1.Discussion on the Role of Ferroptosis in Chronic Obstructive Pulmonary Disease from the Perspective of "Qi Deficiency with Retention and Stagnation"
Yuchen GAO ; Hongyu ZHU ; Heyue XIA ; Dian ZENG ; Cheng YANG ; Jiabing TONG ; Zegeng LI ; Qinjun YANG
Journal of Traditional Chinese Medicine 2026;67(11):1167-1172
Ferroptosis is a key driver of the onset and progression of chronic obstructive pulmonary disease (COPD). By exploring the role of ferroptosis in COPD from the perspective of "qi deficiency with retention and stagnation", it is considered that mitochondrial dysfunction and imbalanced antioxidant defenses are the microscopic manifestations of "qi deficiency", whereas iron accumulation and lipid peroxide deposition constitute the pathological basis of "retention and stagnation". In traditional Chinese medicine (TCM), the treatment principle is tonifying deficiency and benefiting qi, scattering retention and unblocking stagnation. Its mechanism involves improving the antioxidant system and mitochondrial function to enhance cellular resistance to ferroptosis, as well as relieving pulmonary iron overload, excessive lipid peroxidation, and inflammatory factor release to reduce the accumulation of pathological products, thereby exerting therapeutic effects on COPD.
2.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
3.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
4.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
5.Study on the characteristics and mechanisms of skin damage in mice after high-voltage electric shock based on metabolomics
Xiao YANG ; Ping DENG ; Si-yu CHEN ; Jing-dian LI ; Hui WANG ; Yang YUE ; Zheng-ping YU ; Peng GAO ; Hui-feng PI
Journal of Regional Anatomy and Operative Surgery 2025;34(5):379-385
Objective To study the damage effect of high-voltage electric shock on skin based on metabolomics,analyze its metabolic differences,and explore its injury mechanism.Methods A total of 16 SPF C57BL/6J male mice were divided into the electric shock group(head skin received electric shock treatment)and control group(head skin received electric shock acoustic-optical stimulation),and the skin appearance after treatment of mice in the two groups was observed.The histopathological changes caused by electric shock were analyzed by HE staining,EVG staining and Masson staining.GC-MS and LC-MS metabonomics were used to analyze the changes of skin metabolism spectrum and tissue metabolites after electric shock exposure,and the differential metabolites were analyzed.The obtained differential metabolites were combined and KEGG enrichment analysis was conducted.Results After high-voltage electric shock,the skin of mice could be damaged to the dermis,and the epidermis was partially thickened,lifted and separated.The structure of skin appendages in the dermis was destroyed,with a large number of inflammatory cells infiltrating and obvious swelling,accompanied by congestion,which led to severe skin inflammatory reaction and impaired skin barrier function.Metabonomics analysis suggested that the metabolites changed after electric shock exposure.KEGG enrichment analysis showed that electric shock significantly affected the central carbon metabolism pathway of cancer,pentose phosphate pathway,purine metabolism,glycine,serine and threonine metabolism processes,amino acid tRNA biosynthesis mechanism,glycerophospholipid metabolism pathway,pyrimidine metabolism pattern,glycolysis/gluconeogenesis,alanine metabolism process,glucagon signal pathway and so on.Conclusion High voltage electric shock can cause deep skin damage,disturb its energy metabolism and amino acid metabolism,and seriously interfere with its antioxidant and DNA repair system functions.
6.Effect of icilin on MPTP-induced nerve damage in Meriones unguiculatus
Xiyu GAO ; Shoupeng FU ; Aohan YAN ; Yue SUN ; Shuo YANG ; Yiming ZHANG ; Dian-feng LIU ; Dewei HE
Chinese Journal of Veterinary Science 2025;45(5):1053-1059
Parkinson's disease(PD)is the second most prevalent neurodegenerative disease and a major cause of movement disorders.Neuroinflammation plays an important role in the pathogenesis of PD.Icilin is a small molecule compound that has been reported to inhibit inflammation.Howev-er,its role in PD has not been reported.This study explored the effects of icilin on motor behavior,nerve damage,microglia activation,and neuroinflammation in MPTP-induced PD Meriones unguic-ulatus by behavioral experiments,immunohistochemistry,Western blot,and fluorescence quantifi-cation.The results showed that Icilin not only ameliorated motor dysfunction and neurological damage in MPTP-induced Meriones unguiculatus,but also inhibited microglia hyperactivation and its mediated neuroinflammation.The present study provides an evidence that icilin attenuates MPTP-induced neurodegenerative lesions in long-pawed gerbils,suggesting that it is a promising candidate for PD.
7.Design and practice of three-dimensional teaching mode for Medical Immunology
Pengtao JIANG ; Zhifang HU ; Minghua LYU ; Ning WANG ; Xingchun GAO ; Ailian LI ; Dian ZHANG ; Fengliang JIANG ; Na GUO
Chinese Journal of Immunology 2025;41(5):1223-1227
In order to adapt to teaching reform of Medical Immunology and create a"golden course",through teaching prac-tice,our research group proposes a"three-dimensional curriculum teaching system",which organically combines teaching concepts with teaching design and process,with construction of various resources(material libraries),and finally,multi-level teaching evalua-tion is completed to achieve overall unity of teaching.
8.Study on the characteristics and mechanisms of skin damage in mice after high-voltage electric shock based on metabolomics
Xiao YANG ; Ping DENG ; Si-yu CHEN ; Jing-dian LI ; Hui WANG ; Yang YUE ; Zheng-ping YU ; Peng GAO ; Hui-feng PI
Journal of Regional Anatomy and Operative Surgery 2025;34(5):379-385
Objective To study the damage effect of high-voltage electric shock on skin based on metabolomics,analyze its metabolic differences,and explore its injury mechanism.Methods A total of 16 SPF C57BL/6J male mice were divided into the electric shock group(head skin received electric shock treatment)and control group(head skin received electric shock acoustic-optical stimulation),and the skin appearance after treatment of mice in the two groups was observed.The histopathological changes caused by electric shock were analyzed by HE staining,EVG staining and Masson staining.GC-MS and LC-MS metabonomics were used to analyze the changes of skin metabolism spectrum and tissue metabolites after electric shock exposure,and the differential metabolites were analyzed.The obtained differential metabolites were combined and KEGG enrichment analysis was conducted.Results After high-voltage electric shock,the skin of mice could be damaged to the dermis,and the epidermis was partially thickened,lifted and separated.The structure of skin appendages in the dermis was destroyed,with a large number of inflammatory cells infiltrating and obvious swelling,accompanied by congestion,which led to severe skin inflammatory reaction and impaired skin barrier function.Metabonomics analysis suggested that the metabolites changed after electric shock exposure.KEGG enrichment analysis showed that electric shock significantly affected the central carbon metabolism pathway of cancer,pentose phosphate pathway,purine metabolism,glycine,serine and threonine metabolism processes,amino acid tRNA biosynthesis mechanism,glycerophospholipid metabolism pathway,pyrimidine metabolism pattern,glycolysis/gluconeogenesis,alanine metabolism process,glucagon signal pathway and so on.Conclusion High voltage electric shock can cause deep skin damage,disturb its energy metabolism and amino acid metabolism,and seriously interfere with its antioxidant and DNA repair system functions.
9.Design and practice of three-dimensional teaching mode for Medical Immunology
Pengtao JIANG ; Zhifang HU ; Minghua LYU ; Ning WANG ; Xingchun GAO ; Ailian LI ; Dian ZHANG ; Fengliang JIANG ; Na GUO
Chinese Journal of Immunology 2025;41(5):1223-1227
In order to adapt to teaching reform of Medical Immunology and create a"golden course",through teaching prac-tice,our research group proposes a"three-dimensional curriculum teaching system",which organically combines teaching concepts with teaching design and process,with construction of various resources(material libraries),and finally,multi-level teaching evalua-tion is completed to achieve overall unity of teaching.
10.Deep learning image reconstruction algorithm in brain CT perfusion imaging with low tube voltage and reduced contrast agent dosage
Mengyuan ZHANG ; Luotong WANG ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Jiong ZHANG ; Songwei YUE ; Jianbo GAO ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(5):799-805
Objective To observe the value of deep learning image reconstruction(DLIR)algorithm in brain CT perfusion(CTP)using a protocol of 70 kVp and 40 ml contrast agent dose.Methods Totally 105 patients with suspected acute ischemic stroke(AIS)were prospectively enrolled and randomly divided into 3 groups,who underwent standard dose CTP scanning with 80 kVp and 150 mA combined with reconstruction as adaptive statistic iterative reconstruction V(ASIR-V)at 50%level(CN group,n=35),low dose(LD)scanning with 70 kVp and 100 mA combined with DLIR reconstruction at the highest level(DLIR-H)(LD group,n=35),or ultra-low dose(ULD)scanning with 70 kVp and 70 mA combined with DLIR-H reconstruction(ULD group,n=35).Radiation doses were compared among 3 groups.CT values and standard deviations(SDCT)of ROI of gray matter and white matter in the frontal,parietal and temporal lobes were measured.Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)between gray and white matter were calculated and compared among groups.Then pseudo-color images of cerebral blood volume(CBV),cerebral blood flow(CBF),mean transit time(MTT)and time to maximum of the tissue residual function(Tmax)were generated.The imaging quality of CTP pseudo-color images was evaluated,and the compatibility of the subjective scores within every kind of CTP pseudo-color images were assessed using Kappa test.Quantitative perfusion parameters were measured and compared among groups.Results Compared with CN group,both LD and ULD groups demonstrated significantly reduced volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)(all adjusted P<0.05).In ULD group,SDCT of white matter in frontal,parietal and temporal lobes were higher than those in CN group,and SDCT of white matter in parietal lobe was also higher than that in LD group(all adjusted P<0.05).No significant difference of SDCT of gray matter was observed among groups(all P>0.05).SNR of white matter in parietal and temporal lobes in both LD and ULD groups were lower than those in CN group(all P<0.05),while no significant difference of SNR of white matter in frontal lobe,nor of gray matter in frontal,parietal and temporal lobes was found among groups(all P>0.05).CNR of gray and white matter in the frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).High consistency of inter-observer subjective scores of CBV maps,CBF maps and Tmax maps(Kappa of 0.623,0.644 and 0.638,respectively)were noticed,which of MTT maps had moderate consistency(Kappa=0.560).No significant difference of intra-obsever subjective scores of CTP pseudo-color images was found among groups(all P>0.05).CBV,CBF,MTT and Tmax values of gray and white matter in frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).Conclusion DLIR algorithm applicated in low radiation dose and reduced contrast agent dosage might ensure imaging quality.

Result Analysis
Print
Save
E-mail