ; Fang HONG ; Haixia MIAO ; Hanyi ZHAO ; Rulai YANG
Chinese Journal of Laboratory Medicine 2025;48(2):249-257
Objective:To explore the feasibility of joint screening of the two primary immunodeficiency diseases [severe combined immunodeficiency (SCID) and X-linked agammaglobulinemia(XLA)] and spinal muscular atrophy(SMA) in newborns by multiplex real-time quantitative PCR technology, and to provide evidence for early screening, diagnosis and treatment of children.Methods:Cross-sectional study. From July 2021 to January 2023, a total of 103 240 dry blood spots samples of newborns were collected which were delivered to Neonatal Disease Screening Center of Zhejiang by cold chain transportation. The concentrations of the T cell receptor excision ring (TREC), Kappa deletion of the recombinant excision loop (KREC), and exon 7 deletion of Survival Motor Neuron 1 (SMN1) gene in dry blood spots were simultaneously detected by multiplex real-time fluorescence quantitative PCR, taken ribonuclease P/MRP 30 000 subunits (RPP30) as an internal reference gene. The positive newborns were further diagnosed by other laboratory tests and gene sequencing was taken as gold standard. Children samples from 1 case of SCID, 3 cases of XLA and 2 cases of SMA were used for positive verification. The correlation between detected concentration of TREC/KREC and basic information in newborns were analyzed. The differences among groups for each factor were analyzed.Results:One case of SCID, 2 cases of XLA, 9 cases of SMA and 7 cases of other genetic diseases (4 cases of DiGeorge syndrome, 1 case of trisomy 21 syndrome, 1 case of Noonan syndrome and 1 case of super male syndrome) were identified by multiplex real-time fluorescence quantitative PCR. The positive predictive values of screening neonatal SCID, XLA and SMA were 2.44% (1/41), 2.78% (2/72) and 9/9 respectively. Taking the samples from clinically diagnosed 1 case of SCID, 3 cases of XLA and 2 cases of SMA as positive validation samples, which were all identified. The detected results of TREC/KREC correlated with time of blood collection, sex, weight, gestational age and delivery mode of newborns, whose r values were 0.162/0.187, 0.066/0.032, 0.045/0.042, ?0.015/?0.088 and 0.014/0.068 respectively (all P<0.05). Conclusions:Relying on current neonatal screening platform in Zhejiang, it is feasible to screen jointly two kinds of primary immunodeficiency diseases and spinal muscular atrophy in newborns by multiple real-time fluorescence quantitative PCR technology.
4.Preparation and in Vitro Evaluation of a Self-Microemulsifying Drug Delivery System for Insoluble Drug Nebivolol Hydrochloride
Mingzhi XU ; Yucheng CHEN ; Tingyu XIAO ; Lili HUANG ; Huaqing LIN
Chinese Journal of Modern Applied Pharmacy 2024;41(9):1214-1221
OBJECTIVE
To prepare a self-microemulsifying drug delivery system(SMEDDS) for the oral administration of nebivolol hydrochloride(NBH) and to conduct in vitro evaluation.
METHODS
The solubility of NBH was determined using various oil phases, surfactants, and co-surfactants. The composition of the blank self-microemulsifying formulation was determined using pseudo-ternary phase diagrams. A centralcomposite design-response surface method was employed to screen and optimize the formulation variables, and an excess amount of NBH raw material was incorporated to determine the drug loading capacity.
RESULTS
The optimized composition of the NBH-SMEDDS formulation consisted of medium-chain glycerides, capryl caproyl macrogol glycerides, and 2-(2-ethoxyethoxy) ethyl acetate at a ratio of 20∶48∶32, with a drug loading capacity of 20.05 mg. The particle size, self-emulsification time, and particle size distribution range of the formulation were in agreement with the predicted values. Dissolution testing demonstrated that the overall dissolution trend of NBH-SMEDDS in the medium was higher than that of NBH powder and NBH ordinary tablet. The stability of NBH-SMEDDS was found to be satisfactory under accelerated conditions for 1, 2, and 3 months.
CONCLUSION
The SMEDDS shows potential for enhancing the in vitro dissolution of NBH and demonstrates good stability.
5.Application and Characterization of Multiparticle System for Solubilization of Itraconazole
Yucheng CHEN ; Xin HU ; Mingzhi XU ; Lili HUANG ; Huaqing LIN
Chinese Journal of Modern Applied Pharmacy 2024;41(10):1357-1364
OBJECTIVE
To solve the problem of insolubility of itraconazole, improve its dissolution in vitro, and provide a reference for further industrial scale-up of the itraconazole multiparticle system.
METHODS
Itraconazole multiparticle system pellets were dissolved in an organic solvent and prepared in a fluidized bed by bottom spraying. Itraconazole and hydroxypropyl methylcellulose were sprayed onto the surface of the sucrose pellet core to form a uniform solid dispersion. The preparation parameters of the fluidized bed bottom spray coating were investigated by single factor method. The mass ratio of drug to carrier and core weight gain of the itraconazole multiparticle system were optimized by central composite design and response surface methodology with accumulative dissolution rate, application efficiency and adhesion rate as response values. Samples were prepared to verify the optimized prescription, the microscopic hierarchical structure of the itraconazole multiparticle system was observed by scanning electron microscope, and the solid dispersion in the itraconazole multiparticle system pellets was characterized by differential scanning calorimetry(DSC) and X-ray diffraction(XRD). The dissolution curves of itraconazole pellets and the physical mixture in 0.1 mol·L−1 HCl dissolution medium were compared to verify the solubilization effect.
RESULTS
Single factor method was used to determine the bottom spray coating parameters of the fluidized bed. The pumping speed was set as 3.0−5.0 mL·min−1, the atomization pressure was set as 1.5 bar, the inlet air volume was set as 110 m3·h−1, and the material temperature was set as 35 ℃. According to the central composite design and response surface methodology, the mass ratio of drug to carrier of the optimized prescription was 1∶1.5 and the core weight of the pill was 75%, and the response values reached the expected value. The result of scanning electron microscopy showed that the diameter of the itraconazole multiparticle system pellet was about 910 µm, the diameter of the sucrose pellet core was about 570 µm, the thickness of the drug loading layer was about 110 µm, and the thickness of encapsulation layer was about 11 µm. The results of DSC and XRD showed that itraconazole formed a uniform solid dispersion in the itraconazole multiparticle system pellets, which was amorphous. In the dissolution medium of 0.1 mol·L−1 HCl, the accumulative dissolution rate of the multiparticle system after 90 min was about 10 times that of the physical mixture, which showed that the solubilization effect was remarkable.
CONCLUSION
The dissolution of itraconazole in vitro can be significantly improved by processing itraconazole into pellets with multiparticle system and forming solid dispersion.
6.Results of neonatal screening for congenital hypothyroidism and hyperphenylalaninemia in Zhejiang province from 1999 to 2022.
Duo ZHOU ; Rulai YANG ; Xinwen HUANG ; Xiaolei HUANG ; Xin YANG ; Huaqing MAO ; Jianbin YANG ; Zhengyan ZHAO
Journal of Zhejiang University. Medical sciences 2023;52(6):683-692
OBJECTIVES:
To analyze the results of neonatal screening for congenital hypothyroidism (CH) and hyperphenylalaninemia (HPA) in Zhejiang province from 1999 to 2022.
METHODS:
A total of 11 922 318 newborns were screened from September 1999 and December 2022 in Zhejiang province. The blood thyroid stimulating hormone (TSH) levels were measured by a fluorescence method and blood phenylalanine (Phe) levels were measured by fluorescence method or tandem mass spectrometry. TSH≥9 μIU/mL was considered positive for CH, while Phe>120 μmol/L and/or Phe/Tyr ratio>2.0 were considered positive for HPA. The positive newborns in screening were recalled, and the gene variations were detected by high-throughput sequencing and MassARRAY tests.
RESULTS:
The overall neonatal screening rate during 1999-2022 was 89.41% (11 922 318/13 333 929) and the screening rate was increased from 6.46% in 1999 to 100.0% in 2022. A total of 8924 cases of CH were diagnosed among screened newborns with an incidence rate of 1/1336. A total of 563 cases of HPA were diagnosed, including 508 cases of classic phenylketonuria (cPKU) and 55 cases of tetrahydrobiopterin deficiency (BH4D), with an incidence rate of 1/21 176. Ninety-seven out of 8924 cases of CH underwent genetic analysis. Gene mutations were detected in 9 CH related genes, the highest frequency mutations were found in DUOX2 gene (69.0%) with c.3329G>A (p.R1110Q) (18.2%) and c.1588A>T (p.K530X) (17.3%) as the hotspot mutations. There were 81 PAH gene variants detected in a total of 250 cases of cPKU, and c728G>A (p.R243Q) (24.4%), c.721C>T (p.R241C) (15.0%) were the hotspot mutations. Meanwhile 7 novel variants in PAH gene were detected: c.107C>A (p.S36*), c.137G>T (p.G46V), c.148A>G(p.K50E), c.285C>T (p.I95I), c.843-10delTTCC, exon4-7del and c.1066-2A>G. There were 12 PTS gene variants detected in 36 cases of BH4D, and c.259C>T (p.P87S) (31.9%) was the hotspot mutation.
CONCLUSIONS
The incident of CH has increased from 1999 to 2022 in Zhejiang province, and it is higher than that of national and global levels; while the incidence of HPA is similar to the national average. DUOX2 gene variation is the most common in CH patients; c.728G>A (p.R243Q) is the hotspot mutation in cPKU patients, while c.259C>T (p.P87S) is the hotspot mutation in BH4D patients.
Humans
;
Infant, Newborn
;
Neonatal Screening
;
Dual Oxidases
;
Congenital Hypothyroidism/genetics*
;
Phenylketonurias/genetics*
;
Thyrotropin
7.Erratum: Author correction to 'TMEM16A inhibits angiotensin II-induced basilar artery smooth muscle cell migration in a WNK1-dependent manner' Acta Pharmaceutica Sinica B 11 (2021) 3994-4007.
Huaqing ZHENG ; Xiaolong LI ; Xin ZENG ; Chengcui HUANG ; Mingming MA ; Xiaofei LV ; Yajuan ZHANG ; Lu SUN ; Guanlei WANG ; Yanhua DU ; Yongyuan GUAN
Acta Pharmaceutica Sinica B 2023;13(9):3956-3960
[This corrects the article DOI: 10.1016/j.apsb.2021.04.013.].
8.Application Progress of Alginate Composite Hydrogels in Cancer Therapy
HUANG Lili ; HUANG Chengyu ; XU Mingzhi ; LIN Huaqing
Chinese Journal of Modern Applied Pharmacy 2023;40(16):2295-2305
Alginate composite hydrogel is one of the research hotspots of tumor drug delivery system materials at present. Alginate hydrogel has good biocompatibility and regeneration properties. However, the natural alginate saline gel may not achieve the expected results in the body environment due to the slow degradation and instability of the gel. Alginate has found extensive application in cancer therapy through its combination with other materials and the utilization of ionic cross-linking, covalent cross-linking, and free radical polymerization to form hydrogels. Based on the composite system of alginate brine gel, this paper summarizes the structure and properties of alginate hydrogel, with a focus on recent research into alginate composite hydrogel in common cancer treatments application, summarizes the current research focus and discuss the existing problems of alginate composite hydrogel, so as to provide reference for further expanding the research of alginate composite hydrogel in clinical cancer treatment.
9.Machine learning based on automated breast volume scanner radiomics for differential diagnosis of benign and malignant BI-RADS 4 lesions
Shijie WANG ; Huaqing LIU ; Jianxing ZHANG ; Cao LI ; Tao YANG ; Mingquan HUANG ; Mingxing LI
Chinese Journal of Ultrasonography 2023;32(2):136-143
Objective:To evaluate the performance of machine learning (ML) based on automated breast volume scanner (ABVS) radiomics in distinguishing benign and malignant BI-RADS 4 lesions.Methods:Between May to December 2020, patients with BI-RADS 4 lesions from the Affiliated Hospital of Southwest Medical University (Center 1) and Guangdong Provincial Hospital of Traditional Chinese Medicine (Center 2) were prospectively collected and divided into training cohort (Center 1) and external validation cohort (Center 2). The radiomics features of BI-RADS 4 lesions were extracted from the axial, sagittal and coronal ABVS images by MaZda software. In the training cohort, 7 feature selection methods and thirteen ML algorithms were combined in pairs to construct different ML models, and the 6 models with the best performance were verified in the external validation cohort to determine the final ML model. Finally, the diagnostic performance and confidence (5-point scale) of radiologists (R1, R2 and R3, with 3, 6 and 10 years of experience, respectively) with or without the model were evaluated.Results:①A total of 251 BI-RADS 4 lesions were enrolled, including 178 lesions (91 benign, 87 malignant) in the training cohort and 73 lesions (44 benign, 29 malignant) in the external validation cases. ②In the training cohort, the 6 ML models (DNN-RFE, AdaBoost-RFE, LR-RFE, LDA-RFE, Bagging-RFE and SVM-RFE) had the best diagnostic performance, and their AUCs were 0.972, 0.969, 0.968, 0.968, 0.967 and 0.962, respectively. ③In the external validation cohort, the DNN-RFE still had the best performance with the AUC, accuracy, sensitivity, specificity, PPV and NPV were 0.886, 0.836, 0.934, 0.776, 86.8% and 82.5%, respectively. ④Before model assistance, R1 had the worst diagnostic performance with the accuracy, sensitivity, specificity, PPV and NPV were 0.680, 0.750, 0.640, 57% and 81%, respectively. After model assistance, the diagnostic performance of R1 was significantly improved ( P=0.039), and its diagnostic sensitivity, specificity, accuracy, PPV and NPV improved to 0.730, 0.810, 0.930, 68% and 94%; while the improvement of R2 and R3 were not significantly ( P=0.811, 0.752). Meanwhile, the overall diagnostic confidence of the 3 radiologists increased from 2.8 to 3.3 ( P<0.001). Conclusions:The performance of ML based on ABVS radiomics in distinguishing between benign and malignant BI-RADS 4 lesions is good, which may improve the diagnostic performance of inexperienced radiologists and enhance diagnostic confidence.
10.Netrin-3 Suppresses Diabetic Neuropathic Pain by Gating the Intra-epidermal Sprouting of Sensory Axons.
Weiping PAN ; Xueyin HUANG ; Zikai YU ; Qiongqiong DING ; Liping XIA ; Jianfeng HUA ; Bokai GU ; Qisong XIONG ; Hualin YU ; Junbo WANG ; Zhenzhong XU ; Linghui ZENG ; Ge BAI ; Huaqing LIU
Neuroscience Bulletin 2023;39(5):745-758
Diabetic neuropathic pain (DNP) is the most common disabling complication of diabetes. Emerging evidence has linked the pathogenesis of DNP to the aberrant sprouting of sensory axons into the epidermal area; however, the underlying molecular events remain poorly understood. Here we found that an axon guidance molecule, Netrin-3 (Ntn-3), was expressed in the sensory neurons of mouse dorsal root ganglia (DRGs), and downregulation of Ntn-3 expression was highly correlated with the severity of DNP in a diabetic mouse model. Genetic ablation of Ntn-3 increased the intra-epidermal sprouting of sensory axons and worsened the DNP in diabetic mice. In contrast, the elevation of Ntn-3 levels in DRGs significantly inhibited the intra-epidermal axon sprouting and alleviated DNP in diabetic mice. In conclusion, our studies identified Ntn-3 as an important regulator of DNP pathogenesis by gating the aberrant sprouting of sensory axons, indicating that Ntn-3 is a potential druggable target for DNP treatment.
Mice
;
Animals
;
Diabetes Mellitus, Experimental/metabolism*
;
Axons/physiology*
;
Diabetic Neuropathies
;
Sensory Receptor Cells/metabolism*
;
Neuralgia/metabolism*


Result Analysis
Print
Save
E-mail