1.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
2.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6. Epidemiological characteristics of acute paraquat poisoning in children in southwest Shandong and related factors of pulmonary interstitial fibrosis
Mengxiao SHEN ; Jinlong LIU ; Lei HAN ; Xuemei SUN ; Shengying DONG ; Chengjun LIU ; Baohai SHI ; Hongfeng ZHU ; Liping CHEN ; Tong CHEN ; Liwen LI ; Bo LI ; Zhaohua ZHANG ; Youpeng JIN
Chinese Pediatric Emergency Medicine 2020;27(1):30-34
Objective:
To analyze the epidemiological characteristics of acute paraquat(PQ)poisoning in children in southwest Shandong, and the risk factors for pulmonary interstitial fibrosis.
Methods:
This retrospective study was performed on the clinical data of children with acute PQ poisoning admitted from January 2013 to December 2017 in 12 hospitals in southwest Shandong.All participants were divided into pulmonary interstitial fibrosis group and no pulmonary interstitial fibrosis group on the basis of the chest CT 14 days after poisoning.The epidemiological characteristics and risk factors of pulmonary interstitial fibrosis were analyzed.
Results:
During the study period, a total of 307 children with acute PQ poisoning were admitted to 12 hospitals, of which 61 (19.87%) were suffering from acute PQ poisoning.Forty-nine cases with complete clinical data were analyzed, including 26 male and 23 female patients poisoned by oral.The age distribution ranged from 8 months to 14 years.Poisoning mainly occured from July to September of each year.The mortality of acute PQ poisoning was 8.2%(4/49), and the incidence of pulmonary interstitial fibrosis in survival patients was 44.4%(20/45). Statistical differences (
7.Analysis of the Detection Results of the Syphilis Specific Antibody in Blood Donors by Chemiluminescence Method and Enzyme Linked Immunosorbent Assay.
Shou-Shan MEN ; Fa-Kui SHANG ; Chun-Hua HAN ; Jin-Xiang SONG ; Jing-Yin HAN
Journal of Experimental Hematology 2017;25(1):226-230
OBJECTIVETo investigate the application value of chemiluminescence method (CMIA) detection of Treponema pallidum (TP) specific antibodies in the blood test.
METHODSOver the same period the de novo enzyme linked immunosorbent assay (ELISA) and Abbott chemical luminescence method were used to detect the specific antibody of syphilis in a total of 66298 samples; TP-ELISA negative and TP-CMIA positive unpaid blood donation blood samples for syphilis specific antibody were detected and confirmed by Western blot.
RESULTSBlood samples from 66298 blood donors were detected by TP-ELISA, the positive samples was 250 and the positive rate was 0.38%. The positive samples of TP-CMIA was 297, the positive rate was 0.45%, the difference was statistically significant (P<0.05). The blood samples of 47 unpaid blood donors were confirmed by TP-Western blot method, as a result, 32 samples were positive, 15 were negative, and result detected by TP-ELISA method was negative.
CONCLUSIONTP-CMIA sensitivity is higher than that of TP-ELISA, and possesses higher sensitivity and specificity, and quick detection, simple operation, easy automation, suggesting greater application value in blood detection of Treponema pallidum.
8.Analysis of gastric gastrointestinal stromal tumors in Shandong Province: a midterm report of multicenter GISSG1201 study.
Qingsheng HOU ; Wenqiang LUO ; Leping LI ; Yong DAI ; Lixin JIANG ; Ailiang WANG ; Xianqun CHU ; Yuming LI ; Daogui YANG ; Chunlei LU ; Linguo YAO ; Gang CUI ; Huizhong LIN ; Gang CHEN ; Qing CUI ; Huanhu ZHANG ; Zengjun LUN ; Lijian XIA ; Yingfeng SU ; Guoxin HAN ; Xizeng HUI ; Zhixin WEI ; Zuocheng SUN ; Hongliang GUO ; Yanbing ZHOU
Chinese Journal of Gastrointestinal Surgery 2017;20(9):1025-1030
OBJECTIVETo summarize the treatment status of gastric gastrointestinal stromal tumor (GIST) in Shandong province,by analyzing the clinicopathological features and prognostic factors.
METHODSClinicopathological and follow-up data of 1 165 patients with gastric GIST between January 2000 and December 2013 from 23 tertiary referral hospitals in Shandong Province were collected to establish a database. The risk stratification of all cases was performed according to the National Institutes of Health(NIH) criteria proposed in 2008. Kaplan-Meier method was used to calculate the survival rate. Log-rank test and Cox regression model were used for univariate and multivariate prognostic analyses.
RESULTSAmong 1 165 cases of gastric GIST, 557 were male and 608 were female. The median age of onset was 60 (range 15-89) years. Primary tumors were located in the gastric fundus and cardia in 623 cases(53.5%), gastric body in 346 cases(29.7%), gastric antrum in 196 cases(16.8%). All the cases underwent resection of tumors, including endoscopic resection (n=106), local resection (n=589), subtotal gastrectomy(n=399), and total gastrectomy(n=72). Based on the NIH risk stratification, there were 256 cases (22.0%) at very low risk, 435 (37.3%) at low risk, 251 cases (21.5%) at intermediate risk, and 223 cases (19.1%) at high risk. A total of 1 116 cases(95.8%) were followed up and the median follow-up period was 40 (range, 1-60) months. During the period, 337 patients relapsed and the median time to recurrence was 34 (range 1-60) months. The 1-, 3-, and 5-year survival rates were 98.6%, 86.1% and 73.4%, respectively. The 5-year survival rates of patients at very low, low, intermediate, and high risk were 93.1%, 85.8%, 63.0% and 42.3% respectively, with a statistically significant difference (P=0.000). Multivariate analysis showed that primary tumor site (RR=0.580, 95%CI:0.402-0.835), tumor size (RR=0.450, 95%CI:0.266-0.760), intraoperative tumor rupture(RR=0.557, 95%CI:0.336-0.924), risk classification (RR=0.309, 95%CI:0.164-0.580) and the use of imatinib after surgery (RR=1.993, 95%CI:1.350-2.922) were independent prognostic factors.
CONCLUSIONSThe choice of surgical procedure for gastric GIST patients should be based on tumor size. All the routine procedures including endoscopic resection, local excision, subtotal gastrectomy and total gastrectomy can obtain satisfactory curative outcomes. NIH classification has a high value for the prediction of prognosis. Primary tumor site, tumor size, intraoperative tumor rupture, risk stratification and postoperative use of imatinib are independent prognostic factors in gastric GIST patients.
9.Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center.
Shou-Shan MEN ; Lian-Zhi LV ; Yuan-Feng CHEN ; Chun-Hua HAN ; Hong-Yu LIU ; Yan YAN
Journal of Experimental Hematology 2017;25(6):1815-1819
OBJECTIVETo investigate the blood test patterns for blood donors after nucleic acid detection in blood center.
METHODSThe collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBVpersons the serological test yet should be performed.
RESULTSIn 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV(0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV(1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV(1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBVby 6-fold dilution for virus concentration found only 4 samples with HBV. In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ=8.11, P<0.05); but there was no statistical difference between unqualified rate of ID-NAT and MP-6-NAT(1.3‰ vs 1.28‰)(χ=0.00, P>0.05). In 41 samples with HBsAgHBV DNAdetected by ELISA, 36 samples were confirmed to be occult HBV infective(OBI) by HBsAb, HBcAb test of ELISA; out of these 41 samples, 33 samples showed HBcAb(91.66% of OBI), 5 might be HBV "window period" infective, moreover the HCV RNA and HIV RNA positive samples were not found.
CONCLUSIONTo avoid the missdiagnosis of donors with low level of virus, the nucleic acid test must be carried out after virus concentration of mixed samples when the blood test pattern of donors is nucleic acid test of mixed samples, otherwise the single nucleic acid test must be performed to obtain more high detected rate of virus nucleic acid. The HBcAb serologic test and physical examination of donors before blood donation must be enhanced on basis of serological test of HBsAg; for high risk people, the persuading no blood donation is simplest pattern.
10.Changes of ADAMTS13 Activity and TSP1 Level in Patients with Hematologic Malignancies.
Cai-Feng SUN ; Xia ZHAO ; Fang HAN ; Qi JIA ; Liang WANG ; Guang LU ; Hui-Fang DING
Journal of Experimental Hematology 2016;24(5):1294-1298
OBJECTIVETo investigate the changes of thrombospondin 1(TSP1) level and von Willebrand factor cleaving protease(ADAMTS13) activity in the patients with hematologic malignancies before and after treatment and to evaluate their clinical significance.
METHODSEighty-two patients with hematologic malignancies were enrolled in this study, among them 20 patients were with acute leukemia, 48 patients were with lymphoma and 14 patients were with multiple myeloma. The plasma samples of 82 patients with hematologic malignancies and 45 healthy controls were collected. The activities of ADAMTS13 were evaluated by residue collagen binding assay(R-CBA), the levels of TSP1 and vWF antigen were measured by enzyme-linked immunosorbent assay(ELISA).
RESULTSThe activity of plasma ADAMTS13 in patients with hematologic malignancies was lower than that of normal controls(P<0.05). The levels of vWF antigen and TSP1 in the patients with hematologic malignancies were higher than those in normal controls(P<0.05). After standard induction chemotherapy, the ADAMTS13 activity of the patients with hematologic malignancies at the complete remission was higher than that before therapy(P<0.05); the vWF antigen level was significantly lower than that in the patients with hematologic malignancies before therapy(P<0.05), but still higher than that in controls(P<0.05). There were 25 infection patients in 82 cases of hematologic malignancies, and the ADAMTS13 activity in the patients with newly diagnosed hematologic malignancies complicated with infection before therapy was obviously lower than that in the patients with hematologic malignancies without infection(P<0.05), the levels of vWF antigen and TSP1 were significantly lower than that in patients without infection (P<0.05). In the process of treatment, 8 patients have been speculated to suffer from thrombus, and the ADAMTS13 activity in the patients with thrombus was obviously lower than that in the patients without thrombus(P<0.05).
CONCLUSIONLow ADAMTS13 activity and high TSP1 level may participate in the progress of hematologic malignancies, the infection and thrombotic events may lead to further reduction of the ADAMTS13 activity. Assaying the level of ADAMTS13 activity in the patients with malignant tumor may be helpful to prevent the infection and thrombosis in the patients with hematologic malignancies.

Result Analysis
Print
Save
E-mail