1.Peripheral White Blood Cell Dynamics as a Biomarker of Coronavirus Disease Severity
Joung Ha PARK ; Joung Ha PARK ; Hyemin CHUNG ; Hyemin CHUNG ; Min-Chul KIM ; Min-Chul KIM ; Seong-Ho CHOI ; Seong-Ho CHOI ; Jin-Won CHUNG ; Jin-Won CHUNG ; Hye Ryoun KIM ; Hye Ryoun KIM
Annals of Laboratory Medicine 2026;46(3):289-296
Background:
Despite widespread vaccination efforts against severe acute respiratory syndrome coronavirus 2, variants with increased transmissibility or immune evasion continue to emerge, posing a considerable challenge. Understanding the immunological factors associated with coronavirus disease (COVID-19) progression is essential for improving patient management and treatment strategies. We explored the dynamic changes in the peripheral white blood cell (WBC) profile, including T lymphocyte subsets, to assess their potential as predictors of disease severity and progression.
Methods:
Two hundred fifty-eight patients hospitalized for confirmed COVID-19 were classified into four sub-cohorts based on changes in disease severity over 7 days. WBC parameters, including absolute neutrophil, total lymphocyte, and T cell subset counts, and the neutrophil-to-lymphocyte ratio (NLR) were assessed at admission and after 7 days.
Results:
Patients with persistent mild-to-moderate illness exhibited a marked increase in the lymphocyte count and a decrease in the NLR over time. In contrast, patients with sustained severe-to-critical illness showed an increasing WBC count without a corresponding increase in the lymphocyte count, in addition to a marked elevation in the NLR. Patients whose condition improved from severe-to-critical to mild-to-moderate illness showed increased cluster of differentiation (CD)3+ and CD4+ T cell counts and an elevated CD4/CD8 ratio, whereas the NLR did not significantly change.
Conclusions
The early-phase dynamics of T cell subsets may serve as a useful biomarker of disease severity and recovery in patients with COVID-19. Monitoring these immunological changes may help support clinical decision-making and inform the timing of therapeutic interventions.
2.Association between Fibrovascular Translucency of Pterygium and Corneal Curvature and Aberrations after Adjustment for Horizontal Invasion Length
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2026;40(1):45-52
Purpose:
This study aims to determine whether the translucency-based clinical grade of pterygium shows independent relationships with anterior and posterior corneal curvature and anterior wavefront aberrations, with adjustment for horizontal invasion length (HIL) measured by anterior segment (AS) swept-source optical coherence tomography (SS-OCT).
Methods:
This study involved 53 eyes from 51 patients diagnosed with primary nasal pterygium. The clinical grade of the pterygium was evaluated using T grade based on the fibrovascular translucency. AS SS-OCT (Anterion, Heidelberg Engineering) provided HIL (in millimeters), thickness (in micrometers), anterior/posterior keratometry at the 3.0-mm ring, and anterior corneal wavefront metrics within a 6.0-mm zone. The device was also used to evaluate the magnitudes for the individual first-to fourth-order aberrations of the anterior corneal fields. Also, the fourth- to seventh-order root mean square (RMS), RMS lower-order aberration (LoA), and RMS higher-order aberration (HoA) values were collected. For statistical analysis, Spearman rank correlation test and Pearson correlation test were performed, along with partial correlation test adjusted for HIL.
Results:
The mean age of subjects was 59.3 ± 11.4 years, and 51.0% were female. T grade correlated positively with HIL. HIL showed strong associations with anterior simulated keratometry (Sim K) average, anterior Sim K steep, anterior Sim K flat, and anterior corneal astigmatism—but not with posterior corneal parameters. HIL also showed significant correlations with multiple anterior corneal wavefront parameters. After adjustment for HIL, T grade remained independently correlated with anterior Sim K flat, RMS LoA, and defocus; no significant relationships were observed with other Zernike terms or posterior metrics. Additionally, T grade was positively correlated with pterygium thickness.
Conclusions
T grade adds independent, complementary information (associations with flat keratometry, LoA RMS, and defocus) even after controlling for HIL. Incorporating T grade into preoperative assessment may improve estimation of optical burden and surgical prognosis.
3.Cross-Calibration of Bone Mineral Density and Body Composition between GE Lunar Prodigy and Hologic Horizon W Dual Energy X-Ray Absorptiometry Systems
Sujin KIM ; Guen Young LEE ; Jun-Il YOO ; Sang-Wook LEE ; Yong-Chan HA
Journal of Bone Metabolism 2026;33(1):84-93
Background:
Dual energy X-ray absorptiometry (DXA) measurements vary among instruments from different manufacturers. This study aimed to assess the correlation between bone mineral density (BMD) and body composition measured by the GE Lunar Prodigy and Hologic Horizon W DXA systems and to develop conversion equations.
Methods:
A total of 120 healthy volunteers (59 males, 61 females) aged 20 to 70 years were scanned on both DXA systems on the same day. BMD was measured at the lumbar spine (L1-L4) and bilateral femurs. Body composition parameters were measured for the whole body and regional sites. Bland-Altman analysis, Pearson correlation, and concordance correlation coefficient (CCC) were used to assess agreement. Linear regression was performed to derive conversion equations.
Results:
The Hologic system measured BMD values 14% to 20% lower at the lumbar spine and 8% to 17% lower at femoral sites compared to the GE Lunar system (all P<0.0001). Lean mass values were 4% to 10% lower on the Hologic system. Very strong correlations were observed for both BMD (r=0.944-0.980) and lean mass (r=0.963-0.984). Cross-calibration equations were developed for all measurement sites.
Conclusions
Despite significant systematic differences, there was very high correlation between the two DXA systems. The conversion equations can facilitate comparison of measurements between these systems in clinical practice and research.
4.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
5.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
6.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
7.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
8.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.
9.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
10.Anterior Segment Swept-Source Optical Coherence Tomography–based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2025;39(2):103-113
Purpose:
To analyze anterior, posterior, and total corneal refractive profiles and thickness using anterior segment (AS) sweptsource optical coherence tomography (SS-OCT) in Stevens-Johnson syndrome (SJS) or toxic epidermal necrolysis (TEN) patients.
Methods:
This retrospective study compared 23 eyes from 14 patients with SJS/TEN with 23 eyes from 14 age- and sexmatched controls. AS SS-OCT measured corneal refractive profiles and pachymetry. Parameters included anterior, posterior, and total corneal power values, posterior to anterior curvature ratio, maximal corneal power, and thickness profiles. The SJS/TEN group was subdivided based on corneal opacity presence (subgroup A) or absence (subgroup B).
Results:
The SJS/TEN group showed significantly higher corneal astigmatism and maximal corneal power values for both anterior and posterior curvatures. Steep total corneal power and total corneal astigmatism were higher in the SJS/TEN group. The thinnest corneal thickness was lower, and its distance from the corneal vertex was greater in the SJS/TEN group. Subgroup analysis revealed that these differences were primarily attributed to the presence of corneal opacity. Additionally, automated keratometry of the anterior corneal surface showed significantly higher values, including steep, flat, and average keratometry and corneal astigmatism, in the SJS/TEN group.
Conclusions
AS SS-OCT shows significant alterations in both anterior and posterior corneal curvatures in patients with SJS/TEN. These findings emphasize the importance of considering posterior corneal curvature changes in pre-cataract surgery assessments and contact lens prescriptions for patients with SJS/TEN.

Result Analysis
Print
Save
E-mail