1.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Super-elderly treatment resistant depression patient treated with modified electroconvulsive therapy: a case report
Shan CHONG ; Na'na XIONG ; Tengteng FAN
Sichuan Mental Health 2025;38(1):84-88
The paper reported a case of super-elderly patient with treatment-resistant depression who underwent modified electroconvulsive therapy (MECT). The patient was an 87-year-old female presented to the hospital with an 8-year history of depressive disorder marked by intermittent episodes, who exhibited poor response to various antidepressants while achieved a significant improvement after receiving MECT. In the past two years, the patient experienced a recurrence of depression following life stress events. The condition showed improvement with the administration of MECT. However, after discontinuation of MECT, the depression relapsed multiple times, prompting rehospitalization for continued MECT to sustain clinical benefits. The patient demonstrated overall tolerable adherence to MECT. Based on research of domestic and international, this paper explored treatment options for super-elderly patients with treatment-resistant depression, aiming to provide insights into the application of MECT in the management of depression among super-elderly patients with depression. [Funded by National Key Research and Development Project (number, 2019YFC0118502)]
6.Feasibility of deep learning technique based on CT radiomics in improving the diagnostic accuracy for pulmonary nodules
Xianhu ZHANG ; Zhigang ZHANG ; Fang LIU ; Ying GUO ; Fan LI ; Chong LIU
China Medical Equipment 2025;22(9):12-16
Objective:To investigate the feasibility of deep learning based on computed tomography(CT)radiomics in improving diagnostic accuracy for pulmonary nodules.Methods:A total of 500 patients with pulmonary nodules who admitted to our hospital from January 2023 to January 2024 were selected as study subjects,and they were randomly divided into a training set(350 patients)and a test set(150 patients)as 7:3 ratio.All patients underwent CT examination,and pathological diagnosis was used as gold standard to record pulmonary nodules that were judged by clinical judgment.The radiomics features were screened from the CT images of the patients,and these features were used to construct multiple machine learning models.The predictive value of different models in diagnosing pulmonary nodules was analyzed through confusion matrices and receiver operating characteristic(ROC)curve.Results:A total of 1,594 radiomics features,including 1,195 texture features(74.97%)that was the largest ratio,334 first-order histograms(20.95%),and 65 second-order histograms(4.08%),were extracted in this study.After least absolute shrinkage and selection operator(LASSO)regression analysis and ten-fold cross-validation processing,a total of six radiomics features were screened out.The screened radiomics features were incorporated respectively into four assembled models with machine learning,including ResNet50,DenseNet121,Inception_V3 and VGG19.The constructed models were evaluated respectively using the training set and the test set.The results showed that the assembled model had the highest accuracies in both training set and the test set(96.57%and 95.33%),which area under curve(AUC)values were 0.934 and 0.923,and specificities were 81.64%and 80.52%,and sensitivities were 90.25%and 88.71%,respectively.The results of consistency test indicated that the assembled model had the best classification consistency(Kappa=0.856,P<0.001)in the constructed diagnostic model for pulmonary nodule,which was the best-performing model.Conclusion:The deep learning technique based on CT radiomics has a certain feasibility in improving the diagnostic accuracy for pulmonary nodules,and the machine learning model that is included in this study has favorable predictive value in diagnosing pulmonary nodules.In them,the assembled model that is constructed on the basis of ResNet50,DenseNet121,Inception_V3,and VGG19 has better classification ability.
7.The Scientific Connotation of the Pathogenesis of"Dysfunction of Spleen Transforming Essences"in Colorectal Cancer Based on"Epigenetic-Reprogramming of Glucose Metabolism"
Xiumei FAN ; Wenbo HUANG ; Xueke LI ; Fengming YOU ; Fang LI ; Chong XIAO
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(2):460-465
The key link to colorectal cancer progression is that epigenetic derangements promote reprogramming of glucose metabolism.Based on many studies on the relationship between spleen being the origin of acquired constitution and epigenetics,spleen qi dispersing essence and glucose metabolism,combined with the extensive experience of traditional Chinese medicine in the treatment of colorectal cancer and the accumulation of researches on glucose metabolism,it is believed that the"epigenetic-reprogramming of glucose metabolism"pathology of colorectal cancer is the microscopic essence of the key pathogenesis of"dysfunction of spleen transforming essences".The"promoting spleen and dispersing essences"method means that"promoting spleen"to reverse epigenetic derangements and"dispersing essences"to regulate reprogramming of glucose metabolism was put forward to treat colorectal cancer.Look forward to enrich the scientific connotation of the pathogenesis of"dysfunction of spleen transforming essences",new ideas and potential empirical basis for traditional Chinese medicine intervention in colorectal cancer were provided.
8.Interaction between renal function and body mass index on all-cause mortality risk in patients with type 2 diabetes mellitus in communities in Jiangsu Province
Mengxia LI ; Jialiu HE ; Hao YU ; Xikang FAN ; Jie YANG ; Yu QIN ; Chong SHEN ; Yan LU ; Enchun? PAN ; Ran TAO ; Yongqing ZHANG ; Jian SU
Chinese Journal of Epidemiology 2025;46(1):50-56
Objective:To investigate the association of the interaction and combined effect of renal function and body mass index (BMI) with the risk for all-cause death in patients with type 2 diabetes mellitus (T2DM) in communities of Jiangsu Province.Methods:The study subjects were from the Comprehensive Research Project of Diabetes Prevention and Control conducted in Jiangsu from December 2013 to January 2014, and follow up was conducted for them until September 30, 2023. A total of 20 025 subjects were included in the study. Cox proportional hazards regression model was used to analyze the association of renal function with risk for death in T2DM patients, and the association of interaction between renal function and BMI and their combined effect with all-cause death risk in T2DM patients.Results:In the follow up for 198 370 person-years, a total of 4 459 deaths were recorded. Cox proportional hazards regression model analysis showed that renal dysfunction was associated with 71% risk of all-cause mortality in all T2DM patients [hazard ratio ( HR) =1.71, 95% CI: 1.59-1.84], as well as in all BMI subgroups. Likelihood ratio test indicated an interaction between renal function and BMI (interaction for P=0.030). Compared with patients with normal renal function and normal BMI, those with normal renal function and over weight or obesity had a lower risk of all-cause mortality, and those with renal dysfunction and low weight had the highest risk for death ( HR=2.78, 95% CI: 1.87-4.14). Conclusions:There is association of interaction between renal function and BMI with all-cause mortality in T2DM patients. T2DM patients with renal dysfunction and low body weight had significant higher risk for death.
9.Analysis on national supervision and sample inspection of disposable sterile surgical drapes
Yu-peng SUN ; Qing-yu LI ; Fan LI ; Ze-chen LIN ; Xue-chong LIU ; Bo ZHANG
Chinese Medical Equipment Journal 2025;46(5):66-72
The existing relevant standards and registration of disposable sterile surgical drapes were introduced,and four times of national supervision and sample inspection of disposable sterile surgical drapes from 2017 to 2023 were described.The unqualified items found in the supervision and sample inspection were analyzed,the exploratory research projects carried out were summarized and other problems encountered during the sample inspection were pointed out.Relevant enterprises were suggested to strengthen the implementation of industry standards,take seriously the product material identification information,clearly limit the raw materials used and standardize the product registration name.References were provided for the industrial supervision and development of disposable sterile surgical drapes.[Chinese Medical Equipment Journal,2025,46(5):66-72]
10.A machine learning-based trajectory predictive modeling method for manual acupuncture manipulation.
Jian KANG ; Li LI ; Shu WANG ; Xiaonong FAN ; Jie CHEN ; Jinniu LI ; Wenqi ZHANG ; Yuhe WEI ; Ziyi CHEN ; Jingqi YANG ; Jingwen YANG ; Chong SU
Chinese Acupuncture & Moxibustion 2025;45(9):1221-1232
OBJECTIVE:
To propose a machine learning-based method for predicting the trajectories during manual acupuncture manipulation (MAM), aiming to improve the precision and consistency of acupuncture practitioner' operation and provide the real-time suggestions on MAM error correction.
METHODS:
Computer vision technology was used to analyze the hand micromotion when holding needle during acupuncture, and provide a three-dimensional coordinate description method of the index finger joints of the holding hand. Focusing on the 4 typical motions of MAM, a machine learning-based MAM trajectory predictive model was designed. By integrating the changes of phalangeal joint angle and hand skeletal information of acupuncture practitioner, the motion trajectory of the index finger joint was predicted accurately. Besides, the roles of machine learning-based MAM trajectory predictive model in the skill transmission of acupuncture manipulation were verified by stratified randomized controlled trial.
RESULTS:
The performance of MAM trajectory predictive model, based on the long short-term memory network (LSTM), obtained the highest stability and precision, up to 98%. The learning effect was improved when the model applied to the skill transmission of acupuncture manipulation.
CONCLUSION
The machine learning-based MAM predictive model provides acupuncture practitioner with precise action prediction and feedback. It is valuable and significant for the inheritance and error correction of manual operation of acupuncture.
Humans
;
Acupuncture Therapy/instrumentation*
;
Machine Learning
;
Adult
;
Male
;
Female

Result Analysis
Print
Save
E-mail