1.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
2.Quantitative analysis of transcranial temporal interference stimulation in rodents: A simulation study on electrode configurations.
Xiaoxi LIU ; Hongli YU ; Fushuai GOU ; Boai DU ; Pengyi LU ; Chunfang WANG
Journal of Biomedical Engineering 2025;42(2):280-287
Transcranial temporal interference stimulation (tTIS) is a novel non-invasive transcranial electrical stimulation technique that achieves deep brain stimulation through multiple electrodes applying electric fields of different frequencies. Current studies on the mechanism of tTIS effects are primarily based on rodents, but experimental outcomes are often significantly influenced by electrode configurations. To enhance the performance of tTIS within the limited cranial space of rodents, we proposed various electrode configurations for tTIS and conducted finite element simulations using a realistic mouse model. Results demonstrated that ventral-dorsal, four-channel bipolar, and two-channel configurations performed best in terms of focality, diffusion of activated brain regions, and scalp impact, respectively. Compared to traditional transcranial direct current stimulation (tDCS), these configurations improved by 94.83%, 50.59%, and 3 514.58% in the respective evaluation metrics. This study provides a reference for selecting electrode configurations in future tTIS research on rodents.
Animals
;
Transcranial Direct Current Stimulation/instrumentation*
;
Electrodes
;
Mice
;
Computer Simulation
;
Finite Element Analysis
;
Brain/physiology*
3.A simulation study of nerve fiber activation in the lumbar segment under kilohertz-frequency transcutaneously spinal cord stimulation.
Qi XU ; Xinru LI ; Zhixin LU ; Yongchao WU
Journal of Biomedical Engineering 2025;42(2):300-307
Clinical trials have demonstrated that kilohertz-frequency transcutaneous spinal cord stimulation (TSCS) can be used to facilitate the recovery of sensory-motor function for patients with spinal cord injury, whereas the neural mechanism of TSCS is still undetermined so that the choice of stimulation parameters is largely dependent on the clinical experience. In this paper, a finite element model of transcutaneous spinal cord stimulation was used to calculate the electric field distribution of human spinal cord segments T 12 to L 2, whereas the activation thresholds of spinal fibers were determined by using a double-cable neuron model. Then the variation of activation thresholds was obtained by varying the carrier waveform, the interphase delay, the modulating frequency, and the modulating pulse width. Compared with the sinusoidal carrier, the usage of square carrier could significantly reduce the activation threshold of dorsal root (DR) fibers. Moreover, the variation of activation thresholds was no more than 1 V due to the varied modulating frequency and decreases with the increased modulating pulse width. For a square carrier at 10 kHz modulated by rectangular pulse with the frequency of 50 Hz and the pulse width of 1 ms, the lowest activation thresholds of DR fibers and dorsal column fibers were 27.6 V and 55.8 V, respectively. An interphase delay of 5 μs was able to reduce the activation thresholds of the DR fibers to 20.1 V. The simulation results can lay a theoretical foundation on the selection of TSCS parameters in clinical trials.
Humans
;
Spinal Cord Stimulation/methods*
;
Nerve Fibers/physiology*
;
Finite Element Analysis
;
Spinal Cord/physiology*
;
Computer Simulation
;
Spinal Cord Injuries/physiopathology*
;
Lumbosacral Region
;
Lumbar Vertebrae
;
Transcutaneous Electric Nerve Stimulation/methods*
;
Models, Neurological
4.Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions.
Jianwu ZHANG ; WURIKAIXI AIYITI ; Gang LYU ; MAIMAIAILI YUSHAN ; Zhiqiang MA ; Chao MA
Journal of Biomedical Engineering 2025;42(2):351-358
This article aims to compare and analyze the biomechanical differences between wing-shaped titanium plates and traditional titanium plates in fixing acetabular anterior column and posterior hemi-transverse (ACPHT) fracture under multiple working conditions using the finite element method. Firstly, four sets of internal fixation models for acetabular ACPHT fractures were established, and the hip joint stress under standing, sitting, forward extension, and abduction conditions was calculated through analysis software. Then, the stress of screws and titanium plates, as well as the stress and displacement of the fracture end face, were analyzed. Research has found that when using wing-shaped titanium plates to fix acetabular ACPHT fractures, the peak stress of screws decreases under all working conditions, while the peak stress of wing-shaped titanium plates decreases under standing and sitting conditions and increases under forward and outward extension conditions. The relative displacement and mean stress of the fracture end face decrease under all working conditions, but the values are higher under forward and outward extension conditions. Wing-shaped titanium plates can reduce the probability of screw fatigue failure when fixing acetabular ACPHT fractures and can bear greater loads under forward and outward extension conditions, improving the mechanical stability of the pelvis. Moreover, the stress on the fracture end surface is more conducive to stimulating fracture healing and promoting bone tissue growth. However, premature forward and outward extension rehabilitation exercises should not be performed.
Titanium
;
Bone Plates
;
Humans
;
Acetabulum/surgery*
;
Fracture Fixation, Internal/methods*
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Bone Screws
;
Fractures, Bone/surgery*
;
Stress, Mechanical
;
Working Conditions
5.A study on the predictive model of porous hyperelastic properties of human alveolar bone based on computed tomography imaging.
Bin WU ; Mingna LI ; Fan YANG ; Le YUAN ; Yi LU ; Di JIANG ; Yang YI ; Bin YAN
Journal of Biomedical Engineering 2025;42(2):359-365
Alveolar bone reconstruction simulation is an effective means for quantifying orthodontics, but currently, it is not possible to directly obtain human alveolar bone material models for simulation. This study introduces a prediction method for the equivalent shear modulus of three-dimensional random porous materials, integrating the first-order Ogden hyperelastic model to construct a computed tomography (CT) based porous hyperelastic Ogden model (CT-PHO) for human alveolar bone. Model parameters are derived by combining results from micro-CT, nanoindentation experiments, and uniaxial compression tests. Compared to previous predictive models, the CT-PHO model shows a lower root mean square error (RMSE) under all bone density conditions. Simulation results using the CT-PHO model parameters in uniaxial compression experiments demonstrate more accurate prediction of the mechanical behavior of alveolar bone under compression. Further prediction and validation with different individual human alveolar bone samples yield accurate results, confirming the generality of the CT-PHO model. The study suggests that the CT-PHO model proposed in this paper can estimate the material properties of human alveolar bone and may eventually be used for bone reconstruction simulations to guide clinical treatment.
Humans
;
Tomography, X-Ray Computed/methods*
;
Porosity
;
Alveolar Process/physiology*
;
Bone Density
;
Computer Simulation
;
Elasticity
;
X-Ray Microtomography
;
Stress, Mechanical
;
Finite Element Analysis
;
Models, Biological
6.Modeling and finite element analysis of human trabecular meshwork outflow pathways.
Shiya BAO ; Qing SUN ; Si CHEN ; Xinyu CHEN ; Xiang PENG ; Jing ZHANG
Journal of Biomedical Engineering 2025;42(3):585-591
Glaucoma is the leading cause of irreversible blindness worldwide, with its primary risk factor arising from elevated intraocular pressure (IOP) due to an imbalance between aqueous humor production and outflow. This study aims to establish quantitative correlations among IOP, iris mechanical properties, channel microstructures, and aqueous humor dynamics through three-dimensional modeling and finite element analysis, overcoming the limitations of conventional experimental techniques in studying aqueous flow within the trabecular meshwork (TM) outflow pathway. A three-dimensional fluid-structure interaction (FSI) model incorporating the layered TM structure, Schlemm's canal (SC), iris, and other anterior segment tissues was developed based on human ocular anatomy. FSI simulations were performed to quantify the effects of IOP variations and iris Young's modulus on tissue morphology and aqueous humor dynamics parameters. The computational results demonstrated that axial iris deformation showed significant correlations with IOP and iris Young's modulus. Although elevated IOP exhibited minimal effects on hydrodynamic parameters in the anterior and posterior chambers, it markedly suppressed aqueous flow velocity in the TM region. Additionally, wall shear stress in SC and collector channels displayed high sensitivity to IOP variations. These findings reveal that the tissue mechanics-FSI mechanism modulates outflow resistance by regulating aqueous humor dynamics, offering valuable references for developing clinical therapies targeting IOP reduction in glaucoma management.
Humans
;
Trabecular Meshwork/anatomy & histology*
;
Finite Element Analysis
;
Aqueous Humor/metabolism*
;
Intraocular Pressure/physiology*
;
Glaucoma/physiopathology*
;
Iris/anatomy & histology*
;
Computer Simulation
;
Models, Biological
7.Development of a balloon sensor device for force-electrical coupling measurement of esophagus.
Peng RAN ; Ying ZHONG ; Yingbing LAI ; Lei LIU ; Yanhang ZHU ; Huantao ZHU
Journal of Biomedical Engineering 2025;42(3):610-619
To address the challenges of capturing micro-strains in detecting esophageal motility disorders and the limitations of existing high-resolution manometry and functional intraluminal imaging probes in directly measuring esophageal tissue electrical impedance, this study proposes a novel flexible balloon sensor structure that integrates a piezoelectric film assembly with a distributed impedance electrode array. Using the electrical analysis module in the finite element analysis (FEA) software, simulations of the forward problem for esophageal impedance detection were conducted to optimize the excitation source parameters, and a physical prototype was fabricated. Under a relative excitation mode with a voltage sensitivity of 2.059%, the voltage output characteristics of the impedance electrode array were analyzed during linear changes in the balloon filling volume. Based on the performance variation of the piezoelectric film assembly, 80% was selected as the optimal filling volume. Force-electric coupling tests were conducted on the balloon sensor using a pressure testing platform, revealing that both the piezoelectric film assembly inside the balloon and the impedance electrodes outside the balloon exhibited significant load differentiation characteristics as the force application point shifted. In summary, this balloon sensor facilitates the localization of force application while simultaneously analyzing esophageal tissue properties, offering a novel diagnostic approach and objective tool for esophageal disease detection.
Esophagus/physiology*
;
Electric Impedance
;
Humans
;
Finite Element Analysis
;
Manometry/methods*
;
Electrodes
;
Esophageal Motility Disorders/physiopathology*
;
Equipment Design
8.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
9.Finite element modeling and simulation study of solid-liquid biphase fiber-reinforced lumbar intervertebral disc.
Yongchang GAO ; Yantao FU ; Qingfeng CUI ; Shibin CHEN ; Peng LIU ; Xifang LIU
Journal of Biomedical Engineering 2025;42(4):799-807
The lumbar intervertebral disc exhibits a complex physiological structure with interactions between various segments, and its components are extremely complex. The material properties of different components in the lumbar intervertebral disc, especially the water content (undergoing dynamic change as influenced by age, degeneration, mechanical loading, and proteoglycan content) - critically determine its mechanical properties. When the lumbar intervertebral disc is under continuous pressure, water seeps out, and after the pressure is removed, water re-infiltrates. This dynamic fluid exchange process directly affects the mechanical properties of the lumbar intervertebral disc, while previous isotropic modeling methods have been unable to accurately reflect such solid-liquid phase behaviors. To explore the load-bearing mechanism of the lumbar intervertebral disc and establish a more realistic mechanical model of the lumbar intervertebral disc, this study developed a solid-liquid biphasic, fiber-reinforced finite element model. This model was used to simulate the four movements of the human lumbar spine in daily life, namely flexion, extension, axial rotation, and lateral bending. The fluid pressure, effective solid stress, and liquid pressure-bearing ratio of the annulus fibrosus and nucleus pulposus of different lumbar intervertebral discs were compared and analyzed under the movements. Under all the movements, the fluid pressure distribution was closer to the nucleus pulposus, while the effective solid stress distribution was more concentrated in the outer annulus fibrosus. In terms of fluid pressure, the maximum fluid pressure of the lumbar intervertebral disc during lateral bending was 1.95 MPa, significantly higher than the maximum fluid pressure under other movements. Meanwhile, the maximum effective solid stress of the lumbar intervertebral disc during flexion was 2.43 MPa, markedly higher than the maximum effective solid stress under other movements. Overall, the liquid pressure-bearing ratio under axial rotation was smaller than that under other movements. Based on the solid-liquid biphasic modeling method, this study more accurately revealed the dominant role of the liquid phase in the daily load-bearing process of the lumbar intervertebral disc and the solid-phase mechanical mechanism of the annulus fibrosus load-bearing, and more effectively predicted the solid-liquid phase co-load-bearing mechanism of the lumbar intervertebral disc in daily life.
Humans
;
Finite Element Analysis
;
Intervertebral Disc/physiology*
;
Lumbar Vertebrae/physiology*
;
Weight-Bearing/physiology*
;
Biomechanical Phenomena
;
Stress, Mechanical
;
Computer Simulation
;
Models, Biological
10.Simulation research on the influence of regular porous lattice scaffolds on bone growth.
Yutao MEN ; Lele WEI ; Baibing HU ; Pujun HAO ; Chunqiu ZHANG
Journal of Biomedical Engineering 2025;42(4):808-816
To assess the implantation effectiveness of porous scaffolds, it is essential to consider not only their mechanical properties but also their biological performance. Given the high cost, long duration and low reproducibility of biological experiments, simulation studies as a virtual alternative, have become a widely adopted and efficient evaluation method. In this study, based on the secondary development environment of finite element analysis software, the strain energy density growth criterion for bone tissue was introduced to simulate and analyze the cell proliferation-promoting effects of four different lattice porous scaffolds under cyclic compressive loading. The biological performance of these scaffolds was evaluated accordingly. The computational results indicated that in the early stages of bone growth, the differences in bone tissue formation among the scaffold groups were not significant. However, as bone growth progressed, the scaffold with a porosity of 70% and a pore size of 900 μm demonstrated markedly superior bone formation compared to other porosity groups and pore size groups. These results suggested that the scaffold with a porosity of 70% and a pore size of 900 μm was most conducive to bone tissue growth and could be regarded as the optimal structural parameter for bone repair scaffold. In conclusion, this study used a visualized simulation approach to pre-evaluate the osteogenic potential of porous scaffolds, aiming to provide reliable data support for the optimized design and clinical application of implantable scaffolds.
Tissue Scaffolds/chemistry*
;
Porosity
;
Finite Element Analysis
;
Tissue Engineering/methods*
;
Computer Simulation
;
Bone Development
;
Osteogenesis
;
Humans
;
Cell Proliferation

Result Analysis