1.Dosimetric evaluation of 125I seed implantation assisted by an optical navigation system and a 3D-printing template in the treatment of recurrent head and neck cancers
Xiuwen DENG ; Zhe JI ; Yuliang JIANG ; Haitao SUN ; Fuxin GUO ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(1):3-8
Objective:To verify the accuracy and feasibility of radioactive 125I seed implantation assisted by an optical navigation system and a 3D-printing non-coplanar template in the treatment of recurrent head and neck cancers. Methods:A total of 12 patients with recurrent head and neck cancer treated with radioactive 125I seed implantation assisted by an optical navigation system and 3D-printing non-coplanar template were enrolled from Dec 2018 to Dec 2019.The pre-plan and post-implant implantation needle number and implanted seed number were recorded.Meanwhile, their dosimetric parameters were compared, including D90, minimum peripheral dose (MPD), V100, V150, V200, conformity index (CI), external index (EI), and the homogeneity index (HI) of the target volume. Results:The median lesion volume was 31.5 cm 3, the median number of seeds was 61.5, and the median prescription dose was 130 Gy.The means of the pre-plan D90, MPD, V100, V150 and V200 were 134.2, 64.6, 93.3, 75.3 and 39.3 Gy, respectively, while those of post-implant D90, MPD, V100, V150, and V200 were 146.7, 68.94, 97.47, 80.40 and 48.30 Gy, respectively, with no statistically significant difference ( P>0.05). Meanwhile, there was no statistically significant difference between the pre-plan and post-implantation needle number, implanted seed number, CI, HI, and EI ( P>0.05). In terms of postoperative dose quality assessment, eight cases were rated excellent (66.6%) and four cases were rated good (33.3%). Conclusions:Radioactive 125I seed implantation assisted by an optical navigation system and 3D-printing non-coplanar template can be accurately performed in the treatment of recurrent head and neck cancer, with good consistency between pre-plan and post-implant dosimetric parameters and thus of prospective potential in clinical application.
2.Preoperative dosimetric comparison between non-coplanar and coplanar template-assisted 125I seed implantation for pancreatic cancers
Haitao SUN ; Junjie WANG ; Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Yi CHEN ; Jinghong FAN
Chinese Journal of Radiological Medicine and Protection 2021;41(1):42-45
Objective:To compare preoperative planning parameters between non-coplanar and coplanar template-assisted radioactive seed implantation in the treatment of pancreatic cancers, in order to guide clinical application.Methods:Patients with pancreatic cancers who received external irradiation in the Peking University Third Hospital from Jan 2017 to May 2019 were selected.Their image information was imported into the brachytherapy planning system, and the non-coplanar plan and coplanar plan were designed individually.Each patient′s prescription dose was set to 110 Gy, and the activity of the radioactive seeds were 0.4 mCi(1 Ci=3.7×10 10Bq), respectively.For the two plans, the dose distribution was optimized and dosimetric parameters were compared, including the implantation needle number, the implanted seed number, the minimum prescription doses delivered to 90% and 100% of the target volume ( D90 and D100), mean percentages of volume receiving 100%, 150% and 200% of the prescription doses ( V100, V150 and V200), conformity index (CI), external index (EI), and homogeneity index (HI) of the target volume, as well as the doses of 2 cm 3 and 5 cm 3 ( D2 cm 3 and D5 cm 3) of the surrounding normal organs such as the small intestines, colon, duodenum, stomach, and spinal cord. Results:The implantation needle number in the coplanar plan was slightly higher than that in the non-coplanar plan, namely 18.63 vs. 16.45 ( t=-3.239, P <0.05). The implanted seed number was equivalent, namely 90.2 vs. 91.01, with no statistical difference ( P>0.05). There was no significant difference between D90, D100, V100, V150, V200, CI, EI, and HI in the target area of the two plans ( P>0.05). Meanwhile, there was no obvious difference in D2 cm 3 and D5 cm 3 of normal organs including the small intestines, colon, duodenum, stomach, and spinal cord ( P>0.05). Conclusions:With both the coplanar plan and the non-coplanar plan, the prescription doses can be achieved and meanwhile, there are very small differences in the doses of normal organs.Given that 3D-printing non-coplanar and coplanar templates have their own characteristics, it is necessary to choose them according to specific situations.
3.Dosimetry evaluation of navigation system-assisted and CT-guided seed implantation in the treatment of recurrent malignant pelvic tumors
Ping JIANG ; Zhe JI ; Yuliang JIANG ; Fuxin GUO ; Haitao SUN ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(1):50-55
Objective:To explore the accuracy of CT-guided 125I seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors by comparing pre-plan and intraoperative physical dosimetric parameters. Methods:This study involved 15 patients with recurrent malignant pelvic tumors who received CT-guided radioactive 125I seed implantation assisted by a navigation system and 3D-printing template in the Peking University Third Hospital from Dec 2018 to Feb 2020.Seven of the patients had cervical cancers, seven had rectal cancers, and one had prostate cancer.The median age was 55 years (34-84 years old). The prescription dose was 100-150 Gy.The pre-plan and post-implant data were compared, including the number of implanted seeds, implantation needle number, and some dosimetric parameters such as the minimum prescription doses delivered to 90% and 100% of target volume( D90, D100), mean percentages of volume receiving 100%, 150%, and 200% of the prescription doses( V100, V150, and V200), conformity index(CI), external index(EI), and homogeneity index(HI)of the target volume. Results:The median lesion volume was 29.20 cm 3, the median seed number was 54, and the median D90 was 150 Gy.The post-implant V150 was lower than pre-plan V150 (64.1% vs. 67.1%, t=2.937, P=0.011), and the post-implant mean HI was higher than pre-plan HI (32.01% vs. 26.68%, t=-2.950, P=0.011). There were no significant differences in other dosimetric parameters before and after seed implantation. Conclusions:With CT-guided radioactive seed implantation assisted by a navigation system and 3D-printing template in the treatment of recurrent malignant pelvic tumors, the actual postoperative dose could meet the preoperative plan requirement, ensuring the accuracy and consistency of the dose delivered.
5.The mechanism of chelerythrine against breast cancer by network pharmacology and molecular docking
Lei ZHANG ; Min WANG ; Xinxin ZHANG ; Xinyue ZHANG ; Fuxin ZHANG ; Zhen CAO ; Hui ZHANG ; Zengjun GUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2021;42(4):554-561,573
【Objective】 To investigate the mechanisms of chelerythrine on the treatment of breast cancer based on network pharmacology and molecular docking. 【Methods】 The targets corresponding to chelerythrine and breast cancer were obtained from Mala Cards and Swiss Target Prediction databases. Chelerythrine-related and breast cancer-related targets were found and then combined to get an intersection, which represented potential anti-breast cancer targets of chelerythrine. A protein-protein interaction (PPI) network was constructed from the STRING database and key genes were screened using the topological analysis. Gene ontology (GO) and kyoto encyclopedia of genes and genomes (KEGG) enrichment analysis of targets were conducted using metascape database. The relationship between the expressions of key target genes and the survival curve was analyzed using the Kaplan-Meier Plotter database. Molecular docking analysis was performed by AutoDock Vina to verify whether chelerythrine has a definite affinity with key targets. 【Results】 A total of 37 potential targets were obtained in chelerythrine against breast cancer. The result of the topology analysis included 8 key targets. The GO enrichment analysis included 317 GO items. The KEGG pathway analysis included 80 pathways, which were closely related to the PI3K/AKT signaling pathway, the ErbB signaling pathway, VEGF signaling pathway, and others. The results of the survival curve analysis showed that the expression levels of CHEK1, PIK3CA, mTOR and PTGS2 genes were related to the survival time of breast cancer patients. The results of molecular docking proved that the combined activity of chelerythrine with key targets was excellent. 【Conclusion】 Chelerythrine may play an anti-breast cancer role via the PI3K/AKT signaling pathway and has the potential to be developed into a clinical drug for breast cancer.
6. Dosimetric analysis of 3D-printing non-coplanar template combined with CT-guided125I seed implantation for the treatment of spinal metastasis
Jianing CUI ; Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Ran PENG ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiation Oncology 2020;29(2):122-125
Objective:
To compare the preoperative and postoperative dosimetric parameters in the treatment of spinal metastasis, and to verify the accuracy of 3D-printing non-coplanar template (3D-PNCT) combined with CT-guided 125I seed implantation for the treatment of spinal metastasis.
Methods:
The treatment plans of 7 patients with spinal metastasis (9 lesions) from 2016 to 2018 receiving 3D-PNCT in combination with CT-guided 125I seed implantation were retrospectively analyzed. The dosimetric parameters including homogeneity index (HI), conformal index (CI), external index (EI), dose of 90% target volume(D90), mPD, volume percent of 100%, 150%, and 200% prescribed dose V100、V150、V200 and D2cm3 of spinal cord were compared before and after operation. The british columbia cancer ageny particle implantation quality evaluation standard was applied to evaluate the quality of implantation.
Results:
The HI, EI and CI, D90, mPD, V100, V150, V200 and D2cm3 of spinal cord did not significantly differ before and after the plan (all
7.Dosimetry evaluation of three-dimensional-printing template guided radioactive seeds implantation assisted by navigation system in malignant tumors
Zhe JI ; Yuliang JIANG ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Junjie WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2020;40(11):641-646
Objective:To compare the difference of preoperative and postoperative plans of navigation-assisted three-dimensional (3D)-printing template combined with CT-guided radioactive 125I seeds implantation for malignant tumors, and verify preliminarily the plan quality of optical navigation-assisted seeds implantation. Methods:From December 2018 to November 2019, a total of 20 patients (10 males, 10 females, median age: 60.5 years) with malignant tumors received navigation-assisted 3D-printing template combined with CT-guided radioactive 125I seeds implantation in Peking University Third Hospital. Eight cases were implanted in the head and neck, 1 case in the chest wall, 9 cases in the pelvis and 2 cases in the paravertebral and/or retroperitoneal region. The median prescription dose was 150 Gy. The data in the preoperative and postoperative plans was compared, including seeds number, needles number, and some dosimetry parameters. Dosimetry parameters including dose delivered to 90% gross tumor volume (GTV) ( D90), percentage of GTV received 100%, 150%, and 200% of the prescribed dose ( V100, V150, V200), minimum peripheral dose (MPD), conformal index (CI), external index (EI), homogeneity index (HI) of target volume, and 2 cm 3 range of spinal cord receiving dose ( D2 cm 3). Paired t test and Wilcoxon signed rank test were used to analyze the data. Results:The needles number of preoperative and postoperative plans was the same (both 12 (9, 19)), and the seeds number of postoperative plan was more than preoperative plan with no significant difference (51(35, 68) vs 49(35, 63); z=1.859, P>0.05). The MPD of postoperative plans was higher than preoperative plans ((80.52±14.89) vs (67.22±20.56) Gy, t=-3.769, P=0.001). There were no significant differences in other dosimetry parameters between the two plans ( t values: -0.533, -0.423, z values: from -0.849 to 1.416, all P>0.05). Postoperative dose quality assessment was excellent in 17 cases (17/20), good in 2 cases (2/20) and middle in 1 case (1/20). Conclusions:The quality of the implantation is good under the guidance of combined mode. The actual target dose after operation can meet the requirements of preoperative planning.
8.Dosimetric study of 125I seed implantation by 3D-printing coplanar template for pelvic wall recurrent cervical cancer after radiotherapy
Ang QU ; Ran PENG ; Yuliang JIANG ; Ping JIANG ; Zhe JI ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(10):756-760
Objective To investigate the feasibility of 3D-printing coplanar coordinate template (3D-PCT) for guiding 125I radioactive seed implantation in the treatment of pelvic wall recurrence of cervical cancer on ensuring the accuracy of dose.Methods From Oct 2016 to Dec 2017 in Peking University Third Hospital,totally 10 patients with pelvic wall recurrent cervical cancer after radiotherapy were treated with 125I radioactive seed implantation assisted by 3D-PCT.The median age was 53.5 years old (37-71 years old).KPS score of the cohort were more than 70.All patients had received pelvic radiation therapy previously.The median volume of the lesion was 31.9 cm3 (3.5-58.0 cm3).The prescription dose was 120-180 Gy.The activity of seeds was 0.55-0.67 mCi(1 Ci =3.7 × 1010Bq),while the number of seeds was 12-81 (median 50) on preoperative plan.Radioactive seeds implantation was performed under 3D-PCT guidance according to the preoperative plan.The actual number of implanted seeds was 53 (10-82).Dosimetry parameters of preoperative plan and postoperative plan including D90,D100,V100,V150,V200,external index (EI),conformal index (CI),heterogeneity index (HI),and organat-risk doses of D2 cm3,D1 cm3 and D0.1 cm3 were compared using the nonparametric test.Results The seed number of postoperative plan was more than that of preoperative plan (Z =-2.255,P < 0.05),but all of the dosimetric parameters showed no significant difference (P > 0.05).D2 cm3 and D1 cm3 of rectum for postoperative plan were lower than that of preoperative plan (Z =-2.100,-2.240,P < 0.05),while other dose parameters of normal tisssues showed no statistically significant difference (P > 0.05).Conclusions Assisted by 3D-PCT for 125I radioactive seed implantation in pelvic wall recurrence of cervical cancer,the actual postoperative dose could meet the requirement of the preoperatie plan through the intraoperative optimization of dose.3D-PCT could ensure the precise of delivered dose of 125I radioactive seed implantation.
9.Dosimetry verification of radioactive seed implantation for recurrent malignant tumor of head and neck assisted by 3D printing individual guide plate
Yuliang JIANG ; Zhe JI ; Fuxin GUO ; Haitao SUN ; Jinghong FAN ; Weiyan LI ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(11):842-845,858
Objective To compare the dose distributions of postoperative plans with preoperative plans for 3D printing guide plate assist radioactive seeds implantations, explore the effects of the technology for seeds implantations in dosimetry level. Methods From January 2016 to December 2016, a total of 42 patients of local recurrent malignant tumor of head and neck received 3D printing guide plate assist radioactive seeds implantations in in Peking University Third Hospital, and included in the retrospective study. The prescribed dose was 110 -160 Gy. All patients carried out preoperative planning design, individual guide plate production, and compared the dose distribution of postoperative plan with preoperative plan. Dose parameters include D90 , mPD, V100 , V150 , V200 , CI, EI and HI. Statistical method was paired t-test. Results A total of 423D printing individual templates were produced. The mean GTV volume of all patients was 28. 6 cm3 , and mean D90 of postoperative target area ( GTV) was 142. 6 Gy. For postoperative plans, the mean D90 , mPD, V100 , V150, V200 was 142. 6 Gy, 77. 3 Gy, 92. 48%, 68. 40%and 42. 98%, respectively, and 144. 5 Gy, 70. 2 Gy, 91. 45%, 63. 12% and 34. 74%, respectively, in preoperative plans. Except mPD, V150, V200(t= -2. 166, -2. 863, -4. 778, P<0. 05), there was no significant difference between the two groups. Conclusions 3D printing guide plate could provide good accuracy for positioning and direction. For local recurrent malignant tumor of head and neck, the actual dose distributions in postoperative validations were close to the expectations of preoperative plans which mean the improvement of accuracy in treatment.
10.Utilization rate of gold fiducial markers and reasons for abandonment in CyberKnife stereotactic body radiation therapy
Fei XU ; Fuxin GUO ; Ran PENG ; Xile ZHANG ; Hongqing ZHUANG ; Ping JIANG ; Jinghong FAN ; Weiyan LI ; Yuliang JIANG ; Zhe JI ; Haitao SUN ; Cheng CHENG ; Junjie WANG
Chinese Journal of Radiation Oncology 2018;27(3):295-298
Objective To investigate the utilization rate of gold fiducial markers and reasons for abandonment of gold fiducial markers in the CyberKnife VSI System, and to provide reference data for implantation of gold fiducial markers and radiotherapy planning. Methods From March to August,2017,a total of 47 patients had gold fiducial markers implanted or pasted. In those patients, 42 patients had gold fiducial markers implanted,including 32 receiving computed tomography(CT)-guided 3D-printing coplanar template assisted implantation, 1 receiving CT-guided 3D-printing non-coplanar template assisted implantation,1 receiving CT-guided implantation,and 8 receiving ultrasound-guided implantation. A total of 44 patients received the CyberKnife treatment, including 2 patients who failed to use gold fiducial markers and were treated with spine tracking instead and 3 patients missing the treatment for other reasons. The numbers of utilized and abandoned gold fiducial markers were recorded for calculation of the utilization and abandonment rates. The reasons for abandonment of gold fiducial markers were analyzed and classified. Results A total of 134 gold fiducial markers were implanted into or pasted to the 44 patients.In all the gold fiducial markers, 111 were utilized and 23 abandoned, yielding a utilization rate of 82.8% and an abandonment rate of 17.2%.The reasons for abandonment of gold fiducial markers included large rigidity error(26.1%), unqualified implanted fold fiducial markers(17.4%), displacement of gold fiducial markers(26.1%), and others(30.4%). Conclusions Compared with the CT-guided or ultrasound-guided implantation of gold fiducial markers, the CT-guided 3D-printing coplanar or non-coplanar template assisted implantation of gold fiducial markers requires only two puncture needles for each implantation and implants two gold fiducial markers by a single needle,which reduces the number of puncture needles,risk of puncture-induced injury,and incidence of complications after implantation. Not all the gold fiducial markers implanted by a variety of ways will be utilized. Some gold fiducial markers will be abandoned for different reasons,which should be taken into account during implantation of gold fiducial markers.

Result Analysis
Print
Save
E-mail