1.Experimental validation of the accuracy of reported dose-length product values in different CT scanner models
Bin YANG ; Shicai ZHANG ; Xiankai HUO ; Zhenhe LIU ; Pengcheng WANG
Chinese Journal of Radiological Health 2025;34(2):155-160
Objective To evaluate the accuracy of dose-length product (DLP) values in CT dose reports by comparing them with the DLP values measured using a pencil-type ionization chamber. Methods Experiments were conducted using four CT scanners with different detector row numbers from two manufacturers (A and B), along with a head phantom and a pencil-type ionization chamber. Other scanning parameters were fixed, while pairwise combinations of kV and mAs were tested. The DLP values were measured under various scanning conditions using the pencil-type ionization chamber (DLPmeasured) and the corresponding DLP values in CT dose reports were recorded (DLPreported). All data were subjected to statistical analysis. Results Differences were observed between DLPreported and DLPmeasured values. The smallest mean absolute value of ΔDLP was approximately 2.526 mGy·cm observed on the 40-row CT scanner of manufacturer A. There was a difference between the ΔDLPs of the four CT scanners. Both DLPreported and DLPmeasured exhibited a linear relationship with mAs. Conclusion The percentage errors between DLPreported and DLPmeasured values for all four CT scanners were within the national standard tolerance of 15%. DLP values in CT dose reports can serve as a reference for assessing patient radiation dose during scanning. However, for radiation dose-related research, data measured using dosimetric instruments such as pencil-type ionization chamber are recommended.
2.Meta-analysis of the clinical efficacy and safety of Jianwei xiaoshi oral liquid in the treatment of functional dyspepsia in children
Ping RONG ; Guiyun PAN ; Juan WEI ; Tengda LI ; Xilian ZHANG
China Pharmacy 2025;36(7):867-873
OBJECTIVE To evaluate the clinical efficacy and safety of Jianwei xiaoshi oral liquid in the treatment of functional dyspepsia (FD) in children, and provide evidence-based basis for clinical use of the drug. METHODS Retrieved from CNKI, VIP, Wanfang, CBM, Cochrane Library and PubMed, randomized controlled trials (RCTs) about Jianwei xiaoshi oral liquid in the treatment of FD in children were collected from the inception to Apr. 2024. The control group was treated with conventional western drugs (including gastrointestinal motion-promoting, antacids or acid-suppressing drugs), and the trial group was treated with Jianwei xiaoshi oral liquid alone or combined with conventional Western drugs (drug dosage and course of treatment were the same as the control group). Meta-analysis was performed using RevMan 5.3 software after quality evaluation with the Cochrane risk bias assessment tool 6.1. RESULTS Totally 16 literature were employed which included 1 962 patients. The results of meta-analysis showed that the total clinical effective rate of Jianwei xiaoxi oral liquid in the treatment of FD in children of trial group was significantly higher than that of the control group [RR=1.18, 95%CI (1.13, 1.22), P<0.000 01]. In this study, subgroup analysis was conducted on the usage and dosage, course of treatment, and combination or not in trial group, as well as the type of conventional Western drugs. The results showed that the total clinical effective rate of trial group was significantly higher than that of control group; the relief time of abdominal distension and abdominal pain in trial group [MD=-2.54, 95%CI (-3.10, -1.98)], loss of appetite relief time [MD=-2.12, 95%CI (-2.63, -1.61)], nausea and vomiting relief time [MD=-1.70, 95%CI (-2.27, -1.14)], and belching relief time [MD=-1.61, 95%CI (-2.44, -0.78)] were shorter than that of the control group significantly (P<0.05). In addition, compared with control group, the levels of gastrin [SMD=1.63, 95%CI (0.98, 2.29)] and motilin [SMD=2.06, 95%CI (1.58, 2.54)] as well as gastric antral emptying rate [MD=5.99, 95%CI (2.78, 9.21)] in trial group were increased significantly, while the level of somatostatin was decreased significantly [SMD=-1.30, 95%CI (-1.57, -1.02)] (P≤0.000 3). CONCLUSIONS Jianwei xiaoshi oral liquid, whether used alone or in combination with other medications, and regardless of the treatment course or dosage and usage, is effective in treating FD in children, with good safety.
4.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
5.Research Progress of External Ventricular Drainage Catheterization Techniques.
Zhenzhen HAN ; Kunshan YUAN ; Haijun ZHANG
Chinese Journal of Medical Instrumentation 2025;49(3):287-294
Insertion of external ventricular drainage (EVD) is an effective neurosurgical treatment approach. The accuracy of EVD insertion is related to potential complications, and the precise placement of the catheter tip can reduce the incidence of complications. With the progress of medical technology, the research and application of EVD catheterization technology are developing rapidly. This paper reviews the traditional blind catheterization, computed tomography, ultrasound guidance, mixed reality navigation system, laser positioning neural navigation, mobile device neural navigation, stereotactic system, and the visualization technology of the whole process of neuroendoscope assisted ventricle puncture to guide EVD catheterization to provide references for clinical decision-making by medical staff.
Humans
;
Drainage/methods*
;
Catheterization/methods*
;
Cerebral Ventricles/surgery*
6.Advances in Surface Modification Techniques of Ureteral Stents.
Guanjun MA ; Hua XIE ; Chao ZHOU ; Guangtai ZHOU ; Haijun ZHANG
Chinese Journal of Medical Instrumentation 2025;49(4):406-414
The article introduces the formation process of bacterial infection and encrustation on the surface of ureteral stents, elaborates in detail on six surface modification methods for ureteral stents, namely impregnation, spraying, vapor deposition, chemical grafting, self-assembly, and electrospinning, then analyzes the advantages and limitations of each technique during application. Meanwhile, it introduces three commonly used materials for ureteral stents, namely polymers, metals, and biodegradable materials, and further explains the commonly used surface modification methods corresponding to different materials. Looking ahead, with the continuous strengthening of the multi-technology integration trend and the continuous advancement of new material research and development, it is expected that a more ideal ureteral stent can be developed.
Stents
;
Ureter
;
Surface Properties
;
Humans
7.Optimizing blood-brain barrier permeability in KRAS inhibitors: A structure-constrained molecular generation approach.
Xia SHENG ; Yike GUI ; Jie YU ; Yitian WANG ; Zhenghao LI ; Xiaoya ZHANG ; Yuxin XING ; Yuqing WANG ; Zhaojun LI ; Mingyue ZHENG ; Liquan YANG ; Xutong LI
Journal of Pharmaceutical Analysis 2025;15(8):101337-101337
Kirsten rat sarcoma viral oncogene homolog (KRAS) protein inhibitors are a promising class of therapeutics, but research on molecules that effectively penetrate the blood-brain barrier (BBB) remains limited, which is crucial for treating central nervous system (CNS) malignancies. Although molecular generation models have recently advanced drug discovery, they often overlook the complexity of biological and chemical factors, leaving room for improvement. In this study, we present a structure-constrained molecular generation workflow designed to optimize lead compounds for both drug efficacy and drug absorption properties. Our approach utilizes a variational autoencoder (VAE) generative model integrated with reinforcement learning for multi-objective optimization. This method specifically aims to enhance BBB permeability (BBBp) while maintaining high-affinity substructures of KRAS inhibitors. To support this, we incorporate a specialized KRAS BBB predictor based on active learning and an affinity predictor employing comparative learning models. Additionally, we introduce two novel metrics, the knowledge-integrated reproduction score (KIRS) and the composite diversity score (CDS), to assess structural performance and biological relevance. Retrospective validation with KRAS inhibitors, AMG510 and MRTX849, demonstrates the framework's effectiveness in optimizing BBBp and highlights its potential for real-world drug development applications. This study provides a robust framework for accelerating the structural enhancement of lead compounds, advancing the drug development process across diverse targets.
8.Intraseasonal variation in acute health effects of extreme heat: An example using emergency ambulance calls data in Dezhou City, Shandong Province, China
Ya ZHANG ; Shengli YIN ; Weihong YANG ; Yu ZHONG ; Qi ZHAO ; Yongbiao CUI
Journal of Environmental and Occupational Medicine 2024;41(8):849-854
Background Intraseasonal variation in acute health effects of extreme heat remains insufficiently investigated. Emergency ambulance calls (EACs) may offer timely insights into the population's health during such extreme heat events. Objective To analyze intraseasonal variation in the association between extreme heat and hourly EACs during summer in Dezhou City, Shandong Province, China. Methods We collected data on all-cause hourly EACs in Dezhou City from 2021 to 2022 and assigned hourly temperature and humidity data (with a spatial resolution of 0.0625° × 0.0625°) to call addresses. Summer in this study was defined as from June to September each year, with June to July considered as early summer and August to September as late summer. Extreme heat was defined as the 99th percentile of the temperature range during the summer. We employed a time-stratified case-crossover design using conditional logistic regression integrating distributed-lag nonlinear models to compare the association between extreme heat and the risk of hourly EACs in both early and late summer periods. Results A total of
9.Comparative analysis of the CT, clinical, and pathological features of patients with invasive lung adenocarcinoma positive and negative for spread through air spaces
Liwei ZHANG ; Guiping YUAN ; Juanjuan FANG ; Minmin TENG ; Dewei SONG ; Bo YU ; Yuanwei SHAO
Chinese Journal of Radiological Health 2024;33(4):459-465
Objective To investigate the correlations of computed tomography (CT), clinical, and pathological features in patients with invasive lung adenocarcinoma positive and negative for spread through air spaces (STAS). Methods A total of 236 patients with invasive lung adenocarcinoma confirmed by surgery and pathology were selected, including 118 patients in STAS-positive group and 118 patients in STAS-negative group. The clinical data, CT signs, and pathological features of the two groups were collected and analyzed. Results There was a correlation between age and the occurrence of STAS. The age of the positive group was higher than that of the negative group. Smoking history and family history of tumor had no correlation with the occurrence of STAS. CT features signs such as nodule type and shape, tumor-lung interface, lobulation sign, spiculation sign, vacuole/cavity, air-bronchogram, pleural indentation sign, vascular changes, mean diameter of tumor, mean diameter of solid component, and the percentage of tumor solid components were significantly different between patients with and without STAS. The incidence of STAS in patients with solid nodules and partial solid nodules was significantly higher than that in patients with ground glass nodules. Multivariate analysis showed that the percentage of tumor solid components, air-bronchogram sign, lobulation sign, and tumor-lung interface were independent risk factors for predicting the occurrence of STAS. Conclusion The clinical data and CT signs of patients with invasive lung adenocarcinoma are related to the occurrence of STAS. CT signs such as the percentage of tumor solid components, air-bronchogram, lobulation sign, and tumor-lung interface are of great significance to STAS prediction. Our findings provide an important basis for selection of personalized clinical treatment plans.
10.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.

Result Analysis
Print
Save