1.Current Status and Future Development of Boron Neutron Capture Therapy
Cancer Research on Prevention and Treatment 2026;53(4):243-250
Boron neutron capture therapy (BNCT) is a precision radiotherapy technology for tumors. On the international stage, Japan stands out as a representative country where BNCT has progressed into a mature clinical phase. Although China started relatively late, it has achieved rapid advancements through independent research and development in accelerator and neutron source equipment, domestically produced boron drugs, and clinically validated therapeutic efficacy. In several key indicators, China has now reached internationally advanced levels. Looking ahead, efforts should be prioritized toward the development of third-generation boron-based drugs, the standardization of treatment protocols, and cost reduction to enhance treatment accessibility, ultimately aiming to build a competitive BNCT clinical application and technological innovation system.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
4.Exploring urban versus rural disparities in atrial fibrillation: prevalence and management trends among elderly Chinese in a screening study.
Wei ZHANG ; Yi CHEN ; Lei-Xiao HU ; Jia-Hui XIA ; Xiao-Fei YE ; Wen-Yuan-Yue WANG ; Xin-Yu WANG ; Quan-Yong XIANG ; Qin TAN ; Xiao-Long WANG ; Xiao-Min YANG ; De-Chao ZHAO ; Xin CHEN ; Yan LI ; Ji-Guang WANG ; FOR THE IMPRESSION INVESTIGATORS AND COORDINATORS
Journal of Geriatric Cardiology 2025;22(2):246-254
BACKGROUND:
Atrial fibrillation (AF) is a common cardiac arrhythmia in the elderly. This study aimed to evaluate urban-rural disparities in its prevalence and management in elderly Chinese.
METHODS:
Consecutive participants aged ≥ 65 years attending outpatient clinics were enrolled for AF screening using handheld single-lead electrocardiogram (ECG) from April 2017 to December 2022. Each ECG rhythm strip was reviewed from the research team. AF or uninterpretable single-lead ECGs were referred for 12-lead ECG. Primary study outcome comparison was between rural and urban areas for the prevalence of AF. The Student's t-test was used to compare mean values of clinical characteristics between rural and urban participants, while the Pearson's chi-square test was used to compare between-group proportions. Multivariate stepwise logistic regression analysis was performed to estimate the association between AF and various patient characteristics.
RESULTS:
The 29,166 study participants included 13,253 men (45.4%) and had a mean age of 72.2 years. The 7073 rural participants differed significantly (P ≤ 0.02) from the 22,093 urban participants in several major characteristics, such as older age, greater body mass index, and so on. The overall prevalence of AF was 4.6% (n = 1347). AF was more prevalent in 7073 rural participants than 22,093 urban participants (5.6% vs. 4.3%, P < 0.01), before and after adjustment for age, body mass index, blood pressure, pulse rate, cigarette smoking, alcohol consumption and prior medical history. Multivariate logistic regression analysis identified overweight/obesity (OR = 1.35, 95% CI: 1.17-1.54) in urban areas and cigarette smoking (OR = 1.62, 95% CI: 1.20-2.17) and alcohol consumption (OR = 1.42, 95% CI: 1.04-1.93) in rural areas as specific risk factors for prevalent AF. In patients with known AF in urban areas (n = 781) and rural areas (n = 338), 60.6% and 45.9%, respectively, received AF treatment (P < 0.01), and only 22.4% and 17.2%, respectively, received anticoagulation therapy (P = 0.05).
CONCLUSIONS
In China, there are urban-rural disparities in AF in the elderly, with a higher prevalence and worse management in rural areas than urban areas. Our study findings provide insight for health policymakers to consider urban-rural disparity in the prevention and treatment of AF.
5.Effects of continued use of targeted therapy on patients with pulmonary arterial hypertension and complicated by hemoptysis.
Zhong-Chao WANG ; Xiu-Min HAN ; Yao ZUO ; Na DONG ; Jian-Ming WANG ; Li-Li MENG ; Jia-Wang XIAO ; Ming ZHAO ; Yuan MI ; Qi-Guang WANG
Journal of Geriatric Cardiology 2025;22(3):404-410
6.Effect of Cinnamaldehyde on Systemic Candida albicans Infection in Mice.
Xiao-Ru GUO ; Xiao-Guang ZHANG ; Gang-Sheng WANG ; Jia WANG ; Xiao-Jun LIU ; Jie-Hua DENG
Chinese journal of integrative medicine 2025;31(7):644-648
OBJECTIVE:
To investigate the therapeutic efficacy of cinnamaldehyde (CA) on systemic Candida albicans infection in mice and to provide supportive data for the development of novel antifungal drugs.
METHODS:
Ninety BALB/c mice were randomly divided into 3 groups according to a random number table: CA treatment group, fluconazole (positive control) group, and Tween saline (negative control) group, with 30 mice in each group. Initially, all groups of mice received consecutive intraperitoneal injections of cyclophosphamide at 200 mg/kg for 2 days, followed by intraperitoneal injection of 0.25 mL C. albicans fungal suspension (concentration of 1.0 × 107 CFU/mL) on the 4th day, to establish an immunosuppressed systemic Candida albicans infection animal model. Subsequently, the mice were orally administered CA, fluconazole and Tween saline, at 240, 240 mg/kg and 0.25 mL/kg respectively for 14 days. After a 48-h discontinuation of treatment, the liver, small intestine, and kidney tissues of mice were collected for fungal direct microscopic examination, culture, and histopathological examination. Additionally, renal tissues from each group of mice were collected for (1,3)- β -D-glucan detection. The survival status of mice in all groups was monitored for 14 days of drug administration.
RESULTS:
The CA group exhibited a fungal clearance rate of C. albicans above 86.7% (26/30), significantly higher than the fluconazole group (60.0%, 18/30, P<0.01) and the Tween saline group (30.0%, 9/30, P<0.01). Furthermore, histopathological examination in the CA group revealed the disappearance of inflammatory cells and near-normal restoration of tissue structure. The (1,3)-β-D-glucan detection value in the CA group (860.55 ± 126.73 pg/mL) was significantly lower than that in the fluconazole group (1985.13 ± 203.56 pg/mL, P<0.01) and the Tween saline group (5910.20 ± 320.56 pg/mL, P<0.01). The mouse survival rate reached 90.0% (27/30), higher than the fluconazole group (60.0%, 18/30) and the Tween saline group (30.0%, 9/30), with a significant difference between the two groups (both P<0.01).
CONCLUSIONS
CA treatment exhibited significant therapeutic efficacy in mice with systemic C. albicans infection. Therefore, CA holds potential as a novel antifungal agent for targeted treatment of C. albicans infection.
Animals
;
Acrolein/pharmacology*
;
Candida albicans/physiology*
;
Mice, Inbred BALB C
;
Candidiasis/pathology*
;
Antifungal Agents/therapeutic use*
;
Mice
;
Fluconazole/therapeutic use*
;
Kidney/drug effects*
;
Female
7.Enhancement of Ca2+ Signal Strength in Astrocytes in the Lateral Septum Improves Cognitive Disorders in Mice After Hemorrhagic Shock and Resuscitation.
Wen-Guang LI ; Lan-Xin LI ; Rong-Xin SONG ; Xu-Peng WANG ; Shi-Yan JIA ; Xiao-Yi MA ; Jing-Yu ZHANG ; Gang-Feng YIN ; Xiao-Ming LI ; Li-Min ZHANG
Neuroscience Bulletin 2025;41(8):1403-1417
Hemorrhagic shock is a common clinical emergency that can aggravate cell injury after resuscitation. Astrocytes are crucial for the survival of neurons because they regulate the surrounding ionic microenvironment of neurons. Although hemorrhagic shock and resuscitation (HSR) injury can impair cognition, it remains unclear how this insult directly affects astrocytes. In this study, we established an HSR model by bleeding and re-transfusion in mice. The social interaction test and new object recognition test were applied to evaluate post-operative cognitive changes, and the results suggest that mice experience cognitive impairment following exposure to HSR. In the HSR group, the power spectral density of β and γ oscillations decreased, and the coupling of the θ oscillation phase and γ oscillation amplitude was abnormal, which indicated abnormal neuronal oscillation and cognitive impairment after HSR exposure. In brief, cognitive impairment in mice is strongly correlated with Ca2+ signal strength in lateral septum astrocytes following HSR.
Animals
;
Astrocytes/metabolism*
;
Shock, Hemorrhagic/metabolism*
;
Resuscitation/adverse effects*
;
Male
;
Mice
;
Calcium Signaling/physiology*
;
Mice, Inbred C57BL
;
Septal Nuclei/metabolism*
;
Cognitive Dysfunction/etiology*
;
Disease Models, Animal
;
Cognition Disorders/etiology*
9.Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection.
Geng-Yao ZHU ; Chao MA ; Guang-Wang LIU ; Jia-Zheng MAN
China Journal of Orthopaedics and Traumatology 2025;38(1):55-60
OBJECTIVE:
To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).
METHODS:
A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.8) years old. Of them, 46 were diagnosed as PJI(PJI group), including 22 males and 24 females. The mean age was (71.3±12.5) years old. The body mass index (BMI) was (26.4±3.1) kg·m-2. And 103 patients were diagnosed as aseptic prosthesis loosening (aseptic group), including 41 males and 62 females. The mean age was (68.7±11.4) years old. The BMI was (25.8±3.5) kg·m-2. Preoperatively analyzed clinical parameters included C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), albumin, globulin, albumin-to-globulin ratio (AGR), plasma D-dimer, and plasma fibrinogen. The receiver operating characteristic curve (ROC), sensitivity, and specificity analysis were employed to compare the diagnostic value of each blood marker in preoperative PJI diagnosis.
RESULTS:
In the PJI group, the levels of CRP were 16.6 (7.6, 4.5) mg·L-1, ESR was 17.0 (12.8, 35.5) mm·h-1, plasma D-dimer was 1.0 (0.5, 3.1) μg·L-1, and plasma fibrinogen was 4.2 (3.2, 3.1) mg·L-1;all of which were higher compared to the aseptic group with CRP at 4.2 (2.6, 7.8) mg·L-1, ESR at 12.0(8.0, 20.0 )mm·h-l, D-dimer at 0.4(0.2, 0.7)μg·L-1, and fibrinogen at 2.8(2.4, 3.3 ) g·L-1(P<0.05). However, the albumin level of 35.3 (32.3, 37.5) g·L-1 and the WBC ratio of 1.0(0.9, 1.1) in the PJI group were significantly lower compared to the aseptic group with levels of 39.8 (36.1, 41.8) g·L-1 and 1.4 (1.3, 1.5), respectively (P<0.05). Only the area under the curve (AUC) of AGR and plasma fibrinogen were greater than 0.8. The optimal predictive cut-1off, AUC, sensitivity and specificity were 3.4 g·L-1, 0.820, 69.57% and 84.47% for plasma fibrinogen; 1.18, 0.813, 82.61% and 78.64% for AGR, respectively.
CONCLUSION
AGR and plasma fibrinogen are promising blood markers for improving the diagnosis of PJI.
Humans
;
Female
;
Fibrinogen/metabolism*
;
Male
;
Middle Aged
;
Aged
;
Prosthesis-Related Infections/blood*
;
Retrospective Studies
;
Biomarkers/blood*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Leukocyte Count
10.Observation on the therapeutic effect of a modified Devine procedure with subcutaneous sliding fixation method for concealed penis.
Mohammed Abdulkarem AL-QAISI ; Hai-Fu TIAN ; Jia-Jin FENG ; Ke-Ming CHEN ; Jin ZHANG ; Yun-Shang TUO ; Xue-Hao WANG ; Bin-Cheng HUANG ; Muhammad Arslan Ul HASSAN ; Rui HE ; Guang-Yong LI
Asian Journal of Andrology 2025;27(4):470-474
To evaluate the therapeutic effect of a modified Devine procedure with a subcutaneous sliding fixation method for the treatment of congenital concealed penis, we retrospectively selected 45 patients with congenital concealed penises who were admitted to General Hospital of Ningxia Medical University (Yinchuan, China) between September 2020 and November 2023. In all cases, the penis was observed to be short, and retracting the skin at the base revealed a normal penile body, which immediately returned to its original position upon release. All patients underwent the modified Devine procedure with subcutaneous sliding fixation and completed a 12-week postoperative follow-up. A statistically significant increase in penile length was observed postoperatively, with the median length increasing from 4.0 (interquartile range [IQR]: 3.5-4.8; 95% confidence interval [CI]: 3.9-4.4) cm to 8.0 (IQR: 7.8-8.0; 95% CI: 7.7-7.9) cm, with P < 0.001. The parents were satisfied with the outcomes, including increased penile length, improved hygiene, and enhanced esthetics. Except for mild foreskin edema in all cases, no complications (such as infections, skin necrosis, or penile retraction) were observed. The edema was resolved within 4 weeks after the operation. This study demonstrates that the modified Devine procedure utilizing the subcutaneous sliding fixation method yields excellent outcomes with minimal postoperative complications, reduced penile retraction, and high satisfaction rates among patients and their families.
Humans
;
Male
;
Penis/abnormalities*
;
Retrospective Studies
;
Urologic Surgical Procedures, Male/methods*
;
Treatment Outcome
;
Child
;
Plastic Surgery Procedures/methods*

Result Analysis
Print
Save
E-mail