1.Diagnostic value of 18F-FDG and 18F-FMZ PET/CT in the localization of focal cortical dysplasia
Guanglei LI ; Juanjuan HE ; Weiqi BAO ; Shize JIANG ; Qi HUANG ; Shuhua REN ; Fang XIE ; Jie HU ; Yihui GUAN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(10):588-591
Objective:To compare the localization accuracy of interictal 18F-FDG and 18F-flumazenil (FMZ) PET/CT imaging for focal cortical dysplasia (FCD). Methods:A retrospective analysis was conducted on 22 patients (12 males, 10 females; age 8-36 years) with pathologically confirmed FCD who underwent surgical resection at Huashan Hospital, Fudan University from July 2021 to June 2023. All patients underwent 18F-FDG and 18F-FMZ PET/CT scans before surgery. Surgical pathological diagnosis was used as the gold standard. Visual scoring was used to analyze the images. The accuracy of the two imaging methods in the localization of FCD was compared, and subgroup analysis (FCD Ⅱa, FCD Ⅱb) of different pathological type was further performed. Paired- t test, χ2 test or Fisher′s exact test was used to analyze the data. Results:The visual score of 18F-FMZ PET/CT was higher than that of 18F-FDG (3.00±0.82 vs 2.27±0.92; t=4.17, P=0.020). The accuracy of interictal 18F-FMZ PET/CT was 77.27%(17/22), which was higher than that of 18F-FDG PET/CT (36.36%, 8/22; χ2=7.50, P=0.006). Subgroup analysis showed that within the cohort of patients diagnosed with FCD Ⅱa ( n=18), 18F-FMZ PET/CT outperformed 18F-FDG in terms of accuracy for localization (15/18 vs 6/18; P=0.006). Conclusion:Compared to 18F-FDG, 18F-FMZ PET/CT demonstrates clearer and more accurate identification of lesion borders, and exhibits higher precision, which provides valuable guidance for preoperative localization.
2.Construction and application evaluation of a multi-dimensional surgical equipment management and control platform based on artificial intelligence and Internet of Things
Guanglei GAN ; Juan HUANG ; Naijuan XU ; Meiling KONG ; Xiangdong GU
China Medical Equipment 2024;21(1):130-134,146
Objective:To construct a multi-dimensional surgical equipment management and control platform based on artificial intelligence and Internet of Things(AIoT)to assist with the refinement and intelligent management medical equipment in hospital operating rooms.Methods:A multi-dimensional surgical equipment control platform based on AIoT was established by integrating the Internet of Things(IoT),big data analysis,indoor positioning technology,artificial intelligence(AI)technology and other technologies to collect real-time process data of surgical equipment such as endoscopy and electrosurgical,and to open up the relationships among information systems relating to surgical equipment,such as hospital information system(HIS),laboratory information system(LIS),radiology information system(RIS)and operation anesthesia management system(OAMS),so as to provide technical support for efficiency analysis,benefit analysis and assets management of surgical equipment.The platform was composed of 3 layers:data extraction layer,data engine layer and AI data analysis layer,including 4 functional modules:automatic data acquisition,deep data fusion,data mining and analysis and data visualization.Results:This platform was launched in Shanghai Municipal Hospital of Traditional Chinese Medicine in June 2022,and had realized achieving intelligent daily management such as indoor positioning of operating room equipment,one click inventory.A set of performance analysis method based on IoT and integrated with information systems was established to automatically count the utilization efficiency and cost-effectiveness of key surgical equipment to realize intelligent service,intelligent management,and digital operation.Conclusion:The construction and application of this platform improved the efficiency of medical equipment in operating rooms,reduced the cost and increased the efficiency,assisted in the refinement and intelligent management of hospital surgical equipment,and provided data support for scientific decision-making of hospital managers.
3.Association of IL-10 and TNF-α gene polymorphisms with hepatic echinococcus granulosus infection and necrosis
Guanglei TIAN ; Lunhong CHEN ; Bofeng YU ; Xiaorong HUANG ; Jinguo WANG ; Kalifu BAHETI ; Yuan MENG ; Wei SONG ; Zhigang MA ; Xiong CHEN
Journal of Chinese Physician 2022;24(10):1504-1508
Objective:To investigate the association between hepatic echinococcus granulosus infection and necrosis with gene polymorphism of interleukin-10 (IL-10) and tumor necrosis factor-α (TNF-α), and to identify the related factors at the gene level.Methods:A total of 106 patients with hepatic echinococcosis who underwent surgical treatment in the department of hepatobiliary surgery, People′s Hospital of Xinjiang Uygur Autonomous Region from January 2018 to December 2020 were selected. Patients with necrosis caused by hepatic echinococcus granulosus infection were selected as the observation group, and patients without necrosis caused by hepatic echinococcus granulosus infection were selected as the control group, with 53 cases in each group. The serum levels of IL-10 and TNF-α were detected by enzyme-linked immunosorbent assay (ELISA). The polymorphisms of IL-10 (-592, -1082) and TNF-α (rsl800630) were detected by polymerase chain reaction (PCR). The levels of IL-10 and TNF-α and their gene polymorphisms were analyzed.Results:The levels of serum IL-10 and TNF-α in the observation group were significantly higher than those in the control group (all P<0.05); There was significant difference in genotype and allele frequency of IL-10 (-592, -1082) and TNF-α (rsl800630) (all P<0.05). The serum IL-10 level of CC genotype patients with IL-10 gene -592C/A locus in the observation group was higher than that of CA+ AA genotype patients, with statistically significant difference ( P<0.05). The serum IL-10 level in patients with TT genotype at -1082T>A of IL-10 gene in the observation group was higher than that in patients with TA+ AA genotype, with statistically significant difference ( P<0.05). The serum TNF-α level in patients with CC genotype at rsl800630C/A locus of TNF-α gene in the observation group was higher than that in patients with CA+ AA genotype, with statistically significant difference ( P<0.05). Conclusions:The changes of IL-10 (-592, -1082) and TNF-α (rsl800630) gene polymorphisms may be associated with hepatic echinococcus granulosus infection and necrosis.
4.Clinical analysis of a child with cardio-facio-cutaneous syndrome due to a de novo variant of MAP2K1 gene.
Hongyao CAO ; Guanglei TONG ; Ru HUANG ; Taocheng ZHOU ; Weiwei ZHANG
Chinese Journal of Medical Genetics 2022;39(10):1129-1134
OBJECTIVE:
To explore the genotype-phenotype correlation of a patient with cardio-facio-cutaneous syndrome (CFCS) due to variant of the MAP2K1 gene.
METHODS:
DNA was extracted from peripheral blood samples of the infant and his parents and subjected to whole exome sequencing. Candidate variant was verified by Sanger sequencing.
RESULTS:
The patient had typical CFCS facies and developmental delay, and was found to harbor a de novo heterozygous c.389A>G (p.Tyr130Cys) missense variant in exon 3 of the MAP2K1 gene. Based on the American college of Medical Genetics and Genomics guidelines, this variant was classified as likely pathogenic.
CONCLUSION
This patient has differed from previously reported cases by having no cardiac anomaly or seizures but typical facial features and skin abnormalities accompanied by growth retardation, intellectual impairment, and urinary malformation. It has therefore enriched the phenotypic spectrum of CFCS due to variants of the MAP2K1 gene.
Ectodermal Dysplasia/genetics*
;
Facies
;
Failure to Thrive/genetics*
;
Heart Defects, Congenital
;
Humans
;
MAP Kinase Kinase 1/genetics*
;
Mutation
5.Research progress of three-dimensional printed guides in unicompartmental knee arthroplasty
Xufeng JIAO ; Shuai AN ; Guanglei CAO ; Zheng LI ; Jiang HUANG ; Mingli FENG
Chinese Journal of Surgery 2021;59(6):550-554
Unicompartmental knee arthroplasty(UKA) is an important surgical technique for the treatment of end-stage knee osteoarthritis, which has high requirement for the position and angle of the prosthesis. The application of three-dimensional(3D) printed in UKA reflects several characteristics such as accuracy,efficiency and safety,but the current research results show that there is still lack of consistency in the design of 3D printed guides and the standard of prosthetic position parameters. This article reviews the history, manufacturing requirements and process of 3D printed guides during UKA surgery, as well as the results of current clinical research. Whether 3D printed guides can safely and effectively improve the placement accuracy of inexperienced doctors during UKA surgery,and whether the long-term results are worthy of clinical promotion need further verification.
6.Research progress of three-dimensional printed guides in unicompartmental knee arthroplasty
Xufeng JIAO ; Shuai AN ; Guanglei CAO ; Zheng LI ; Jiang HUANG ; Mingli FENG
Chinese Journal of Surgery 2021;59(6):550-554
Unicompartmental knee arthroplasty(UKA) is an important surgical technique for the treatment of end-stage knee osteoarthritis, which has high requirement for the position and angle of the prosthesis. The application of three-dimensional(3D) printed in UKA reflects several characteristics such as accuracy,efficiency and safety,but the current research results show that there is still lack of consistency in the design of 3D printed guides and the standard of prosthetic position parameters. This article reviews the history, manufacturing requirements and process of 3D printed guides during UKA surgery, as well as the results of current clinical research. Whether 3D printed guides can safely and effectively improve the placement accuracy of inexperienced doctors during UKA surgery,and whether the long-term results are worthy of clinical promotion need further verification.
7. The influence of spinal sagittal balance on acetabular component orientation and its clinical relevance
Kangming CHEN ; Gangyong HUANG ; Guanglei ZHAO ; Changquan LIU ; Jun XIA
Chinese Journal of Orthopaedics 2020;40(2):103-109
Total hip arthroplasty (THA) is a well developed technique to which the spatial orientation of acetabular component is crucial. Since the idea of "safe zone" being proposed, such idea has long been obeyed by hip surgeons but has also been challenged in recent years. This is because post-operative instability could happen even if acetabular components are placed within "safe zone" . The latest researches have demonstrated that sagittal spinal balance and spino-pelvic mobility can affect the spatial orientation of acetabular components. Factors including spinal degenerative changes, long lumbosacral changes and spinal ankyloses can lead to sagittal spinal imbalance and/or influence spino-pelvic mobility, which subsequently affect pelvic retroversion. Proper pelvic retroversion is a way to compensate for sagittal spinal imbalance and is beneficial to post-operative stability. It is necessary for hip surgeons to rethink "safe zone" before performing THA and understand spinal balance as well as spinopelvic mobility. The goal is to reduce the rate of dislocation. This review started by introducing the related spinopelvic parameters frequently seen in papers published recently and the definitions of acetabular cup orientations. After the spinal sagittal balance and its compensatory mechanisms session, discussed its clinical relevance, as well as the significance of spinal mobility, in spinopelvic motion under three different postures.
8. Advance of head taper corrosion after metal on polyethylene total hip arthroplasty
Shuai AN ; Zheng LI ; Guanglei CAO ; Mingli FENG ; Jiang HUANG ; Huiliang SHEN
Chinese Journal of Orthopaedics 2019;39(10):630-636
Total hip arthroplasty is currently an important surgical method for the treatment of hip diseases. The modular design of the head and neck taper facilitates the adjustment of limb length and femoral offset during surgery, however, complications such as wear, corrosion and looseness of the modular interface are also inevitable old problems. In recent years, with the changes in the design of prostheses, the trend that patients becomes younger and active, and the development of minimally invasive surgery, taper corrosion has again become a problem that needs to be solved and cannot be ignored, which is causing the attention of joint surgeons. There have been many studies on the complications associated with metal-on-metal prosthesis modular interfaces, such as increased metal ion level, taper corrosion and adverse local tissue reactions, while there are few studies on the complications of metal-on-polyethylene total hip arthroplasty, and metal-on-polyethylene prosthesis has similar problems such as increased local metal ion level and adverse tissue reactions caused by taper corrosion, which may also lead to complications such as prosthesis loosening, dislocation and fracture. Currently there are few reports about head and neck taper corrosion of metal-on-polyethylene prosthesis in China and there are still controversies about its manifestation and mechanism. In this paper, we summarized the above problems through literature reviewto expound the concept, research history, assessment methods, and incidence of metal-on-polyethylene prosthesistaper corrosion and the effect of material composition, diameter of the metal head, neck length, femoral offset, geometry of the taper, surgical factors, in vivo time, and patient factors on taper corrosion are analyzed. In summary, there are still many problems in the researches about the specific forming mechanism that have not been solved, thus it is very important for the prevention of taper corrosion: choosing the same material or ceramic material, avoiding overlarge diameter of the femoral head and femoral offset, avoiding too small taper degree, paying attention to the strength of tapping and cleaning of the taper are the current viable options.
10.The effects of N2 O inhalation sedation in the management of dental fear for dental treatments of children
Hao CHEN ; Hong LUO ; Guanglei HUANG ; Ke ZHAO
Journal of Practical Stomatology 2014;(2):251-253
Objective:To study the effects of nitrous oxide(N2 O)sedation in the management of dental fear(DF)for dental treat-ments of children.Methods:66 cases of pediatric patients(aged 6 to 14 years)were given N2 O sedation for dental treatments.The heart rate(HR)and oxygen saturation(SpO2 )were measured before and after N2 O inhalation.N2 O effective concentration was eval-uated by Ramsay sedation score and Houpt behavior score.Results:The effective concentration of N2 O sedation was 25% -70%(49.6% ±12.1%),the maximum endurance concentration 35%-70% (56.4% ±10.1%).The Ramsy scores of N2 O sedation was (2.3 ±0.6).After N2 O inhalation,all patients could receive verbal demand during the treatments.The HR decreased(P <0. 05)and the Houpt behavior score increased(P <0.01).Before and after N2 O inhalation SpO2 had no significant difference(P >0.05).Conclusion:N2 O inhalation at 25% -70% is safe and effective in the management of DF for dental treatments of children.

Result Analysis
Print
Save
E-mail