1.Research advance of MRI for ESRD patients with cognitive impairment who receiving hemodialysis
Chujie CHEN ; Hui XIAO ; Liyuan FU
China Medical Equipment 2025;22(3):148-153
Cognitive impairment(CI)is a common complication in patients with end-stage renal disease(ESRD),who can appear decline of the cognition at multi fields include attention,memory,and executive function at early stage.However,the potentially neuropathological mechanisms of ESRD patients with CI still is unknown to be great extent.Therefore,it is great challenge to detect patients at early stage.In recent years,the development of multi-modal magnetic resonance imaging(MRI)has taken the research of this field to gain many progress.Based on the above reasons,this review systematically explored the research advance of multi modal MRI for ESRD patients with CI who received hemodialysis,and elaborated the important progress of MRI technique in neuropathological aspect of ERSD patients with CI from the changes of brain structure,brain function,brain perfusion,and brain metabolism,which aim was to explore the potential mechanism of ESRD patients with CI,so as to provide new direction for early diagnosis and treatment.
2.Study on changes of choroid plexus volume in patients with essential hypertension using deep learning-based image segmentation
Shiluo YANG ; Chujie CHEN ; Hao YU ; Xiaoyang WANG ; Liyuan FU
China Medical Equipment 2025;22(9):8-11
Objective:To investigate changes of choroid plexus volume in patients with essential hypertension using deep learning-based segmentation technique.Methods:According to the inclusion criteria,19 patients with essential hypertension who visited The 900th Hospital of People's Liberation Army Joint Service Support Force from December 2022 to May 2024 were divided into hypertension group.Additionally,19 healthy individuals,matched with the hypertension group in terms of gender,age,and years of education,were recruited as the healthy control group during the same period.All participants underwent data acquisition of three-dimensional T1(T1-3D)brain structural images using a Siemens 3.0T Trio magnetic resonance(MR)scanner.A pre-trained deep learning model,which based on the 3D U-Net architecture and generated by fully convolutional neural network,was employed for choroid plexus segmentation,and the total brain volume and lateral ventricle volume were calculated using the United Imaging Artificial Intelligence(AI)platform.Statistical analysis of the choroid plexus volume and other data for both groups were performed using SPSS27.0.Results:Compared with the healthy control group(1 866 mm3),the hypertensive group(2 047 mm3)showed an abnormal increase in choroid plexus volume(x2=3.900,P<0.05).Moreover,the choroid plexus volume was positively correlated with lateral ventricle volume and systolic blood pressure(r=0.849,P<0.05),and was negatively correlated with digit span(forward)in the hypertensive group(r=-0.374,P<0.05).Conclusion:The choroid plexus volume in patients with essential hypertension abnormally increased,which might be a factor promoting to changes in brain structure,it can affect further the cognitive function of patients with hypertension.
3.Research advance of MRI for ESRD patients with cognitive impairment who receiving hemodialysis
Chujie CHEN ; Hui XIAO ; Liyuan FU
China Medical Equipment 2025;22(3):148-153
Cognitive impairment(CI)is a common complication in patients with end-stage renal disease(ESRD),who can appear decline of the cognition at multi fields include attention,memory,and executive function at early stage.However,the potentially neuropathological mechanisms of ESRD patients with CI still is unknown to be great extent.Therefore,it is great challenge to detect patients at early stage.In recent years,the development of multi-modal magnetic resonance imaging(MRI)has taken the research of this field to gain many progress.Based on the above reasons,this review systematically explored the research advance of multi modal MRI for ESRD patients with CI who received hemodialysis,and elaborated the important progress of MRI technique in neuropathological aspect of ERSD patients with CI from the changes of brain structure,brain function,brain perfusion,and brain metabolism,which aim was to explore the potential mechanism of ESRD patients with CI,so as to provide new direction for early diagnosis and treatment.
4.Study on changes of choroid plexus volume in patients with essential hypertension using deep learning-based image segmentation
Shiluo YANG ; Chujie CHEN ; Hao YU ; Xiaoyang WANG ; Liyuan FU
China Medical Equipment 2025;22(9):8-11
Objective:To investigate changes of choroid plexus volume in patients with essential hypertension using deep learning-based segmentation technique.Methods:According to the inclusion criteria,19 patients with essential hypertension who visited The 900th Hospital of People's Liberation Army Joint Service Support Force from December 2022 to May 2024 were divided into hypertension group.Additionally,19 healthy individuals,matched with the hypertension group in terms of gender,age,and years of education,were recruited as the healthy control group during the same period.All participants underwent data acquisition of three-dimensional T1(T1-3D)brain structural images using a Siemens 3.0T Trio magnetic resonance(MR)scanner.A pre-trained deep learning model,which based on the 3D U-Net architecture and generated by fully convolutional neural network,was employed for choroid plexus segmentation,and the total brain volume and lateral ventricle volume were calculated using the United Imaging Artificial Intelligence(AI)platform.Statistical analysis of the choroid plexus volume and other data for both groups were performed using SPSS27.0.Results:Compared with the healthy control group(1 866 mm3),the hypertensive group(2 047 mm3)showed an abnormal increase in choroid plexus volume(x2=3.900,P<0.05).Moreover,the choroid plexus volume was positively correlated with lateral ventricle volume and systolic blood pressure(r=0.849,P<0.05),and was negatively correlated with digit span(forward)in the hypertensive group(r=-0.374,P<0.05).Conclusion:The choroid plexus volume in patients with essential hypertension abnormally increased,which might be a factor promoting to changes in brain structure,it can affect further the cognitive function of patients with hypertension.
5.Factor analysis of pelvic tilt outcome after primary unilateral total hip arthroplasty
Lin LU ; Haicheng CHEN ; Chujie CHEN ; Chi ZHOU ; Zhenqiu CHEN
Chinese Journal of Tissue Engineering Research 2024;28(36):5817-5822
BACKGROUND:Pelvic tilt,which is often seen in hip diseases,is also a common functional problem after total hip arthroplasty. OBJECTIVE:To investigate the mechanism of occurrence and recovery of pelvic tilt after unilateral total hip arthroplasty in patients with femoral head necrosis. METHODS:The clinical data of 100 patients with femoral head necrosis who underwent unilateral total hip arthroplasty in the Department of Femoral Head Necrosis,Bone Injury Center of First Affiliated Hospital of Guangzhou University of Chinese Medicine were collected retrospectively from June 2021 to February 2023.The patients were divided into three groups,namely,groups A(<2°,n=48),B(2°-3°,n=34),and C(>3°,n=18),according to the severity of pelvic tilt on postoperative 3 day.Statistical data were collected and compared between the pre-and postoperative periods of patients of these three groups in terms of the angle of the coronal plane of the pelvis tilt,the length of the gluteus medius muscles of the bilateral sides,the heights of the rotational centers of the femoral heads,the difference in the lengths of the gluteus medius muscles of the bilateral sides and the heights of the rotational centers of the femoral heads,and the ratio of changes in the angle of the pelvic tilt.Pearson correlation coefficient was used to examine the correlation between pelvic tilt angle and other indexes. RESULTS AND CONCLUSION:(1)Pelvic tilt aggravation occurred in the short term after surgery.(2)The ratio of change in pelvic tilt angle from postoperative 3 days to postoperative 1 month time period differed between the groups,with group C>group B>group A.There was a difference between group C and the other groups in the time period from postoperative 1 to postoperative 3 months,with the ratio of change being the smallest in group C.There was no difference in the ratio of change between the groups in the time period from postoperative 3 days to postoperative 3 months.(3)The difference in bilateral gluteus medius muscles decreased gradually after surgery,and there was no difference in the comparison of bilateral gluteus medius muscles in the time period from postoperative 3 months.(4)The difference between bilateral centers of rotation increased after surgery,and the difference between bilateral heights at 3 months after surgery was smaller than that before surgery.(5)The pelvic tilt angle at 3 days after surgery,the duration of the disease and the pelvic tilt angle at 3 months after surgery were significantly correlated(all P=0.000),and the difference between bilateral gluteus medius muscles before surgery and the pelvic tilt angle at 3 days after surgery was significantly correlated(P=0.006)(6)The functional pelvic tilt occurred in the patients with femoral head necrosis after total hip arthroplasty.Correction of the pelvic tilt after surgery was based on the adaptive restoration of the functional pelvic tilt angle after surgery.Functional pelvic tilt arises as a compensatory adaptation of the organism based on the short-term postoperative reconstruction of bony structures and the survival of cumulative soft tissue damage.
6.Strategy to Guide Revascularization of Non-culprit Lesions in Patients With STEMI:State of Art and Future Prospects
Yingyang GENG ; Yin ZHANG ; Chujie ZHANG ; Han ZHANG ; Jingjing XU ; Ying SONG ; Cheng CUI ; Pei ZHU ; Lijian GAO ; Zhan GAO ; Jue CHEN ; Lei SONG
Chinese Circulation Journal 2024;39(3):301-305
Acute ST-segment elevation myocardial infarction with multivessel disease is one of the high-risk types of coronary heart disease.Early opening of infarct-related artery and reperfusion of myocardium could significantly reduce the mortality in acute phase.However,the presence of non-culprit lesions in non-infarct-related arteries is still at risk and has an important impact on the long-term prognosis of patients.It remains controversial on how to precisely evaluate the clinical significance and revascularization value of non-culprit lesions.This article aims to review the research status and progress of guidance strategies of non-culprit lesion revascularization in patients with ST-segment elevation myocardial infarction and multivessel disease.
7.Research on MRE quality control in diagnosing intestinal diseases
Chujie CHEN ; Zhen CHEN ; Chaoshang LIN ; Chengkun HONG ; Peiyun YE ; Jiamin CHEN ; Yonggang LIANG ; Liyuan FU
China Medical Equipment 2024;21(2):7-11
Objective:To investigate the quality control of magnetic resonance enterography(MRE)in the diagnosis of intestine diseases,and analyze the factors that affected the imaging quality of MRE,and enhance the imaging quality of MRE through adopted the measures of quality control.Methods:The documents of MRE examinations of 167 patients with intestinal disease who admitted to the 900th Hospital of People's Liberation Army Joint Service Support Force from May 2018 to March 2023 were retrospectively analyzed.The image qualities of all patients were evaluated after they completed clinical and image examinations.The reasons that image quality could not meet the requirement of diagnosis were analyzed.And then,the measures of quality control were proposed.Results:In 167 patients with intestinal disease,the MRE images of 153 patients(91.62%)could meet the requirement of diagnosis.In 14 patients(8.38%)whose MRE images could not meet the requirement of diagnosis,the reason of 3 cases(1.80%)was poor respiratory coordination,and that of 2 cases(1.20%)was there were more severe magnetic sensitive artifacts in images,and that of 1 case(0.60%)was severe intestinal peristalsis leaded to blurred images,and that of 2 cases(1.20%)was the flow void effect from intestinal peristalsis inside of intestinal cavity could not meet the requirement of diagnosis,and that of 4 cases(2.40%)was the intestinal tube without incomplete dilation caused by poor oral filling contrast agent,and that of 2 cases(1.20%)was many residues in intestine due to poor preparation for intestine.Aimed at the factors that MRE images could not meet requirement of diagnosis,we proposed the following quality control measures:①the biphasic contrast agents with favorable safety,without severe adverse reactions,which can fully dilate intestinal cavity,should be selected.②we should do well for the dilation of intestinal tube,and inhibit the intestinal peristalsis and conduct respiratory training.③we should conduct scan with wide field at coronal site,so as to display panorama image of intestine.④The scans of conventionally anatomical sequence and functional imaging sequence on axis position were performed on lesions.Conclusion:MRE technique should choose appropriate contrast agent in the quality control of the diagnosis of intestine diseases,and do well the preparation for patients before examination.Using intraluminal contrast agents,conducting intestinal dilation and optimal imaging technique are essential for obtaining intestinal MRE images with high quality.
8.Bibliometric analysis of radiomics research
Miyang YANG ; Chujie CHEN ; Zhaochu WANG ; Peiyun YE ; Chengkun HONG ; Yuhang ZHANG ; Liyuan FU
China Medical Equipment 2024;21(8):113-120
Objective:To analyze the development status,frontiers and hotspots of radiomics research in the past five years from 2019 to 2023,and to provide theoretical reference and guidance for radiomics research in China.Methods:The relevant literature in the field of radiomics published in the core database of Web of Science(WOS)from January 1,2003 to August 10,2023 were searched.According to the inclusion and exclusion criteria,6,777 eligible literatures were screened and obtained,including 6,254 articles in the past five years from January 1,2019 to August 10,2023.Bibliometric methods were used to analyze the clustering of countries and regions,institutions,journals,authors,keywords and draw visual maps.Results:The 6,777 radiomics-related articles published between 2003 and 2023 were first published in 2011,and the number of papers tended to stabilize in 2018,and then the number showed a significant trend of increasing year by year.Among the 6,254 articles published from 2019 to 2023,China(3,564 articles),United States(1,164 articles),and Italy(530 articles)ranked the top 3 in terms of publication volume,with close cooperation between countries.General Electric of the United States published the most papers(448 articles),and the journal Frontiers in Oncology(704 papers)ranked first in terms of paper publication volume.From 2019 to 2023,the diseases of concern in the field of radiomics are rectal cancer,hepatocellular carcinoma,breast cancer,and lung cancer(especially non-small cell lung cancer).Conclusion:Although China ranks first in the number of national publications,the quality of research still needs to be improved.In the future,the research trend in the field of radiomics may be the diagnosis and differential diagnosis of various diseases,the prediction and evaluation of curative effect,the evaluation of tumor disease metastasis and the identification of gene phenotype based on radiomics combined with multiple imaging techniques.
9.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.
10.Automatic measurement of detection parameters of quality control of MSCT imaging system
Peiyun YE ; Hui XIONG ; Jian CHEN ; Zhifeng HUANG ; Yamei LIN ; Zhijie YANG ; Chujie CHEN ; Miyang YANG ; Chengkun HONG ; Yuhang ZHANG ; Minghui MAO ; Taipeng ZENG ; Liyuan FU
China Medical Equipment 2024;21(12):18-24
Objective:To design an intelligent measurement program of detection parameters of quality control of imaging system of multi-slice spiral computed tomography (MSCT) based on MATLAB software platform,so as to achieve intelligent detection for quality control of MSCT imaging system. Methods:We designed an intelligent measurement program for the detection parameters of quality control of MSCT imaging system (referred to as the intelligent measurement program) bases on the function of graphical user interfaces (GUI) of MATLAB software. A series of algorithms such as image reading,binarization,and circular detection based on the Hough transform were employed to conduct automatic measurement and calculation for CT values (water),noise and uniformity of the parameters of MSCT quality control. The Intraclass Correlation Coefficient (ICC) was adopted to analyze the consistency of the detection results between the manual measurement method and the designed intelligent detection program. Results:The designed intelligent measurement program in this study can automatically assess the detection parameters of quality control of the MSCT imaging system,which included CT values (water),noise and uniformity. There was favorable consistency in the detection results between the manual measurement method and the intelligent measurement program (range of ICC values was from 0.881 to 0.985). Conclusion:The intelligent measurement program of detection parameters of quality control of MSCT imaging system can simplify the process of calculating detection parameters of quality control of MSCT imaging system,and provide a reliable detection tool for quality control of MSCT imaging equipment,which can effectively improve the detection efficiency of quality control.

Result Analysis
Print
Save
E-mail