1.Insomnia and quality of life as chain mediators between negative life events and depression severity in adolescents with depressive disorders
Xu ZHANG ; Lewei LIU ; Jiawei WANG ; Feng GENG ; Daming MO ; Changhao CHEN ; Zhiwei LIU ; Xiangwang WEN ; Xiangfen LUO ; Huanzhong LIU
Acta Universitatis Medicinalis Anhui 2026;61(1):163-168
ObjectiveTo explore the relationship between negative life events and depression severity in adolescent patients with depressive disorder, as well as the chain mediating role of insomnia symptoms and quality of life. Methods374 outpatient patients and hospitalized patients with adolescent depressive disorders were enrolled. The Adolescent Life Event Scale (ASLEC), the Insomnia Severity Index (ISI), the World Health Organization Quality of Life Questionnaire Short Form (WHOQOL-BREF), and the Center for Epidemiology Depression Scale (CES-D) were used to evaluate the negative life event situation, insomnia symptoms, quality of life level and depression severity of the subjects, respectively. In addition, the PROCESS 4.0 macroprogram was used to analyze the chain mediating effect of insomnia symptoms and quality of life between negative life events and depression severity in patients with adolescent depressive disorder. ResultsThe results of correlation analysis showed that there was a significant correlation between negative life events and insomnia symptoms, quality of life, and depression severity (all P<0.05). In addition, the results of chain mediation showed that negative life events had a significant direct effect on depression severity, with an effect size of 0.12 (P<0.001). Insomnia symptoms and quality of life played a mediating role in the relationship between negative life events and depression severity in patients with adolescent depressive disorders, with indirect effect sizes of 0.062 (95%CI: 0.040-0.087) and 0.091 (95%CI: 0.059-0.123), respectively. It could also play a chain mediation role, and the effect size was 0.039 (95%CI: 0.024-0.057). ConclusionNegative life events experienced by patients with adolescent depressive disorder not only directly affect the severity of depressive symptoms, but may also indirectly exacerbate depression through insomnia symptoms and quality of life.
2.Preliminary study on the effect of the third generation flow diverter device in the treatment of intracranial aneurysms
Xiaoliang YIN ; Jun YANG ; Tao WANG ; Xiaodong CHEN ; Peng LIU ; Daming WANG
Chinese Journal of Surgery 2025;63(3):233-239
Objective:To investigate the clinical effect of the third diverter device in the treatment of intracranial aneurysms.Methods:This is a retrospective case series study. A retrospective study was conducted on patients with intracranial aneurysms treated with the new flow-diverting device at the Department of Neurosurgery, Peking University Third Hospital from March 2023 to February 2024. There were 11 males and 27 females, aged (58.6±12.9) years (range: 27 to 82 years). All patients underwent digital subtraction angiography(DSA) at the time of surgery to observe the stent position, wall apposition. The degree of aneurysm embolization was evaluated using the O′Kelly-Marotta (OKM) grading system,with OKM grade D as complete occlusion. The incidence of perioperative intracranial hemorrhagic and ischemic complications was recorded. The modified Rankin scale (mRS) was used to assess patients′ neurological function at discharge. CT angiography and DSA were performed 6 to 12 months postoperatively to evaluate the stent position and aneurysm embolization.Results:A total of 38 patients with 39 intracranial aneurysms were treated using 40 stents, with coil embolization applied to 6 aneurysms. No ischemic or hemorrhagic events occurred during the perioperative period. At discharge, all patients had an mRS score of 0. During follow-up, one patient with an ophthalmic artery segment aneurysm experienced transient monocular blindness. Imaging follow-up by DSA showed that the complete aneurysm occlusion rate was 89.7%(35/39) at 6 months and 96.8%(30/31) at 12 months.Conclusion:The flow-diverting device demonstrates a low complication rate and a high aneurysm occlusion rate, which is a clinically optional treatment approach.
3.Mechanical thrombectomy:recent advancement of the clinical trials
Ximeng YANG ; Jun LU ; Junjie WANG ; Daming WANG
Chinese Journal of Surgery 2025;63(3):203-207
Mechanical thrombectomy has become the first choice for the treatment of acute ischemic stroke caused by large vessel occlusion since 2015. Over the past decade, on the basis of early clinical practice and research,mechanical thrombectomy has advanced rapidly, not only in expanding the therapeutic time window for mechanical thrombectomy but also in the necessity of bridging therapy, the benefits for patients with large infarct cores, basilar artery thrombectomy, thrombectomy for medium vessel occlusion, and the choice of thrombectomy methods. In the future, mechanical thrombectomy will bring benefits to more patients with ischemic stroke,through persistently explore, expanding the indications of mechanical thrombectomy, continuously optimizing patient selection, and improving the recanalization rate.
4.Finite element analysis of a novel lumbar facet joint fusion device
Feilong SUN ; Haiyang QIU ; Yufei JI ; Yipeng YANG ; Daming LIU ; Longchao WANG ; Fei WANG ; Wei LEI ; Yang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(15):3081-3088
BACKGROUND:Facet joint osteoarthritis is acknowledged as a significant contributor to lower back pain in the geriatric population.The advent of an innovative spinal facet joint fusion device presents a therapeutic option for intervening during the initial stages of facet joint osteoarthritis,and significantly reduces the incidence of a series of complications caused by poor early conservative treatment and late surgical treatment.However,its effect on the biomechanics of the lumbar spine is unknown.OBJECTIVE:To investigate the biomechanical disparities between the novel lumbar zygapophyseal joint fusion device and traditional fusion devices.METHODS:A comprehensive three-dimensional finite element model of the L3-S1 lumbar spine was established and validated.Based on this intact model,three groups of surgical models were constructed:a bilateral pedicle screw fixation model,a bilateral novel facet joint fusion fixation model,and a bilateral facet screw fixation model,with the surgical segment designated as L4-5.Under a load of 500 N,a torque of 7.5 Nm was applied to all lumbar models to calculate the range of motion,displacement values,and intervertebral disc stress values at the L4-5 segment;stress values at the L3-4 and L5-S1 segments were also measured.RESULTS AND CONCLUSION:(1)Compared with the intact model,the range of motion at the L4-5 segment was reduced in all surgical models.(2)The novel device exhibited the smallest range of motion at the L4-5 segment under left and right rotational conditions;the greatest range of motion at the L4-5 segment under extension conditions;and a greater range of motion under other conditions than the bilateral pedicle screw fixation model.(3)The novel device demonstrated the smallest displacement values at the L4-5 segment under left and right rotational conditions;under other conditions,the displacement values at the L4-5 segment were greater than those in the bilateral pedicle screw fixation model.(4)In terms of stress distribution at the L4-5 segment,the novel device consistently exhibited the smallest values across all conditions.(5)For the L3-4 segment,the novel device showed the greatest stress values under extension and left and right rotational conditions,while under other conditions,the values were lower than those in the bilateral pedicle screw fixation model.(6)Compared with pedicle screw fixation,the novel device produced smaller stress values at the L5-S1 segment.(7)This study indicates that,compared with pedicle screw fixation,the novel device impacts the biomechanics of the lumbar spine by fusing the facet joints.It provides stability while preserving the range of motion at the surgical segment and reduces stress on the intervertebral discs of the surgical and adjacent segments,thereby potentially delaying disc degeneration.This suggests that the novel device can achieve biomechanical effects similar to those of pedicle screw fixation in theory.
6.Ultrasound radiomics combined with machine learning for early diagnosis of seronegative hashimoto’s thyroiditis
Wenjun WU ; Chang LIU ; Shengsheng YAO ; Daming LIU ; Yuan LUO ; Yihan SUN ; Ting RUAN ; Mengyou LIU ; Li SHI ; Mingming XIAO ; Qi ZHANG ; Zhengshuai LIU ; Xingai JU ; Jiahao WANG ; Xiang FEI ; Li LU ; Yang GAO ; Ying ZHANG ; Liying GONG ; Xuanyu CHEN ; Wanli ZHENG ; Xiali NIU ; Xiao YANG ; Huimei CAO ; Shijie CHANG ; Zuoxin MA ; Jianchun CUI
Chinese Journal of Endocrine Surgery 2025;19(3):313-319
Objective:To evaluate the value of ultrasound radiomics combined with machine learning for early diagnosis of seronegative Hashimoto’s thyroiditis (SN-HT) .Methods:This retrospective study included 164 patients from Liaoning Provincial People’s Hospital , Lixin County People’s Hospital, Linghai Dalinghe Hospital, Fengcheng Phoenix Hospital, who underwent thyroidectomy for solitary nodules with normal thyroid function between Nov. 2016 and Jan. 2024. Postoperative pathology confirmed Hashimoto’s thyroiditis (HT) in some cases, who were further categorized into antibody-positive and antibody-negative groups based on serum antibody status. Patients without Hashimoto’s thyroiditis served as the control group. A total of 298 ultrasound images were analyzed. Radiomics features were extracted from hypoechoic non-nodular areas within 0.5 cm surrounding the tumor. Two senior pathologists and two senior ultrasound physicians independently assessed lymphocytic infiltration, eosinophilic changes of follicular epithelium, and the proportion of hypoechoic areas in pathology and ultrasound images, respectively. A machine learning model, CCH-NET, was developed using linear regression and t-distributed stochastic neighbor embedding (t-SNE) techniques. The dataset was divided into a training set (80%) and a validation set (20%) to compare the diagnostic accuracy of CCH-NET with that of senior ultrasound physicians. Results:In internal validation, CCH-NET achieved a diagnostic accuracy of 88.89% for both antibody-positive and antibody-negative groups, significantly higher than the 66.67% accuracy of senior ultrasound physicians ( P<0.01). In external validation, CCH-NET achieved 75.00% and 66.67% accuracy for the two groups, compared to 50.00% by senior ultrasound physicians. For the control group, both methods achieved 93.33% accuracy. The AUC of CCH-NET was 0.848, outperforming senior ultrasound physicians (0.681) ,demonstrating superior diagnostic performance. Conclusion:The radiomics-based CCH-NET model, using non-nodular hypoechoic areas as a specific indicator, can accurately identify early SN-HT in euthyroid patients. It significantly outperforms senior ultrasound physicians, improving diagnostic accuracy and reducing missed diagnoses.
7.Ultrasound radiomics combined with machine learning for early diagnosis of seronegative hashimoto’s thyroiditis
Wenjun WU ; Chang LIU ; Shengsheng YAO ; Daming LIU ; Yuan LUO ; Yihan SUN ; Ting RUAN ; Mengyou LIU ; Li SHI ; Mingming XIAO ; Qi ZHANG ; Zhengshuai LIU ; Xingai JU ; Jiahao WANG ; Xiang FEI ; Li LU ; Yang GAO ; Ying ZHANG ; Liying GONG ; Xuanyu CHEN ; Wanli ZHENG ; Xiali NIU ; Xiao YANG ; Huimei CAO ; Shijie CHANG ; Zuoxin MA ; Jianchun CUI
Chinese Journal of Endocrine Surgery 2025;19(3):313-319
Objective:To evaluate the value of ultrasound radiomics combined with machine learning for early diagnosis of seronegative Hashimoto’s thyroiditis (SN-HT) .Methods:This retrospective study included 164 patients from Liaoning Provincial People’s Hospital , Lixin County People’s Hospital, Linghai Dalinghe Hospital, Fengcheng Phoenix Hospital, who underwent thyroidectomy for solitary nodules with normal thyroid function between Nov. 2016 and Jan. 2024. Postoperative pathology confirmed Hashimoto’s thyroiditis (HT) in some cases, who were further categorized into antibody-positive and antibody-negative groups based on serum antibody status. Patients without Hashimoto’s thyroiditis served as the control group. A total of 298 ultrasound images were analyzed. Radiomics features were extracted from hypoechoic non-nodular areas within 0.5 cm surrounding the tumor. Two senior pathologists and two senior ultrasound physicians independently assessed lymphocytic infiltration, eosinophilic changes of follicular epithelium, and the proportion of hypoechoic areas in pathology and ultrasound images, respectively. A machine learning model, CCH-NET, was developed using linear regression and t-distributed stochastic neighbor embedding (t-SNE) techniques. The dataset was divided into a training set (80%) and a validation set (20%) to compare the diagnostic accuracy of CCH-NET with that of senior ultrasound physicians. Results:In internal validation, CCH-NET achieved a diagnostic accuracy of 88.89% for both antibody-positive and antibody-negative groups, significantly higher than the 66.67% accuracy of senior ultrasound physicians ( P<0.01). In external validation, CCH-NET achieved 75.00% and 66.67% accuracy for the two groups, compared to 50.00% by senior ultrasound physicians. For the control group, both methods achieved 93.33% accuracy. The AUC of CCH-NET was 0.848, outperforming senior ultrasound physicians (0.681) ,demonstrating superior diagnostic performance. Conclusion:The radiomics-based CCH-NET model, using non-nodular hypoechoic areas as a specific indicator, can accurately identify early SN-HT in euthyroid patients. It significantly outperforms senior ultrasound physicians, improving diagnostic accuracy and reducing missed diagnoses.
8.Finite element analysis of a novel lumbar facet joint fusion device
Feilong SUN ; Haiyang QIU ; Yufei JI ; Yipeng YANG ; Daming LIU ; Longchao WANG ; Fei WANG ; Wei LEI ; Yang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(15):3081-3088
BACKGROUND:Facet joint osteoarthritis is acknowledged as a significant contributor to lower back pain in the geriatric population.The advent of an innovative spinal facet joint fusion device presents a therapeutic option for intervening during the initial stages of facet joint osteoarthritis,and significantly reduces the incidence of a series of complications caused by poor early conservative treatment and late surgical treatment.However,its effect on the biomechanics of the lumbar spine is unknown.OBJECTIVE:To investigate the biomechanical disparities between the novel lumbar zygapophyseal joint fusion device and traditional fusion devices.METHODS:A comprehensive three-dimensional finite element model of the L3-S1 lumbar spine was established and validated.Based on this intact model,three groups of surgical models were constructed:a bilateral pedicle screw fixation model,a bilateral novel facet joint fusion fixation model,and a bilateral facet screw fixation model,with the surgical segment designated as L4-5.Under a load of 500 N,a torque of 7.5 Nm was applied to all lumbar models to calculate the range of motion,displacement values,and intervertebral disc stress values at the L4-5 segment;stress values at the L3-4 and L5-S1 segments were also measured.RESULTS AND CONCLUSION:(1)Compared with the intact model,the range of motion at the L4-5 segment was reduced in all surgical models.(2)The novel device exhibited the smallest range of motion at the L4-5 segment under left and right rotational conditions;the greatest range of motion at the L4-5 segment under extension conditions;and a greater range of motion under other conditions than the bilateral pedicle screw fixation model.(3)The novel device demonstrated the smallest displacement values at the L4-5 segment under left and right rotational conditions;under other conditions,the displacement values at the L4-5 segment were greater than those in the bilateral pedicle screw fixation model.(4)In terms of stress distribution at the L4-5 segment,the novel device consistently exhibited the smallest values across all conditions.(5)For the L3-4 segment,the novel device showed the greatest stress values under extension and left and right rotational conditions,while under other conditions,the values were lower than those in the bilateral pedicle screw fixation model.(6)Compared with pedicle screw fixation,the novel device produced smaller stress values at the L5-S1 segment.(7)This study indicates that,compared with pedicle screw fixation,the novel device impacts the biomechanics of the lumbar spine by fusing the facet joints.It provides stability while preserving the range of motion at the surgical segment and reduces stress on the intervertebral discs of the surgical and adjacent segments,thereby potentially delaying disc degeneration.This suggests that the novel device can achieve biomechanical effects similar to those of pedicle screw fixation in theory.
9.Preliminary study on the effect of the third generation flow diverter device in the treatment of intracranial aneurysms
Xiaoliang YIN ; Jun YANG ; Tao WANG ; Xiaodong CHEN ; Peng LIU ; Daming WANG
Chinese Journal of Surgery 2025;63(3):233-239
Objective:To investigate the clinical effect of the third diverter device in the treatment of intracranial aneurysms.Methods:This is a retrospective case series study. A retrospective study was conducted on patients with intracranial aneurysms treated with the new flow-diverting device at the Department of Neurosurgery, Peking University Third Hospital from March 2023 to February 2024. There were 11 males and 27 females, aged (58.6±12.9) years (range: 27 to 82 years). All patients underwent digital subtraction angiography(DSA) at the time of surgery to observe the stent position, wall apposition. The degree of aneurysm embolization was evaluated using the O′Kelly-Marotta (OKM) grading system,with OKM grade D as complete occlusion. The incidence of perioperative intracranial hemorrhagic and ischemic complications was recorded. The modified Rankin scale (mRS) was used to assess patients′ neurological function at discharge. CT angiography and DSA were performed 6 to 12 months postoperatively to evaluate the stent position and aneurysm embolization.Results:A total of 38 patients with 39 intracranial aneurysms were treated using 40 stents, with coil embolization applied to 6 aneurysms. No ischemic or hemorrhagic events occurred during the perioperative period. At discharge, all patients had an mRS score of 0. During follow-up, one patient with an ophthalmic artery segment aneurysm experienced transient monocular blindness. Imaging follow-up by DSA showed that the complete aneurysm occlusion rate was 89.7%(35/39) at 6 months and 96.8%(30/31) at 12 months.Conclusion:The flow-diverting device demonstrates a low complication rate and a high aneurysm occlusion rate, which is a clinically optional treatment approach.
10.Mechanical thrombectomy:recent advancement of the clinical trials
Ximeng YANG ; Jun LU ; Junjie WANG ; Daming WANG
Chinese Journal of Surgery 2025;63(3):203-207
Mechanical thrombectomy has become the first choice for the treatment of acute ischemic stroke caused by large vessel occlusion since 2015. Over the past decade, on the basis of early clinical practice and research,mechanical thrombectomy has advanced rapidly, not only in expanding the therapeutic time window for mechanical thrombectomy but also in the necessity of bridging therapy, the benefits for patients with large infarct cores, basilar artery thrombectomy, thrombectomy for medium vessel occlusion, and the choice of thrombectomy methods. In the future, mechanical thrombectomy will bring benefits to more patients with ischemic stroke,through persistently explore, expanding the indications of mechanical thrombectomy, continuously optimizing patient selection, and improving the recanalization rate.

Result Analysis
Print
Save
E-mail