1.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
2.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
3.Status of Clinical Practice Guideline Information Platforms
Xueqin ZHANG ; Yun ZHAO ; Jie LIU ; Long GE ; Ying XING ; Simeng REN ; Yifei WANG ; Wenzheng ZHANG ; Di ZHANG ; Shihua WANG ; Yao SUN ; Min WU ; Lin FENG ; Tiancai WEN
Medical Journal of Peking Union Medical College Hospital 2025;16(2):462-471
Clinical practice guidelines represent the best recommendations for patient care. They are developed through systematically reviewing currently available clinical evidence and weighing the relative benefits and risks of various interventions. However, clinical practice guidelines have to go through a long translation cycle from development and revision to clinical promotion and application, facing problems such as scattered distribution, high duplication rate, and low actual utilization. At present, the clinical practice guideline information platform can directly or indirectly solve the problems related to the lengthy revision cycles, decentralized dissemination and limited application of clinical practice guidelines. Therefore, this paper systematically examines different types of clinical practice guideline information platforms and investigates their corresponding challenges and emerging trends in platform design, data integration, and practical implementation, with the aim of clarifying the current status of this field and providing valuable reference for future research on clinical practice guideline information platforms.
4.STAR Guideline Terminology(Ⅱ): Clinical Question Formulation, Evidence Retrieval and Appraisal, and Recommendation Development
Di ZHU ; Haodong LI ; Zijun WANG ; Qianling SHI ; Hui LIU ; Yishan QIN ; Yuanyuan YAO ; Zhewei LI ; Hongfeng HE ; Jinhui TIAN ; Long GE ; Yaolong CHEN ;
Medical Journal of Peking Union Medical College Hospital 2025;16(3):756-764
To introduce and analyze guideline terminology related to clinical question formulation, evidence retrieval and appraisal, and recommendation development. A systematic search was conducted in guideline development manuals and relevant methodological literature, covering publications up to October 25, 2024. Terminology related to the three aforementioned stages of related to guideline development was extracted from the included literature, standardized, and refined through consensus meetings to finalize a comprehensive terminology list and definitions. A total of 30 guideline development manuals and 15 methodological articles were included, and 23 core terms were identified. It is recommended to develop a standardized and scientifically sound guideline terminology system with unified naming, clear definitions, and alignment with the linguistic environment and usage habits in China. At the same time, it is essential to strengthen terminology training for both guideline developers and users based on this system, in order to deepen their correct understanding and proper application of guideline terminology.
5.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
6.Application of MRI diaphragmatic navigation technology combined with 3D LAVA-FLEX sequence in abdominal enhanced imaging of infants and young children
Di GUO ; Qian-cheng LI ; Cheng-long LI ; Shi-xian LI ; Li-ya LU ; Shu-juan WANG ; Chang-chang LIU ; Xiu-hong DAI
Journal of Regional Anatomy and Operative Surgery 2025;34(10):896-899
Objective To explore the application value of MRI diaphragmatic navigation technology combined with three dimensional liver acquisition with volume acceleration-flexible(3D LAVA-FLEX)sequence in abdominal enhanced imaging of infants and young children.Methods A retrospective analysis was conducted on imaging data of 84 infants and young children who underwent abdominal enhanced MRI examination in our hospital between January 2021 and December 2023.All 84 infants and young children initially underwent conventional dynamic contrast-enhanced 3D LAVA-FLEX sequence scanning;the delayed phase images obtained were included in the dynamic enhancement group.Subsequently,diaphragmatic navigation combined with 3D LAVA-FLEX sequence examination was implemented,and the obtained images were included in the diaphragm navigation group.Subjective scoring was performed for images in both groups,while the signal to noise ratio(SNR),contrast to noise ratio(CNR),and artifact quantification(AQ)were measured and compared between the two groups.Results The respiratory motion artifacts,the clarity of liver parenchyma enhancement,the clarity of liver vascular enhancement,the clarity of spleen parenchyma enhancement and the overall image quality score in the diaphragm navigation group were higher than those in the dynamic enhancement group,and the differences were statistically significant(P<0.05).There were statistically significant differences in SNR and AQ between the two groups of images(P<0.000 1),while there was no statistically significant difference in CNR between the two groups of images(P>0.05).Conclusion Diaphragmatic navigation technology combined with 3D LAVA-FLEX sequence imaging can improve the image quality of abdominal MRI enhanced imaging in infants and young children,and provide a reference for clinical diagnosis and treatment.
7.Molecular Mechanisms of Angiogenesis in Mg-Based Biodegradable Bone Implants
Jun-jie HUANG ; Jia-long WU ; Di LIU ; Peng GAO
Progress in Modern Biomedicine 2025;25(16):2705-2714
Magnesium(Mg)-based bone implants have emerged as a promising candidate in bone regeneration due to their elastic modulus matching natural bone,favorable biodegradability,and biocompatibility.The degradation-derived magnesium ions(Mg2+)promote angiogenesis through multifaceted molecular mechanisms,thereby accelerating bone healing.This review systematically elucidates key pathways by which Mg2+regulates vascularization:① Activation of the CGRP-FAK-VEGF signaling axis via dorsal root ganglia-mediated neurovascular coupling;② Stabilization of HIF-1α through inhibiting VHL-mediated ubiquitination degradation and activating MagT1/TRPM7 ion channels,thereby enhancing VEGF transcription;③ Modulation of Notch signaling to drive vascular endothelial differentiation of bone marrow mesenchymal stem cells(BMSCs);④The activation of PI3K/AKT signaling pathway enhances endothelial nitric oxide synthase(eNOS)activity,leading to increased nitric oxide(NO)production which subsequently promotes endothelial cell proliferation and migration;⑤Immunomodulatory effects via macrophage M2 polarization and subsequent secretion of angiogenic factors;⑥stimulation of PDGF-BB secretion from MC3T3-E1 pre-osteoblasts.Notably,Mg2+exhibits concentration-dependent pro-angiogenic effects(optimal range:1-10 mM)and specifically enhances type H vessel formation,which critically couples angiogenesis with osteogenesis to boost bone regeneration efficiency.
8.Autophagy in different subtypes of breast cancer cells mediated by p-AMPK and its molecular mechanisms
Xin-jiao YANG ; Ru-yao HU ; Zhe XIONG ; Di ZOU ; Jie CAI ; Cong-long XIA ; Zhong-bin BAI ; Hong-ye ZHAO
Chinese Pharmacological Bulletin 2025;41(5):898-907
Aim To investigate the effect of p-AMPK activity on autophagy in different subtypes of MDA-MB-231(triple-negative breast cancer cells)and MCF-7(estrogen receptor-positive cells)and its regulatory mechanism.Methods MDA-MB-231 cells were trea-ted with EBSS,Baf-A1,and EBSS+Baf-A1 for four hours,and MCF-7 cells for eight hours.The effects of autophagy on cell proliferation and apoptosis were ob-served,mitochondrial morphology was examined,and the expression of autophagy markers LC3B,P62,LAMP1,TOM20,AMPK,p-AMPK,ULK1,and Bec-lin1/VPS34 proteins was detected.The autophagy pathway was validated by inhibiting AMPK activity.Results Breast cancer cells underwent autophagy af-ter starvation induction(EBSS),with inconsistent au-tophagy processes observed in different subtypes of breast cancer cells.Autophagy inhibited cell prolifera-tion.In MDA-MB-231 cells,autophagy led to an in-crease in p-AMPK levels and a decrease in ULK1 lev-els,initiating autophagy through p-AMPK activation of ULK1.In MCF-7 cells,both p-AMPK and ULK1 levels decreased after autophagy,suggesting that autophagy might not be mediated by p-AMPK activation.Conclu-sions MDA-MB-231 cells primarily initiate autophagy by directly activating ULK1 by p-AMPK,independent of the MTOR pathway.In MCF-7 cells autophagy might be triggered by inhibiting MTOR through AMPK activity or directly activating MTOR through other up-stream factors.Regulating p-AMPK activity based on the autophagy pathways in different cell subtypes could enable more precise targeting and treatment of different types of breast cancer.
9.Construction and identification of a sizeable naive human Fab phage display antibody library
Yakun ZHAO ; Xiaoyue WEI ; Fanliang MENG ; Wentao LIU ; Jiaming FAN ; Lijin LONG ; Wanting WANG ; Jianling CHEN ; Jianzhong ZHANG ; Lihua HE ; Liyong LIU ; Rui ZHAO ; Di SUN ; Xuezhen YUAN ; Xiaomei YAN
Chinese Journal of Epidemiology 2025;46(2):288-295
Objective:To construct a sizeable naive human Fab phage display antibody library to screen high-affinity specific antibodies in vitro. Methods:Total RNA was extracted from peripheral blood mononuclear cells (PBMCs) of 126 healthy individuals, subsequently reverse-transcribed into cDNA, and used as a template. PCR amplification was performed to obtain the V H from IgG, IgM and light chain κ, λ, separately, with the initial PCR products serving as templates for a second round of PCR. Overlap extension PCR was employed to generate fragments of the κ and λ light chains. These fragments were ligated with the phage vector pNC3, which harbors the variable region 1 of the heavy chain, to construct a recombinant phage plasmid. This plasmid was then electroporated into competent Escherichia Coli TG1 cells to establish a naive human Fab phage display antibody library. One hundred clones were randomly selected for identification and sequencing, and antibody gene polymorphisms were analyzed using the IMGT database and MAFFT software. Recombinant α-hemolysin from Staphylococcus aureus was utilized to screen Fab antibody fragments through biopanning of the antibody library, followed by random selection of phage ELISA-identified clones. The positive clones (antigen A450∶blank control A450≥2.1) were sequenced. Results:Two large naive Fab phage display antibody libraries were successfully constructed, in which the capacity of κ and λ chain antibody libraries were 1.25×10 11 and 1.54×10 11, respectively. The titers for two antibody libraries were 6.04×10 13 CFU/ml and 3.50×10 13 CFU/ml. The positive transformation insertion rates for κ and λ chain antibody libraries were 96% (96/100) and 100% (100/100), respectively. Sequence analysis revealed that all antibody sequences were unique. The amino acid sequences in the skeletal region were relatively conserved. In contrast, significant variations in the length of the complementarity determining region (CDR) were found, and the diversity of amino acid sequence of the complementary determining region was high, especially the CDR3. Analysis using the IMGT database indicated that the sequences exhibited a broad distribution across variable-diversity-joining gene families. After six rounds of panning, specific phage antibodies enrichment targeting α-hemolysin were achieved. A total of 142 monoclonal antibodies were sequenced, yielding 8 distinct Fab antibody sequences. Conclusion:This study successfully constructed two naive human Fab phage display antibody libraries with large capacity and good diversity, which can be used for screening human antibodies for serum epidemiology.
10.Fetal heart quantification technology for assessing normal fetal cardiac morphology and function: a prospective cohort study
Qiuyi DI ; Xiangdang LONG ; Jing NING ; Sui YAO ; Qiaorong LI ; Yu ZHUO ; Xuan CHEN ; Longfei SHI
Chinese Journal of Perinatal Medicine 2025;28(3):211-218
Objective:To explore the value of fetal heart quantification technology in assessing the morphology and function of the fetal heart during normal pregnancy.Methods:This prospective cohort study selected normal fetuses from healthy pregnant women who underwent prenatal ultrasound examinations at Hunan Provincial People's Hospital from January 2023 to October 2024. Using the GE Voluson E10 color Doppler diasonography, routine obstetric ultrasound and fetal echocardiography were performed to assess fetal growth and development and to exclude intracardiac and extracardiac malformations. Clear four-chamber view (4CV) dynamic images of the heart showing the endocardium (duration ≥3 s) were collected. Speckle-tracking analysis was performed using fetal heart quantification software. The measured indicators included the global spherical index (GSI), end-diastolic length of the heart (L-ED), end-diastolic width of the heart (W-ED), and the global longitudinal strain (GLS), fractional area change (FAC), and 24-segment spherical index (SI) of the left ventricle (LV) and right ventricle (RV). The cases were divided into five groups based on gestational age at the time of prenatal ultrasound: 20 +0 to 23 +6, 24 +0 to 27 +6, 28 +0 to 31 +6, 32 +0 to 35 +6, and 36 +0 to 40 +6 weeks. One-way analysis of variance, two independent samples t-test, univariate linear regression analysis, and Pearson correlation analysis were used to explore the differences in the above indicators among different gestational age groups and their correlation with gestational age. Results:A total of 200 pregnant women were included in the cohort, four cases were excluded due to poor image quality that prevented accurate tracking and measurement of relevant indicators. Ultimately, 196 cases (20 +0 to 23 +6 weeks 40 cases, 24 +0 to 27 +6 weeks 34 cases, 28 +0 to 31 +6 weeks 41 cases, 32 +0 to 35 +6 weeks 48 cases, and 36 +0 to 40 +6 weeks 33 cases) were included in the study, with a successful image analysis rate of 98.0%. (1) There were statistically significant differences in 4CV L-ED, 4CV W-ED, LV-FAC, and RV-FAC among the groups at 20 +0 to 23 +6, 24 +0 to 27 +6, 28 +0 to 31 +6, 32 +0 to 35 +6, and 36 +0 to 40 +6 weeks [4CV L-ED: 28.0±3.0, 32.6±4.3, 40.9±4.3, 46.7±4.8, 53.1±5.8, F=3.72; 4CV W-ED: 21.9±1.8, 25.1±4.2, 31.7±3.0, 37.4±4.0, 42.0±4.9, F=2.61; LV-FAC: (51.4±8.0)%, (49.0±10.4)%, (47.3±7.3)%, (43.1±7.5)%, (40.7±8.2)%, F=2.94; RV-FAC: (49.9±10.8)%, (46.2±12.0)%, (46.3±8.3)%, (43.2±8.0)%, (41.9±5.6)%, F=3.09; all P<0.05].(2) The size of the normal fetal heart gradually increased with gestational age, while the heart morphology remained relatively stable (4CV L-ED and 4CV W-ED were positively correlated with gestational age, with regression coefficients of 1.313 and 1.325, respectively, both P<0.001;LV-FAC and RV-FAC were negatively correlated with gestational age with regression coefficients of -0.783 and -0.552, respectively, both P<0.001; GSI, LV-GLS and RV-GLS had no correlations with gestational age, all P>0.05). (3) The SI of LV segments 1 to 17 were higher than the SI of the corresponding RV segments, and the SI of RV segments 20-24 were higher than that of the corresponding LV segments (all P<0.001). Conclusion:Fetal heart quantification technology has a certain value in the assessment of fetal cardiac morphology and function.

Result Analysis
Print
Save
E-mail