1.Multi-modal imaging technology combined with evaluation of knee joint occult injury: comparative analysis of MSCT, DR and MRI fat suppression sequences
Yuangang ZHANG ; Yalong YANG ; Fei ZHAO ; Xiaojun KANG
Chinese Journal of Radiological Health 2026;35(2):221-228
Objective To evaluate the consistency of multi-slice spiral CT (MSCT), Digital Radiography (DR) and fat-suppression MRI in detecting occult knee joint injury. Method Clinical data from 150 patients with suspected occult knee injuries who presented to the Department of imaging at the General Hospital of Ordnance Industry between August 2022 and August 2023 were retrospectively reviewed. All patients underwent MSCT, DR, and fat-suppression MRI for diagnostic evaluation. Arthroscopic or surgical findings served as the gold standard. We analyzed and compared the detection rates of specific types of occult knee injuries (ligament, meniscus, occult fracture, etc.) across the three modalities, as well as their ability to assess the degree of collapse and horizontal displacement in patients with knee fractures, and their overall diagnostic performance. Result According to the gold standard, among the 150 patients with suspected occult knee injury, 103 tested positive and 47 negative. Statistically significant differences were observed among MSCT, DR, and fat-suppression MRI in detecting occult fractures(P<0.05). The detection rates ranked in descending order asfollows: fat-suppression MRI>MSCT>DR. However, no significant difference were found in the detection rates of joint effusion and patellar cartilage injuries among the three techniques (P>0.05). Statistically differences were also note among the three techniques in detecting the degree of collapse and horizontal displacement in patients with knee fractures (P<0.05). Specifically fat-suppression MRI identified a higher proportion of grade 1 and 2 lesions than both MSCT and DR. Statistically significant differences were observed among the three techniques in diagnostic sensitivity and accuracy for occult knee injuries (P<0.05). Fat-suppression MRI demonstrated superior sensitivity (99.03%) and accuracy (96.67%) compared with MSCT (75.73%, 79.33%) and DR (61.17%, 68.00%). However, no significant difference was found in diagnostic specificity among the three techniques (P>0.05). Conclusion Compared with MSCT and DR, fat-suppression MRI offers higher diagnostic sensitivity and accuracy for occult knee injuries, particularly in identifying ligament injuries, meniscus injuries, and occult fractures.
2.Source and carcinogenesis risk assessment of PM2.5-bound polycyclic aromatic hydrocarbons in Harbin, China
Zhen KANG ; Yang LIU ; Rao FU ; Xiaobo LIU ; Qianqi HONG ; Fei YAN
Journal of Public Health and Preventive Medicine 2026;37(4):6-10
Objective To analyze the pollution characteristics of PM2.5-bound polycyclic aromatic hydrocarbons (PAHs) during the non-heating period, heating period, and haze period in Harbin, and infer their possible sources, and to evaluate their impact on population carcinogenesis. Methods From 2020 to 2022, sampling points were set up in different districts of Harbin. PM2.5 samples were regularly collected every month to analyze the contents of 10 types of PM2.5-bound 4-6 rings PAHs. The pollution characteristics of PAHs were analyzed during different monitoring periods (non-heating period, heating period, and haze period). The excess carcinogenesis risks of PM2.5-bound PAHs were assessed according to the Technical Specifications for Health Risk Assessment of Ambient Air Pollution and the U. S. Environmental Protection Agency (US EPA) risk assessment method. The characteristic ratio method and the positive matrix factorization (PMF) model were used to infer the sources of PAHs. Results The median mass concentrations of ambient PM2.5-bound 4-6 rings PAHs (ΣPAHs) during the non-heating period, heating period, and haze period were 6.44 ng/m3, 37.85 ng/m3, and 106.79 ng/m3, respectively. During the heating season and haze period, the concentrations of benzo[a]anthracene, benzo[k]fluoranthene, pyrene and fluoranthene were relatively high. The excess carcinogenic risks for ASF>16, ASF2-16 and ASF<2 caused by exposure to PM2.5-bound 4-6rings PAHs during the heating season were 2.34×10-6, 1.82×10-6, and 0.88×10-6, respectively, while the excess carcinogenic risks for the whole population during the heating season and haze period were 5.05×10-6 and 1.75×10-6, respectively. The results of the two source methods showed that the main characteristic elements during the heating season were fluoranthene, pyrene, benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[a]pyrene. According to the emission source standards, it was determined that the sources were mainly coal and biomass combustion, accompanied by traffic source emissions. Conclusion In Harbin, the PM2.5-bound 4-6 rings PAHs during the haze period is significantly higher than that during the heating period. The pollution is mainly from coal combustion emissions, accompanied by continuous traffic source pollution. The exposure to PAHs during the heating period poses a potential carcinogenic risk to the population.
3.Multi-modal imaging technology combined with evaluation of knee joint occult injury: comparative analysis of MSCT, DR and MRI fat suppression sequences
Yuangang ZHANG ; Yalong YANG ; Fei ZHAO ; Xiaojun KANG
Chinese Journal of Radiological Health 2026;35(2):221-228
Objective To evaluate the consistency of multi-slice spiral CT (MSCT), Digital Radiography (DR) and fat-suppression MRI in detecting occult knee joint injury. Method Clinical data from 150 patients with suspected occult knee injuries who presented to the Department of imaging at the General Hospital of Ordnance Industry between August 2022 and August 2023 were retrospectively reviewed. All patients underwent MSCT, DR, and fat-suppression MRI for diagnostic evaluation. Arthroscopic or surgical findings served as the gold standard. We analyzed and compared the detection rates of specific types of occult knee injuries (ligament, meniscus, occult fracture, etc.) across the three modalities, as well as their ability to assess the degree of collapse and horizontal displacement in patients with knee fractures, and their overall diagnostic performance. Result According to the gold standard, among the 150 patients with suspected occult knee injury, 103 tested positive and 47 negative. Statistically significant differences were observed among MSCT, DR, and fat-suppression MRI in detecting occult fractures(P<0.05). The detection rates ranked in descending order asfollows: fat-suppression MRI>MSCT>DR. However, no significant difference were found in the detection rates of joint effusion and patellar cartilage injuries among the three techniques (P>0.05). Statistically differences were also note among the three techniques in detecting the degree of collapse and horizontal displacement in patients with knee fractures (P<0.05). Specifically fat-suppression MRI identified a higher proportion of grade 1 and 2 lesions than both MSCT and DR. Statistically significant differences were observed among the three techniques in diagnostic sensitivity and accuracy for occult knee injuries (P<0.05). Fat-suppression MRI demonstrated superior sensitivity (99.03%) and accuracy (96.67%) compared with MSCT (75.73%, 79.33%) and DR (61.17%, 68.00%). However, no significant difference was found in diagnostic specificity among the three techniques (P>0.05). Conclusion Compared with MSCT and DR, fat-suppression MRI offers higher diagnostic sensitivity and accuracy for occult knee injuries, particularly in identifying ligament injuries, meniscus injuries, and occult fractures.
4.Multi-modal imaging technology combined with evaluation of knee joint occult injury: comparative analysis of MSCT, DR and MRI fat suppression sequences
Yuangang ZHANG ; Yalong YANG ; Fei ZHAO ; Xiaojun KANG
Chinese Journal of Radiological Health 2026;35(2):221-228
Objective To evaluate the consistency of multi-slice spiral CT (MSCT), Digital Radiography (DR) and fat-suppression MRI in detecting occult knee joint injury. Method Clinical data from 150 patients with suspected occult knee injuries who presented to the Department of imaging at the General Hospital of Ordnance Industry between August 2022 and August 2023 were retrospectively reviewed. All patients underwent MSCT, DR, and fat-suppression MRI for diagnostic evaluation. Arthroscopic or surgical findings served as the gold standard. We analyzed and compared the detection rates of specific types of occult knee injuries (ligament, meniscus, occult fracture, etc.) across the three modalities, as well as their ability to assess the degree of collapse and horizontal displacement in patients with knee fractures, and their overall diagnostic performance. Result According to the gold standard, among the 150 patients with suspected occult knee injury, 103 tested positive and 47 negative. Statistically significant differences were observed among MSCT, DR, and fat-suppression MRI in detecting occult fractures(P<0.05). The detection rates ranked in descending order asfollows: fat-suppression MRI>MSCT>DR. However, no significant difference were found in the detection rates of joint effusion and patellar cartilage injuries among the three techniques (P>0.05). Statistically differences were also note among the three techniques in detecting the degree of collapse and horizontal displacement in patients with knee fractures (P<0.05). Specifically fat-suppression MRI identified a higher proportion of grade 1 and 2 lesions than both MSCT and DR. Statistically significant differences were observed among the three techniques in diagnostic sensitivity and accuracy for occult knee injuries (P<0.05). Fat-suppression MRI demonstrated superior sensitivity (99.03%) and accuracy (96.67%) compared with MSCT (75.73%, 79.33%) and DR (61.17%, 68.00%). However, no significant difference was found in diagnostic specificity among the three techniques (P>0.05). Conclusion Compared with MSCT and DR, fat-suppression MRI offers higher diagnostic sensitivity and accuracy for occult knee injuries, particularly in identifying ligament injuries, meniscus injuries, and occult fractures.
5.Correlation Between the Spinopelvic Parameters and Morphological Characteristics of Pedicle-Facet Joints in Different Lumbar Spondylolisthesis
Baoqiang HE ; Yebo LENG ; Shicai XU ; Yang LI ; Jiajun ZHOU ; Min KANG ; Yehui LIAO ; Minghao TIAN ; Qiang TANG ; Fei MA ; Qing WANG ; Chao TANG ; Dejun ZHONG
Neurospine 2025;22(1):231-242
Objective:
Based on spinopelvic parameters and biomechanical principles, the pedicle-facet joint (PFJ) morphological characteristics of isthmic and degenerative spondylolisthesis were analyzed, and the mechanism of their onset and progression was discussed.
Methods:
This retrospective cross-sectional study included 194 patients with L5 spondylolysis or L5–S1 low-grade isthmic spondylolisthesis (IS group), 172 patients with L4–5 degenerative spondylolisthesis (DS group), and 366 patients with nonlumbar spondylolysis (NL group). The spinopelvic parameters and PFJ morphological parameters of the patients were measured, the differences in these parameters among and within the 3 groups were compared, and the correlations were analyzed.
Results:
Sacral slope (SS) and lumbar lordosis (LL) were the highest in the IS group, the second highest in the DS group, and the lowest in the NL group. Among the 3 groups, the L4 facet joint angle (FJA) was the largest in the IS group, the second largest in the NL group, and the smallest in the DS group. The L4 pedicle-facet joint angle (PFA) was the largest in the DS group, the second largest in the IS group, and the smallest in the NL group. Pearson correlation analysis showed that within each group, SS and LL were negatively correlated with FJA and positively correlated with PFA.
Conclusion
This study found a correlation between the PFJ morphological characteristics of patients with lumbar spondylolisthesis and spinopelvic parameters, suggesting that the morphological characteristics of PFJs may be caused by varying stresses under different spinopelvic morphologies.
6.Correlation Between the Spinopelvic Parameters and Morphological Characteristics of Pedicle-Facet Joints in Different Lumbar Spondylolisthesis
Baoqiang HE ; Yebo LENG ; Shicai XU ; Yang LI ; Jiajun ZHOU ; Min KANG ; Yehui LIAO ; Minghao TIAN ; Qiang TANG ; Fei MA ; Qing WANG ; Chao TANG ; Dejun ZHONG
Neurospine 2025;22(1):231-242
Objective:
Based on spinopelvic parameters and biomechanical principles, the pedicle-facet joint (PFJ) morphological characteristics of isthmic and degenerative spondylolisthesis were analyzed, and the mechanism of their onset and progression was discussed.
Methods:
This retrospective cross-sectional study included 194 patients with L5 spondylolysis or L5–S1 low-grade isthmic spondylolisthesis (IS group), 172 patients with L4–5 degenerative spondylolisthesis (DS group), and 366 patients with nonlumbar spondylolysis (NL group). The spinopelvic parameters and PFJ morphological parameters of the patients were measured, the differences in these parameters among and within the 3 groups were compared, and the correlations were analyzed.
Results:
Sacral slope (SS) and lumbar lordosis (LL) were the highest in the IS group, the second highest in the DS group, and the lowest in the NL group. Among the 3 groups, the L4 facet joint angle (FJA) was the largest in the IS group, the second largest in the NL group, and the smallest in the DS group. The L4 pedicle-facet joint angle (PFA) was the largest in the DS group, the second largest in the IS group, and the smallest in the NL group. Pearson correlation analysis showed that within each group, SS and LL were negatively correlated with FJA and positively correlated with PFA.
Conclusion
This study found a correlation between the PFJ morphological characteristics of patients with lumbar spondylolisthesis and spinopelvic parameters, suggesting that the morphological characteristics of PFJs may be caused by varying stresses under different spinopelvic morphologies.
7.Efficacy and safety of Lutai Danshen Baishao granules for treating female melasma: A randomized, double-blind, placebo-controlled trial
Meiyu Lyu ; Yi Yang ; Jinlian Liu ; Wenting Fei ; Min Fu ; Yunting Hong ; Hongguo Rong ; Chun Wang ; Linyuan Wang ; Jianjun Zhang
Journal of Traditional Chinese Medical Sciences 2025;2025(1):71-78
Objective:
To investigate the potential efficacy and safety of Lutai Danshen Baishao granules (LDBG) for treating female melasma associated with kidney deficiency and blood stasis patterns.
Methods:
A randomized, double-blind, placebo-controlled trial was conducted at the Third Central Hospital of Tianjin, China from March to December 2023. A total of 110 female patients with melasma linked to kidney deficiency and blood stasis were enrolled and treated with either LDBG or a placebo twice daily for 60 days. Efficacy was assessed through measures such as the total melasma area, reduced melasma area, reduction rate of melasma area, melasma color score, Melasma Area and Severity Index (MASI) score, and traditional Chinese medicine (TCM) symptom score scale. Safety assessments included routine blood and biochemical tests.
Results:
Participants in both groups were aged 52–63 years, with no significant differences. After the 2-month intervention, the total melasma area decreased in both groups; however, a greater reduction was observed in the test group [462.50 mm2 (12.81%) vs. 100.00 mm2 (3.11%), P < .001]. Moreover, LDBG treatment significantly reduced the MASI and melasma color scores in the test group (P < .05). The total TCM symptom evaluation score significantly decreased (test group: 6.00 vs. placebo group: 7.00, P = .001), with significant relief in symptoms such as improvement in dark lips, nails, and waist soreness in the test group, compared with that in the placebo group (P < .05). Within-group comparisons revealed that TCM syndrome was significantly alleviated in the test group (P < .05).
Conclusion
LDBG intervention shows promising effectiveness in reducing female melasma and alleviating TCM syndromes.
8.Survey on human T-lymphotropic virus infection among blood donors in Hunan province
Binbin ZOU ; Qing HU ; Ni SUN ; Xiangmei KANG ; Tingting HU ; Fei FAN ; Feixue ZHAO
Chinese Journal of Blood Transfusion 2025;38(8):1077-1082
Objective: To investigate the prevalence of human T-lymphotropic virus (HTLV) infection among blood donors in Hunan Province from 2022 to 2024. Methods: A total of 1 830 342 blood donors from 14 prefecture-level blood centers in Hunan Province over the past three years were screened for anti-HTLV-Ⅰ/Ⅱ using enzyme-linked immunosorbent assay (ELISA). Initially reactive samples were further tested with Line Immunoassay (LIA
)/MP-Western blot and RT-PCR nucleic acid test for confirmation. Blood donors confirmed positive for HTLV were tracked and followed up. Results: From 2022 to 2024, the initial ELISA reactive rate for anti-HTLV-I/II among blood donors in Hunan Province was 1.36 per 10 000 (249/1 830 342). The confirmed positive rate was 0.20 per 10 000 (37/1 830 342), accounting for 14.86% of the initially reactive donors. The follow-up success rate for confirmed HTLV-positive blood donors was only 18.92%, while that for HTLV-indeterminate donors was 54.17%. Conclusion: The confirmed HTLV infection rates in Yueyang, Loudi, Shaoyang, Yiyang, and Zhuzhou cities were higher than the provincial (0.20 per 10 000). Chenzhou, Yongzhou, Zhangjiajie, and Xiangxi were identified as low prevalence areas, with an infection rate of 0. The overall follow-up success rate was low, indicating significant difficulties and bottlenecks in follow-up work. The comprehensive screening for HTLV and follow-up studies in Hunan provide valuable data to further improve blood safety testing strategies and risk warning mechanisms.
9.Epidemiological survey of knee osteoarthritis and analysis of related risk factors among military personnel in plateau regions
Pei-Jie LI ; Yong-Jie QIAO ; Ya-Fei CAO ; Jian-Kang ZENG ; Fei TAN ; Jia-Huan LI ; Rui-Ling XU ; Shuo YE ; Sheng-Hu ZHOU
Medical Journal of Chinese People's Liberation Army 2025;50(11):1374-1381
Objective To investigate the epidemiological characteristics of knee osteoarthritis(KOA)among military personnel in plateau regions and to explore its risk factors.Methods From July 2023 to July 2024,a multi-stage stratified cluster random sampling method was employed to survey the prevalence of KOA and related risk factors among military personnel in the northwest plateau regions of China,covering different altitudes(1500-4500 m)and geographical areas(Gansu,Qinghai,Tibet,and Xinjiang).All study subjects were divided into KOA and non-KOA groups based on the presence or absence of KOA.Variables including age,gender,body mass index(BMI),education level,smoking status,military rank,military branch,service duration,regional altitude,annual average temperature,training duration,perceived training intensity,and history of knee injury were selected for univariate analyses between groups.Variables with P<0.05 in the univariate analyses were included in the binary multifactor logistic regression to identify risk factors for KOA.Results A total of 3000 questionnaires were distributed,and 2854 valid questionnaires were collected,with a response rate of 95.13%.The sample included 2584 males and 270 females,with 510 cases of KOA,resulting in a prevalence rate of 17.9%.Univariate analysis showed that there were statistically significant differences between KOA and non-KOA groups in terms of age,BMI,smoking status,military rank,military branch,service duration,regional altitude,annual average temperature,training duration,perceived training intensity,and history of knee injury(P<0.05).However,no significant differences were found in gender and education level(P>0.05).Binary multivariate logistic regression analysis revealed that older age(OR=1.382,P=0.017),higher BMI(P<0.01),smoking(OR=1.929,P<0.01),higher military rank(OR=1.485,P=0.007),being a member of the Armed Police(P<0.01),longer service duration(P<0.01),higher regional altitude(OR=1.459,P<0.01),lower annual average temperature(OR=1.188,P=0.001),longer training duration(P<0.01),higher perceived training intensity(OR=2.450,P<0.01),and history of knee injury(OR=2.768,P=0.002)were independent risk factors for KOA.Conclusions Older age,overweight/obesity,smoking,higher military rank,being a member of the Armed Police,longer service duration,higher altitude,cold climate,longer training duration,higher training intensity,and history of knee injury are independent risk factors for KOA among military personnel in the northwest plateau regions of China.
10.Preparation of anti-influenza virus nanobodies and their applications in nanobody-ELISA
Fei WANG ; Yuchang LI ; Sen ZHANG ; Yuehong CHEN ; Tao JIANG ; Shuhong MAO ; Xiaoping KANG
Military Medical Sciences 2025;49(3):161-170
Objective To develop nanobodies with broad-spectrum reactivity,specificity,and high sensitivity that can be used for detecting multiple subtypes of influenza A virus,and to establish a nanobody-based enzyme-linked immunosorbent assay(ELISA)method.Methods Gene sequences of twelve nanobodies against influenza A virus were retrieved from the National Center for Biotechnology Information(NCBI)and nanobody databases.The nanoantibodies were prepared using molecular biological techniques including gene synthesis and recombinant expression.The binding activity,specificity,sensitivity,and affinity of these nanobodies were determined by ELISA screening and Gator affinity analysis.A double-antibody sandwich ELISA assay was established by combining the selected nanobody with a traditional mouse monoclonal antibody.Results Twelve nanobodies were expressed and purified.Two nanobodies capable of binding to multiple subtypes of influenza virus including H1,H3,H5,H7,and H9 were obtained and designated as VHH54 and KV108.Both nanobodies showed no cross-reactivity with other respiratory virus antigens.Furthermore,the KV108 nanobody exhibited the highest binding affinity,with a dissociation constant of 5.94×10-9mol/L for the influenza virus nucleoprotein(NP),and the lowest detection concentration for the NP antigen reached 0.00064 μg/mL.The double-antibody sandwich ELISA,using a combination of KV108 and a mouse monoclonal antibody,could sensitively detect the five common subtypes of influenza A virus(H1N1,H3N2,H5N1,H7N9,and H9N2).The lowest detection limit reached 110-403 PFU/mL,which was higher than that of the commercial colloidal gold kitfor influenza virus detection.Conclusion This study has identified a nanobody KV108,which is capable of binding to multiple subtypes of influenza virus,and established a nanobody-based ELISA method that can detect multiple subtypes of influenza A virus.This study can facilitate the development of nanobody-based influenza detection technologies.


Result Analysis
Print
Save
E-mail