1.Results of the surveillance study of school lunch meals and drinking water in general education schools
Byambasuren B ; ; Ser-Od Kh ; Nandin-Erdene O ; Gantuya D
Mongolian Journal of Health Sciences 2026;91(1):54-57
Background:
Although food-borne infectious diseases occur across all age groups globally, evidence indicates that young children, older adults, and immunocompromised individuals are disproportionately affected due to their increased susceptibility to enteric pathogens. Young children in particular are at higher risk because their immune systems are not yet fully developed and they have lower body mass, which together reduce their ability to resist and recover from food-borne infections. In Mongolia, reported cases of intestinal infectious diseases in 2024 exceeded the ten-year historical average by 504.5 cases, and food- and water-related infections such as hand-foot-and-mouth disease, dysentery, and salmonellosis remain predominant among these conditions.
Aim:
The objective of this study was to conduct microbiological analyses of school lunches and drinking water provided to general education school students and to evaluate their compliance with relevant national standards.
Materials and Methods:
A total of 107 school lunch samples and 35 drinking water samples collected from general education schools were included in the study. Microbiological analyses were performed to assess hygiene and safety indicators, including Listeria monocytogenes, Salmonella spp., total coliform count, total viable microbial count (TVC), and intestinal bacteria. Laboratory analyses were conducted at the Microbiology Laboratory of the Food Safety Reference Laboratory under the Standardization and Metrology Authority. Confirmatory identification of microorganisms was performed using the VITEK 2 Compact system.
Result:
Of the 35 drinking water samples analyzed for 105 parameters, 8.5% (n=3) exceeded the permissible limits for total microbial counts. In the 107 school lunch food samples, a total of 428 microbiological parameters were examined, of which 26.1% (n=28) showed coliform counts above the allowable limits specified in the MNS 6308:2012 standard. Additionally, enterobacteriaceae were detected in 42.9% (n=46) of the food samples. When analyzed by school, 51.5% of the 35 schools (18 schools) had food samples with coliform counts that did not meet the standard requirements, whereas 49.5% (17 schools) showed compliance with the standards. These findings indicate that, on average, one out of every two schools fails to meet the required hygiene practices, proper food production procedures, and microbiological safety standards in meal preparation.
Conclusion
Microbiological analysis of 107 food samples from 35 general education schools across 428 indicators revealed that 26.1% did not meet the requirements of the MNS 6308:2012 “Microbiological safety and hygiene criteria for food products” standard due to excessive coliform counts. Of the 35 drinking water samples analyzed for 105 indicators, 5.7% (n=2) failed to meet the requirements of the MNS 0900:2018 “Drinking water: Hygiene requirements, quality, and safety assessment” standard with respect to total viable microbial count.
2.Clinical and demographic factors of long-term physical disability in patients with demyelinating diseases
Urantugs G ; Khaliun B ; Tuvshinjargal D ; ; Gantuya D ; Natsagdorj L
Mongolian Journal of Health Sciences 2026;91(1):72-78
Background:
Aetiological mechanisms of demyelinating diseases underlie a very heterogeneous clinical course, ranging from relapsing to progressive, with a longer disease duration leading to physical and cognitive disability.
Aim:
To identify factors in the development of long-term disability in demyelinating diseases.
Materials and Methods:
A cross-sectional study was conducted among 64 patients with multiple sclerosis and 33 patients with NMO treated at the Third State Central Hospital. We assessed demographic and clinical data, including the Expanded Disability Status Scale (EDSS). Statistical analysis included descriptive statistics, t-tests, chi-square tests, analysis of variance, correlation, and regression.
Result:
In MS, relapses (≥1) within 1.0 years of MS onset (OR=5.5, 95% CI 1.11-26.69, p=0.037), optic neuritis (OR=4.3, 95% CI 1.02-21.67, p=0.014), relapse frequency (≥3) (OR=6.6, 95% CI 1.39-31.3, p=0.018), myelitis frequency (≥2) (OR=5.5, 95% CI 1.42-21.67, p=0.014), in NMOSD, time from disease onset to diagnosis (≥3 month) (OR=7.9, 95% CI 1.04-60.7, p=0.046), years of diagnosis (≥3 years) (OR=6.3, 95% CI 1.15-34.12, p=0.034) contributed to disabilty worsening outcomes.
Conclusion
Disability in demyelinating diseases is affected by many factors.
3.Respiratory Symptoms Associated with Household Indoor PM2.5 Exposure
Ulziimaa D ; ; Ulziikhutag B ; Ser-Od Kh ; Shatar Sh ; Myagmarchuluun S ; Enkhjargal G ; Gantuya D ; Munkh-Erdene L ; Khurelbaatar N ; Damdindorj B ; Davaalkham D
Mongolian Journal of Health Sciences 2026;91(1):116-123
Background:
Numerous studies have shown that air pollution is a serious public health threat and risk worldwide. Mongolia is the world leader in outdoor and indoor air pollution, and the morbidity and mortality caused by it are increasing every year. People spend most of their lives indoors, and it is necessary to regularly assess and study indoor air pollution.
Aim:
To study the concentration of PM2.5 particles in the indoor air of households in Ulaanbaatar and Darkhan cities in relation to some symptoms of respiratory diseases.
Materials and Methods:
The study was conducted using an analytical cohort design from October 2023 to July 2025, and the 4 districts of the central Ulaanbaatar city and Darkhan cities were included in the study. A total of 240 households were included in the study, including 48 households living in ger and house, 24 households living in apartments, and 48 households living in ger and house, and 24 households living in apartments from Ulaanbaatar city. A direct measurement device (PurpleAir) was installed in the households for 3-4 weeks to measure PM2.5 particles in the indoor air for 24 hours. After measuring PM2.5 particles in the indoor air of the household, data were collected through questionnaires from the participants aged 18-60 who participated in the study and underwent health examinations. The results were processed using STATA-19.0 and R programs.
Result:
213-239 households were selected for the study, including households living in 17-26 apartments, 42-58 houses, and 38-50 houses. The 24-hour average concentration of PM2.5 particles in the ambient air of households in Ulaanbaatar city was measured relatively higher in winter and summer than in households in Darkhan city. Among the districts of Ulaanbaatar city, the highest concentration of PM2.5 particles was measured in Songinokhairkhan district, and the lowest concentration was measured in Bayanzurkh district. Considering the cities by heating type, households with stoves are more polluted than households with centralized heating. In Darkhan city, the lowest concentration was measured in apartments (22.78-31.53 μg/m³), houses (44.53-68.17 μg/m³), and the highest concentration was measured in traditional felt houses (houses) (63.20-68.25 μg/m³). In Ulaanbaatar, PM2.5 concentrations were relatively high in all types of housing, including apartments (41.61-58.37 μg/m³), houses (79.22-92.50 μg/m³), and traditional felt dwellings (76.69-86.31 μg/m³). In the summer, PM2.5 concentrations in Darkhan were 3.10-10.03 μg/m³ in apartments, 7.67-14.37 μg/m³ in houses, and 7.98-17.90 μg/m³ in traditional felt dwellings (houses). The concentration of PM2.5 particles in the ambient air of the settlement is statistically significantly associated with shortness of breath, fatigue, weakness, muscle pain, nausea, palpitations, sneezing, runny nose, conjunctivitis, pain in the eye socket, tearing of the eyes, headache, fever, nasal congestion, cough, loss of appetite, sore throat, phlegm, wheezing, and chest pain.
Conclusion
The 24-hour average concentration of PM2.5 particles in indoor air in households in Ulaanbaatar and Darkhan cities is higher than the Mongolian standard during winter and is statistically significantly associated with some symptoms of respiratory diseases.
4.Comparative study of outdoor and indoor air pollution in Ulaanbaatar and Darkhan cities
Davaalkham D ; ; Ulziikhutag B ; Batzorig B ; ; Ser-Od Kh ; ; Nyamsuren B ; ; Yerkebulan M ; ; Enkhjargal G ; ; Shatar Sh ; ; Myagmarchuluun S ; ; Gantuya D ; ; Ulziimaa D ; ; Buyantushig B ; ; Jargalsaikhan G ; ; Anujin M ; Maralmaa E ; Khurelbaatar N ; ; Damdindorj B ;
Mongolian Journal of Health Sciences 2026;93(3):107-113
Background:
Ambient and household air pollution remain leading risk factors for global morbidity and mortality. Exposure to fine particulate matter (PM₂.₅) is associated with increased risks of cardiovascular and respiratory diseases, as well as lung cancer, metabolic and neurological disorders, and immune dysfunction. In urban areas of Mongolia, air pollution reaches critical levels during the winter season. Although improved solid fuels have been introduced in recent years, their impact on both outdoor and indoor air quality remains insufficiently characterized.
Aim:
To compare outdoor and household air pollution levels in Ulaanbaatar and Darkhan cities.
Materials and Methods:
Outdoor air pollution data for Ulaanbaatar were obtained from fixed monitoring stations of the National Agency for Meteorology and Environmental Monitoring for the period 2014–2026, with seasonal comparisons performed. For indoor air quality assessment, a longitudinal study was conducted among 240 households (apartments, houses, and traditional gers) in Ulaanbaatar and Darkhan from 2023 to 2026. PM₂.₅ concentrations were measured using real-time sensors (PurpleAir sensor), deployed for 14–21 days per season (winter and summer) in each household, recording data at 10-minute intervals over 24-hour periods.
Result:
Between 2014 and 2026, the 24-hour mean concentrations in Ulaanbaatar were 60.5 µg/m for PM₂.₅, 117.3 µg/m for PM₁₀, 37.3 µg/m for NO₂, 41.8 µg/m for SO₂, and 27.5 µg/m for O₃. While particulate matter levels showed a decreasing trend following the introduction of improved fuels, SO₂ concentrations increased, and overall pollution levels remained higher than those observed in Darkhan. Indoor PM₂.₅ concentrations were higher in Ulaanbaatar compared to Darkhan (60.7±86.1 vs 48.4±96.7 µg/m). Significant differences were observed by housing type (p<0.0001), with higher concentrations in households using solid fuels (houses and gers) and lower levels in apartments. These findings indicate substantial variability in indoor air pollution by city, housing type, and season, with persistently elevated exposure levels.
Conclusion
Outdoor air pollutant concentrations in Ulaanbaatar, including particulate matter, NO₂, and SO₂, exceed national standards and WHO guideline values by 1–4 times. Indoor PM₂.₅ pollution is higher in Ulaanbaatar than in Darkhan and varies significantly by housing type and season, indicating a high and heterogeneous exposure burden among urban populations.
5.Results of using fecal calprotectin in the diagnosis of inflammatory bowel disease
Maral B ; Byambajav Ts ; ; Bira N ; ; Sugar B ; Zesemdorj O ; Khishgee D ; Gantuya B ; ; Tsevelnorov Kh ; ; Sainzaya B ; Munkh-Erdene Ts ; Saruuljavkhlan B ; ; Tuul B ; Pagamdulam L ; Sarantuya G ;
Mongolian Journal of Health Sciences 2026;95(5):77-81
Background:
Inflammatory bowel disease (IBD) is a chronic immune-related condition caused by interactions between genetics, immune dysfunction, gut microbiota changes, and environmental factors, often presenting as persistent or recurring diarrhea. Clinically, it commonly presents with chronic diarrhea and other gastrointestinal symptoms. The global prevalence of IBD is increasing, currently affecting approximately 0.5% of the population, with projections suggesting a rise to nearly 1% by 2030. Fecal calprotectin is a neutrophil-derived S100 calcium-binding protein that is elevated in intestinal mucosal inflammation and serves as a reliable noninvasive biomarker of inflammatory activity. Due to its high stability and close association with intestinal inflammatory activity, fecal calprotectin has been established as a dependable, non-invasive marker for identifying intestinal inflammation. In clinical practice, it is extensively used to distinguish IBD from functional gastrointestinal disorders, especially irritable bowel syndrome, among patients presenting with chronic diarrhea. However, its diagnostic utility in Mongolia remains underexplored, and this study aims to determine its sensitivity and specificity in inflammatory bowel disease and compare its diagnostic performance with other inflammatory markers.
Aim:
To determine the sensitivity and specificity of fecal calprotectin in inflammatory bowel disease and to compare it with other inflammatory markers.
Materials and Methods:
A total of 109 participants aged 18-87 years with chronic diarrhea, who attended the gastroenterology outpatient clinics of the Mongolia–Japan Hospital and Intermed Hospital between December 2024 and December 2025 and provided informed consent, were enrolled in this study. Data were collected using structured questionnaires, and laboratory investigations included complete blood count, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and measurement of fecal calprotectin levels from stool samples. Based on fecal calprotectin results, selected participants underwent colonoscopic examination as clinically indicated.
Results:
Among the 109 participants included in the study, 17.4% were diagnosed with inflammatory bowel disease (IBD), with a mean age of 47.41±15.52 years. Fecal calprotectin levels were significantly higher in the IBD group compared to the control group (p<0.001). Fecal calprotectin demonstrated a weak positive correlation with C-reactive protein (CRP) and leukocyte count (p=0.042, p=0.06), while no significant correlation was observed with erythrocyte sedimentation rate (ESR). At a cutoff value of 250 µg/g, fecal calprotectin showed a sensitivity of 94.4%, specificity of 69.2%, positive predictive value (PPV) of 37.8%, and negative predictive value (NPV) of 98.4%. Receiver operating characteristic (ROC) curve analysis identified an optimal cutoff value of approximately 400 µg/g (AUC=0.919, Youden index=0.724), at which the sensitivity remained 94.4% and specificity increased to 78.0%. In contrast, CRP and ESR demonstrated comparatively lower diagnostic performance, with AUC values of 0.640 and 0.644, respectively.
Conclusion
This study demonstrates that fecal calprotectin has superior diagnostic performance compared to conventional inflammatory markers in differentiating inflammatory bowel disease (IBD). An optimal cutoff value of approximately 400 µg/g yielded the highest sensitivity and specificity. Therefore, fecal calprotectin may serve as a valuable tool in clinical practice for both screening and diagnostic confirmation.
6.Results of the study on access to client-centered health services for people living with HIV
Khulan D ; Khishigdelger G ; Uugan-Oyun Ch ; Indra A ; Egshiglen S ; Davaajav Kh ; Oyunbeleg B ; Gantuya G ; Nyamtsengel V
Mongolian Journal of Health Sciences 2026;94(4):87-91
Background:
Transitioning HIV care toward a client-centered model is a key strategy for improving treatment outcomes and controlling the spread of HIV infection. Evaluating service accessibility, quality, and client satisfaction is essential for improving strategic planning and strengthening health service delivery.
Aim:
To assess the accessibility and quality of client-centered health services among people living with HIV.
Materials and methods:
A facility-based cross-sectional study was conducted. Data were collected using structured questionnaires from 50 clients and 30 health managers who participated voluntarily. The reliability of the questionnaire, measured using Cronbach’s alpha, ranged from 0.673 to 0.783. Data were analyzed using SPSS version 23.0 with both descriptive and analytical statistical methods. Quantitative variables were summarized using means and standard deviations, and statistical significance was determined at p < 0.05.
Results:
HIV-related services were found to be highly centralized at the NCCD, particularly for blood testing (96.8%) and inpatient care (71.4%). Overall, 84% of clients reported the need to access services outside NCCD, with the highest demand for internal medicine (32%), dental services (14%), and surgical services (14%). Among the barriers to accessing care, 75% were related to stigma and discrimination associated with HIV status, while 18% were linked to healthcare workers’ attitudes. In addition, 56.7% of healthcare facilities had not conducted HIV-related training, and only 40% had dedicated rooms ensuring confidentiality. Client satisfaction was strongly correlated with healthcare providers’ attitudes and communication (R = 0.614) and confidentiality (R = 0.578), both showing significant associations (p = 0.000).
Conclusion
HIV services remain highly centralized at NCCD, while the readiness of primary and referral healthcare facilities remains insufficient. Strengthening a client-centered care approach requires improving healthcare workers’ attitudes and communication, ensuring confidentiality, and implementing continuous HIV-related training for healthcare providers.
7.Study results of PM1 and PM10 particulate matter concentrations in Ulaanbaatar city’s household environments using low-cost sensors.
Ulziimaa D ; Jargalsaikhan G ; Ser-Od Kh ; Enkhjargal G ; Myagmarchuluun S ; Gantuya D ; Munkh-Erdene L ; Damdindorj B ; Khurelbaatar N ; Davaalkham D
Mongolian Journal of Health Sciences 2025;88(4):88-91
Background:
According to the World Health Organization (WHO), 99 percent of the world’s population is exposed to air
that exceeds WHO recommendations, with low- and middle-income countries being the most affected. The main causes
of indoor air pollution include human activities such as fuel burning, cooking, cleaning, and smoking; housing characteristics such as walls, floors, ceilings, and furniture; ventilation; and outdoor air pollution.
Aim :
To assess PM1 and PM10 concentrations in 120 selected households in Ulaanbaatar.
Materials and Methods :
Indoor PM1 and PM10 concentrations were measured using Purple Air real-time sensors in
randomly selected Ulaanbaatar households between October 2023 and January 2024. Supplementary data on factors affecting the PM2.5 concentration were collected via questionnaires. Each measurement was taken in 10-minute intervals,
yielding 51,309 data for analysis.
Results :
PM1 concentrations were measured at 55.5±53.2 μg/m³ in gers, 54.9 ± 46.7 μg/m³ in houses, and 31.6±40.1 μg//m³ in apartments (p<0.001) and measuring PM10 concentrations were 110.6±108.6 μg/m³ in gers, 110.6±96.7 μg/m³ in
houses, and 62.2±83.0 μg/m³ in apartments (p<0.001) When considering the concentration of PM1, PM10 by heating
type, PM1 was 55.3±50.1 μg/m³ and PM10 was 110.6±103.0 μg/m³ in households with stoves and furnaces, and PM1
was 31.6±40.1 μg/m³ and PM10 was 62.2±83.0 μg/m³ in households connected to the central heating system (p<0.001).
Regarding the months of measurement, the highest concentration was observed in December 2023, at 77.1±94.1 μg/m³. The highest concentrations for both PM₁ and PM₁₀ were recorded in January 2024, at PM₁: 64.8±55.1 μg/m³, PM₁₀:
131.4±116.0 μg/m³.
Conclusion
1. Indoor PM10 concentrations in residential environments in Ulaanbaatar city were within the MNS4585:2016 Air
Quality Standard, however, it was exceeded the WHO air quality guidelines, indicating an excessive risk of increasing morbidity and mortality among the population.
2. Indoor PM1 and PM10 concentrations in residential environments in Ulaanbaatar varies depending on location, type
of housing, type of heating, and month of measurement.
8. Rising prevalence of demyelinating disorders in Mongolia
Urantugs G ; Nyamsuren B ; Gantuya D ; Natsagdorj L
Mongolian Journal of Health Sciences 2025;88(4):238-243
Background:
Demyelinating disorders are a group of chronic immune-mediated diseases affecting myelinated axons in
the central nervous system, which lead to life-long disability. In Mongolia, the last regional prevalence study was conducted in 2010. Our study objective is to describe the current prevalence of multiple sclerosis (MS) and other demyelinating
disorders in Mongolia.
:
Aim
Materials and Methods:
We registered MS, neuromyelitis optica spectrum disease (NMOSD), myelin oligodendrocyte
glycoprotein (MOG), and acute disseminated encephalomyelitis (ADEM) cases diagnosed according to the 2017 McDonald criteria, the 2023 NMOSD diagnostic criteria, International MOGAD Panel proposed criteria.
Results:
The study was conducted in all tertiary, 7 regional, and 20 provincial hospitals across Mongolia and has collected
comprehensive data on 965 patients. The prevalence of total demyelinating disorders was estimated to be 27.2, MS 15.6,
NMOSD 5.6, MOG 0.06, and ADEM 0.9 per 100,000 total population, respectively. The prevalence of demyelinating
disorders between provinces was compared in order of geographical latitude, from lowest to highest, and was statistically
significant. Latitude is associated strongly with the prevalence of demyelinating disorders (p=0.006, 95% CI 14.3-22.4,
Pearson correlation=0.603) and moderately with the prevalence of MS (p=0.028, 95% CI 9.39-15.6, Pearson correla
tion=0.503).
Conclusion
In Mongolia, the prevalence of MS has significantly increased and can be considered at medium risk, but
still much lower than that in Western countries. The prevalence of NMOSD is almost similar to other Asian countries. An obvious latitude gradient for demyelinating disorders was observed in the Mongolian population.
9.Indoor Particulate Matter Concentration in Households of Darkhan City
Nyamdorj J ; Bolor M ; Maralmaa E ; Yerkyebulan M ; Ser-Od Kh ; Myagmarchuluun S ; Shatar Sh ; Gantuya D ; Gregory C. Gray ; Junfeng Zhang ; Ulziimaa D ; Damdindorj B ; Khurelbaatar N ; Davaalkham D
Mongolian Journal of Health Sciences 2025;85(1):25-29
Background:
A 2018 study on the global burden of disease, accidents, and risk factors reported that 1.6 million peo
ple died in 2017 due to household air pollution. Poor indoor air quality has been highlighted as a contributing factor to
respiratory diseases, cardiovascular conditions, and exacerbation of asthma and allergies. A 2019 study estimated that
long-term exposure to fine particulate matter (PM2.5) with a diameter of 2.5 micrometers or less reduces average life
expectancy by 1.8 years, with more severe effects in highly polluted regions. Additionally, a study by Miller et al. (2007)
found that prolonged exposure to PM2.5 increases the risk of cardiovascular diseases, particularly among women. Direct
measurement devices are highly effective in determining indoor PM2.5 concentrations, identifying sources of pollution,
tracking pollutant dispersion, and monitoring temporal variations. Studies suggest that direct measurement is an accurate,
cost-effective method that provides detailed data suitable for local conditions.
Aim:
To investigate the indoor air quality of houses and apartments in Darkhan city during the winter season using the
Purple Air monitoring device.
Materials and Methods:
A cross-sectional study was conducted with a targeted sample of 128 households in Darkhan
city. The study examined factors such as stove type, type of coal used, annual and daily coal consumption, frequency of
heating, and chimney sealing conditions. To collect data, the Purple Air monitoring device was installed in each house
hold for a month, after which it was retrieved. During retrieval, participants completed a questionnaire. The questionnaire
consisted of 55 questions across 7 pages at the time of device installation and 25 questions across 3 pages at the time of
device retrieval. The collected data was analyzed using SPSS 25.0.
Results:
A total of 128 households in Darkhan city participated in the study. The average duration of residence in the
current home was 9.5 years, with no statistically significant variation. The distribution of housing types was as follows:
traditional Mongolian gers (40.6%), houses (39.1%), and apartments (20.3%). The 24-hour average PM2.5 concentration
was highest in gers (70.9 μg/m³), followed by houses (46.8 μg/m³) and apartments (22.8 μg/m³), with a statistically significant difference (p=0.0001). PM2.5 levels were most variable in gers, followed by houses and then apartments. House
holds using central heating (apartments) had an average 24-hour PM2.5 concentration of 22.8 μg/m³, whereas households
using stoves (gers and houses) had a significantly higher concentration of 59.4 μg/m³ (p=0.0001). However, there was
no statistically significant difference between traditional and improved stoves. Among study participants, 21.4% reported
that someone in their household smoked indoors. Additionally, 86.5% regularly burned incense, candles, or herbs, while
99.2% did not use an air purifier.
Conclusion
The indoor particulate matter concentration in houses and gers in Darkhan was 59.4μг/m3. Variations in
stove types, poor chimney sealing limited space, and frequent gaps and cracks contribute to increased spread of indoor
air pollutants.
10.Determination sugar and brix content in Mongolian sugar-sweetened beverages
Nyamsuren A ; Khaliun B ; Uranchimeg L ; Nandin-Erdene O ; Gantuya D
Mongolian Journal of Health Sciences 2025;85(1):30-34
Background:
The main risk factors for childhood overweight and obesity include the consumption of sugar-sweetened
beverages and other sweetened foods. The sugar content of sugar-sweetened beverages was different from the nutritional
information on the packaging.
Aim:
To determine sugar and brix content in domestic manufactured sugar-sweetened beverages, and compare information on the packaging and regulatory standards.
Materials and Methods:
The sugar and brix content in sugar-sweetened beverages was determined by laboratory anal
ysis, including 150 domestically manufactured sugar-sweetened beverages. Laboratory analysis carried out in the Chemical toxicology laboratory of the National Reference Laboratory for Food Safety, MASM, determined sugar using a
saccharometer and brix using refractometry.
:
Results: The study included 150 Mongolian sugar-sweetened beverages, including 20.7% (n=31) carbonated drinks,
47.3% (n=71) fruit drinks, 16.0% (n=24) tea drinks, 1.3% (n=2) energy drinks, 14.7% (n=22) flavored water. Sugar content 0.0–15.6% in sugar-sweetened beverages. The laboratory analysis results compared with information on the packaging 72.0% (n=108) difference between 0.1–11.3%, 10.7% (n=16) same, do not have sugar content in the nutritional information on the packaging 17.3% (n=26). Brix contained 0.2–13.0% carbonated drinks, 4.9–15.7% fruit drinks, 0.6–9.8%
tea drinks, 7.7–16.0% energy drinks, and 0.1–9.7% flavored water.
Conclusions
1. Sugar content 0.0–15.6%, brix 0.0–16.0% in Mongolian sugar-sweetened beverages.
2. The laboratory analysis results compared with nutritional information on the packaging 72.0% (n=108) difference
between 0.1–11.3%, 10.7% (n=16) same nutritional information on the packaging, do not have sugar content in the
nutritional information on the packaging 17.3% (n=26).
3. 37.3% of Mongolian sugar-sweetened beverages are unsatisfied with regulatory standards.
Result Analysis
Print
Save
E-mail