1.Analysis of the impact of intraoperative RhE antigen-matched transfusion on early prognosis in liver transplant patients
Xiaochao YU ; Xinyuan GAO ; Fan HAI ; Chao YANG ; Xingyu HOU ; Yaping XING ; Hongqiang GAO ; Hongwei ZHANG ; Gang SU ; Ronghua XU
Chinese Journal of Blood Transfusion 2026;39(1):44-50
Objective: To investigate the impact of RhE antigen-matched transfusion during liver transplantation on early postoperative recovery and complications. Methods: In this retrospective cohort study, ninety-five patients undergoing liver transplantation at Kunming First People's Hospital between January 2022 and July 2025 were enrolled. Patients were divided into two groups: Group 1 (RhE-mismatched transfusion, n=57) and Group 2 (RhE-matched transfusion, n=38). The baseline data, complete blood counts, hepatic and renal function, coagulation parameters, and complication rates between the two groups were compared at postoperative days 1, 3, 5, 7, and 10. Survival analysis was performed using the Kaplan-Meier method. Results: The baseline characteristics were well-balanced and comparable between the two groups (all P>0.05). The early postoperative mortality rate in the mismatched group (31.58%, 18/57) was significantly higher than that in the matched group (10.53%, 4/38) (P=0.017). The incidence of postoperative hepatic encephalopathy was significantly higher in the mismatched group (50.88%, 29/57) than in the matched group (10.53%, 4/38) (P<0.001). The incidence of postoperative haemorrhage in the mismatched group (24.56%, 14/57) was higher than that in the matched group (5.26%, 2/38), with a statistically significant difference (P=0.014). The incidence of perioperative infection in the mismatched group (28.07%, 16/57) was higher than that in the matched group (10.53%, 4/38), with a statistically significant difference (P=0.04). Corresponding odds ratios (OR) and 95% confidence intervals indicated a lower risk of these adverse events in the matched group. On postoperative day 1, the change in activated partial thromboplastin time (-1.6, 20.5) in the mismatched group was greater than in the matched group (-0.2, 5.5). The change in international normalised ratio (-0.56, 1.22) in the mismatched group was greater than in the matched group (-0.18, 0.32), while the change in albumin (-4.0, 4.8) was smaller in the mismatched group than in the matched group (-2.5, 8.8). On postoperative day 5, the change in albumin (-0.41±7.83) in the mismatched group was smaller than in the matched group (2.68±4.53). At postoperative day 7, the change in albumin in the mismatched group (-0.61±7.38) was smaller than that in the matched group (2.51±5.85), while the change in D-dimer in the mismatched group (0.73, 7.4) was greater than that in the matched group (-1.6, 4.3). On postoperative day 10, the mismatched group exhibited significantly higher fibrinogen levels (-1.21, 1.78) than the matched group (-0.49, 0.97), and significantly longer prothrombin times (-11.3, -2.7) than the matched group (-6.2, -0.8) (all P<0.05). The matched group exhibited a mean overall survival (OS) of 32.803 months (95% CI:29.171-36.436 months), significantly exceeding the mismatched group's 28.996 months (95% CI:24.202-33.790 months). The log-rank test yielded statistically significant results (χ
=4.307, P=0.038). Conclusion: Implementing RhE blood group-matched transfusion during liver transplantation may help reduce early postoperative mortality and the incidence of major complication rates, promote faster recovery of coagulation and liver function, and thereby improve short-term patient outcomes.
2.Analysis and study on clinical blood transfusion of 4 157 patients with emergency transfusion
Jie SUN ; Yunhua SUN ; Renyu WANG ; Gang FAN ; Hongji FAN ; Dongfu XIE ; Junjie LIN
Chinese Journal of Blood Transfusion 2026;39(2):203-208
Objective: To provide evidence for improving emergency blood supply protocols by analyzing the clinical characteristics and disease distribution of emergency transfusion patients, especially those receiving≥10 units of red blood cells (RBCs). Methods: The data of 4 157 patients who urgently applied for large-volume blood transfusion in various hospitals in Shanghai from May 2024 to April 2025 were selected and analyzed statistically. Results: Tertiary gradeA hospitals accounted for the largest proportion of total transfusion volume (U) (48.79%, 8 420/17 256.5), with no statistically significant differences in RBC transfusion volumes among hospitals of different grades (P>0.05). All blood products are most widely used in tertiary hospitals. Obstetric blood transfusion (U)(19.07%, 3 277.5/17 190.5) was the most frequent. A-mong the hospitals of patients who received emergency blood transfusion with red blood cell suspension≥10 U, tertiary gradeA hospitals also had the largest transfusion volume (U)(47.19%, 1 107/2 346). In terms of disease types, the top three diseases in terms of blood transfusion volume (U) were obstetric transfusion (24.59%, 572/2 326), digestive diseases (14.53%, 338/2 326) and tumors (14.19%, 330/2 326). Conclusion: Tertiary grade A hospitals are the main demand units for emergency blood transfusion, with pregnant women and cancer patients being the core blood-using groups. It is suggested that the safety, timeliness and sufficiency of emergency blood transfusion be guaranteed by establishing a hierarchical blood supply mechanism, formulating single-disease blood transfusion plans and promoting precise blood transfusion guided by thromboelastography.
3.Four new sesquiterpenoids from the roots of Atractylodes macrocephala
Gang-gang ZHOU ; Jia-jia LIU ; Ji-qiong WANG ; Hui LIU ; Zhi-Hua LIAO ; Guo-wei WANG ; Min CHEN ; Fan-cheng MENG
Acta Pharmaceutica Sinica 2025;60(1):179-184
The chemical constituents in dried roots of
4.Causal relationship between immune cells and knee osteoarthritis:a two-sample bi-directional Mendelian randomization analysis
Guangtao WU ; Gang QIN ; Kaiyi HE ; Yidong FAN ; Weicai LI ; Baogang ZHU ; Ying CAO
Chinese Journal of Tissue Engineering Research 2025;29(5):1081-1090
BACKGROUND:Knee osteoarthritis(KOA)is a common chronic inflammatory disease that causes damage to joint cartilage and surrounding tissues.Immune cells play an important role in the immune-inflammatory response in knee osteoarthritis,but the specific mechanisms involved are still not fully understood. OBJECTIVE:To evaluate the potential causal relationship between 731 immune cell phenotypes and the risk of knee osteoarthritis using Mendelian randomization. METHODS:Summary statistics of genome-wide association studies(GWAS)for 731 immune cell phenotypes(from GCST0001391 to GCST0002121)obtained from the GWAS catalog and GWAS data for knee osteoarthritis from the IEUGWAS database(ebi-a-GCST007090)were used.Inverse variance-weighted method,MR-Egger regression,weighted median method,weighted mode method,and simple mode method were employed to investigate the causal relationship between immune cells and knee osteoarthritis.Sensitivity analyses were conducted to assess the reliability of the Mendelian randomization results.Reverse Mendelian randomization analysis was also performed using the same methods. RESULTS AND CONCLUSION:The forward MR analysis indicated significant causal relationships(FDR<0.20)between knee osteoarthritis and four immune cell phenotypes,namely CD27 on CD24+CD27+in B cells(OR=1.026,P=0.000 26,Pfdr=0.18),CD33 on CD33dim HLA DR-in myeloid cells(OR=1.014,P=0.000 50,Pfdr=0.18),and CD45RA+CD28-CD8br%CD8br in Treg cells(OR=1.001,P=0.000 78,Pfdr=0.18),and PDL-1 on monocytes in mononuclear cells(OR=0.952,P=0.000 98,Pfdr=0.18).These immune cell phenotypes showed direct positive or negative causal associations with the risk of knee osteoarthritis.Reverse Mendelian randomization analysis revealed no significant causal relationships(FDR<0.20)between knee osteoarthritis as exposure and any of the 731 immune cell phenotypes.The results of sensitivity analysis show that the P-values of the Cochran's Q test and the MR-Egger regression method for bidirectional Mendelian randomization were both greater than 0.05,indicating that there is no significant heterogeneity and pleiotropy in the causal effect analysis between immune cell phenotypes and knee osteoarthritis.To conclude,there may be four potential causal relationships between immune cell phenotypes,such as CD27 on CD24+CD27+cells,CD33 on CD33dim HLA DR-cells,CD45RA+CD28-CD8br%CD8br cells,and PDL-1 on monocytes,and knee osteoarthritis.These findings provide valuable clues for studying the biological mechanisms of knee osteoarthritis and exploring early prevention and treatment strategies.They also offer new directions for the development of intervention drugs.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Clinical comprehensive evaluation framework for direct oral anticoagulants in the prevention of cancer-associated venous thromboembolism
Yue WU ; Bingzheng SHEN ; Fan ZHANG ; Junfen ZENG ; Yanzhuo LIU ; Gang LIU ; Benhong ZHOU
China Pharmacy 2025;36(11):1384-1388
OBJECTIVE To establish a clinical comprehensive evaluation framework for direct oral anticoagulants (DOACs) in the prevention of cancer-associated venous thromboembolism (CAVTE), providing a methodological reference for the rational prevention and treatment of CAVTE as well as for the formulation and adjustment of macro-management strategies for anticoagulant drugs. METHODS Through literature retrieval, evaluation indicators were collected and organized to establish a preliminary indicator pool. The selection of evaluation indicators was carried out through two rounds of Delphi surveys using average score of indicator importance≥3.5 and a coefficient of variation (CV) <0.25 as the screening criteria. Analytic hierarchy process (AHP) was employed to finalize the indicator weights. RESULTS The authority levels (C)r of the two rounds of expert consultations were 0.877 and 0.943, with CV of 0.24 and 0.18, respectively. The Kendall concordance coefficients were 0.331 and 0.535 (P<0.05). After expert validation, six primary indicators and forty-six secondary indicators were finalized for inclusion in the evaluation framework. The primary indicators and their weightings, ranked in descending order, were as follows:“ effectiveness” (38.86%), “safety” (38.86%),“ cost-effectiveness” (10.67%),“ accessibility” (5.51%),“ suitability” (3.48%), and “innovation” (2.64%). The secondary indicators exhibited a weight range from 0.02% to 20.25%, with the top five secondary indicators being:“ incidence of intracranial hemorrhage” (20.25%), “reduction in all-cause mortality” (15.29%), “decrease in the incidence of pulmonary embolism” (8.82%), “reduction in the incidence of deep vein thrombosis” (7.25%), and “drug contraindications” (4.74%). CONCLUSIONS This study has established an authoritative, scientific, and reliable comprehensive clinical evaluation framework for the use of DOACs in the prevention of CAVTE.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail