1.Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis
Peipei LI ; Chengli LI ; Yujun XU ; Xiangmeng HE ; Roberto Blanco SEQUEIROS ; Ming LIU
Korean Journal of Radiology 2025;26(5):498-507
Objective:
To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
Materials and Methods:
In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
Results:
Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
Conclusion
As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
2.Efficacy of transarterial chemoembolization combined with targeted therapy and immunotherapy in treating advanced hepatocellular carcinoma
Jun YANG ; Luyang LI ; Haoming LI ; Tian XIA ; Tao ZHANG ; Meng PU ; Yingbo MA ; Shuhan ZHANG ; Chengli LIU
Journal of Interventional Radiology 2025;34(4):398-402
Objective To discuss the efficacy of transcatheter arterial chemoembolization(TACE)in combination with targeted therapy and immune checkpoint inhibitors for advanced hepatocellular carcinoma(HCC),and to identify the influencing factors.Methods A total of 60 patients with advanced HCC,who were admitted to the Air Force Medical Center of China from January 2016 to December 2022,were enrolled in this study.Thirty patients received TACE combined with targeted therapy and immune checkpoint inhibitors(TACE-L-P group),and the other 30 patients received TACE combined with targeted therapy(TACE-L group).The progression-free survival(PFS),overall survival(OS),disease control rate(DCR),and objective response rate(ORR)were compared between the two groups.Results In the TACE-L group and TACE-L-P group,the median PFS(mPFS)was 7 months and 10 months respectively(P=0.011),the median OS(mOS)was 15.5 months and 29 months respectively(P=0.014).Child-Pugh class B(HR=3.89,95%CI:1.27-11.94,P=0.018)and Barcelona Clinic Liver Cancer(BCLC)stage C(HR=2.83,95%CI:1.32-6.03,P=0.007)were the independent risk factors for OS,while micro wave ablation(HR=0.21,95%CI:0.07-0.63,P=0.005)and TACE-L-P(HR=0.09,95%CI:0.03-0.3,P=0.001)were the independent protection factors for OS.Besides,elevated bilirubin level(HR=1.03,95%CI:1-1.06,P=0.032)and elevated gamma-glutamyl transferase(GGT)level(HR=1.01,95%CI:1-1.01,P=0.002)were the independent risk factors for disease progression,and TACE-L-P(HR=0.27,95%CI:0.09-0.79,P=0.017)was the independent protection factor for disease progression.The ORR and DCR in TACE-L-P group were remarkably higher than those in TACE-L group,which were 43.4%vs 13.3%and 63.4%vs 23.3%respectively,the differences between the two groups were statistically significant(both P<0.05).Conclusion In treating advanced HCC,TACE combined with targeted therapy and immune checkpoint inhibitors is superior to TACE combined with targeted therapy in therapeutic efficacy.
3.Comparison of different prediction models based on machine learning algorithms for the risk of poor postoperative wound healing in patients with spinal tuberculosis
Jinglian WEN ; Wei TANG ; Chengli WU ; Run LI ; Qing YE ; Guoxuan PENG
Chongqing Medicine 2025;54(11):2552-2558
Objective To analyze risk factors for poor postoperative wound healing in spinal tuberculo-sis patients and construct prediction models along with a risk scoring table using machine learning algorithms,providing references for early prevention and management.Methods Clinical data from 420 spinal tuberculo-sis patients treated at four tertiary hospitals in Guizhou Province between January 2017 and February 2024 were retrospectively analyzed.Risk factors were identified through univariate and multivariate analyses.Logis-tic regression,random forest,and support vector machine prediction models were constructed.Model perform-ance was evaluated using receiver operating characteristic(ROC)curves,precision,recall,accuracy,and F1-score.A risk prediction scoring table for poor postoperative wound healing was subsequently developed.Re-sults Among the 420 patients with spinal tuberculosis,132 experienced poor postoperative wound healing,with an incidence rate of 31.43%.Logistic regression analysis showed that BMI≤18.5 kg/m2,preoperative albumin≤30 g/L,combined surgical procedure,intraoperative blood loss>1 000 mL,direct bilirubin>8 μmol/L within 3 days after surgery,neutrophil count≤75×109/L within 3 days after surgery,and postopera-tive drainage volume>500 mL were risk factors for poor postoperative wound healing(P<0.05).In the comparison among the three risk prediction models constructed based on machine learning algorithms,the ran-dom forest model demonstrated the best predictive performance.A risk prediction scoring table was construc-ted based on the partial regression coefficients from the multivariate analysis,with a total score range from 0 to 11 points.A score>6 points indicated an increased risk of poor postoperative wound healing.The area un-der the ROC curve(AUC)for this risk prediction scoring table was 0.846(95%CI:0.769 to 0.923),indica-ting good predictive performance.Conclusion The random forest model based on machine learning algorithms and the risk prediction scoring table have certain predictive value for assessing the risk of poor postoperative wound healing in patients with spinal tuberculosis;they can assist healthcare professionals in early identifica-tion of high-risk patients.
4.Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis
Peipei LI ; Chengli LI ; Yujun XU ; Xiangmeng HE ; Roberto Blanco SEQUEIROS ; Ming LIU
Korean Journal of Radiology 2025;26(5):498-507
Objective:
To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
Materials and Methods:
In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
Results:
Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
Conclusion
As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
5.Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis
Peipei LI ; Chengli LI ; Yujun XU ; Xiangmeng HE ; Roberto Blanco SEQUEIROS ; Ming LIU
Korean Journal of Radiology 2025;26(5):498-507
Objective:
To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
Materials and Methods:
In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
Results:
Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
Conclusion
As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
6.Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis
Peipei LI ; Chengli LI ; Yujun XU ; Xiangmeng HE ; Roberto Blanco SEQUEIROS ; Ming LIU
Korean Journal of Radiology 2025;26(5):498-507
Objective:
To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
Materials and Methods:
In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
Results:
Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
Conclusion
As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
7.Feasibility of Multiparameter MRI-Guided Percutaneous Biopsy for Central Lung Lesions With Atelectasis
Peipei LI ; Chengli LI ; Yujun XU ; Xiangmeng HE ; Roberto Blanco SEQUEIROS ; Ming LIU
Korean Journal of Radiology 2025;26(5):498-507
Objective:
To prospectively evaluate the feasibility, accuracy, and safety of multiparameter MRI-guided percutaneous biopsy using a 1T open MRI scanner for evaluating suspicious centrally located lung lesions with associated post-obstructive atelectasis.
Materials and Methods:
In this single-center study, MRI-guided percutaneous coaxial cutting biopsy was performed for 107 suspicious central lung lesions with associated post-obstructive atelectasis in 107 patients between July 2015 and December 2020. A fast T2-weighted imaging (T2WI)-turbo spin echo (TSE) sequence and an enhanced fast T1-weighted imaging (T1WI)-TSE sequence were used to identify, localize, and biopsy lung lesions, and diffusion-weighted imaging (DWI) was used as a supplementary sequence for identifying the lesion location. The final diagnosis was confirmed by surgical histopathology or clinical follow-up for a minimum of 24 months. The sensitivity, specificity, and accuracy for diagnosing lung malignancies were calculated, and the complications were recorded for each case.
Results:
Using multiparameter MRI, central lung lesions could be clearly distinguished from post-obstructive atelectasis in 96 patients (89.7%). The sensitivity, specificity, and accuracy of MRI-guided percutaneous biopsy for diagnosing lung malignancy was 97.0% (98/101), 100% (6/6), and 97.2% (104/107), respectively. Self-limited hemoptysis occurred in three patients. Pneumothorax occurred in five patients, of which none required pleural drainage. No serious procedure-related complications were observed.
Conclusion
As a technology that does not involve ionizing radiation, multiparameter MRI-guided percutaneous coaxial cutting biopsy is a safe and accurate diagnostic technique for evaluating centrally located lung lesions associated with post-obstructive atelectasis.
8.Chinese expert consensus on the evaluation of allergen-specific immunotherapy outcomes(Wuhan, 2025).
Yuqin DENG ; Xi LUO ; Zhuofu LIU ; Shuguang SUN ; Jing YE ; Tiansheng WANG ; Jianjun CHEN ; Meiping LU ; Yin YAO ; Ying WANG ; Wei ZHOU ; Bei LIU ; Qingxiang ZENG ; Yuanteng XU ; Qintai YANG ; Yucheng YANG ; Feng LIU ; Chengli XU ; Yanan SUN ; Haiyu HONG ; Haibo YE ; Liqiang ZHANG ; Fenghong CHEN ; Huabin LI ; Hongtian WANG ; Yuncheng LI ; Wenlong LIU ; Yu XU ; Hongfei LOU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1075-1085
Allergen-specific immunotherapy(AIT) remains the only therapeutic approach with the potential to modify the natural course of allergic rhinitis(AR). Nevertheless, considerable inter-individual variability exists in patients'responses to AIT. To facilitate more reliable assessment of treatment efficacy, the China Rhinopathy Research Cooperation Group(CRRCG) convened young and middle-aged nasal experts in China to formulate the present consensus. The recommended subjective outcome measures for AIT comprise symptom scores, medication scores, combined symptom and medication scores, quality-of-life assessments, evaluation of disease control, and assessment of comorbidities. Objective indicators may supplement these measures. Currently available objective approaches include skin prick testing, nasal provocation testing, and allergen exposure chambers. However, these methods remain constrained by practical limitations and are not yet appropriate for routine implementation in clinical efficacy evaluation. In addition, several biomarkers, including sIgE and the sIgE/tIgE ratio, sIgG4, serum IgE-blocking activity, IgA, cytokines and chemokines, as well as immune cell surface molecules and their functional activity, have been shown to have associations with AIT outcomes. While these biomarkers may complement subjective assessments, they are subject to significant limitations. Consequently, large-scale multicenter trials and real-world evidence are required to strengthen the evidence base. The present consensus underscores the necessity of integrating patients'subjective experiences with objective testing throughout the treatment process, thereby providing a more comprehensive and accurate framework for efficacy evaluation. Looking forward, future investigations should prioritize the incorporation of multi-omics data and artificial intelligence methodologies, which hold promise for overcoming current limitations in assessment strategies and for advancing both the standardization and personalization of AIT.
Humans
;
Allergens/immunology*
;
China
;
Consensus
;
Desensitization, Immunologic
;
Immunoglobulin E
;
Quality of Life
;
Rhinitis, Allergic/therapy*
;
Treatment Outcome
;
East Asian People
9.Forty years' development of MR-guided intervention in China:Evolving from technical challenges to precision medicine paradigm
Chinese Journal of Medical Imaging Technology 2025;41(8):1437-1442
MR-guided intervention,having evolved over four decades,has transitioned from early exploratory phase in laboratories to becoming a core technology in precision interventional medicine.Leveraging its advantages of being radiation-free,high soft tissue resolution and functional imaging capabilities,MR intervention has redefined the paradigm of precise diagnosis and treatment in interventional medicine.This article systematically reviewed its developmental journey,analyzed the underlying logic of device development and technological breakthroughs,summarized the multidimensional expansion of clinical applications,examined existing challenges,and envisions future directions,in order to provide systematic references for development of the discipline and drive the technology toward even higher levels.
10.Development and application of a plasma ablation device
Minghui CHEN ; Tong WU ; Yi SHAO ; Fugang LI ; Liuxiao CHEN ; Jing ZHOU ; Hongwang WANG ; Chengli SONG
Chinese Journal of Medical Physics 2025;42(6):806-813
Although low temperature plasma ablation technology has significant advantages in clinical applications,its poor stability,high power consumption and thermal injuries to the tissues are still key factors limiting its widespread use.To address these issues,a device that uses bipolar pulses to excite plasma is developed,and it can flexibly adjust its output voltage,frequency and duty cycle,effectively reducing breakdown voltage and power consumption.By conducting simulation and saltwater discharge experiments,the excitation process of plasma is elaborated in detail.Meanwhile,the effects of two different pulse excitation modes on plasma excitation are discussed and compared.The results show that the bipolar pulse excitation mode is advantageous in reducing discharge current and breakdown voltage,and shortening the formation time of the vapor layer,which effectively relieves thermal injuries to the tissues.Finally,the broad application potential of the plasma ablation device is demonstrated in plasma ablation experiments which are conducted at different voltages,with pork as the experimental material.The study provides a new theoretical basis and practical guidance for the application of plasma ablation technology in minimally invasive surgery.

Result Analysis
Print
Save
E-mail