1.Impact of the LAmbre device on left atrial appendage adjacent structures and left atrium
Zhengdan GE ; Dehong KONG ; Zhenyi GE ; Chunqiang HU ; Xiaochun ZHANG ; Haiyan CHEN ; Daxin ZHOU ; Xianhong SHU ; Cuizhen PAN
Chinese Journal of Ultrasonography 2024;33(2):142-150
Objective:To explore the effects of the LAmbre device and mitral annulus(MA), as well as left atrium(LA) in patients with non-valvular atrial fibrillation(NVAF) after left atrial appendage closure (LAAC) using real-time-three-dimensional transesophageal echocardiography (3D TEE).Methods:Fity-six consecutive patients who underwent LAAC with the LAmbre device in Zhongshan Hospital of Fudan University from June 2019 to March 2023 were retrospectively enrolled, with no or less than moderate mitral regurgitation (MR). All patients underwent pre-operative and follow-up two-and three-dimensional transesophageal echocardiography (2D TEE, 3D TEE) at 60 days after the operation. The quantitative parameters of MA and LA were obtained by offline analysis using QLab 13.0 (Philips Healthcare, Andover, MA). Importantly, mitral annular measurements were made at seven time points throughout the cardiac cycle: early diastole, mid-diastole, late diastole, mitral valve closure, early systole, mid-systole, and late systole, which facilitates constructing the dynamic model of MA to assess the annular morphology and dynamics.Results:The values of AP diameter (APD), AL-PM diameter (ALPMD), 3D annulus circumference (3DAC), 3D annulus area (3DAA) decreased significantly compared with pre-operative values at all time points of the cardiac cycle (all P<0.05), while non-planar angle (NPA) and AH/CD were not apparently changed (all P>0.05 ). Throughout the cardiac cycle, MA showed regular changes, gradually increased in systole with the saddle shape deepened, and gradually decreased in diastole with the saddle shape shallowed.During systole, there was an increase in the rate of change of AP in MA [pre-operative (3.01±2.64)%, post-operative (3.81±3.51)%, P=0.037] after LAAC, with no significant difference in the rate of change of ALPM, 3DAC, and 3DAA.Meanwhile, we observed an evident reduction in LA minimal volume (LAVmin) [pre-operative (78.36±25.16)ml, post-operative (70.73±22.78)ml, P=0.004] and an obvious increase in LA ejection function [pre-operative (22.88±10.09)%, post-operative (31.41±12.28)%, P<0.05] during follow-up. Conclusions:3D TEE can accurately assess the impact of LAAC on the MA and LA. The LAmbre device can affect the morphology of MA, as well as the structure and function of LA, while the change of the dynamics of MA is not so prominent.
2.Clinical Application of automatic delineation in whole breast radiotherapy with simultaneous integrated boost to the medial tumor beds
Che CHEN ; Dehong LUO ; Huangfei YU ; Qin ZHANG ; Xiaochi HU ; Shenghua YU ; Yajun LI
The Journal of Practical Medicine 2024;40(17):2406-2411
Objective To assess the viability and efficacy of employing automated segmentation for whole breast radiotherapy with simultaneous integrated boost to the medial tumor beds,a comparative analysis was conducted on the disparities in geometry,dosimetry,and working time between the auto-segmentation(AS)and manual segmentation(MS)groups.Methods A total of 30 patients with early breast cancer,who had undergone conserving surgery and received hypofractionated radiotherapy with a boost to the medial tumor bed,were enrolled from the First People's Hospital of Zunyi.AccuContour software was used in the AS group to obtain the whole breast planning target volume and cardiopulmonary structure.Geometric differences between AS and MS groups were assessed using Dice similarity coefficient(DSC)and 95%Hausdorff distance(95HD).Subsequently,a comparison was made between the two groups regarding target and cardiopulmonary dosimetry for PlanA and PlanM.Additionally,the time spent by each group was also compared.Results The DSC of PGTV,PTV,lung,and heart were 0.94(0.91,0.96),0.88(0.86,0.91),0.98(0.97,0.98)and 0.94(0.93,0.95),respectively.And the 95 HD(cm)were 0.25(0.20,0.33),0.99(0.56,1.20),0.29(0.25,0.35)and 0.50(0.50,0.59)respectively.The dosimetric results showed that the V95,D95,and Dmean of PGTV and PTV in the AS group were significantly lower than those in the MS group(P<0.05);while the V20 and MLD of the left lung were significantly higher(P<0.05).No significant difference was observed in cardiac dose between the two groups.The mean absolute differences of PGTV and cardiopulmonary dose parameters between the two groups were less than 1 Gy/1%,respec-tively.In terms of work efficiency,the AS approach substantially reduced contouring and planning time with over 70%of cases approved within two days.Conclusions The differences in geometric and dosimetric parameters between the auto-segmentation and manual segmentation groups were found to be negligible for whole breast radiotherapy with medial tumor bed boost patients.It is recommended that the PTV be manually modified prior to plan optimiza-tion,leading to a significant improvement in work efficiency.
3.Research Progress on Application of cGAS-STING Signaling Pathway in Colorectal Cancer
Dehong KONG ; Zilong LIU ; Jianjun HU ; Xun LONG ; Zhuxue ZHANG ; Jiemin LIU
Chinese Journal of Gastroenterology 2024;29(12):737-744
cGAS-STING signaling pathway is a key signaling molecule of innate immune response in vivo,which can recognize exogenous and endogenous dsDNA abnormalities in cytoplasm and promote the release of immune mediators such as interferon(IFN)-1,thus leading to immune response in the body.Recent studies have suggested that the disturbance of cGAS-STING signal is an important factor in the occurrence and development of colorectal cancer,which can promote tumor growth and metastasis.cGAS-STING signaling is also related to intestinal immune response,and the use of this signaling pathway helps to provide a new target for colorectal cancer immunotherapy.This article reviewed the role of cGAS-STING signaling pathway in the occurrence and development of colorectal cancer and the latest research progress,the application of cGAS-STING signaling pathway modulators and their combined therapy in colorectal cancer,and forecast the future research direction of this signaling pathway in the treatment of colorectal cancer.
4.Research Progress on Application of cGAS-STING Signaling Pathway in Colorectal Cancer
Dehong KONG ; Zilong LIU ; Jianjun HU ; Xun LONG ; Zhuxue ZHANG ; Jiemin LIU
Chinese Journal of Gastroenterology 2024;29(12):737-744
cGAS-STING signaling pathway is a key signaling molecule of innate immune response in vivo,which can recognize exogenous and endogenous dsDNA abnormalities in cytoplasm and promote the release of immune mediators such as interferon(IFN)-1,thus leading to immune response in the body.Recent studies have suggested that the disturbance of cGAS-STING signal is an important factor in the occurrence and development of colorectal cancer,which can promote tumor growth and metastasis.cGAS-STING signaling is also related to intestinal immune response,and the use of this signaling pathway helps to provide a new target for colorectal cancer immunotherapy.This article reviewed the role of cGAS-STING signaling pathway in the occurrence and development of colorectal cancer and the latest research progress,the application of cGAS-STING signaling pathway modulators and their combined therapy in colorectal cancer,and forecast the future research direction of this signaling pathway in the treatment of colorectal cancer.
5.Standard for monitoring and evaluation of two-dimensional- and three-dimensional-transesophageal echocardiography during transcatheter tricuspid valve replacement
Cuizhen PAN ; Wei LI ; Daxin ZHOU ; Yuan ZHANG ; Wenzhi PAN ; Shasha CHEN ; Jing SHI ; Haiyan CHEN ; Dehong KONG ; Yu LIU ; Zhenyi GE ; Chunqiang HU ; Kefang GUO ; Xianhong SHU ; Junbo GE
Chinese Journal of Ultrasonography 2023;32(5):449-454
Transcatheter tricuspid valve intervention is the new frontier of interventional cardiology. The LuX-Valve is a radial force-independent orthotopic tricuspid valve replacement device developed in China. The LuX-Valve Plus transcatheter tricuspid valve replacement (TTVR) system is changed from the trans-atrial to the transjugular approach, which further reduces trauma and pulmonary complications compared with the first generation LuX-Valve. The first-in-human study has been completed at Zhongshan Hospital, Fudan University and an exploratory multicentre clinical study is underway. Echocardiography plays an important role in pre-TTVR screening, intraoperative guidance and postoperative evaluation and follow-up, especially two-dimensional transoesophageal echocardiography (2D-TEE) and three-dimensional transoesophageal echocardiography (3D-TEE). However, there is a lack of appropriate intraoperative guidance and assessment protocols. In this study, we briefly described the protocols and imaging considerations for intraoperative 2D-TEE and 3D-TEE to ensure the successful implantation of TTVR.
6.Effect of dynamics of instantaneous flow rate on the quantification of the severity of degenerative mitral regurgitation using M-mode proximal isovelocity surface area
Chunqiang HU ; Zhenyi GE ; Shihai ZHAO ; Fangyan TIAN ; Wei LI ; Lili DONG ; Yongshi WANG ; Dehong KONG ; Fangmin MENG ; Zhengdan GE ; Xianhong SHU ; Cuizhen PAN
Chinese Journal of Ultrasonography 2023;32(7):590-599
Objective:To investigate the effect of instantaneous flow rate on the consistency of diagnostic accuracy of severe degenerative mitral regurgitation (DMR) using proximal isovelocity surface area (PISA).Methods:From June 2019 to June 2021, 75 patients with DMR who underwent echocardiography in Department of Echocardiography of Zhongshan Hospital, Fudan University were prospectively enrolled. The instantaneous flow rate of DMR during the systolic phase was calculated using M-mode PISA(PISA M-mode), and a time-integrated curve was plotted. Regurgitant volume (RVol) and effective regurgitant orifice area (EROA) were calculated by traditional PISA (PISA max), pair PISA (PISA pair), and PISA M-mode, respectively. RVol acquired from cardiac magnetic resonance (CMR) volumetric method in 22 patients of the enrolled patients. The correlation and consistency of RVol acquired between the three PISA methods and CMR were compared. Agreement of diagnostic accuracy of severe mitral regurgitation (sMR) acquired between the three PISA methods and multi-parameter algorithm by American Society of Echocardiography (ASE) was analyzed using Cohen′s Kappa analysis. Results:The curve of instantaneous flow rate of DMR showed unimodal pattern with the peak at mid-late systolic phase. The correlation of RVol acquired between PISA methods and CMR was moderate for PISA max and PISA pair ( r=0.77, 0.80, both P<0.001), whereas PISA M-mode presented strong correlation with CMR ( r=0.87, P<0.001). RVol acquired from PISA max was larger than that of CMR[(69.1±37.1) ml vs (49.0±29.0)ml, P=0.002]. Both PISA max and PISA pair were shown moderate agreement of diagnostic accuracy of sMR with ASE multi-parameters algorithm (RVol: κ=0.496, 0.525, both P<0.001; EROA: κ=0.570, 0.578, both P<0.001), while PISA M-mode presented strong agreement (RVol: κ=0.867 and EROA: κ=0.802, both P<0.001). Conclusions:Based on the unimodal pattern of instantaneous flow rate in patients with DMR, PISA max may significantly overestimate RVol, exposing a significant proportion of patients with DMR to unnecessary MR surgery. PISA M-mode presents better correlation and consistency with CMR on the quantification of RVol compared with PISA max and PISA pair, and may improve the diagnostic accuracy of quantification of sMR using PISA.
7. Comparison of chest CT images between confirmed and suspected cases of COVID-19
Rui HU ; Nan HUANG ; Wen CHEN ; Qiang HE ; Liang ZHAO ; Junhua QIU ; Dehong WU ; Can GUO ; Lin XU
Chinese Journal of Radiology 2020;54(0):E015-E015
Objective:
To explore the value of chest CT features and clinical indexes in the differential diagnosis between suspected COVID-19 with two or more negative nucleic acid tests and confirmed COVID-19.
Methods:
The clinical data and chest CT images of 105 cases withconfirmedCOVID-19 (55 males and 50 females, aged from 2 month to 88 years) and 97 cases with suspected COVID-19(59 males and 38 females, aged from 1 month to 93 years) were analyzed retrospectively in Shiyan Taihe Hospital from January 21 to February 10, 2020.
8.D-dimer predicts early neurological deterioration in ischemic stroke
Xiaoyong XIAO ; Dehong LIU ; Huoyou HU ; Zhe DENG ; Yixuan ZENG ; Siqi LI ; Xiaohua XIAO
International Journal of Cerebrovascular Diseases 2019;27(6):408-412
Objective To investigate the predictive value of D-dimer for early neurological deteriora- tion (END) in patients with acute ischemic stroke. Methods Patients with acute ischemic stroke admitted to the Department of Neurology, the Second People ' s Hospital of Shenzhen between January 2015 and December 2017 were enrolled retrospectively. END was defined as an increase ≥2 in the National Institutes of Health Stroke Scale (NIHSS) score or an increase ≥1 in the motor function score within 7 days after admission compared with the baseline score. Demographics, baseline clinical data, and primary treatment options during hospitalization were compared between the END group and the non-END groups. Multivariate logistic regression analysis was used to determine the independent risk factors for END. Receiver operating characteristic (ROC) curve was used to analyze the predictive value of D-dimer for END. Results A total of 625 patients were enrolled in the study, including 40 in the END group (including 3 deaths) and 585 in the non-END group. The mean hospital stay, international normalized ratio, D-dimer, uric acid, NIHSS score and modified Rankin Scale (mRS) score at admission, and the proportion of patients with complete anterior circulation infarction, large atherosclerotic stroke, and pulmonary infection were significantly higher than those in the non-END group (all P < 0. 05). There was no significant difference in the proportion of patients receiving thrombolysis, antiplatelet,anticoagulation, and statins between the two groups. ROC curve analysis showed that the area under the curve of D-dimer predicting END was 0. 810 (95% confidence interval [CI] 0. 736-0. 884; P < 0. 001); the optimal cut-off value was 2. 35 mg/L, and the sensitivity and specificity were 54. 74% and 96. 13% respectively. Multivariate logistic regression analysis showed that large atherosclerotic stroke (odds ratio [OR] 1. 115, 95% CI 1. 005-1. 390; P = 0. 003 ), D-dimer ≥2. 35 mg/L (OR 1. 055,95% CI 1. 012-1. 150; P = 0. 001 ), NIHSS score at admission (OR 1. 191, 95% CI 1. 006-1. 410; P <0. 001), mRS score > 1 at admission (OR 1. 755, 95% CI 1. 139-3. 656; P = 0. 037 ), and pulmonary infection (OR 2. 598, 95% CI 1. 132-3. 081; P = 0. 012) were the independent risk factors for END in patients with acute ischemic stroke. Conclusion D-dimer ≥2. 35 mg/L at admission has higher predictive value for END in patients with acute ischemic stroke.
9.Patient positioning, port placements setting and robot cart docking in pediatric robot-assisted laparoscopic upper urinary tract operation
Xianghua XIONG ; Huixia ZHOU ; Hualin CAO ; Lifei MA ; Dehong LIU ; Xiaoguang ZHOU ; Tian TAO ; Rui WANG ; Zhifang WANG ; Xiaoling HU ; Xuemei HAO ; Xiaojun WANG ; Wei LI ; Xiaoyu LONG
Chinese Journal of Urology 2018;39(8):601-605
Objective To summarize the experience of patient positing,port placements setting and robot cart docking in pediatric robot-assisted laparoscopic upper urinary tract operations.Methods From March 2017 to December 2017,140 robot-assisted laparoscopic upper urinary tract procedures were performed in our institution,including 110 cases of pyeloplasty,15 upper pole heminephroureterectomy,12 simple nephrectomy and 3 adrenalectomy.There were 103 males and 37 females with a range age from 1 month to 18 years.The assistant surgeon was adjacent to the instrument nurse,and patients were placed in a supine position with 60°-80° inclination and keep the legs low to the body.Room setup and patient positioning were similar to the traditional laparoscopic surgery.Semi-hidden incision technique was used in 140 patients:the camera port was placed umbilicus,two additional arm ports (one 5 mm and one 8 mm) were placed under direct vision,the 8 mm arm port was placed on the line of a Pfannenstiel incision and the 5 mm arm port was placed below the Xiphoid along the midline.Finally,a 3 or 5 mm assistant port was placed approximately 3 cm lateral to the inferior arm port,the line of a Pfannenstiel incision.Results The average time was (11.5 ± 3.2) min (10.5-16.5 min) from skin incision to robot cart docking completed.All surgeries were successfully completed without open conversion.One patient required an additional assist port for severe adhesion after the previously open surgery,there was no injury to other viscera.Average operative time was (146.9 ± 48.7)min (78-259 min) and average post-operative hospitalization time was (5.7 ± 1.4) d(4-10 d),respectively.There was no visual scar on abdominal 6 weeks postoperatively,and all parents made comments about their satisfaction with the cosmetic appearance.All operations got complete success at a mean follow up of 6 (1-9) months.Conclusions A good room setup,patient positioning and the semi-hidden incision technique port placements are maintaining the safety of the patient,avoiding compression injuries,allowing maximum mobility of the robotic arms,and facilitating a smooth and efficient surgery,and improving post-operative recovery.
10.Study on HPLC fingerprint of radix euphorbiae fischerianae
International Journal of Laboratory Medicine 2016;37(4):447-448,451
Objective To establish fingerprint of Radix Euphorbiae Fischerianae by high performance liquid chromatography (HPLC) .Methods The samples were separated on Hypersil ODS(250 mm × 4 .6 mm ,5 μm) column with gradient mobile phase of acetic-water ,the column temperature was 20 ℃ with the flow rate of 1 .0 mL/min and UV detection wavelength was 210 nm .the sample injection was 20 μL .Results 15 samples of different origin Radix Euphorbiae Fischerianae were detected and each chroma-tographic peak was separated well with conforming to the requirements of fingerprint by calibrating the 15 peaks .15 common peak retention time RSD ,relative peak area RSD were 3 .7% ,3 .6% or less respectively ;The chromatographic peak separation degree was better ,similarity was higher ,15 batches of different sources of stellera medicinal materials ,in addition to the Guangxi nanning medi-cine material similarity was 0 .858 ,other origin medicine material similarity above 0 .95 .Have reached the technical requirements of traditional Chinese medicine (TCM ) fingerprint .Conclusion The method is accurate ,reliable ,and the HPLC fingerprint shows good repeatability ,which can be used for one of the quality control of Radix Euphorbiae Fischerianae .

Result Analysis
Print
Save
E-mail