1.Analysis of Genetic Test Results and Red Blood Cell Parameters of β-Thalassemia in Kunming Area.
Xiao-Lu GUO ; Ya-Min WU ; Yan-Liang ZHANG
Journal of Experimental Hematology 2025;33(2):481-485
OBJECTIVE:
To investigate the gene carrier rate and genotype distribution characteristics of thalassemia in the population of Kunming, and compare the differences of red blood cell (RBC) parameters between β+ heterozygous carriers, β0 heterozygous carriers and healthy population, as well as between different sexes of adults aged 18-45 years.
METHODS:
A retrospective analysis of 3 195 cases of thalassemia gene screened in the First Affiliated Hospital of Kunming Medical University from April 1, 2020 to March 31, 2022 was performed to detect 21 mutations of β-globin genes which was common in Chinese people using fluorescence PCR melting curve method. Patients with single heterozygous carrying β-thalassemia gene were divided into β+ heterozygote group and β0 heterozygote group, while the control group consisted of 219 healthy individuals. Four indices, including RBC, hemoglobin (Hb), mean corpuscular volume (MCV), and mean corpuscular hemoglobin (MCH) were collected from all β heterozygous carriers and 219 healthy people, and compared between β+ heterozygote group, β0 heterozygote group and control group, as well as between β+ heterozygous carriers, β0 heterozygous carriers and healthy population of different sexes aged 18-45 years.
RESULTS:
There were 688 cases confirmed thalassemia gene carriers, accounting for 21.53%. Among them, 322 cases were found to have β-globin gene mutations, including 145 cases of β+ heterozygote, 151 cases of β0 heterozygote, and 14 cases of β+ homozygotes as well as β+ and β0 dual heterozygotes. Additionally, 12 cases were found to have simultaneous mutation or deletion of β-globin and α-globin. The carrier rate of CD26 G>A mutation in β+ thalassemia was the highest, accounting for 57.9%, while in β0 thalassemia CD17 A>T was the highest, accounting for 46.4%. The erythrocyte parameters of 296 β heterozygous mutation carriers were compared with the normal reference interval, and it was found that 218 cases with RBC value greater than the highest value of reference interval, while 105, 281, and 269 cases with Hb, MCV, and MCH value less than the lowest value of reference interval, respectively. There were significant differences in the 4 erythrocyte parameters between β+ heterozygotes, β0 heterozygotes and healthy individuals (all P < 0.001), and further comparison between different sexes also showed significant differences (all P < 0.001).
CONCLUSIONS
The carrier rates of thalassemia gene and β-thalassemia heterozygote are both at high level in Kunming, and there are significant differences in the erythrocyte parameters between β+ heterozygous carriers, β0 heterozygous carriers and healthy individuals. When genetic counseling, it is necessary to inform and strengthen screening among adults of marriageable age to prevent birth of children with severe thalassemia.
Humans
;
beta-Thalassemia/blood*
;
Adult
;
Heterozygote
;
Male
;
Female
;
beta-Globins/genetics*
;
Retrospective Studies
;
Middle Aged
;
Mutation
;
Adolescent
;
Genotype
;
Erythrocytes
;
Erythrocyte Indices
;
Young Adult
;
China
;
Genetic Testing
;
Asian People/genetics*
2.Construction and finite element analysis of normal and osteoporotic hip models
Sutong GUO ; Dehong FENG ; Yu GUO ; Ling WANG ; Yujian DING ; Yi LIU ; Zhengying QIAN ; Mingyang LI
Chinese Journal of Tissue Engineering Research 2024;28(9):1342-1346
BACKGROUND:Bone mineral density is the clinical gold standard for determining bone strength,but bone mineral density is less sensitive to changes in bone mass,with large changes in bone mineral density only occurring when bone mass is significantly reduced,so bone mineral density has limited ability to predict changes in bone strength and fracture risk. OBJECTIVE:A model of the normal and osteoporotic hip joint was developed to analyze the stresses and deformation in the hip of normal and osteoporotic patients under single-leg standing conditions. METHODS:A healthy adult female volunteer at the age of 36 years was selected as the study subject.The CT data of the hip joint of this volunteer were obtained and saved in DICOM format.The hip joint model was reconstructed in three dimensions,and the material properties were assigned by the gray value assignment method to obtain the normal and osteoporotic hip joint models according to the empirical formula.The same boundary conditions and loads were set to simulate the stresses and deformation in the normal and osteoporotic hip joints in the single-leg standing position. RESULTS AND CONCLUSION:(1)In the finite element model of the normal and osteoporotic hip,the stress distribution was more concentrated in the medial region of the femoral neck.(2)In the hip bone,the stress distribution was mainly concentrated in the upper part of the acetabulum.(3)The stress peaks in the medial femoral neck and upper acetabulum were larger in the normal hip model than in the osteoporotic hip model,probably due to the reduced bone strength of the osteoporotic bone.(4)The peak Von Mises of both normal and osteoporotic hip models were concentrated on the medial femoral neck,and the peak Von Mises of the hip bone was smaller,indicating that the overall effect of osteoporosis on hip bone stresses was relatively small.(5)In terms of deformation in the single-leg standing position,the maximum deformation in the normal hip model was located at the acetabulum and femoral head,and the maximum deformation was located at the upper part of the greater trochanter of the femur.(6)It is suggested that the finite element analysis method to model the values of parameters related to bone tissue in osteoporosis may improve clinical prediction of bone strength changes and fracture risk.It is explained from the biomechanical view that the intertrochanteric femur and femoral neck are good sites for osteoporotic hip fractures.
3.Standard for monitoring and evaluation of two-dimensional- and three-dimensional-transesophageal echocardiography during transcatheter tricuspid valve replacement
Cuizhen PAN ; Wei LI ; Daxin ZHOU ; Yuan ZHANG ; Wenzhi PAN ; Shasha CHEN ; Jing SHI ; Haiyan CHEN ; Dehong KONG ; Yu LIU ; Zhenyi GE ; Chunqiang HU ; Kefang GUO ; Xianhong SHU ; Junbo GE
Chinese Journal of Ultrasonography 2023;32(5):449-454
Transcatheter tricuspid valve intervention is the new frontier of interventional cardiology. The LuX-Valve is a radial force-independent orthotopic tricuspid valve replacement device developed in China. The LuX-Valve Plus transcatheter tricuspid valve replacement (TTVR) system is changed from the trans-atrial to the transjugular approach, which further reduces trauma and pulmonary complications compared with the first generation LuX-Valve. The first-in-human study has been completed at Zhongshan Hospital, Fudan University and an exploratory multicentre clinical study is underway. Echocardiography plays an important role in pre-TTVR screening, intraoperative guidance and postoperative evaluation and follow-up, especially two-dimensional transoesophageal echocardiography (2D-TEE) and three-dimensional transoesophageal echocardiography (3D-TEE). However, there is a lack of appropriate intraoperative guidance and assessment protocols. In this study, we briefly described the protocols and imaging considerations for intraoperative 2D-TEE and 3D-TEE to ensure the successful implantation of TTVR.
4.Digital design and 3D-printed customized flanged cups in hip revision with severe acetabular bone defects
Yujian DING ; Dehong FENG ; Ling WANG ; Yu GUO ; Yi LIU ; Yiyi ZHOU ; Sutong GUO ; Zhengying QIAN ; Kuixue XU ; Zhaofeng ZHANG
Chinese Journal of Orthopaedics 2023;43(2):97-103
Objective:To investigate the effect of 3D-printed customized flanged cup in hip revision with severe acetabular bone defects.Methods:Since February 2017, 10 cases of 3D-printed customized flanged cups were used in hip revision with severe acetabular bone defects, including 2 cases of Paprosky type IIIA and 8 cases of Paprosky type IIIB. There were 5 males and 5 females, mean age 73.6±8.1 yrs (range, 62-87 yrs), 5 left and 5 right cases. The preoperative thin-layer CT scan was preformed to reverse reconstruct digital pelvis. Five cases of one-piece flanged cups and 5 cases of decomposed flanged cups, including 3 cases of composite one-piece cups were designed by computer. The surgery was performed strictly according to the plan.Postoperative follow-up was performed to evaluate the Harris score. Operation time,intraoperative bleeding and other complications such as vascular and nerve injury, postoperative infection, and dislocation were counted. Pelvic X-ray was used to assess the height and horizontal position of the center of rotation and the stability of the prosthesis.Results:The surgical procedure was successful, with an average operative time of 147.9±48.3 min (range, 96-212 min) and an average intraoperative bleeding of 730.4±262.6 ml (range, 500-1 300 ml). The mean time of final follow-up was 40.8±18.7 months (range, 16-70 months) after surgery. At the last follow-up, the average Harris score was 83.80±6.73, with 4 cases excellent, 5 cases good, and 1 case fair. The excellent and good rate was 90%. The last Harris score was significantly higher than that before operation 28.60±8.40 ( t=16.84, P<0.001). The height of affected hip joint rotation center decreased from 46.24±7.74 mm before operation to 15.54±2.54 mm after operation with significant difference ( t=14.61, P<0.001). It was slightly higher than the opposite side (13.81±1.48 mm), which had no significant difference ( t=1.83, P=0.100). The horizontal distance of affected hip joint rotation center increased from 33.79±5.27 mm before operation to 40.53±4.50 mm after operation with significant difference ( t=3.62, P=0.006). It had no significant difference ( t=1.28, P=0.232) compared with the opposite side (38.54±3.46 mm). All incisions were healed in one stage without infection, vascular or nerve injury. During the following-up, all prostheses were in satisfied position without loosening, dislocation or screw breaks. Conclusion:Digitally assisted 3D-printed flanged cups can be used in hip revision with severe acetabular bone defect. It can not only improve hip joint function, but also restore the acetabular rotation center and the prosthesis stability, which can achieve good early and mid-term effect.
5.Three-dimensional printing technology in reverse shoulder arthroplasty after resection of proximal humeral tumors
Yu GUO ; Dehong FENG ; Ling WANG ; Yujian DING ; Yi LIU ; Junshan HE
Chinese Journal of Orthopaedics 2023;43(9):559-566
Objective:To analyze the efficacy of the reconstruction of the proximal humerus by reverse shoulder arthroplasty with three-dimensional (3D) printing technology after tumor rescetion.Methods:A retrospective analysis was conducted on the data of eight patients undergoing semi-constrained reverse shoulder arthroplasty with 3D printing technology after the resection of bone tumors in proximal humeri at the Affiliated Wuxi People's Hospital of Nanjing Medical University from December 2017 to January 2021. There were four males and four females with an average age of 55.1 (range, 31-73) years, all of whom had unilateral onset, 2 on the left and 6 on the right. There was one case of leiomyosarcoma (Enneking IIB), two cases of chondrosarcomas (one Enneking IA and one Enneking IB), four cases of Campanacci grade 3 giant cell tumor of bone, and one case of bone metastasis of lung adenocarcinoma. Individualized prosthesis and implantation protocol were completed preoperatively in all patients. The glenoid baseplate was manufactured using 3D printing technology. During the surgery, Malawer type I tumor resection and semi-constrained reverse shoulder arthroplasty were performed, with 6 cases simultaneously using allograft-prosthetic composite reconstruction. The follow-up was scheduled, and the patient received X-ray examination of the shoulder. The range of motion of the shoulder was measured, the Constant-Murley score and musculoskeletal tumor society (MSTS) score were recorded.Results:All 8 patients successfully completed the surgery, with a surgical time of 173.8±46.7 min (range, 130-260 min), intraoperative blood loss of 487.5±334.6 ml (range 200-1,200 ml), and proximal humeral resection of 9.9±4.6 cm (range, 4.5-19.0 cm). All patients were followed up for a period of 45.6±12.5 months (range, 24-60 months). At the last follow-up, the abduction ranges of motion of the affected shoulders increased from 27.5°±14.4° pre-operatively to 106.3°±21.8° post-operatively, with a statistically significant difference ( t=11.37, P<0.001). The forward flexion ranges increased from 28.1°±12.8° pre-operatively to 115.6°±24.0° post-operatively, with a statistically significant difference ( t=11.49, P<0.001). The Constant-Murley score was improved from 40.5±14.3 pre-operatively to 79.3±11.2 post-operatively, with a statistically significant difference ( t=9.58, P<0.001). The MSTS score was 25.6±2.2 (range, 23-28), including 6 excellent cases and 2 good cases. At 2 weeks after surgery, one patient experienced joint dislocation that was successfully reduced manually. Up to the final follow-up, all patients had survived without local tumor recurrence, metastasis, prosthesis infection and loosening. Conclusion:3D printing technology assisted shoulder arthroplasty is helpful for effective reconstruction and shoulder joint function recovery after resection of proximal humeral tumors, with satisfactory outcomes in the early and middle stages.
6.Epidemiological analysis of animal plague in natural plague focus of Himalayan Marmot in Yumen City of Gansu Province from 2014 to 2021
Dehong LI ; Liang CAO ; Liang GUO ; Fachang JIN ; Yang ZHANG ; Debiao LI
Chinese Journal of Endemiology 2022;41(9):729-732
Objective:To learn about the epidemic law of animal plague in natural plague focus of Himalayan Marmot in Yumen City of Gansu Province, to explore the epidemiological characteristics of plague in the area and to provide scientific basis for formulating prevention and control strategies of the plague. Methods:The animal plague surveillance data of natural plague focus of Himalayan Marmot in Yumen City, Gansu Province from 2014 to 2021 were collected, main host density, rate of infected with fleas, flea index, small rodent species, bacteriology, serology were studied. Excel 2007 software was used to analyze the plague epidemic situation in the focus. Results:From 2014 to 2021, the total average density was 0.06 per hm 2 of the marmots. A total of 19 300 traps were placed, and 209 rats were caught, with an average catch rate of 1.08%. Among them, Dipus sagitta (59.81%, 125/209) and Mongolian Five-toed Jerboa(31.10%, 65/209) were dominant small rodent species. Totally 877 marmots were checked, 184 with flea. The rate of infected with fleas of marmots was 20.98%, with a flea index of 1.00, Callopsylla dolabris (52.69%, 461/875) and Oropsylla silantiewi (47.20%, 413/875) were dominant species in vector. The rate of infected with fleas of burrow was 7.72% (173/2 241), with a flea index of 0.20. A total of 39 strains of Yersinia pestis were isolated from infected animals. Among them, 35 strains from the marmots, and 4 strains from vectors. Totally 913 serum samples were checked from marmots and shepherd dog, the positive serum was 34. Among them, the positive rate of shepherd dog was 13.98% (33/236). Conclusions:The plague epidemic situation in natural plague focus of Himalayan Marmot in Yumen City of Gansu Province is still serious. The monitoring of plague should be strengthened, and the comprehensive measures for prevention and control of the plague should be carried out to prevent a outbreak of the plague in human being.
7.Real-time monitoring and step-by-step guidance for transcatheter tricuspid annuloplasty using transesophageal echocardiography
Cuizhen PAN ; Daxin ZHOU ; Xiaochun ZHANG ; Wei LI ; Shasha CHEN ; Yuan ZHANG ; Jing SHI ; Haiyan CHEN ; Dehong KONG ; Yu LIU ; Zhenyi GE ; Kefang GUO ; Xianhong SHU ; Junbo GE
Chinese Journal of Ultrasonography 2022;31(7):626-630
Tricuspid regurgitation (TR) interventions are under rapid development. The K-Clip? system is the first domestic transcatheter tricuspid annuloplasty system with unique clamping procedure to achieve annular reduction.Intraoperative echocardiographic monitoring procedures for transcatheter tricuspid annuloplasty have not been reported yet in China. Thus, this review aimed to propose the standard two-dimensional and three-dimensional transesophageal echocardiographic workplanes and procedures to guide and monitor the implantation of K-Clip system based on our experience in Zhongshan Hospital, Fudan University to provide a reference point for the intraoperative echocardiographic monitoring of future transcatheter tricuspid annuloplasty devices in China.
8.The review of inspection methods of X-ray lead protective clothing
Xuan ZHANG ; Mengfei LI ; Dehong LI ; Jianwei HUANG ; Bin GUO
Chinese Journal of Radiological Medicine and Protection 2021;41(6):475-479
The quality evaluation of X-ray protective clothing at home and abroad is mainly intended for the quality inspection of lead protective clothing. There is no unified standard to be developed for the test of lead protective clothing during use. When lead protective clothing with defective quality is used many times, this phenomenon will pose a greater safety hazard to radiation workers and patients. Therefore, in order to protect the health of radiation workers and patients, the implementation of regular testing and quality evaluation of lead protective clothing and the development of a standardized management system are important. This review introduces the domestic and international inspection method of X-ray lead protective clothing, summarizes the inspection and evaluation method in use, including shield transmission coefficient, defect detection and uniformity test, puts forward relevant suggestions to provide reference for the managers and practitioners of relevant institutions.
9.Emerging infectious diseases in voluntary blood donors in parts of China: Based on metagenomics analysis
Yuhui LI ; Zhan GAO ; Shilin LI ; Yujia LI ; Yang HUANG ; Limin CHEN ; Mei HUANG ; Jianhua WAN ; Weilan HE ; Wei MAO ; Jie CAI ; Jingyu ZHOU ; Ru YANG ; Yijing YIN ; Yanli GUO ; Miao HE
Chinese Journal of Blood Transfusion 2021;34(5):440-446
【Objective】 To analyze the metagenomics and microbiology of voluntary blood donors in China, so as to assess the potential threats of emerging infectious diseases to the safety of blood transfusion. 【Methods】 12 300 plasma samples (10 mL each) collected by central blood stations in Chongqing, Liuzhou, Urumqi, Mianyang, Wuhan, Nanjing, Mudanjiang, and Dehong Prefecture area from 2012 to 2018 were subjected to total DNA extraction after ultracentrifugation (32 000 rpm/min, centrifugal radius 91.9 mm) in minipools of 160 donations. The metagenomic library was constructed, and deep sequencing was conducted by Illumina Hiseq 4 500. By comparing with reference sequences of bacteria, fungi, parasites and viruses, metagenomic data were analyzed, classification of microbes were identified, and potentially harmful pathogens were evaluated. 【Results】 A total of 632 GB clean data were obtained by deep sequencing, and the top three pathogens were Pseudomonas(0.561 1%), Burkholderia(0.468 7%) and Serratia(4.242 0%). Pathogens with potential threat which could be transmitted by blood transfusion or blood products were found, such as human parvovirus B19(0.126 6%), Leishmania spp(1.348 5%) and Toxoplasma gondii(0.615 8%). 【Conclusion】 Our study analyzed metagenomics of voluntary blood donors in parts of China and revealed pathogens that may cause potential harm to blood safety, which were helpful for targeted prevention and control of emerging infectious diseases.
10. Comparison of chest CT images between confirmed and suspected cases of COVID-19
Rui HU ; Nan HUANG ; Wen CHEN ; Qiang HE ; Liang ZHAO ; Junhua QIU ; Dehong WU ; Can GUO ; Lin XU
Chinese Journal of Radiology 2020;54(0):E015-E015
Objective:
To explore the value of chest CT features and clinical indexes in the differential diagnosis between suspected COVID-19 with two or more negative nucleic acid tests and confirmed COVID-19.
Methods:
The clinical data and chest CT images of 105 cases withconfirmedCOVID-19 (55 males and 50 females, aged from 2 month to 88 years) and 97 cases with suspected COVID-19(59 males and 38 females, aged from 1 month to 93 years) were analyzed retrospectively in Shiyan Taihe Hospital from January 21 to February 10, 2020.

Result Analysis
Print
Save
E-mail