1.Effects of ultra-high-frequency radiation exposure on mental arithmetic ability in workers
Jiachun JIN ; Shen XIE ; Guoyong XU ; Maosheng YAN ; Bikun YU
China Occupational Medicine 2026;53(1):65-68
Objective To investigate the impact of ultra-high-frequency radiation(UHFR) on the mental arithmetic ability in exposed workers. Methods A total of 79 workers engaged in high-frequency heat-sealing operations in a shoe factory were selected as the exposure group, and 121 workers from the same factory without such exposure were selected as the control group using the judgment sampling method. The intensity of UHFR from the high-frequency heat-sealing machines at the workplaces was measured on-site. Mental arithmetic performance of the participants of the two groups was assessed using the neurobehavioral ability index (NAI) from Neurobehavioral Evaluation System Chinese 3rd Generation. Results The NAI of the participants was lower in the exposure group than that in the control group [(1.17 ± 0.48) vs (1.39 ± 0.59), P<0.01], as was the NAI of the high-exposure subgroup within the exposure group [ (1.10 ± 0.43) vs (1.39 ± 0.59), P<0.01]. Females in the exposed group had lower NAI than that in the control group [(1.14 ± 0.49) vs (1.39 ± 0.60), P<0.01]. Multivariable logistic regression analysis indicated that exposure to high intensity electric field was a risk factor for abnormal NAI (odds ratio=2.04, 95% confidence interval was 1.00-4.19, P<0.05). Conclusion Occupational exposure to UHFR from high-frequency heat-sealing machines may negatively affect the mental arithmetic ability of workers. Occupational health protection measures, such as reducing UHFR exposure levels, enhancing individual protection, and strengthening occupational health surveillance, should be implemented.
2.Current status of occupational exposure to hand-transmitted vibration in Guangdong Province in 2025
Guoyong XU ; Bin XIAO ; Yuan PANG ; Mingzhen LAI ; Yongjian JIANG
Journal of Environmental and Occupational Medicine 2026;43(8):988-993
Background Although hand-arm vibration syndrome has traditionally been reported more frequently in colder northern regions, recent cases in Guangdong Province, a subtropical region in the south, exhibit a certain degree of clustering in terms of industry distribution and company size, and for a period of time, they account for a high proportion of the total number of cases reported nationwide. Objective To describe the occupational exposure profile of hand-transmitted vibration (HTV) in Guangdong Province in 2025 and to compare exposure levels across industries, enterprise sizes, and occupational categories. Methods Data were sourced from the Guangdong Provincial Occupational Health Quality Control Platform, to which occupational health technical service institutions across Guangdong Province submitted relevant reports in 2025. The dataset included employers with documented HTV hazards, measurement results, and the number of exposed workers. Exposure levels were categorized into four grades according to the 4-h energy-equivalent frequency-weighted vibration acceleration: Grade I (<1 m·s−2), Grade II (1-2.5 m·s−2), Grade III (>2.5-5 m·s−2), and Grade IV (>5 m·s−2). Results A total of 12468 employers with identifiable HTV exposure were identified through the platform in 2025, of which 11710 (93.92%) were in the manufacturing sector. By enterprise scale, 274 (2.20%) were large, 934 (7.49%) were medium-sized, 8 749 (70.17%) were small, and 2511 (20.14%) were micro-sized enterprises, with small enterprises accounting for the largest proportion. Among 22298 job posts with identified HTV exposure, grinding, assembly, polishing, burnishing, and welding were the most common tasks. The M (P25, P75) 4-h energy-equivalent frequency-weighted acceleration [a(4)] was 2.1 (1.5, 2.7) m·s−2, with values ranging from 0.1 to 16.2 m·s−2. Exposure levels were distributed as follows: Grade I, 2835 posts (12.71%); Grade II, 12761 posts, (57.23%); Grade III, 6690 posts, (30.00%); and Grade IV, 12 posts (0.05%), with Grade Ⅱ posts accounting for the largest proportion. Within the manufacturing sector, 21013 exposed job posts were identified, accounting for 94.24% of all exposed posts. Twelve job posts exceeded the occupational exposure limit, of which nine were polishing positions. A total of 115955 workers were exposed to HTV, primarily in manufacturing (110879; 95.62%). Among the exposed workers, 21237, 23454, 65047, and 6217 were employed in large, medium, small, and micro-sized enterprises, respectively. Grinding, assembly, polishing, deburring, and welding were the five most common occupational categories among the exposed workers. The distribution of worker by exposure grade was similar to that of exposed posts: Grade I, 11921 workers (10.28%); Grade II, 65463 workers (56.46%); Grade III, 38447 workers (33.16%); and Grade IV, 124 workers (0.11%). Conclusion In Guangdong Province, HTV exposure is mainly concentrated in the manufacturing sector, particularly in metal product manufacturing, and commonly involves tasks such as grinding, assembly, and polishing. Both exposed enterprises and exposed workers are predominantly concentrated in small enterprises. Grade II exposure accounts for the largest proportion of both exposed job posts and exposed workers, and some workers are at a risk of developing hand-arm vibration syndrome. These findings suggest that targeted occupational management and comprehensive control measures should be strengthened to reduce HTV exposure and prevent hand-arm vibration syndrome.
3.Analysis of distortion product otoacoustic emissions results of noise-exposed workers at a metal shipbuilding enterprise
Jieting ZHOU ; Jianyu GUO ; Hairu YANG ; Linyan SHU ; Zhixing FAN ; Jia TANG ; Xinqiang NIE ; Guoyong XU ; Hansheng LIN ; Bin XIAO
China Occupational Medicine 2025;52(1):99-105
Objective To evaluate the role of distortion product otoacoustic emissions (DPOAE) testing in evaluating early hearing loss among noise-exposed workers. Methods A total of 174 noise-exposed workers in a metal shipbuilding enterprise were selected as the research subjects by the convenience sampling method. Pure tone audiometry (PTA), DPOAE and the level of noise exposure were conducted on the workers. The rank correlation analysis was used to analyze the correlation between DPOAE amplitude and PTA threshold. The multilevel model was used to analyze the effects of gender, age, noise exposure intensity, cumulative noise exposure (CNE), hearing loss classification and PTA threshold on DPOAE results. Results At the frequencies of 0.50, 1.00, 2.00, 3.00, 4.00, 6.00 and 8.00 kHz, the DPOAE amplitude was negatively correlated with the PTA threshold (rank correlation coefficients were -0.12, -0.48, -0.47, -0.18, -0.23, -0.44, -0.19, respectively, all P<0.01). At the most frequencies, DPOAE amplitude was negatively correlated with age and CNE (all P<0.05). The results of multilevel model analysis showed that there were significant differences in DPOAE amplitudes at certain frequencies across gender, age, noise intensity, CNE, and hearing loss classification (all P<0.05). Significant differences in DPOAE responses were found among different CNE and hearing loss groups (all P<0.01). Conclusion DPOAE testing can objectively reflect the hearing status of noise-exposed workers and could be considered for inclusion in routine hearing monitoring to facilitate early detection of noise-induced hearing loss.
4.Design and Reliability Research of Spherical Radiotherapy Accelerator Motion System.
Shuming XU ; Yongxin CHE ; Haipeng LIANG ; Guoyong ZHAO ; Yanjie LI
Chinese Journal of Medical Instrumentation 2025;49(1):48-54
At present, the C-arm structure accelerators commonly used in radiotherapy equipment are complex in operation and have potential safety hazards when realizing non-coplanar treatment. By combining with medical robotic arm technology, a spherical radiotherapy accelerator motion system is designed. The beam module is clamped by the medical robotic arm structure to achieve three-dimensional multi-angle irradiation treatment within the non-coplanar angle range. Firstly, the rotating mechanism, beam module, and MLC module of the spherical radiotherapy equipment are designed. Then, the double-plane counterweight method is used to calculate the dynamic balance of the equipment, ensuring that the beam center point does not rotate during the treatment process. Finally, the strength check and reliability analysis of the transmission component gear are conducted. The results show that the designed spherical radiotherapy accelerator motion system can meet the requirements of stable, accurate, and fast precision radiotherapy, which is conducive to improving the treatment efficiency.
Particle Accelerators/instrumentation*
;
Equipment Design
;
Reproducibility of Results
;
Radiotherapy/instrumentation*
5.Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures (version 2025)
Yong YANG ; Xiaoguang ZHOU ; Qixin CHEN ; Jian CHEN ; Jian DONG ; Liangjie DU ; Shunwu FAN ; Jin FAN ; Zhong FANG ; Haoyu FENG ; Shiqing FENG ; Haishan GUAN ; Aiguo GAO ; Yanzheng GAO ; Yong HAI ; Da HE ; Dengwei HE ; Haiyi HE ; Dianming JIANG ; Xuewen KANG ; Bin LIN ; Baoge LIU ; Changqing LI ; Fang LI ; Li LI ; Fangcai LI ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Xinyu LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Fei LUO ; Yuhai MA ; Keya MAO ; Xuexiao MA ; Bin MENG ; Xu NING ; Limin RONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Dasheng TIAN ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Qingde WANG ; Qinghe WANG ; Lan WEI ; Jigong WU ; Baoshan XU ; Youjia XU ; Guoyong YIN ; Jinglong YAN ; Feng YAN ; Cao YANG ; Huilin YANG ; Qiang YANG ; Bin ZHAO ; Jie ZHAO ; Yue ZHU ; Jianguo ZHANG ; Wenzhi ZHANG ; Zhongmin ZHANG ; Zhaomin ZHENG ; Yan ZENG ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(7):613-626
Vertebral refracture following percutaneous vertebral augmentation (PVA) is commonly seen in elderly patients with osteoporotic thoracolumbar compression fractures (OTLCF). It can lead to recurrent pain, loss of vertebral height, progression of kyphosis, and even neurological dysfunction, significantly impairing patients′ quality of life. Current diagnosis and treatment face multiple challenges, including high misdiagnosis rate, difficulty in choosing between surgical and non-surgical treatment options, lack of standardized surgical protocols, interference from intralesional bone cement during procedures, inadequate stability of internal fixation in osteoporotic bone, and suboptimal compliance of anti-osteoporotic therapy. Establishing a standardized diagnostic and therapeutic framework is urgently needed. To standardize the management process and improve outcomes for vertebral refractures after PVA in elderly OTLCF patients, Spinal Trauma Group of the Orthopedic Branch of Chinese Medical Doctor Association organized experts in the field to develop Guideline for the diagnosis and treatment of vertebral refracture after percutaneous vertebral augmentation in elderly patients with osteoporotic thoracolumbar compression fractures ( version 2025), based on current literature and clinical experience, and adhering to principles of scientific rigor and clinical applicability. A total of 11 recommendations were proposed, encompassing diagnosis, treatment, and rehabilitation of vertebral refracture after PVA in elderly patients with OTLCF, aiming to provide a foundation for a standardized management.
6.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
7.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
8.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.
9.Distribution of pupil diameter and its association with myopia in school age children
Chinese Journal of School Health 2025;46(8):1194-1197
Objective:
To investigate the distribution of pupil diameter and its association with myopia in school age children, providing ideas into the mechanisms of the role of pupil diameter in the onset and development of myopia.
Methods:
Adopting a combination of stratified cluster random sampling and convenience sampling method, 3 839 children from six schools in Shandong Province were included in September 2021. Pupil diameters distribution was analyzed by age, sex, and myopic status. Pearson correlation analysis was used to assess the relationship between pupil diameter and cycloplegic spherical equivalent (SE), as well as axial length (AL) and other variables. Propensity score matching (PSM) was applied to match myopic and non myopic children at a 1∶1 ratio based on age and sex. A generalized linear model (GLM) was constructed with pupil diameter as the dependent variable to identify independent factors influencing pupil size and its association with myopia.
Results:
The mean pupil diameter of school age children was (5.77±0.80)mm. Pupil diameter exhibited a significant increasing trend with age ( F =49.34, P trend < 0.01). Myopic children had a significantly larger mean pupil diameter [(6.10±0.73)mm] compared to non myopic children [(5.62±0.79)mm] with a statistically significant difference( t=18.10, P <0.01). Multivariable GLM analysis, adjusted for age, amplitude of accommodation, and uncorrected visual acuity, revealed a negative correlation between pupil diameter and cycloplegic SE (before PSM: β =-0.089, after PSM: β =-0.063, both P <0.01).
Conclusions
Myopic school age children exhibite larger pupil diameters than their non myopic counterparts. Pupil diameter may serve as a potential indicator for monitoring myopia development in school age children.
10.Analyzing the influencing factors of work-related musculoskeletal disorders among construction workers
Maosheng YAN ; Xiongda HE ; Chunshuo CHEN ; Ning JIA ; Junle WU ; Guoyong XU ; Hua YAN ; Zhipeng HE ; Yongjian JIANG ; Jianyu GUO ; Bin XIAO
China Occupational Medicine 2025;52(5):503-510
Objective To investigate the prevalence and risk factors of work-related musculoskeletal disorders (WMSDs) among construction workers. Methods A total of 5 783 workers were selected as participants from 12 construction companies in Guangdong Province, Guangxi Zhuang Autonomous Region and Zhejiang Province using a convenient sampling method. The revised Musculoskeletal Disorders Questionnaire was used to investigate the prevalence and influencing factors of WMSDs. Results The prevalence of WMSDs was 27.4% among the construction workers. The prevalence of WMSDs in shoulder, neck, waist/lower back and hand/wrist was 10.6%, 9.5%, 9.5% and 9.4% respectively, which was higher than that in other body parts. Bianry logistic regression analysis showed that the risk of WMSDs in construction workers with junior high school education and below was higher than that of high school/ college and above (P<0.05). The risk of WMSDs was higher in drinkers than that in non-drinkers (P<0.01). The worse the health status of construction workers, the higher the risk of WMSDs (P<0.01). The risk of WMSDs in those who exercised once or twice a month was lower than that in those who did not exercise (P<0.05). The risk of WMSDs was higher in construction workers with longer working hours in uncomfortable postures and greater back bending amplitude at work (all P<0.01). The risk of WMSDs in construction workers with hands holding above the shoulder was higher than that with hands below the shoulder (P<0.05). Construction workers who repeated the same work daily, involved in high-temperature work, often worked overtime, had insufficient rest time, and had a shortage of department personnel had a relatively high risk of WMSDs (all P<0.01). Conclusion The prevalence of WMSDs among the construction workers was relatively high, and the most common WMSDs occurred in shoulder, neck, waist/lower back and hand/wrist. Individual characteristic, work type, work posture and work organization are the influencing factors of WMSDs. Comprehensive measures, especially ergonomic measures based on personal and occupational characteristics should be taken to reduce the risk of WMSDs among construction workers.


Result Analysis
Print
Save
E-mail