1.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
2.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
3.Clinical study on Chinese materia medica soaking therapy combined with cervical rotation-traction manipulation in the treatment of cervical spondylotic radiculopathy
Di WANG ; Rui XIE ; Lei SHI ; Long GONG ; Jie LUO ; Peiyu SUN
International Journal of Traditional Chinese Medicine 2025;47(12):1682-1686
Objective:To observe the clinical efficacy of Chinese materia medica soaking therapy combined with cervical rotation-traction manipulation in the treatment of cervical spondylotic radiculopathy (CSR).Methods:A randomized controlled trial was conducted. Totally 84 CSR patients from the Orthopedics Department of Shunyi Hospital, Beijing Traditional Chinese Medicine Hospital from April 2023 to May 2024 were selected as the observation subjects. They were divided into two groups using a random number table method, with 42 patients in each group. The treatment for both groups lasted for 14 d. VAS scale was used to assess pain levels before and after treatment, OASTCSR was used to evaluate cervical function, and NDI was used to assess cervical functional status; adverse reactions during treatment were observed and recorded, and clinical efficacy was evaluated.Results:The total effective rate was 95.24% (40/42) in the treatment group and 80.95% (34/42) in the control group, with statistical significance ( χ2=4.36, P=0.029). After treatment, the VAS score (1.60±1.21 vs. 2.91±1.12, t=-1.89), the OASTCSR score (5.17±2.14 vs. 9.31±3.82, t=-11.57), and the NDI score (9.17±2.13 vs. 13.36±3.45, t=-10.82) in the treatment group were lower than those in the control group ( P<0.001 or P<0.05). During the treatment period, neither group experienced any adverse reactions. Conclusion:The combination of Chinese materia medica soaking therapy and cervical rotation-traction manipulation can significantly improve the clinical symptoms and quality of life of patients with CSR, and its efficacy is superior to the use of cervical rotation-traction manipulation alone.
4.Guidelines for the Digital Ancient Books of TCM Indexing
Weina ZHANG ; Bing LI ; Bin LI ; Jing XIE ; Yan DONG ; Wei LONG ; Chuchu ZHANG ; Tong WEI ; Sihong LIU ; Yang WU ; Hongtao LI ; Lin TONG ; Guangkun CHEN ; Fei DONG ; Rui WANG ; He LU ; Meng LI ; Jingpeng DENG ; Tengfei WANG ; Xiaoying LI ; Di ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(3):1-11
Guidelines for Digital Ancient Books of TCM Indexing(T/CIATCM 119-2024)is based on the theoretical knowledge,disciplinary methods,and practical applications of TCM classical cataloging.Taking digital ancient books of TCM as the object,it systematically reveals the content of TCM knowledge,which is an essential indexing processing standard for building an intelligent retrieval system for TCM ancient books,and can provide support for the deep development and innovative utilization of TCM knowledge.It can not only promote the co-construction and sharing of ancient book resources in the TCM industry,but also promote the standardization construction and application of TCM information.This standard specifies the principles,methods,and examples of free indexing of digital ancient books of TCM based on their original content.It is applicable to the indexing and processing of digital ancient books of TCM for TCM professional libraries and related institutions,and to the data processing and construction of various types of TCM ancient book databases.
5.Application of the Anderson sampler in the inspection for the filtration efficiency for bacteria in medical mask
Di LEI ; Chen WANG ; Minjuan ZHANG ; Cunlin LONG ; Jian REN ; Zhijie ZHAO ; Yuwei LI ; Yun LING ; Xiaoning SUN ; Jing ZHAO
China Medical Equipment 2025;22(3):160-163
The medical mask,which is used as an important tool of preventing the spread of respiratory diseases,can effectively block the transmission of biological aerosols.The detection for the filtration efficiency of bacteria in medical mask is particular importance.The Andersen sampler,is one kind of device that samples microbial aerosols,is widely used in the inspection for the filtration efficiency for bacteria in medical masks.It mainly consists of six impactors with different pore sizes.It simulates the deposition process of the most of particles at different positions in respiratory system through the bacterial particles in biological aerosols impact respectively the surface of petri dishes with agar under different pore sizes.This paper explored the development background,structure and sampling principle,operation and counting procedures of the Andersen sampler,as well as its application and importance in the inspection for the filtration efficiency for bacteria in medical mask.
6.Icariin targets PDE5A to regulate viability, DNA synthesis and DNA damage of spermatogonial stem cells and improves reproductive capacity.
Tian-Long LIAO ; Cai-Mei HE ; Di XIAO ; Zhi-Rong ZHANG ; Zuping HE ; Xiao-Ping YANG
Asian Journal of Andrology 2025;27(4):543-549
Icariin is a pure compound derived from Epimedium brevicornu Maxim, and it helps the regulation of male reproduction. Nevertheless, the role and underlying mechanisms of Icariin in mediating male germ cell development remain to be clarified. Here, we have demonstrated that Icariin promoted proliferation and DNA synthesis of mouse spermatogonial stem cells (SSCs). Furthermore, surface plasmon resonance iron (SPRi) and molecular docking (MOE) assays revealed that phosphodiesterase 5A (PDE5A) was an important target of Icariin in mouse SSCs. Mechanically, Icariin decreased the expression level of PDE5A. Interestingly, hydrogen peroxides (H 2 O 2 ) enhanced the expression level of phosphorylation H2A.X (p-H2A.X), whereas Icariin diminished the expression level of p-H2A.X and DNA damage caused by H 2 O 2 in mouse SSCs. Finally, our in vivo animal study indicated that Icariin protected male reproduction. Collectively, these results implicate that Icariin targets PDE5A to regulate mouse SSC viability and DNA damage and improves male reproductive capacity. This study thus sheds new insights into molecular mechanisms underlying the fate decisions of mammalian SSCs and offers a scientific basis for the clinical application of Icariin in male reproduction.
Male
;
Animals
;
Flavonoids/pharmacology*
;
Mice
;
Cyclic Nucleotide Phosphodiesterases, Type 5/drug effects*
;
DNA Damage/drug effects*
;
Cell Survival/drug effects*
;
Cell Proliferation/drug effects*
;
Spermatogonia/drug effects*
;
Reproduction/drug effects*
;
Adult Germline Stem Cells/metabolism*
;
DNA Replication/drug effects*
7.Performance verification of fully automated chemiluminescence immunoassay analyzer in measuring special sequence indicators of serum β-CTx
Di LEI ; Jian REN ; Minjuan ZHANG ; Xiaoning SUN ; Yingjun LI ; Xiaodong ZHANG ; Cunlin LONG
China Medical Equipment 2025;22(8):57-60
Objective:To verify the performance of MAGLUMI 4000 fully automatic chemiluminescence immunoassay analyzer in measuring special sequence of β-Collagen(β-CTx).Methods:Referring to a series of standards included WS/T 492-2016"Verification of performance for precision and trueness of quantitative measurements in clinical laboratories"and CNAS-GL037 2019"Guidance on the verification of quantitative measurement procedures used in the clinical chemistry",the precision,trueness,and linear interval of MAGLUMI 4000 fully automatic chemiluminescence immunoassay analyzer were verified in measuring β-CTx.Results:The intra batch precisions(repeatability)of MAGLUMI 4000 fully automatic chemiluminescence immunoassay analyzer were respectively 3.22%and 3.49%in measuring serum β-CTx samples with low and high values.The intermediate precisions(precision within laboratory)were respectively 4.35%and 3.29%,both of which met the requirements of laboratory.The results of trueness verification showed that the bias of samples with low concentration was-2.4%,and the bias of samples with high concentration was-2.1%.The expected values of the standards with low and high values were all between the corresponding up and low validation limits of them,which met the judgment criteria.The linear interval was 0.03-6.00 ng/mL,which was within the linear interval,and it can meet the requirements of manufacturer′s claim.Conclusion:The precision,trueness and linear interval of MAGLUMI 4000 fully automatic chemiluminescence immunoassay analyzer all passed the verification in measuring β-CTx,which indicates the performance of the project can meet the quality specifications.
8.Construction and identification of a sizeable naive human Fab phage display antibody library
Yakun ZHAO ; Xiaoyue WEI ; Fanliang MENG ; Wentao LIU ; Jiaming FAN ; Lijin LONG ; Wanting WANG ; Jianling CHEN ; Jianzhong ZHANG ; Lihua HE ; Liyong LIU ; Rui ZHAO ; Di SUN ; Xuezhen YUAN ; Xiaomei YAN
Chinese Journal of Epidemiology 2025;46(2):288-295
Objective:To construct a sizeable naive human Fab phage display antibody library to screen high-affinity specific antibodies in vitro. Methods:Total RNA was extracted from peripheral blood mononuclear cells (PBMCs) of 126 healthy individuals, subsequently reverse-transcribed into cDNA, and used as a template. PCR amplification was performed to obtain the V H from IgG, IgM and light chain κ, λ, separately, with the initial PCR products serving as templates for a second round of PCR. Overlap extension PCR was employed to generate fragments of the κ and λ light chains. These fragments were ligated with the phage vector pNC3, which harbors the variable region 1 of the heavy chain, to construct a recombinant phage plasmid. This plasmid was then electroporated into competent Escherichia Coli TG1 cells to establish a naive human Fab phage display antibody library. One hundred clones were randomly selected for identification and sequencing, and antibody gene polymorphisms were analyzed using the IMGT database and MAFFT software. Recombinant α-hemolysin from Staphylococcus aureus was utilized to screen Fab antibody fragments through biopanning of the antibody library, followed by random selection of phage ELISA-identified clones. The positive clones (antigen A450∶blank control A450≥2.1) were sequenced. Results:Two large naive Fab phage display antibody libraries were successfully constructed, in which the capacity of κ and λ chain antibody libraries were 1.25×10 11 and 1.54×10 11, respectively. The titers for two antibody libraries were 6.04×10 13 CFU/ml and 3.50×10 13 CFU/ml. The positive transformation insertion rates for κ and λ chain antibody libraries were 96% (96/100) and 100% (100/100), respectively. Sequence analysis revealed that all antibody sequences were unique. The amino acid sequences in the skeletal region were relatively conserved. In contrast, significant variations in the length of the complementarity determining region (CDR) were found, and the diversity of amino acid sequence of the complementary determining region was high, especially the CDR3. Analysis using the IMGT database indicated that the sequences exhibited a broad distribution across variable-diversity-joining gene families. After six rounds of panning, specific phage antibodies enrichment targeting α-hemolysin were achieved. A total of 142 monoclonal antibodies were sequenced, yielding 8 distinct Fab antibody sequences. Conclusion:This study successfully constructed two naive human Fab phage display antibody libraries with large capacity and good diversity, which can be used for screening human antibodies for serum epidemiology.
9.Fetal heart quantification technology for assessing normal fetal cardiac morphology and function: a prospective cohort study
Qiuyi DI ; Xiangdang LONG ; Jing NING ; Sui YAO ; Qiaorong LI ; Yu ZHUO ; Xuan CHEN ; Longfei SHI
Chinese Journal of Perinatal Medicine 2025;28(3):211-218
Objective:To explore the value of fetal heart quantification technology in assessing the morphology and function of the fetal heart during normal pregnancy.Methods:This prospective cohort study selected normal fetuses from healthy pregnant women who underwent prenatal ultrasound examinations at Hunan Provincial People's Hospital from January 2023 to October 2024. Using the GE Voluson E10 color Doppler diasonography, routine obstetric ultrasound and fetal echocardiography were performed to assess fetal growth and development and to exclude intracardiac and extracardiac malformations. Clear four-chamber view (4CV) dynamic images of the heart showing the endocardium (duration ≥3 s) were collected. Speckle-tracking analysis was performed using fetal heart quantification software. The measured indicators included the global spherical index (GSI), end-diastolic length of the heart (L-ED), end-diastolic width of the heart (W-ED), and the global longitudinal strain (GLS), fractional area change (FAC), and 24-segment spherical index (SI) of the left ventricle (LV) and right ventricle (RV). The cases were divided into five groups based on gestational age at the time of prenatal ultrasound: 20 +0 to 23 +6, 24 +0 to 27 +6, 28 +0 to 31 +6, 32 +0 to 35 +6, and 36 +0 to 40 +6 weeks. One-way analysis of variance, two independent samples t-test, univariate linear regression analysis, and Pearson correlation analysis were used to explore the differences in the above indicators among different gestational age groups and their correlation with gestational age. Results:A total of 200 pregnant women were included in the cohort, four cases were excluded due to poor image quality that prevented accurate tracking and measurement of relevant indicators. Ultimately, 196 cases (20 +0 to 23 +6 weeks 40 cases, 24 +0 to 27 +6 weeks 34 cases, 28 +0 to 31 +6 weeks 41 cases, 32 +0 to 35 +6 weeks 48 cases, and 36 +0 to 40 +6 weeks 33 cases) were included in the study, with a successful image analysis rate of 98.0%. (1) There were statistically significant differences in 4CV L-ED, 4CV W-ED, LV-FAC, and RV-FAC among the groups at 20 +0 to 23 +6, 24 +0 to 27 +6, 28 +0 to 31 +6, 32 +0 to 35 +6, and 36 +0 to 40 +6 weeks [4CV L-ED: 28.0±3.0, 32.6±4.3, 40.9±4.3, 46.7±4.8, 53.1±5.8, F=3.72; 4CV W-ED: 21.9±1.8, 25.1±4.2, 31.7±3.0, 37.4±4.0, 42.0±4.9, F=2.61; LV-FAC: (51.4±8.0)%, (49.0±10.4)%, (47.3±7.3)%, (43.1±7.5)%, (40.7±8.2)%, F=2.94; RV-FAC: (49.9±10.8)%, (46.2±12.0)%, (46.3±8.3)%, (43.2±8.0)%, (41.9±5.6)%, F=3.09; all P<0.05].(2) The size of the normal fetal heart gradually increased with gestational age, while the heart morphology remained relatively stable (4CV L-ED and 4CV W-ED were positively correlated with gestational age, with regression coefficients of 1.313 and 1.325, respectively, both P<0.001;LV-FAC and RV-FAC were negatively correlated with gestational age with regression coefficients of -0.783 and -0.552, respectively, both P<0.001; GSI, LV-GLS and RV-GLS had no correlations with gestational age, all P>0.05). (3) The SI of LV segments 1 to 17 were higher than the SI of the corresponding RV segments, and the SI of RV segments 20-24 were higher than that of the corresponding LV segments (all P<0.001). Conclusion:Fetal heart quantification technology has a certain value in the assessment of fetal cardiac morphology and function.
10.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]

Result Analysis
Print
Save
E-mail