1.Discovery of fernane-type triterpenoids from Diaporthe discoidispora using genome mining and HSQC-based SMART technology.
Yajing WANG ; Yongfu LI ; Yan DONG ; Chunyan YU ; Chengwei LIU ; Chang LI ; Yi SUN ; Yuehu PEI
Chinese Journal of Natural Medicines (English Ed.) 2025;23(3):368-376
In this study, we employed a combination of genome mining and heteronuclear single quantum coherence (HSQC)-based small molecule accurate recognition technology (SMART) technology to search for fernane-type triterpenoids. Initially, potential endophytic fungi were identified through genome mining. Subsequently, fine fractions containing various fernane-type triterpenoids were selected using HSQC data collection and SMART prediction. These triterpenoids were then obtained through targeted isolation and identification. Finally, their antifungal activity was evaluated. As a result, three fernane-type triterpenoids, including two novel compounds, along with two new sesquiterpenes and four known compounds were isolated from one potential strain, Diaporthe discoidispora. Their structures were elucidated through analysis of high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) and nuclear magnetic resonance (NMR) spectroscopic data. The absolute configurations were determined using single-crystal X-ray diffraction analysis and electron capture detector (ECD) analysis. Compound 3 exhibited moderate antifungal activity against Candida albicans CMCC 98001 and Aspergillus niger.
Triterpenes/isolation & purification*
;
Antifungal Agents/isolation & purification*
;
Molecular Structure
;
Candida albicans/drug effects*
;
Ascomycota/genetics*
;
Magnetic Resonance Spectroscopy
;
Aspergillus niger/drug effects*
;
Genome, Fungal
;
Microbial Sensitivity Tests
2.Heterogeneity in pancreatic head cancer: prognostic implications of ventral pancreatic and dorsal pancreatic origins
Wenbin LIU ; Yun BIAN ; Chengwei CHEN ; Xiaohan YUAN ; Yixuan SHEN ; Xinyue ZHANG ; Yifei GUO ; Ying LI ; Jieyu YU ; Jianping LU
Chinese Journal of Hepatobiliary Surgery 2025;31(4):284-289
Objective:To investigate the impact of tumor origin (ventral pancreatic origin and dorsal pancreatic origin) on prognosis in patients with pancreatic head cancer.Methods:A retrospective analysis was performed on the clinical data of 150 patients with pancreatic head cancer who received surgical treatment at the First Affiliated Hospital of the Naval Medical University from October 2014 to December 2017. Among these patients, 92 were male and 58 were female, aged (61.2±8.8) years. The 150 patients were divided into two groups based on tumor origin: the ventral pancreatic cancer group ( n=72) and the dorsal pancreatic cancer group ( n=78). A comparative analysis of clinical, pathological, and imaging charac-teristics was conducted between the two groups. Univariate and multivariable Cox proportional hazards models were used to analyze the association between pancreatic head cancer origin and overall survival (OS). Results:Patients with pancreatic head carcinoma arising from the ventral and dorsal pancreas accounted for 48%(72/150) and 52%(78/150) of the study cohort, respectively. Pancreatic head carcinoma arising from the dorsal pancreas were more likely to show pathological features of pancreatic parenchymal atrophy [73.1%(57/78) vs. 47.2%(34/72), χ2=10.49, P=0.001] and pancreatitis [44.9%(35/78) vs. 29.2%(21/72), χ2=3.95, P=0.047]. In contrast, patients with pancreatic head carcinoma arising from the ventral pancreas was more frequently associated with contact with the superior mesenteric artery [25.0%(18/72) vs. 1.3%(1/78), χ2=19.04, P<0.001], perineural invasion [100%(72/72) vs. 88.5%(69/78), χ2=8.84, P=0.003], and positive surgical margins [15.3%(11/72) vs. 2.6%(2/78), χ2=7.65, P=0.006], with all differences statistically significant. The ventral pancreatic cancer group demonstrated cumulative survival rates of 33.2% and 0 at 1-year and 2-year postoperative intervals, respectively, while the dorsal pancreatic cancer group exhibited rates of 56.7% and 24.8% at the corresponding timepoints. Comparison of Kaplan-Meier survival curves between the two groups showed a statistically significant difference ( χ2=6.00, P=0.014). Multivariable Cox proportional hazards analysis identified dorsal pancreatic origin pancreatic head cancer as an independent predictor of increased mortality risk compared to ventral origin tumors ( HR=2.75, 95% CI: 1.52-4.98, P=0.001). Conclusion:The embryonic origin of pancreatic head cancer determines its clinical, pathological, and imaging heterogeneity, and pancreatic head cancer arising from the ventral pancreas demonstrates significantly worse prognostic outcomes compared to dorsal pancreatic origin.
3.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
4.Treatment of trigeminal neuralgia with botulinum toxin type A and cobrotoxin: a case report
Yingying XU ; Shuyang MA ; Ying LI ; Jili BAO ; Zhou XU ; Chengwei GUO ; Jing LIU ; Weifeng LUO
Chinese Journal of Neurology 2025;58(4):426-429
Trigeminal neuralgia is characterized by intense pain in the sensory distribution area of the trigeminal nerve. It can be triggered by non-noxious stimuli such as brushing teeth and washing face. At present, the treatment of trigeminal neuralgia mainly includes oral drugs and surgical treatments. A 92-year-old patient with trigeminal neuralgia was reported. The pain could not be alleviated because the patient was unable to tolerate the side effects of drugs and surgical treatment. Taking into account the onset time and the duration of the curative effect, botulinum toxin type A was combined with cobrotoxin for the treatment of the patient. As a result, the pain symptoms were rapidly alleviated and remained in a relieved state for 8 months. The clinical characteristics of this patient were summarized in this article, and the possible synergistic mechanisms of action of the 2 drugs were discussed. The ultimate objective is to furnish a broader spectrum of alternatives and references for clinical practice.
5.Research Advances in Tetraspanins in Colorectal Cancer
Chengwei LIU ; Kunyang WANG ; Zhen HU ; Yaoping LI
Cancer Research on Prevention and Treatment 2025;52(5):361-367
The tetraspanins are closely associated with the development and therapeutic prognosis of colorectal tumors. These proteins play a role in cell proliferation, metastasis, and invasion, regulate apoptosis and autophagy of colorectal tumor cells. affect immune escape by releasing exosomes, intervening the epithelial-mesenchymal transition process, and altering the tumor microenvironment, and enhance tumor stemness through specific pathways. This paper reviews the mechanisms and current research regarding the status of tetraspanins in colorectal cancer, aiming to improve early diagnosis and providing valuable insights for treatment strategies.
6.CT imaging features of urachal carcinoma
Lina LIN ; Shiyue CHEN ; Lixin YU ; Shuai LI ; Qiang HAO ; Chengwei SHAO ; Xia TIAN
Academic Journal of Naval Medical University 2025;46(7):869-873
Objective To analyze the computed tomography(CT)imaging features of urachal carcinoma and evaluate its diagnostic value.Methods The clinical data of 20 patients with urachal carcinoma confirmed by surgery and pathology,who were admitted to The First Affiliated Hospital of Naval Medical University from Dec.2012 to Dec.2022,were collected.Seventeen of the 20 patients underwent enhanced CT urography and 3 underwent pelvic CT plain scan+enhanced scan.After scanning,multiplanar reconstruction was performed on the post-processing workstation.The general data,clinical symptoms,CT imaging findings,pathological data,and prognosis of the patients were analyzed and summarized.Results The patients included 16 males and 4 females,aged 27 to 75 years old,with a median age of 61.50(41.50,71.25)years old.The tumors were all located in the anterior wall of the bladder,along the urachus,with a maximum diameter of 1.72-5.55 cm and a median maximum diameter of 3.34(2.48,3.71)cm.Fourteen cases had cystic-solid lesions and 6 had solid lesions.In the cystic-solid lesions,9 cases showed the"upper cystic and lower solid"sign on the sagittal plane.Calcification was noted in 17 cases.After enhanced scanning,18 cases showed progressive enhancement,and 2 cases showed"fast in and fast out"enhancement.Tumor invasion extended beyond the urachus and/or bladder muscle layer in 19 cases.At the end of follow-up,3 cases had recurrence,2 had metastasis,5 had no recurrence after surgery,3 died,and 7 were lost to follow-up.Conclusion Urachal carcinoma has certain characteristic manifestations on CT imaging.Reconstructing the sagittal plane with enhanced CT scanning and multiplanner reformation can help preoperative diagnosis and prognostic evaluation of urachal carcinoma.
7.Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality.
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU
Chinese Journal of Medical Instrumentation 2025;49(2):176-180
OBJECTIVE:
To investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT.
RESULTS:
For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant.
CONCLUSION
Different scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
Cone-Beam Computed Tomography/instrumentation*
;
Phantoms, Imaging
;
Particle Accelerators
8.Research Progress of Clinical Quality Control Phantoms for MRI Equipment
Chengwei LI ; Jiao LI ; Hui XU ; Tianrui ZHAO ; Pu ZHANG ; Peng ZHANG ; Zhengshan HUANG ; Jie SUN
Chinese Journal of Medical Imaging 2025;33(6):607-610,617
With the rapid increase of MRI systems in hospitals in China,national multi-sectoral strategies have been put forward to clarify requirements for improving image quality of MRI systems and preventing application risks in clinic.Quality control of MRI systems becomes an important task for regulators as well as hospital radiology departments.The tools used for quality control include imaging performance phantom and specialized function phantom,which can realize detection or calibration for parameters such as high contrast resolution,image uniformity and relaxation time.This article mainly reviews the research progress of the operation principles,common types and clinical applications for these two types of phantoms mentioned above.
9.Strengthening the Construction of Clinical Quality Control System for MRI Equipment to Ensure Their Efficacy in Clinical Application
Hongxia YIN ; Chengwei LI ; Yawen LIU ; Hui XU ; Yu ZHANG ; Zhenchang WANG
Chinese Journal of Medical Imaging 2025;33(6):583-586
With the rapid increase in the ownership of MRI equipment in China,quality control,particularly in clinical usage aspects,has become critically important.For clinical quality control of MRI systems,it is essential to establish comprehensive workflow principles encompassing multiple elements such as personnel,equipment,standards,tools and methodologies.To advance the standardization and widespread adoption of clinical quality control for MRI equipment,efforts must focus on strengthening regulatory frameworks,advancing phantom research,development and enhancing professional expertise.Concurrently,continuous improvements in training programs and supervision mechanisms are necessary to ensure the effective implementation of MRI clinical quality control practices.Furthermore,in the era of digital healthcare,clinical quality assurance for MRI equipment is evolving toward automation and intelligent solutions,providing higher-quality and more efficient assurance for clinical applications.
10.Whole-Body Specific Absorption Rate Measurement Method Based on NIM Calorimetry
Zhengshan HUANG ; Pu ZHANG ; Peng ZHANG ; Chengwei LI ; Jie SUN
Chinese Journal of Medical Imaging 2025;33(6):589-594
Purpose To explore the feasibility and practical value of using National Institute of Metrology(NIM)calorimetry method to measure whole-body specific absorption rate(SAR)values of in-service MRI equipment.Materials and Methods A NIM calorimetry device for measuring whole-body SAR values was developed,SAR values of different MRI devices were measured by NIM calorimetry,and compared with National Electrical Manufacturers Association(NEMA)calorimetry and pulse-energy method to verify the measurement accuracy and applicability of the NIM calorimetry method.Results The NIM calorimetry device developed in this study had reliable performance,and the experimental results indicated the difference in measurement results between NIM calorimetry(1.63 W/kg)and NEMA calorimetry(1.80 W/kg)was within 10%.The difference between the SAR measurement results of multiple MRI devices based on NIM calorimetry(0.46,0.93,0.61 W/kg)and the pulse energy method(0.42,0.89,0.56 W/kg)was within 10%.Conclusion The NIM calorimetry method in this study can accurately measure whole-body SAR values and has applicability.

Result Analysis
Print
Save
E-mail