1.Double anatomical plate assisted reconstruction of a stable triangle for the treatment of chronic AO/OTA type C3 fractures of the distal humerus
Shangzhi LI ; Jingzhi YANG ; Jiaxi LIU ; Shijie KANG ; Tao JIANG ; Dongsheng HUANG ; Tao LIU ; Fuxin LYU ; Feilong BAO
Chinese Journal of Orthopaedics 2025;45(13):856-863
Objective:To investigate the therapeutic effectiveness of double-anatomical plate-assisted reconstruction of a stable triangle in the treatment of chronic distal humerus fractures.Methods:A retrospective analysis was performed on the medical records of 10 patients with distal humerus fracture treated with double plate assisted reconstruction of a stable triangle from August 2021 to December 2024. All patients were followed up for more than 6 months. The cohort included 9 males and 1 female, with a mean age of 54.75±15.15 years (range, 31-73 years). Causes of injury: 4 cases of slip, 2 cases of high-energy fall, 3 cases of traffic accident, and 1 case of crush injury. According to the AO/OTA classification, all fractures were type C3, including 4 cases of C3.3 and 6 cases of C3.2. The operation duration, intraoperative blood loss, and length of hospital stay were recorded. Follow-up evaluations were conducted at 1, 3, and 6 months postoperatively and at the final follow-up. Radiographs were obtained to assess fracture reduction, healing, and implant positioning. Functional outcomes of the elbow were assessed using carrying angle, humeral condyle anteversion angle, modified trochleocapitellar index (mTCI), range of motion (ROM), visual analogue scale (VAS) for pain, Mayo elbow performance score (MEPS), and complication rates.Results:All 10 patients successfully completed the operation, with an average operation time of 221.75±48.73 min (range, 165-310 min), an average intraoperative blood loss of 462.50±215.05 ml (range 150-800 ml). 4 patients received blood transfusion. The average hospital stay was 10.75±2.55 d (range 6-14 d). The average carrying angle of 171.50°±5.37° (range 165°-179°) and the anterior angle of humeral condyle 39.75°±3.96° (range 34°-45°) were all within the standard range. At least one index in the mTCI was within the optimal range at the last follow-up. All patients were followed up with an average follow-up of 10.75±5.73 months (range 6-22 months). All 10 patients were healed after surgery with an average healing time of 4.75±2.05 months (range 3-9 months). At the final follow-up, the average elbow ROM was 93.75°±25.88° (range, 50°-115°), internal rotation was 83.13°±9.61° (range, 60°-90°), and external rotation was 88.13°±3.72° (range, 80°-90°). The mean VAS score was 0.63±0.92 (range, 0-2), and the average MEPS was 88.75±11.57 (range, 70-100), with 4 excellent, 4 good, and 2 fair outcomes, an excellent and good rate of 80%. Complications included one case of periarticular osteophyte formation, one case of transient ulnar nerve numbness that improved with conservative treatment, and three cases of occasional mild pain following increased activity. Conclusion Double-anatomical plate-assisted reconstruction of a stable triangle provides effective and stable fixation for chronic AO/OTA C3 distal humerus fractures. The short-term postoperative outcomes are satisfactory, with good functional recovery and a low complication rate.Conclusions:Double-anatomical plate-assisted reconstruction of a stable triangle provides effective and stable fixation for chronic AO/OTA C3 distal humerus fractures. The short-term postoperative outcomes are satisfactory, with good functional recovery and a low complication rate.
2.Prediction of major adverse cardiovascular events after acute type A aortic dissection combined with coronary malperfusion by machine learning-based interpretable models
Hao ZHANG ; Bo JIA ; Zuo ZHANG ; Huanyu QIAO ; Bo YANG ; Jing YANG ; Feilong HEI ; Xiaotong HOU ; Junming ZHU ; Yongmin LIU
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(3):129-135
Objective:To explore and model risk factors in patients with major adverse cardiovascular events (MACEs) after acute type A aortic dissection (ATAAD), and to develop and validate a personalized machine learning model to assess risk factors and predict MACEs in these patients.Methods:Clinical data of patients who attended Beijing Anzhen Hospital and underwent surgical treatment for ATAAD from January 2018 to October 2022 were retrospectively analyzed. Using MACEs as the endpoint, 70% of these patients were randomly divided into the training set and the remaining 30% into the validation set. LASSO regression was applied to explore key clinical variables in the training set. The optimal predictive model was selected from nine machine learning algorithms based on area under the curve. And Shapley Additive explanations was used to elucidate the predictive model. Results:Of the 481 patients included in this study, 135 (35.6%) patients experienced an endpoint event. By combining the results of the training and validation sets, when assessing the validity of the single model with the highest predictive accuracy for the outcome, it was shown that the logistic model (0.774, 95% CI: 0.717-0.830) was the most effective in the combined effect and had a high model accuracy (0.743, 95% CI: 0.720-0.766). According to the results of the LASSO, the factors most associated with postoperative MACEs were history of cerebrovascular disease, coronary artery involvement, shock status on admission to the operating room, FDP, PLT, CPB, ascending aortic clamping, and age. Conclusion:In this study, nine machine learning models were developed to predict the occurrence of postoperative MACEs in patients with acute type A aortic dissection. The logistic model performed significantly better compared to other algorithms. Our study successfully predicted postoperative MACES and identified the factors most associated with MACEs.
3.Effects of a virtual reality rehabilitation support system on discharge readiness among caregivers of post-laryngectomy patients
Li LI ; Yongling LIU ; Yang ZHANG ; Meng LIAN ; Yuehong WANG ; Shunli LU ; Chen YANG ; Tingting LI ; Yiran HE ; Xiaoting JIN ; Feilong XU ; Zirong TIAN
Chinese Journal of Nursing 2025;60(20):2451-2457
Objective To develop a virtual reality rehabilitation support system and evaluate its effects on improving discharge readiness in caregivers of laryngectomy patients.Methods The system is equipped with a virtual reality-based home nursing skills guidance module for post-laryngectomy patients and an evidence-based artificial intelligence Q&A module.A convenience sampling method was adopted to select 64 caregivers of patients who underwent laryngectomy for the first time in the otorhinolaryngology head and neck surgery department of a tertiary A hospital in Beijing from July 2024 to January 2025 for a systematic study on application effects.To avoid cross-contamination between an experimental group and a control group,ward-based grouping was applied.A coin toss was used to assign Ward 1 to an experimental group and Ward 2 to a control group,with 32 cases in each group.The experimental group received discharge guidance based on the virtual reality technology,while the control group was provided with conventional verbal and written discharge instructions.The readiness for hospital discharge and the quality of discharge teaching scores of caregivers were compared between the 2 groups after the intervention.Results No sample detachment.After the intervention,the patient caregivers in the experimental group scored significantly higher than those in the control group in terms of discharge readiness and quality of discharge guidance,with a statistically significant difference(P<0.001).Conclusion This study developed the virtual reality rehabilitation system for laryngeal cancer patients demonstrated good feasibility and effectiveness.The application of this system for discharge education significantly improved discharge readiness of caregivers and quality of discharge guidance for post-laryngectomy patients.It also helped with the optimization of health education models,enhancement of nursing resource utilization efficiency,and improvement of transitional care.
4.Application effect of a non-contact sleep monitoring mattress based on body movement characteristics during sleep
Yanchun ZHANG ; Yan LIU ; Rui WANG ; Feilong WANG ; Yue ZHAO ; Fei LI ; Tunan CHEN ; Jishu XIAN
Journal of Army Medical University 2025;47(4):326-334
Objective To verify the accuracy of a Non-Contact Sleep Monitoring Mattress(NCSMM)based on body movement during sleep in assessing sleep quality of patients before neurosurgery in order to provide a more portable and efficient assessment tool for clinical staff.Methods A single-arm trial was conducted on 114 inpatients admitted in our department selected with convenience sampling.Sleep quality data of 1 night were collected through 5 sleep quality assessment tools,including NCSMM,polysomnography(PSG),Patient-Reported Outcome Measurement Information System(PROMIS)Sleep Disturbance scale,Richards-Campbell Sleep Scale(RCSQ),and a wearable device(smart watch for body movements and sleep quality monitoring).The sleep efficiency(≤85%)obtained by PSG was used as the diagnostic standard for sleep disorders.The area under the receiver operating characteristic curve(AUC),sensitivity,specificity,positive predictive value,negative predictive value,and Youden index were calculated for the other 4 tools to evaluate and compare their diagnostic effectiveness.Results The AUC value for NCSMM,PROMIS,RCSQ and smart watch was 0.788(95%CI:0.687~0.888,P<0.001),0.664(95%CI:0.543~0.784,P=0.02),0.723(95%CI:0.600~0.846,P=0.001)and 0.750(95%CI:0.654~0.846,P<0.001),respectively.The diagnostic accuracy rate was 0.774,0.559,0.742 and 0.602,with corresponding Youden index value of 0.488,0.321,0.456,and 0.459.NCSMM demonstrated the best AUC value,sensitivity and Youden index when compared with the other 3 tools.Conclusion NCSMM shows high accuracy in assessing sleep quality in pre-neurosurgery inpatients,and it is a viable portable and efficient assessment tool in clinical practice.
5.Association of sitting time with all-cause mortality and cardiovascular disease in the Chinese population
Lei LAN ; Xinyue LANG ; Feilong CHEN ; Hui WANG ; Guomin HE ; Wei LI ; Zhiguang LIU ; On behalf of PURE-China investigators
Basic & Clinical Medicine 2025;45(11):1438-1443
Objective To explore potential association between sedentary time and the risk of all-cause mortality and cardiovascular disease(CVD)in Chinese population using data from the Prospective Urban Rural Epidemiology(PURE-China)cohort study.Methods Baseline data were collected,from 2022 standardized questionnaires and physical examinations,with follow-up until August 31,2022.The primary endpoints were all-cause mortality and cardiovascular events(non-fatal myocardial infarction,stroke or heart failure).Multivariable Cox shared frailty model was used to analyze the association between sedentary time and the risks of all-cause mortality and CVD in the target population,and to compare differences across subgroups based on gender,age and geographic location.Results A total of 47 931 participants were recruited,and 43 367 were included in the final analysis.Over a me-dian follow-up of 11.9±3.0 years,2 277 participants experienced all-cause mortality,3 551 experienced cardiovas-cular events.The Cox model indicated that,compared to individuals with less than 4 h of sedentary time per day,those with 6-8 h had a 23%increased in risk of all-cause mortality(HR=1.23,95%CI:1.06-1.44)and an 18%increased risk of CVD(HR=1.18,95%CI:1.04-1.33).For individuals with more than 8 h of sedentary time,the risk increased by 50%for all-cause mortality(HR=1.50,95%CI:1.16-1.94)and 44%for CVD(HR=1.44,95%CI:1.16-1.79).These associations were more pronounced in men and individuals aged 50 years and older.Conclusions Sedentary behavior is associated with an increased risk of all-cause mortality and cardiovascular disease in Chinese population,especially in the population with sedentary time of 6 hrs or more per day.Reducing sedentary time and increasing physical activity is an important strategy to mitigate the disease burden of cardiovascular disease and premature death.
6.The diagnostic value of CT imaging evaluation for lymph node metastasis in gallbladder cancer and its correlation with prognosis
Sen YANG ; Shuai YAN ; Feilong TAN ; Yihan WANG ; Bingbing LIU ; Xueliang YUE ; Hongshan LIU
Chinese Journal of General Surgery 2025;40(4):290-294
Objective:To assess the accuracy of preoperative enhanced CT in evaluating the degree of lymph node metastasis in gallbladder cancer.Methods:A retrospective analysis was performed on the enhanced CT imaging data of 124 gallbladder cancer patients who underwent surgical treatment at Henan Provincial People's Hospital from Jan 2017 to Dec 2018. Imaging staging was used to classify lymph node metastasis. Pathological and imaging data of 70 patients with confirmed postoperative lymph node pathology were compared to evaluate the accuracy of imaging methods in detecting lymph node involvement.Results:Lymph node metastasis in the 124 surgical patients was categorized into three groups using imaging evaluation methods. The overall accuracy of determining lymph node positivity and negativity was 63%, with a sensitivity of 64% and specificity of 62%. The accuracy of detecting lymph node metastasis in gallbladder cancer was higher when lymph node fusion and internal necrosis were observed. The overall survival rate differed significantly among gallbladder cancer patients at different lymph node imaging stages ( P<0.05). Conclusion:CT imaging evaluation has diagnostic value for lymph node metastasis in gallbladder cancer and has a certain predictive effect on the prognosis of patients.
7.Coenzyme Q10 regulates apoptosis of TM3 cells induced by bisphenol A through au-tophagy
Wenzhe YANG ; Tong ZHAO ; Feilong PAN ; Jinhao WANG ; Fangfang CHEN ; Wenqi SHAO ; Shirui WANG ; Shuchen ZHAO ; Kexiang LIU ; Lijia ZHAO
Chinese Journal of Veterinary Science 2025;45(1):91-99
This study aims to investigate whether the dietary supplement coenzyme Q10(CoQ10)alleviates bisphenol A(BPA)-induced mouse Leydig cell line(TM3)damage through autophagy pathway.Cell activity was measured by CCK-8 assay when treated with different concentrations of BPA for 24 h.TM3 cells were then divided into 5 groups:CON group,BPA group,Torin2 group,CQ group and BPA+CoQ10 group,with three repeats in each group.The morphology of TM3 cells were observed under inverted light microscope.Western blot was used to determine the protein ex-pression of p62 and LC3-Ⅰ/Ⅱ.The autophagy level of TM3 cells was detected by MDC cell auto-phagy staining,the mRNA expression levels of Atg7,Beclin 1,p62 and Atg5 genes were deter-mined by RT-qPCR,and the apoptosis rate of TM3 cells was detected by flow cytometry.The results showed that compared with 0 μmol/L BPA treatment group,the viability of TM3 cells de-creased significantly after 24 h treatment with 60 μmol/L BPA(P<0.01).Compared with CON group,the number of TM3 cells markedly reduced in the BPA-treated group,the expression of au-tophagy-related proteins(p62,LC3-Ⅱ)significantly increased(P<0.01),comparable to the CQ group.The MDC fluorescence intensity dramatically enhanced(P<0.01),the mRNA expression levels of autophagy-related genes(Atg7,Beclin1,p62,Atg5)significantly elevated(P<0.01),and the apoptosis rate significantly increased(P<0.01).Compared with BPA group,the expression levels of autophagy-related genes Atg7 and Beclin1 mRNA(P<0.05),p 62 and Atg5 mRNA(P<0.01)in TM3 cells treated with BPA+CoQ10 significantly decreased.Moreover,the expres-sion levels of autophagy-related protein p62(P<0.01)and LC3-Ⅱ(P<0.05),MDC fluorescence intensity(P<0.05)and apoptosis rate(P<0.01)also markedly reduced.In conclusion,CoQ10 could subsequently reduce the apoptosis of TM3 cells by improving the abnormal autophagy flux induced by BPA.
8.Finite element analysis of a novel lumbar facet joint fusion device
Feilong SUN ; Haiyang QIU ; Yufei JI ; Yipeng YANG ; Daming LIU ; Longchao WANG ; Fei WANG ; Wei LEI ; Yang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(15):3081-3088
BACKGROUND:Facet joint osteoarthritis is acknowledged as a significant contributor to lower back pain in the geriatric population.The advent of an innovative spinal facet joint fusion device presents a therapeutic option for intervening during the initial stages of facet joint osteoarthritis,and significantly reduces the incidence of a series of complications caused by poor early conservative treatment and late surgical treatment.However,its effect on the biomechanics of the lumbar spine is unknown.OBJECTIVE:To investigate the biomechanical disparities between the novel lumbar zygapophyseal joint fusion device and traditional fusion devices.METHODS:A comprehensive three-dimensional finite element model of the L3-S1 lumbar spine was established and validated.Based on this intact model,three groups of surgical models were constructed:a bilateral pedicle screw fixation model,a bilateral novel facet joint fusion fixation model,and a bilateral facet screw fixation model,with the surgical segment designated as L4-5.Under a load of 500 N,a torque of 7.5 Nm was applied to all lumbar models to calculate the range of motion,displacement values,and intervertebral disc stress values at the L4-5 segment;stress values at the L3-4 and L5-S1 segments were also measured.RESULTS AND CONCLUSION:(1)Compared with the intact model,the range of motion at the L4-5 segment was reduced in all surgical models.(2)The novel device exhibited the smallest range of motion at the L4-5 segment under left and right rotational conditions;the greatest range of motion at the L4-5 segment under extension conditions;and a greater range of motion under other conditions than the bilateral pedicle screw fixation model.(3)The novel device demonstrated the smallest displacement values at the L4-5 segment under left and right rotational conditions;under other conditions,the displacement values at the L4-5 segment were greater than those in the bilateral pedicle screw fixation model.(4)In terms of stress distribution at the L4-5 segment,the novel device consistently exhibited the smallest values across all conditions.(5)For the L3-4 segment,the novel device showed the greatest stress values under extension and left and right rotational conditions,while under other conditions,the values were lower than those in the bilateral pedicle screw fixation model.(6)Compared with pedicle screw fixation,the novel device produced smaller stress values at the L5-S1 segment.(7)This study indicates that,compared with pedicle screw fixation,the novel device impacts the biomechanics of the lumbar spine by fusing the facet joints.It provides stability while preserving the range of motion at the surgical segment and reduces stress on the intervertebral discs of the surgical and adjacent segments,thereby potentially delaying disc degeneration.This suggests that the novel device can achieve biomechanical effects similar to those of pedicle screw fixation in theory.
9.Efficacy and prognosis of preoperative treatment based on arterial infusion chemotherapy in patients with advanced gastric cancer: a real-world study
Xiaosong XIANG ; Feilong GUO ; Yu SU ; Long MA ; Donghong SHI ; Leilei LIU ; Guoli LI
Chinese Journal of Oncology 2025;47(2):183-192
Objective:To explore the efficacy and prognosis of preoperative treatment based on arterial infusion chemotherapy (PTAC) in patients with advanced gastric cancer.Methods:Clinical and follow-up data of 821 patients with advanced gastric cancer who received PTAC treatment at the General Hospital of the Eastern Theater Command of the People's Liberation Army from January 2001 to January 2021 were collected. According to the treatment regimen, patients were divided into the FLEEOX group (89 cases), the XEEOX group (196 cases), the SEEOX group (406 cases), and the SEEOX+PD-1 group (130 cases). The primary endpoint was the 3-year progression-free survival rate. Secondary endpoints included the 3-year overall survival rate, objective response rate, radical resection rate, major pathological response rate, and incidence of treatment associated adverse events.Results:After PTAC treatment, the objective response rate was 74.9% (615/821). A total of 671 patients underwent radical surgery, with a radical resection rate of 81.7% and an R0 resection rate of 70.2% (576/821). The pathological complete response rate was 16.7% (112/671), and the major pathological response rate was 32.2% (216/671). With an average follow-up of 27.7 months, the 3-year progression-free survival rate was 52.2%, and the 3-year overall survival rate was 55.8%. The 3-year progression-free survival rate of patients in the SEEOX+PD-1 group was 66.9%, the objective response rate was 83.8% (109/130), the major pathological response rate was 45.3% (53/117), and the radical resection rate was 90.0% (117/130), all of which were better than those in the XEEOX and SEEOX groups (all P<0.05). However, during the treatment period, three patients in the SEEOX+PD-1 group died from immune-related adverse events. Conclusion:PTAC treatment is an effective preoperative treatment method for advanced gastric cancer, and is expected to further improve the treatment effect when combined with immunotherapy such as PD-1 monoclonal antibodies.
10.Double anatomical plate assisted reconstruction of a stable triangle for the treatment of chronic AO/OTA type C3 fractures of the distal humerus
Shangzhi LI ; Jingzhi YANG ; Jiaxi LIU ; Shijie KANG ; Tao JIANG ; Dongsheng HUANG ; Tao LIU ; Fuxin LYU ; Feilong BAO
Chinese Journal of Orthopaedics 2025;45(13):856-863
Objective:To investigate the therapeutic effectiveness of double-anatomical plate-assisted reconstruction of a stable triangle in the treatment of chronic distal humerus fractures.Methods:A retrospective analysis was performed on the medical records of 10 patients with distal humerus fracture treated with double plate assisted reconstruction of a stable triangle from August 2021 to December 2024. All patients were followed up for more than 6 months. The cohort included 9 males and 1 female, with a mean age of 54.75±15.15 years (range, 31-73 years). Causes of injury: 4 cases of slip, 2 cases of high-energy fall, 3 cases of traffic accident, and 1 case of crush injury. According to the AO/OTA classification, all fractures were type C3, including 4 cases of C3.3 and 6 cases of C3.2. The operation duration, intraoperative blood loss, and length of hospital stay were recorded. Follow-up evaluations were conducted at 1, 3, and 6 months postoperatively and at the final follow-up. Radiographs were obtained to assess fracture reduction, healing, and implant positioning. Functional outcomes of the elbow were assessed using carrying angle, humeral condyle anteversion angle, modified trochleocapitellar index (mTCI), range of motion (ROM), visual analogue scale (VAS) for pain, Mayo elbow performance score (MEPS), and complication rates.Results:All 10 patients successfully completed the operation, with an average operation time of 221.75±48.73 min (range, 165-310 min), an average intraoperative blood loss of 462.50±215.05 ml (range 150-800 ml). 4 patients received blood transfusion. The average hospital stay was 10.75±2.55 d (range 6-14 d). The average carrying angle of 171.50°±5.37° (range 165°-179°) and the anterior angle of humeral condyle 39.75°±3.96° (range 34°-45°) were all within the standard range. At least one index in the mTCI was within the optimal range at the last follow-up. All patients were followed up with an average follow-up of 10.75±5.73 months (range 6-22 months). All 10 patients were healed after surgery with an average healing time of 4.75±2.05 months (range 3-9 months). At the final follow-up, the average elbow ROM was 93.75°±25.88° (range, 50°-115°), internal rotation was 83.13°±9.61° (range, 60°-90°), and external rotation was 88.13°±3.72° (range, 80°-90°). The mean VAS score was 0.63±0.92 (range, 0-2), and the average MEPS was 88.75±11.57 (range, 70-100), with 4 excellent, 4 good, and 2 fair outcomes, an excellent and good rate of 80%. Complications included one case of periarticular osteophyte formation, one case of transient ulnar nerve numbness that improved with conservative treatment, and three cases of occasional mild pain following increased activity. Conclusion Double-anatomical plate-assisted reconstruction of a stable triangle provides effective and stable fixation for chronic AO/OTA C3 distal humerus fractures. The short-term postoperative outcomes are satisfactory, with good functional recovery and a low complication rate.Conclusions:Double-anatomical plate-assisted reconstruction of a stable triangle provides effective and stable fixation for chronic AO/OTA C3 distal humerus fractures. The short-term postoperative outcomes are satisfactory, with good functional recovery and a low complication rate.

Result Analysis
Print
Save
E-mail