1.Application of a digital chylous plasma assessment device in the determination of chylous plasma
Lingyue GUO ; Caina LI ; Hongyan GAO ; Wei WEI ; Ping ZHANG ; Yan LIU ; Yajie WANG ; Weidong HE
Chinese Journal of Blood Transfusion 2025;38(9):1236-1241
Objective: To develop a simple digital chylous plasma device and validate its ability to accurately, standardly, and non-destructively determine chylous plasma in blood banks and clinical transfusions in hospitals. Methods: A digital chylous plasma assessment device was designed and manufactured. This device was used to measure the chylous degrees of chylous plasma samples before freezing, after freeze-thawing, before viral inactivation, and after viral inactivation. The measured chylosity index values were categorized according to the requirements specified in Appendix A of the Chinese national standard GB 18469-2001 "Quality Requirements for Whole Blood and Blood Components". This process established a digital standard for chylous plasma, enabling the identification of severe, moderate and mild chylous plasma, and non-chylous plasma. Results: The initial simple product of the digital chylous assessment device was successfully designed and manufactured. There was no significant difference in the degree of chylous plasma between pre-freezing 468.11±217.73 lux and post-thawing 538.91±273.39 lux of chylous plasma (P>0.05), or between pre-viral inactivation 858.33±387.79 lux and post-viral inactivation 928.33±166.51 lux of chylous plasma (P>0.05). The median of chylous degree values for plasma chylous index grades 0 to 6 were 45 lux, 250 lux, 620 lux, 835 lux, 1 130 lux, 1 390 lux, and 1 700 lux, respectively. The defined cutoff values/ranges for the chylous degree values corresponding to plasma chylous index grade 0 to 6 were ≤125 lux, 126-465 lux, 466-740 lux, 741-1 000 lux, 1 001-1 233 lux, 1 234-1 560 lux, and ≥1 561 lux. Conclusion: This study successfully developed the initial product of the digital chylous device and established digital standards for classifying chylous plasma. The device demonstrates the potential to meet the needs for assessment of chylous plasma in both blood banks and clinical transfusions in hospitals, thereby promoting the development and application of standardized, non-destructive chylous plasma assessment technology.
2.Effect of weight monitoring feedback intervention among primary school students
HUANG Yangmei ; SHEN Xujuan ; XIE Dongying ; ZHANG Qi ; ZHENG Zicong ; WANG Meng
Journal of Preventive Medicine 2025;37(6):541-545
Objective:
To evaluate the effect of weight monitoring feedback intervention among primary school students, so as to provide the evidence for strengthening children's weight management.
Methods:
In October 2023, students from grades four to six in a primary school in Hangzhou City were selected and randomly assigned to a control group and an intervention group on a class-by-class basis. The included primary school students had their height and weight measured at a fixed time each week, and the results were fed back to their parents in the form of cards. The cards for the control group contained knowledge about healthy lifestyles, while those for the intervention group additionally included information on body mass index (BMI), BMI grouping, and BMI ranking. Overweight and obesity were determined according to the age- and gender-specific criteria in the Screening for Overweight and Obesity among School-aged Children and Adolescents. After a 9-month intervention period, the prevalence rates of overweight and obesity and lifestyle behavior data between the two groups before and after the intervention were compared by a generalized linear mixed model, in order to assess the effectiveness of the weight monitoring information feedback intervention.
Results:
The intervention group consisted of 368 students, including 208 boys (56.52%) and 160 girls (43.48%). The majority of students were 11 years, with 153 students accounting for 41.58%. The prevalence rate of overweight and obesity was 24.18%. The control group had 324 students, with 180 boys (55.56%) and 144 girls (44.44%). The predominant age was also 11 years, with 128 students accounting for 39.51%. The prevalence rate of overweight and obesity was 25.31%. Before the intervention, there were no statistically significant differences between the two groups in terms of gender, age, prevalence rate of overweight and obesity, eating habits, exercise situation, and sleep patterns (all P>0.05). After the intervention, there were significant interactions between group and time for the prevalence rate of overweight and obesity, the frequency of moderate-intensity exercise per week, and adequate sleep in the two groups (all P<0.05). The prevalence rate of overweight and obesity in the intervention group (OR=0.461, 95%CI: 0.252-0.845) was lower than that in the control group. The proportions of students in the intervention group who engaged in moderate-intensity exercise ≥4 times per week (OR=1.315, 95%CI: 1.033-1.675) and had adequate sleep (OR=1.402, 95%CI: 1.049-1.875) were higher than those in the control group.
Conclusion
Weight monitoring feedback can reduce the incidence of overweight and obesity among primary school students and has a certain improving effect on lifestyle behaviors such as exercise and sleep.
3.Research and development of an intelligent moxibustion instrument based on electromyography.
Xin PENG ; Tianyi ZHANG ; Dongying WANG ; Xuelian GU ; Zihao YU
Chinese Acupuncture & Moxibustion 2025;45(7):889-895
OBJECTIVE:
An intelligent moxibustion instrument based on electromyography was designed to evaluate the real-time therapeutic effect of moxibustion.
METHODS:
Taking Shenshu (BL23) as the subject, surface electromyography (sEMG) at the center and equidistant points of Shenshu (BL23) were collected. The characteristic parameters, integrated electromyography (iEMG) and root mean square (RMS) were calculated before and after moxibustion. After analyzing the effect of moxibustion, a function algorithm for the end-of-moxibustion was obtained. Using this algorithm and combined with STM32 technology, the control system of moxibustion instrument and the upper computer software were designed to achieve the precise control during moxibustion delivery. Finally, the function, stability and safety of the moxibustion instrument were verified through clinical trials to ensure its effectiveness in practical application.
RESULTS:
During one cycle of moxibustion at the center of Shenshu (BL23), the iEMG of sEMG decreased over time, meaning the decrease in muscle fatigue degree, and after one cycle of moxibustion, it elevated over time, showing the increase in muscle fatigue degree. RMS increased by 1.90% before and after moxibustion at the equidistant points of Shenshu (BL23), and the system indicated the end of moxibustion when RMS increased by 0.15%, and decreased by 0.13% at the center of Shenshu (BL23). The intelligent moxibustion instrument designed based on this algorithm can realize the function of mild moxibustion, and the effect of moxibustion can be evaluated by the real-time monitoring of RMS changes through the upper computer. During the operation of moxibustion instrument, moxa stick was fixed stably, remained a safe distance of 3 cm to 4 cm away from the skin surface. When the length of moxa stick was less than 5 cm left after ignited and the skin temperature exceeded the preset safety threshold of 48 ℃, the system was alarmed automatically.
CONCLUSION
The intelligent moxibustion instrument designed in the research can effectively evaluate the effect of moxibustion, and ensure the safety and stability during moxibustion delivery.
Humans
;
Moxibustion/methods*
;
Electromyography/instrumentation*
;
Adult
;
Male
;
Female
;
Young Adult
;
Acupuncture Points
;
Algorithms
;
Middle Aged
4.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
5.Historical Evolution and Key Information Research on Pediatric Famous Classical Formula Yigongsan
Jiangmin SU ; Jun ZHANG ; Cong GUO ; Anyi ZHAO ; Liang JIANG ; Heng ZHANG ; Jipeng DI ; Sha CHEN ; Li LIU ; Yan LIU ; An LIU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):205-214
Yigongsan is derived from Xiaoer Yaozheng Zhijue written by QIAN Yi in the Northern Song dynasty, which is the No. 3 formula in the Catalogue of Ancient Famous Classical Formulas(The Second Batch of Pediatrics) released by the National Administration of Traditional Chinese Medicine(TCM) in September 2022, and it can be developed as a class 3.1 new TCM drug. By referring to ancient medical books and modern literature, this study conducted herbal textual research on Yigongsan from five aspects, including historical evolution, origin and processing, dosage conversion, usage and preparation methods, and functional application, then formed the key information table of this formula, in order to provide reference for the development of reference samples and preparations of Yigongsan. Based on the results of the study, it is recommended that Panax ginseng should be removed the basal part of stem(rhizoma), Poria cocos should be removed the peel, Citrus reticulata should be cut into shreds and Glycyrrhiza uralensis should be used. According to 4.13 g/Qian(钱), 1 g/slice for ginger, 3 g for each jujube and 300 mL/Zhan(盏), the doses of Ginseng Radix, Poria, Atractylodis Macrocephalae Rhizoma, Glycyrrhizae Radix et Rhizoma, Citri Reticulatae Pericarpium, Zingiberis Rhizoma Recens, Jujubae Fructus were 1.652, 1.652, 1.652, 1.652, 1.652, 5, 6 g, and the total amount was 19.26 g. The decocting method was to crush the medicinal materials into fine powder with 50-80 mesh, add 300 mL of water and decoct to 210 mL for each dose, then remove the dregs and take it warmly. This formula was recorded in ancient books as the main treatment for the cold-deficiency of spleen and stomach, and Qi stagnation in children with vomiting and diarrhea and lack of appetite. It has been flexibly applied by later generations of physicians, and is often used to treat anorexia, inflammation of the digestive tract, diarrhea and other diseases in children.
6.Investigation the association between γδT cells with endometrial polyps
Zihan MENG ; Yulu YANG ; Huijuan ZOU ; Xueke ZHANG ; Wenjuan YANG ; Dongying SUN ; Xiaofeng XU
Acta Universitatis Medicinalis Anhui 2024;59(6):971-976
Objective To investigate the expression and clinical value of γδT cells and related inflammatory factors in endometrial polyps(EP).Methods Subjects were patients with infertility due to EP(EP group,n=57)and infertility due to non-uterine factors(Control group,n=44).EP tissues and normal endometrial tissues were taken,respectively.The general characteristics of the two groups were evaluated by independent samples T-test or Wilcoxon rank sum test.The expressions of CD3 and TCRγδ in proliferative endometrium and endometrial polyps were observed by immunofluorescence,and the expressions of IL-17 and IFN-γ in tissue homogenate were detected by ELISA.Uni-variable linear regression was used to analyze the correlation between the number of γδT cells and the expression level of IL-17 and IFN-γ.Results Both the number of γδT cells and he levels of IL-17 and IFN-γsignificantly increased in endometrial polyp tissues,and the relationship between is linear(all P<0.05).Conclu-sion γδT cells are associated with EP among infertile women,which may lead to embryo implantation failure by affecting the expression of inflammatory factors and regulating the imbalance of cell subsets.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.


Result Analysis
Print
Save
E-mail