1.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
2.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
3.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
4.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
5.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
6.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.
7.Quality Evaluation of Black Panacis Quinquefolii Radix Based on Neuroprotective Spectrum-effect Relationship
Yuting YANG ; Shuyun LIANG ; Shanshan LI ; Yulong YANG ; Ziqi YANG ; Guangzhi CAI ; Liru ZHAO ; Jiyu GONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(18):149-156
ObjectiveTo clarify the neuroprotective effect of black Panacis Quinquefolii Radix(PQR) and explore its active ingredients, with the aim of establishing an activity-oriented quality evaluation method. MethodsTransgenic Tg(HuC∶EGFP) zebrafish was used to establish a neuronal injury model by aluminum chloride immersion. Different doses(10, 20 mg·L-1) of PQR and black PQR ethanol extracts were administered. The neuroprotective effects of PQR and black PQR were compared by analyzing the fluorescent area and intensity of zebrafish neurons. Based on ultra-performance liquid chromatography(UPLC), a fingerprint profile of black PQR was established, followed by principal component analysis(PCA) and orthogonal partial least squares-discriminant analysis(OPLS-DA). Differential components were screened using the criteria of variable importance in the projection(VIP) value>1 and P<0.05. The neuroprotective activity of 14 batches of black PQR was assessed, and Spearman correlation analysis was used to identify saponins related to neuroprotective activity, which were then validated. Based on the above results, active marker components were determined, and an UPLC method was established for their quantitation with clear content limits. ResultsPharmacological efficacy results showed that both PQR and black PQR at different doses could significantly improved neuronal damage in zebrafish. At a dose of 20 mg·L-1, black PQR demonstrated superior efficacy(P<0.05). The fingerprint similarities of 14 batches of black PQR were>0.94, with 26 common peaks identified. Through comparison with the reference standards, 8 components were confirmed, including peak 1(ginsenoside Rg1), peak 2(ginsenoside Re), peak 5(ginsenoside Rb1), peak 9(ginsenoside Rd), peak 16[ginsenoside 20(S)-Rg3], peak 17[ginsenoside 20(R)-Rg3], peak 18(ginsenoside Rk1), and peak 19(ginsenoside Rg5). The results of PCA and OPLS-DA indicated that there were differences in saponins among black PQR samples from different origins, and 12 differential components were screened. All 14 batches of black PQR exhibited good protective effects on zebrafish neurons, with Shaanxi-produced black PQR showing superior protective effects compared to the other three production regions. Spearman correlation analysis revealed that a total of 11 components, including ginsenosides 20(S)-Rg3, 20(R)-Rg3, Rk1 and Rg5, showed a significant positive correlation with the neuroprotective effect in zebrafish(P<0.05). The activity validation results indicated that ginsenosides 20(S)-Rg3, 20(R)-Rg3, Rk1 and Rg5 were the primary components responsible for the neuroprotective effects of black PQR. Quantitative analysis showed that the content of ginsenoside 20(S)-Rg3 in 14 batches of black PQR ranged from 0.17% to 0.52%, and the repair rate of neuronal damage ranged from 42.77% to 97.83%. ConclusionBased on the fingerprint and neuronal protective activity, the spectrum-effect related quality control model of black PQR was established, with ginsenoside 20(S)-Rg3 as the quality control index, and the neuronal damage repair rate≥60% as the evaluation standard, the minimum limit of ginsenoside 20(S)-Rg3 in black PQR should be≥0.20%.
8.Clinical efficacy of transcatheter edge-to-edge repair in patients with non-central degenerative mitral regurgitation
Peijian WEI ; Junke CHANG ; Jianrui MA ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shiguo LI ; Fujian DUAN ; Wenbin OUYANG ; Shouzheng WANG ; Fang FANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(4):373-381
Objective:To evaluate the clinical efficacy of mitral valve transcatheter edge-to-edge repair (TEER) in patients with non-central degenerative mitral regurgitation (DMR).Methods:This retrospective study included patients with non-central DMR who underwent TEER at Fuwai Hospital between January 2021 and February 2024. Patients were categorized into two groups: the commissure-involved group and the non-commissure group, based on whether the mitral valve commissures were involved. Clinical data, surgical outcomes, and echocardiographic findings at 3 months postoperatively were collected and compared, and patients were followed up. The primary endpoint was the procedural success rate at discharge.Results:A total of 59 patients were included, aged (68.6±9.3) years, including 23 females (39%). In the overall study population, 78% (46/59) of patients had severe mitral regurgitation. Forty-two cases were in the non-commissure group, and 17 cases were in the commissure-involved group. Patients in the non-commissure group mainly had lesions in the A1/P1 region, while patients in the commissure-involved group mainly had lesions in the A3/P3 region. There was no significant difference in the procedural success rate at discharge (93% vs. 88%, P=0.95) and the incidence of postoperative complications (5% vs. 6%, P=1.00) between the two groups. Two patients in the commissure-involved group experienced single leaflet device attachment, with one of them requiring conversion to surgical mitral valve surgery; In the non-commissure group, two patients experienced single-valve clamping, and one of them was converted to surgical mitral valve surgery. The follow-up time of the entire cohort was (15.5±10.3) months. In the non-commissure group, 2 patients died and 2 were readmitted. While in the commissure-involved group, no patients died and only 1 patient was readmitted. Conclusion:TEER is an effective treatment for patients with non-central DMR involving the commissures, without increasing the incidence of postoperative complications.
9.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
10.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.

Result Analysis
Print
Save
E-mail