1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Testis-sparing microsurgery for benign testis tumor:A report of 16 cases
Lei YU ; Jing ZHAO ; Hong-Qiang WANG ; Pei-Hong ZHOU ; Jian-Hua MEN ; Gang WANG ; Qiang LI ; Yu PAN ; Wen-Xin LI ; Lin QIAN ; Shen-Qian LI ; Pei-Tao WANG ; Tao JING
National Journal of Andrology 2024;30(3):209-216
Objective:To investigate the safety and clinical effect of testis-sparing microsurgery(TSMS)in the treatment of benign testis tumor(BTT).Methods:We retrospectively analyzed the clinical data on 16 cases of BTT treated in the Department of Andrology of the Affiliated Hospital of Qingdao University from October 2020 to February 2023.The median age of the patients was 23 years.All the tumors were unilateral,7 in the left and 9 in the right side,with a median diameter of 1.85 cm(1.0-3.5 cm).The patients all underwent color Doppler flow imaging(CDFI),MRI,semen analysis and examination of serum T,alpha-fetoprotein(AFP),human chorionic gonadotropin(HCG)and lactate dehydrogenase(LDH),followed by TSMS.The boundaries between the tumors and normal testis tissue were accurately identified under the microscope,and the tumors and the adjacent normal testis tissue 2 mm from their margins were excised completely.Bipolar coagulation forceps were used for wound hemostasis to maximally preserve the normal testis tissue.The resected specimens were subjected to fast frozen pathology intraoperatively,and the patients were followed up for 14-40 months by regular scrotal CDFI,MRI and examinations of serum T and semen parameters.Results:The levels of serum T,AFP,HCG and LDH and semen parameters were all within the normal range preoperatively.TSMS were successfully completed in all the cases,and all were pathologically confirmed as BTT according to the latest edition of WHO Classification of Tumors:Urinary and Male Genital Tumors.CDFI showed normal blood supply within the testis tissue at 1 month after surgery.No signs of intra-testicu-lar tumor residue,recurrence or metastasis,nor significant changes in the levels of serum T,AFP,HCG or LDH or semen parameters were observed during the follow-up as compared with the baseline.Natural conception was achieved in 2 cases at 16 and 18 months re-spectively after surgery.Conclusion:BTT can be differentially diagnosed by CDFI and MRI before surgery and confirmed by histo-pathology.TSMS can achieve complete excision of the tumor,maximal sparing of the normal testis tissue and thereby effective preserva-tion of male fertility.
7.Chemical constituents from Codonopsis pilosula in Shanxi and their anti-inflammatory activities
Yan-Gang CHENG ; Pei LI ; Si-Qi YANG ; Xiang-Peng KONG ; Hui-Feng LI ; Yan WANG ; Jin-Yan TAN ; Ying-Li WANG
Chinese Traditional Patent Medicine 2024;46(7):2265-2271
AIM To study the chemical constituents from Codonopsis pilosula(Franch.)Nannf in Shanxi and their anti-inflammatory activities.METHODS The 70% ethanol extract from C.pilosula in Shanxi was isolated and purified by silica gel,ODS and preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their in vitro anti-inflammatory activities were evaluated by RAW264.7 model.RESULTS Sixteen compounds were isolated and identified as ethylsyringin(1),7-O-ethyltangshenoside Ⅱ(2),triandrin(3),trans-isoconiferin(4),methylsyringin(5),9-acetoxy syringin(6),cordifolioidyne B(7),codonopiloenynenoside A(8),codonopilodiynoside F(9),pratialin B(10),lobetyolinin(11),lariciresinol-4-O-β-D-glucoside(12),dihydrodehydrodiconiferyl alcohol 4′-O-β-D-glucoside(13),atractylenolid Ⅲ(14),baimantuoluoamide B(15),benzyl primeveroside(16).Compounds 1-2,5,7-11 and 13-15 had certain anti-inflammatory activities,among which compounds 11,14-15 had higher activities,whose IC50 values were(18.23±4.18),(17.73±3.12),(14.89±2.47)μmol/L,respectively.CONCLUSION Compounds 3,6,13,16 are first isolated from Campanulaceae,2,5,15 are first found from this plant.Compounds 11,14 and 15 have good anti-inflammatory activities.
8.Survey on the basic situation and quality safety of radiation therapy in Hunan province
Biao ZENG ; Shixiong HUANG ; Xiangshang SUN ; Songhua YANG ; Qianxi NI ; Pei YANG ; Xuelian XIAO ; Gang HUANG ; Yaqian HAN ; Yingrui SHI
Chinese Journal of Radiation Oncology 2024;33(6):499-505
Objective:To investigate the current status and quality and safety of radiation therapy resources in medical institutions in Hunan province.Methods:The basic situation questionnaire, quality and safety self-assessment form were designed according to the content of the survey, distributed and recovered through the network, and the survey was conducted on all medical institutions (excluding military hospitals) conducting radiotherapy in Hunan province in 2022, and the quality and safety evaluation was checked by the Hunan Radiotherapy Quality Control Center using stratified sampling field inspection. The differences between the self-evaluation scores of radiotherapy quality and safety and the on-site inspection scores of each unit was compared using Wilcoxon test.Results:By the end of 2022, there were 76 medical institutions (excluding military hospitals) conducting radiotherapy in Hunan province, including 62 tertiary hospitals and 14 secondary hospitals, with a total of 44 253 radiotherapy patients admitted annually. The total number of personnel engaged in radiotherapy was 1 381, including 746 physicians, 205 physicists, 397 technicians and 33 maintenance engineers. There were a total of 88 accelerators (including 3 tomotherapy units), 10 gamma knives, and 28 rear-loading machines, with 1.33 gas pedals per million population. There were 36 units that were carrying out three-dimensional conformal technology, 60 static intensity modulation technology, 20 volumetric rotational intensity modulation, 27 stereotactic radiotherapy, 44 image-guided radiotherapy, 33 respiratory motion management, and 27 rear-loading radiotherapy. In the quality and safety evaluation situation, the basic requirements of radiotherapy specialty scored high, with 2 units achieving full marks and no failing units. Radiotherapy personnel and organization, radiotherapy process, documentation record score and other aspects of no full-score units, the score was concentrated in 60~<80 points, and all have part of the unit failed.Conclusions:The radiotherapy industry in Hunan province has been developed steadily in recent years in general, and the structure of radiotherapy personnel tends to be reasonable, but there still exists uneven distribution of radiotherapy resources, poor utilization of equipment in some areas, and inadequate development of technology. The overall quality and safety evaluation are good, but there are still many deficiencies in the organizational requirements of radiotherapy personnel, process requirements and documentation, which need to be continuously optimized and improved in the future, and at the same time, field inspections will be intensified to ensure the quality and safety of radiotherapy.
9. Advances in relationship between pyroptosis and pulmonary arterial hypertension and therapeutic drugs
Qian YAN ; Yang SUN ; Jun-Peng LONG ; Jiao YAO ; Yu-Ting LIN ; Song-Wei YANG ; Yan-Tao YANG ; Gang PEI ; Qi-Di AI ; Nai-Hong CHEN ; Qian YAN ; Yang SUN ; Jun-Peng LONG ; Jiao YAO ; Yu-Ting LIN ; Song-Wei YANG ; Yan-Tao YANG ; Gang PEI ; Qi-Di AI ; Nai-Hong CHEN ; Sha-Sha LIU ; Nai-Hong CHEN
Chinese Pharmacological Bulletin 2024;40(1):25-30
Pyroptosis is the programmed death of cells accompanied by an inflammatory response and is widely involved in the development of a variety of diseases, such as infectious diseases, cardiovascular diseases, and neurodegeneration. It has been shown that cellular scorching is involved in the pathogenesis of pulmonary arterial hypertension ( PAH) in cardiovascular diseases. Patients with PAH have perivascular inflammatory infiltrates in lungs, pulmonary vasculopathy exists in an extremely inflam-matory microenvironment, and pro-inflammatory factors in cellular scorching drive pulmonary vascular remodelling in PAH patients. This article reviews the role of cellular scorch in the pathogenesis of PAH and the related research on drugs for the treatment of PAH, with the aim of providing new ideas for clinical treatment of PAH.
10.Identification of potential pathogenic genes of intestinal metaplasia based on transcriptomic sequencing and bioinformatics analysis
Bei PEI ; Yi ZHANG ; Siyuan WEI ; Yu MEI ; Biao SONG ; Gang DONG ; Ziang WEN ; Xuejun LI
Journal of Southern Medical University 2024;44(5):941-949
Objective To explore the potential pathogenic genes of intestinal metaplasia.Methods Twenty-one patients with intestinal metaplasia admitted to the Department of Gastroenterology at the Second Affiliated Hospital of Anhui University of Chinese Medicine from January,2022 to June,2022,and 21 healthy subjects undergoing gastroscopic examination during the same period were enrolled in this study.All the participants underwent gastroscopy and pathological examination,and gastric tissue samples were collected for transcriptome sequencing to screen for differentially expressed genes(DEGs).The biological functions of the DEGs were analyzed using bioinformatics analysis,and qRT-PCR was used to validate the results.Results Transcriptomic sequencing identified a total of 1373 DEGs,including 827 upregulated and 546 downregulated ones.The top 6 upregulated genes(AGMAT,CCL25,FABP1,CDX1,SPINK4,and MUC2),ranked based on their significance and average expression level,were selected for validation,and qRT-PCR showed significant upregulation of their mRNAs in the gastric tissues of patients with intestinal metaplasia(P<0.05).Conclusion AGMAT,CCL25,FABP1,CDX1,SPINK4,and MUC2 participate in the occurrence and development of intestinal metaplasia,and may serve as potential biomarkers for diagnosing intestinal metaplasia.

Result Analysis
Print
Save
E-mail