1.A qualitative study on the implementation status of family doctor contract services from the perspective of contracted residents
Jianhua CHEN ; Zihan PAN ; Xue JIN ; Wenping LI ; Yujing SU ; Hongjing PEI ; Jiapei XU ; Shan SUN ; Chunhua CHI
Chinese Journal of General Practitioners 2025;24(11):1360-1367
Objective:To explore the current implementation status and challenges of family doctor contract services (FDCS) from the perspective of contracted residents.Methods:This qualitative study used purposive sampling to select contracted residents from 11 primary healthcare institutions across five cities in China. Semi-structured interviews were conducted from March to December 2024, covering topics such as awareness of contracting, service experience, health needs, service continuity, and policy recommendations. Thematic framework analysis was applied to organize, code, and summarize the data.Results:A total of 25 contracted residents were interviewed (6 men, 19 women; 11 from central urban areas, 14 from suburban or rural towns; 8 with chronic diseases). Three main themes and ten sub-themes emerged: Theme Ⅰ: Pathways to improved service accessibility (optimized chronic disease management, more efficient referrals, and improved health education). Theme Ⅱ: Structural misalignment between supply and demand (limited specialty services despite patient needs, insufficient coverage and public awareness of home-based medical care, imbalanced human resources, and service disruption due to clinician turnover). Theme Ⅲ: Challenges in service awareness and communication mechanisms (information asymmetry and public misperception regarding FDCS, perverse incentives in administrative performance evaluation, and communication barriers in building patient-doctor trust).Conclusions:While FDCS has shown progress in chronic disease management, referral coordination, and health education, structural supply-demand gaps and communication challenges continue to hinder service quality. Improvements in resource allocation and service models are needed to support high-quality development.
2.Study on the influential factors of blood concentration for duloxetine based on therapeutic drug monitoring
Yang LUN ; Liguang DUAN ; Feiyue AN ; Ran FU ; Jing YU ; Chaoli CHEN ; Mengqiang ZHAO ; Shi SU ; Yang SONG ; Jiaqi WANG ; Yuhang YAN ; Chunhua ZHOU
China Pharmacy 2025;36(6):727-731
OBJECTIVE To explore the main factors influencing the blood concentration of duloxetine, and provide a scientific basis for the individualized use of duloxetine. METHODS Retrospective analysis was conducted on 434 inpatients with depressive disorders at the First Hospital of Hebei Medical University, who were treated with duloxetine and underwent blood concentration monitoring between January 2022 and April 2024. The study examined the impact of various factors, including gender, age, body mass index (BMI), gene phenotypes, combined medication, drug type (original/generic), and genotyping results of gene single nucleotide polymorphism loci, on blood concentration and the concentration-to-dose (C/D) after dose adjustment. RESULTS The blood concentration of duloxetine was 76.65 (45.57, 130.31) ng/mL, and C/D was 0.96 (0.63, 1.60) ng·d/(mL·mg). The blood concentration of duloxetine was positively correlated with the daily dose of administration (R2=0.253 7, P<0.001). Blood concentration of duloxetine in 38.94% of patients exceeded the recommended range specified in the guidelines. Gender, age, BMI, combined use of CYP2D6 enzyme inhibitors, and CYP2D6 and CYP1A2 phenotypes had significant effects on C/D of duloxetine (P<0.05). CONCLUSIONS The patient’s age, gender, BMI, combined medication, and genetic phenotypes are closely related to the blood concentration of duloxetine.
3.Application of wearable devices in monitoring acute exacerbations of chronic obstructive pulmonary disease in primary care
Mi YAO ; Yonghao LU ; Guanning JING ; Qiaoli SU ; Jiapei XU ; Yujing SU ; Jiao XU ; Yue CHEN ; Jingyi YE ; Jingyu HAO ; Yadong HUANG ; Chunhua CHI
Chinese Journal of General Practitioners 2025;24(12):1503-1509
Objective:To explore the correlation between abnormal vital signs (e.g., heart rate, oxygen saturation, and body temperature) and acute exacerbations in patients with chronic obstructive pulmonary disease (COPD), as well as to evaluate the clinical value of continuous monitoring via wearable devices for the early warning and intervention.Methods:A multicenter cross-sectional study enrolled 335 patients with stable chronic obstructive pulmonary disease (COPD) from 12 community health centers in Beijing and Chengdu between June 2023 and May 2024. General demographic and clinical data were collected, and each participant underwent continuous monitoring of resting heart rate, oxygen saturation, and body temperature using wearable devices for 21 days. Based on whether participants had experienced acute exacerbations requiring outpatient, emergency, or inpatient treatment within the previous year, they were categorized into the acute exacerbation group and the non-exacerbation group. Differences in physiological parameters between the acute exacerbation group and non-exacerbation group were analyzed, and contributing factors were assessed using logistic regression analysis.Results:A total of 335 patients with stable COPD were enrolled, including 252 cases (75.22%) in the acute exacerbation group and 83 cases (24.78%) in the non-acute exacerbation group. There were no statistically significant differences in age, sex distribution, comorbidities, or baseline lung function between the two groups (all P>0.05). Compared with the non-acute exacerbation group, patients in the acute exacerbation group had a faster resting heart rate((76.01 ± 7.78) beats/min vs. (72.72 ± 7.35) beats/min, t=3.126, P=0.002), a higher proportion of patients with decreased oxygen saturation (1.75% (0.97%, 3.03%) vs. 0.86% (0.44%, 1.65%), Z=11.086, P=0.001), and a higher proportion of patients with elevated body temperature (0.60% (0.39%, 1.03%) vs. 0.31% (0.17%, 0.54%), Z=7.314, P=0.007). Logistic regression analysis showed that advanced age ( OR=1.051, 95% CI: 1.023-1.080), increased heart rate ( OR=1.055, 95% CI:1.013-1.098), decreased oxygen saturation ( OR=1.197, 95% CI:1.023-1.400), and elevated body temperature ( OR=1.777, 95% CI:1.148-2.752) were positively associated factors for acute exacerbation of COPD. Conclusions:Abnormalities in physiological indicators such as heart rate, oxygen saturation, and body temperature are associated with acute exacerbations in COPD patients. Continuous monitoring using wearable devices may provide a new method for early warning and timely intervention in COPD exacerbations.
4.Analysis of earplugs protective and intervention effect of 220 noise exposed workers
Yanan WANG ; Weitao LIN ; Chunhua LIAO ; Lei LU ; Shibiao SU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(8):590-594
Objective:To investigate the use of earplugs among noise-exposed workers (Homo sapiens) in Bao'an District, Shenzhen, measure the personal attenuation rating (PAR) of earplugs when wearing earplugs, (Homo sapiens), analyze factors influencing the protective effect of earplugs, and evaluate the role of targeted wearing interventions in improving protective efficacy.Methods:From December 2022 to January 2023, 220 workers in noise-exposed positions from 3 enterprises in Bao'an District, Shenzhen were selected as subjects using the convenience sampling method. The Personal Attenuation Rating (PAR) values of workers wearing earplugs were measured using a fit testing system. Combined with the results of a questionnaire survey, the individual differences in workers' baseline PAR were described. A multivariate logistic regression model was used to analyze the influencing factors for earplugs to achieve the protective effect. One-on-one wearing interventions were implemented for workers who failed to achieve the protective effect, and repeated PAR tests were conducted. The changes in PAR of 120 workers before and after the intervention were compared.Results:The median baseline PAR for 220 workers was 7 (0, 14) dB, and the intervention rate was 54.55% (120/220). There were differences in the baseline PAR of workers with different length of service, earplugs wearing time and experience, daily noise exposure time and intensity, training and the comfort of earplug use ( P<0.05). The results of multivariate regression analysis showed that workers The comfort with earplugs wearing ( OR=2.81, 95% CI: 1.49~5.33, P<0.01) and training ( OR=6.60, 95% CI: 1.70~25.63, P<0.05) were the influencing factors of achieving the protective requirement. The median PAR was increased to 13 (11, 16) dB after intervention. Conclusion:The baseline protective effect of earplugs worn by workers is significantly influenced by comfort and enterprise training. One-on-one interventions can effectively improve the protective efficacy of those who fail to meet the requirements.
5.Analysis of earplugs protective and intervention effect of 220 noise exposed workers
Yanan WANG ; Weitao LIN ; Chunhua LIAO ; Lei LU ; Shibiao SU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(8):590-594
Objective:To investigate the use of earplugs among noise-exposed workers (Homo sapiens) in Bao'an District, Shenzhen, measure the personal attenuation rating (PAR) of earplugs when wearing earplugs, (Homo sapiens), analyze factors influencing the protective effect of earplugs, and evaluate the role of targeted wearing interventions in improving protective efficacy.Methods:From December 2022 to January 2023, 220 workers in noise-exposed positions from 3 enterprises in Bao'an District, Shenzhen were selected as subjects using the convenience sampling method. The Personal Attenuation Rating (PAR) values of workers wearing earplugs were measured using a fit testing system. Combined with the results of a questionnaire survey, the individual differences in workers' baseline PAR were described. A multivariate logistic regression model was used to analyze the influencing factors for earplugs to achieve the protective effect. One-on-one wearing interventions were implemented for workers who failed to achieve the protective effect, and repeated PAR tests were conducted. The changes in PAR of 120 workers before and after the intervention were compared.Results:The median baseline PAR for 220 workers was 7 (0, 14) dB, and the intervention rate was 54.55% (120/220). There were differences in the baseline PAR of workers with different length of service, earplugs wearing time and experience, daily noise exposure time and intensity, training and the comfort of earplug use ( P<0.05). The results of multivariate regression analysis showed that workers The comfort with earplugs wearing ( OR=2.81, 95% CI: 1.49~5.33, P<0.01) and training ( OR=6.60, 95% CI: 1.70~25.63, P<0.05) were the influencing factors of achieving the protective requirement. The median PAR was increased to 13 (11, 16) dB after intervention. Conclusion:The baseline protective effect of earplugs worn by workers is significantly influenced by comfort and enterprise training. One-on-one interventions can effectively improve the protective efficacy of those who fail to meet the requirements.
6.A qualitative study on the implementation status of family doctor contract services from the perspective of contracted residents
Jianhua CHEN ; Zihan PAN ; Xue JIN ; Wenping LI ; Yujing SU ; Hongjing PEI ; Jiapei XU ; Shan SUN ; Chunhua CHI
Chinese Journal of General Practitioners 2025;24(11):1360-1367
Objective:To explore the current implementation status and challenges of family doctor contract services (FDCS) from the perspective of contracted residents.Methods:This qualitative study used purposive sampling to select contracted residents from 11 primary healthcare institutions across five cities in China. Semi-structured interviews were conducted from March to December 2024, covering topics such as awareness of contracting, service experience, health needs, service continuity, and policy recommendations. Thematic framework analysis was applied to organize, code, and summarize the data.Results:A total of 25 contracted residents were interviewed (6 men, 19 women; 11 from central urban areas, 14 from suburban or rural towns; 8 with chronic diseases). Three main themes and ten sub-themes emerged: Theme Ⅰ: Pathways to improved service accessibility (optimized chronic disease management, more efficient referrals, and improved health education). Theme Ⅱ: Structural misalignment between supply and demand (limited specialty services despite patient needs, insufficient coverage and public awareness of home-based medical care, imbalanced human resources, and service disruption due to clinician turnover). Theme Ⅲ: Challenges in service awareness and communication mechanisms (information asymmetry and public misperception regarding FDCS, perverse incentives in administrative performance evaluation, and communication barriers in building patient-doctor trust).Conclusions:While FDCS has shown progress in chronic disease management, referral coordination, and health education, structural supply-demand gaps and communication challenges continue to hinder service quality. Improvements in resource allocation and service models are needed to support high-quality development.
7.Application of wearable devices in monitoring acute exacerbations of chronic obstructive pulmonary disease in primary care
Mi YAO ; Yonghao LU ; Guanning JING ; Qiaoli SU ; Jiapei XU ; Yujing SU ; Jiao XU ; Yue CHEN ; Jingyi YE ; Jingyu HAO ; Yadong HUANG ; Chunhua CHI
Chinese Journal of General Practitioners 2025;24(12):1503-1509
Objective:To explore the correlation between abnormal vital signs (e.g., heart rate, oxygen saturation, and body temperature) and acute exacerbations in patients with chronic obstructive pulmonary disease (COPD), as well as to evaluate the clinical value of continuous monitoring via wearable devices for the early warning and intervention.Methods:A multicenter cross-sectional study enrolled 335 patients with stable chronic obstructive pulmonary disease (COPD) from 12 community health centers in Beijing and Chengdu between June 2023 and May 2024. General demographic and clinical data were collected, and each participant underwent continuous monitoring of resting heart rate, oxygen saturation, and body temperature using wearable devices for 21 days. Based on whether participants had experienced acute exacerbations requiring outpatient, emergency, or inpatient treatment within the previous year, they were categorized into the acute exacerbation group and the non-exacerbation group. Differences in physiological parameters between the acute exacerbation group and non-exacerbation group were analyzed, and contributing factors were assessed using logistic regression analysis.Results:A total of 335 patients with stable COPD were enrolled, including 252 cases (75.22%) in the acute exacerbation group and 83 cases (24.78%) in the non-acute exacerbation group. There were no statistically significant differences in age, sex distribution, comorbidities, or baseline lung function between the two groups (all P>0.05). Compared with the non-acute exacerbation group, patients in the acute exacerbation group had a faster resting heart rate((76.01 ± 7.78) beats/min vs. (72.72 ± 7.35) beats/min, t=3.126, P=0.002), a higher proportion of patients with decreased oxygen saturation (1.75% (0.97%, 3.03%) vs. 0.86% (0.44%, 1.65%), Z=11.086, P=0.001), and a higher proportion of patients with elevated body temperature (0.60% (0.39%, 1.03%) vs. 0.31% (0.17%, 0.54%), Z=7.314, P=0.007). Logistic regression analysis showed that advanced age ( OR=1.051, 95% CI: 1.023-1.080), increased heart rate ( OR=1.055, 95% CI:1.013-1.098), decreased oxygen saturation ( OR=1.197, 95% CI:1.023-1.400), and elevated body temperature ( OR=1.777, 95% CI:1.148-2.752) were positively associated factors for acute exacerbation of COPD. Conclusions:Abnormalities in physiological indicators such as heart rate, oxygen saturation, and body temperature are associated with acute exacerbations in COPD patients. Continuous monitoring using wearable devices may provide a new method for early warning and timely intervention in COPD exacerbations.
8.Study on the fit testing for the workers wearing hearing protection device in machinery manufacturing enterprises
Yanan WANG ; Shibiao SU ; Chunhua LIAO ; Xi ZHONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(1):16-21
Objective:To investigate the occupational noise hazards in five machinery manufacturing enterprises, and to evaluate the individual noise reduction values and influencing factors of workers wearing hearing protection device (HPD) by individual fit testing.Methods:From November 2021 to January 2022, 5 machinery manufacturing enterprises in Bao'an District of Shenzhen were selected to conduct an occupational health survey to understand the noise exposure level of workers. The 3MTM E-A-RfitTM fitness test system was used to test the baseline individual sound attenuation value level (PAR) of the daily wear of the ear protecters for 485 workers in typical noise working positions. Workers whose PAR values could not meet the requirements of noise reduction at work were instructed to wear and repeated tests were conducted. PAR results of the workers before and after the intervention were collected and analyzed.Results:The noise workers who received the suitability test were mainly distributed in 24 types of work, the job noise exposure level was 80.2 dB (A) ~ 95.0 dB (A), and the job noise excess rate was 52.5% (138/263). The median baseline PAR [ M ( Q1, Q3) ] for 485 workers was 6.0 (0.0, 14.0) dB. The baseline PAR of male workers, those with more than 15 years of working experience, those with more than 15 years of using ear guards, those who considered ear guards comfortable to wear, those with college degree or above, and those exposed to noise level 90 dB (A) were higher, and the difference was statistically significant ( P<0.05). A total of 275 workers (56.7%) did not pass the baseline PAR test, and there was no statistically significant difference in the intervention rate of workers in different noise groups ( P>0.05). PAR in subjects who did not pass baseline after intervention increased from 0.0 (0.0, 3.0) dB to 15.0 (12.0, 18.2) dB. Conclusion:The workplace noise hazard of machinery manufacturing enterprises is serious, and there is a great difference between the baseline PAR and the nominal value of the hearing guard worn by the noise exposed workers. The intervention measures can effectively improve the protective effect of wearing ear protectors.
9.A case of recurrent convulsions caused by acute sulfuryl fluoride gas poisoning
Qingbo ZHANG ; Zhenhua LI ; Rui WANG ; Yugang ZHANG ; Chunhua SU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(8):613-615
Sulfuryl fluoride is a kind of pesticide with strong permeability, convenient use at low temperature, non-corrosive and other characteristics, which can kill food pests and has strong lethality to termites. In acute sulfuryl fluoride poisoning, patients can see recurrent convulsions, epileptic electroencephalogram abnormalities such as matrix spikes or high amplitude spikes. In this paper, a patient with sulfuryl fluoride poisoning with convulsion-based mental system symptoms was reported, and after clinical treatment with dexamethasone and phenobarbital sodium, the patient was cured and discharged.
10.Effects of Different Frequencies of Electroacupuncture on the Degree of Atrophy of the Quadriceps Femoris in Rabbits with Anterior Cruciate Ligament Injury
Yongyuan HUANG ; Hong SU ; Pengyi ZHANG ; Yeteng WEI ; Zhaolin XU ; Chunhua FU ; Huijiao CHEN ; Xuejie YANG ; Jiaying LI ; Chenxi WANG
Chinese Journal of Information on Traditional Chinese Medicine 2024;31(6):88-94
Objective To observe the effects of different frequencies of electroacupuncture on the degree of atrophy of quadriceps femoris in rabbits with anterior cruciate ligament(ACL)injury model;To explore the possible mechanisms of electroacupuncture in treating ACL injury.Methods Totally 24 New Zealand rabbits were randomly divided into blank group,model group,low-frequency electroacupuncture group and high-frequency electroacupuncture group,with 6 rabbits in each group.Except for the blank group,ACL injury models were established in the other groups.On the 7th day after modeling,the low-frequency electroacupuncture group and the high-frequency electroacupuncture group performed electroacupuncture treatment(continuous wave,frequency of 2 Hz and 100 Hz respectively,and left the needle in place for 20 min)at"Xuehai"and"Liangqiu"of the operation side,and the remaining groups were only grasped and immobilized,for 21 days.The mass ratio of the quadriceps femoris was calculated,the histopathological morphology of the quadriceps femoris tissue of the rabbits in each group was observed by HE staining,the expressions of NO,iNOS in quadriceps femoris tissue were detected by ELISA,the content of ROS in quadriceps femoris tissue was detected by fluorescent probe,the protein expressions of PERK,ATF6,IRE1,MuRF1,MAFbx in quadriceps femoris tissue were detected by Western blot.Results Compared with the blank group,the quadriceps femoris muscle mass ratio of the model group rabbits was significantly reduced(P<0.01),with irregular arrangement of muscle cells,accompanied by swelling and atrophy,significant interstitial edema,and extensive inflammatory infiltration,the contents of NO,iNOS and ROS in quadriceps femoris tissue significantly increased(P<0.01),while the expressions of PERK,ATF6,IRE1,MuRF1 and MAFbx proteins significantly increased(P<0.01).Compared with the model group,the quadriceps femoris muscle mass ratio in the low-frequency and high-frequency electroacupuncture groups significantly increased(P<0.01),with regular arrangement of muscle cells,improved swelling and atrophy of cells,and reduced interstitial edema and inflammation,the contents of NO,iNOS and ROS in quadriceps femoris tissue were significantly reduced(P<0.01),and the expressions of PERK,ATF6,IRE1,MuRF1 and MAFbx proteins significantly decreased(P<0.01).Moreover,the low-frequency electroacupuncture group had better effects than the high-frequency electroacupuncture group(P<0.05).Conclusion Different frequencies of electroacupuncture intervention in ACL injury rabbits can better delay the degree of quadriceps femoris atrophy,and its mechanism may be related to reducing the expressions of oxidative metabolites NO,iNOS,ROS,and reducing the expressions of endoplasmic reticulum stress-related proteins PERK,ATF6,IRE1 in quadriceps fermoris,which in turn inhibit the expressions of quadriceps atrophy factors MuRF1,MAFbx,and delaying the degradation of quadriceps muscle proteins.The effect of low-frequency electroacupuncture is superior to the high-frequency electroacupuncture.

Result Analysis
Print
Save
E-mail