1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Research advance on the perioperative management of flexible ureteral lithotripsy under local anesthesia
Chaolin YU ; Pingbo XIE ; Jiaxi PENG ; Hongqing ZHOU ; Yonghua LUO ; Zihan DAI ; Chuan LIU
Journal of Modern Urology 2025;30(3):266-271
Flexible ureteral lithotripsy (FURL) under general anesthesia (GA) is the dominant method in the treatment of renal and upper ureteral calculi,but some patients cannot tolerate GA.In recent years,there has been a growing interest in the use of local anesthesia (LA) as a safe and effective alternative.And it is also an option for patients who have calculi ≤20 mm with high fragility,lower CT value and better compatibility.Before surgery,it is important to conduct relevant examinations,evaluate the status of patients,prevent infections,and indwell ureteral stents.During surgery,lithotomy position,scissors position,prone leg position and other positions should be selected according to the specific conditions of patients.LA drugs should be used to control physiological pain and relieve psychological anxiety.Patients' breathing state should be carefully monitored,and appropriate ureteroscope and lens sheath should be selected for the success and safety of the operation.In this paper,the perioperative management of FURL under LA is briefly summarized,so as to provide reference for clinical practice.
7.Changes in coordination of departments for major epidemic prevention and control in China before and after the outbreak of COVID-19: an analysis on official documents
Zhonghui HE ; Peiwu SHI ; Qunhong SHEN ; Zheng CHEN ; Chuan PU ; Lingzhong XU ; Zhi HU ; Anning MA ; Tianqiang XU ; Panshi WANG ; Hua WANG ; Qingyu ZHOU ; Chengyue LI ; Mo HAO
Shanghai Journal of Preventive Medicine 2025;37(5):446-450
ObjectiveTo analyze the changes in the degree of coordination of China's major epidemic prevention and control efforts before and after the outbreak of the Corona Virus Disease 2019 (COVID-19), so as to explore the impact of epidemic prevention and control measures on coordination dynamics. MethodsA total of 3 864 policy documents related to epidemic prevention and control from January 2000 to December 2020 across 31 provinces (autonomous regions, and municipalities) in China were systematically collected. Contents specific to collaborative and cooperative efforts were extracted, and the extent of interdepartmental coordination were quantified to assess the effectiveness of epidemic prevention and control efforts. Wilcoxon signed-rank test was adopted to statistically analyze the differences between the indicators before and after the epidemic. ResultsThe average overall coordination level for major epidemic prevention and control in 31 provinces (autonomous regions, and municipalities) increased from 43.06% to 97.62%, and the average coordination levels in the eastern, central, and western China soared from 42.29%, 37.50%, and 47.46%, to 98.81%, 96.20%, and 97.46%, respectively, with statistically significant differences (all P<0.05). In terms of department categorization, coordination levels in the professional departments and the key support departments peaked at 100.00%, while other support departments rose to 95.43%, with an increase of 77.15%, 181.85%, and 139.89%, respectively, exhibiting noteworthy statistically significant differences (all P<0.001). ConclusionThe scope of coordination departments of China’s major epidemic prevention and control exists a remarkable surge following the COVID-19 outbreak, notable heightened coordination is particularly observed among the key support departments. Future endeavors should prioritize the roles played by diverse departments in epidemic prevention and control, enhancing both the clarity of departmental responsibilities and the effectiveness of interdepartmental coordination.
8.A systematic evaluation of the public health governance capacity of 40 cities in Jiangsu, Zhejiang, and Anhui Provinces
Huayi ZHANG ; Qingyu ZHOU ; Huihui HUANGFU ; Peiwu SHI ; Qunhong SHEN ; Chaoyang ZHANG ; Zheng CHEN ; Chuan PU ; Lingzhong XU ; Anning MA ; Zhaohui GONG ; Tianqiang XU ; Panshi WANG ; Hua WANG ; Chao HAO ; Zhi HU ; Chengyue LI ; Mo HAO
Shanghai Journal of Preventive Medicine 2025;37(5):451-457
ObjectiveTo systematically evaluate the public health governance capacity of 40 cities in Jiangsu, Zhejiang, and Anhui Provinces, providing a scientific evaluation basis for building a "Healthy Yangtze River Delta". MethodsA comprehensive collection of policy documents, public information reports, and research literature related to public health governance capacity in Jiangsu, Zhejiang, and Anhui Provinces was conducted, totaling 6 920 policy documents, 1 720 information reports, and 1 200 literature pieces. Based on the evaluation standards for an appropriate public health system established by the research team, the basic status of public health governance capacity was assessed to identify the strengths and weaknesses of the 40 cities. ResultsIn 2022, the public health governance capacity score for the 40 cities in Jiangsu, Zhejiang, and Anhui Provinces was (562.5±38.0) points. In terms of specific areas, the emergency response field received the highest score of (791.4±49.7) points, while the chronic disease prevention and control field received the lowest score of (368.2±29.6) points. The Jiangsu-Zhejiang-Anhui region has largely achieved the strategic priority of health, gradually improved public health legal regulations, and established a basic organizational framework with a solid foundation for information and data infrastructure. However, challenges still need to be addressed, such as unstable government funding for public health, unclear departmental responsibilities, and barriers to information interoperability. ConclusionThe public health governance capacity of the 40 cities in Jiangsu, Zhejiang, and Anhui Province has been at a moderate level, but disparities have still existed across regions and fields. In the future, while continuing to deepen existing advantages, it is essential to accurately identify the causes of problems, establish a long-term and stable investment mechanism, enhance information connectivity mechanisms, further clarify departmental responsibilities, and promote the achievement of the "Healthy Yangtze River Delta" goal.
9.Bioequivalence study of ritonavir tablets in Chinese healthy subjects
Yuan-Yuan XU ; Chuan-Shu WANG ; Shao-Chun CHEN ; Jia-Xiang DING ; Xue-Feng WANG ; He-Yue WANG ; Jing XIE ; Huan ZHOU
The Chinese Journal of Clinical Pharmacology 2024;40(10):1502-1506
Objective To evaluate the bioequivalence of a single oral dose of ritonavir in fasted and fed conditions in healthy Chinese adult subjects with the test and reference formulations.Methods A single-center,open-label,randomized,single-dose,two-periods,two-sequence crossover design was used,and 64 subjects were enrolled in both the fasted and fed groups.The subjects received 100 mg of the test preparation or reference preparation orally per cycle,and the drug concentration of ritonavir in plasma was detected using the high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method.Pharmacokinetic parameters were estimated by a non-compartment model,and SAS 9.4 software was used for statistical analysis.Results Arithmetic mean values of the main pharmacokinetic parameters of the subject formulation of ritonavir tablets and the reference formulation in the fasting group:Cmax were(791.90±400.20)and(809.60±449.14)ng·mL-1;AUC0_t were(6 072.61±2 631.98)and(6 296.30±3 388.95)ng·h·mL-1;AUC0-∞ were(6 129.59±2 655.57)and(6 347.26±3 434.12)ng·h·mL-1,respectively.Arithmetic mean values of the main pharmacokinetic parameters of the subject formulation of ritonavir tablets and the reference formulation in the fed group:Cmax were(512.37±233.60)and(521.74±223.87)ng·mL-1;AUC0_t were(4 203.43±2 221.33)and(4 200.13±1 993.50)ng·h·mL-1;AUC0_∞ were(4 259.21±2 266.88)and(4 259.63±2 044.12)ng·h·mL-1.The 90%confidence intervals for the geometric mean ratios of Cmax,AUC0_t and AUC0_∞ of the prototype drug ritonavir in plasma after oral administration of 100 mg of the test and reference formulations of ritonavir tablets under fasting and fed conditions fell within the 80.00%to 125.00%equivalence interval.Conclusion The test and reference formulations of ritonavir tablets were bioequivalent under fasting and postprandial conditions.
10.RNA SNP Detection Method With Improved Specificity Based on Dual-competitive-padlock-probe
Qin-Qin ZHANG ; Jin-Ze LI ; Wei ZHANG ; Chuan-Yu LI ; Zhi-Qi ZHANG ; Jia YAO ; Hong DU ; Lian-Qun ZHOU ; Zhen GUO
Progress in Biochemistry and Biophysics 2024;51(11):3021-3033
ObjectiveThe detection of RNA single nucleotide polymorphism (SNP) is of great importance due to their association with protein expression related to various diseases and drug responses. At present, splintR ligase-assisted methods are important approaches for RNA direct detection, but its specificity will be limited when the fidelity of ligases is not ideal. The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection. MethodsIn this study, a dual-competitive-padlock-probe (DCPLP) assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation. To verify the method, we employed dual competitive padlock probe-mediated rolling circle amplification (DCPLP-RCA) to genotype the CYP2C9 gene. ResultsThe specificity was well improved through the competition and strand displacement of dual padlock probe, with an 83.26% reduction in nonspecific signal. By detecting synthetic RNA samples, the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L. Furthermore, clinical samples were applied to the method to evaluate its performance, and the genotyping results were consistent with those obtained using the qPCR method. ConclusionThis study has successfully established a highly specific direct RNA SNP detection method, and provided a novel avenue for accurate identification of various types of RNAs.

Result Analysis
Print
Save
E-mail