1.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
2.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
3.The impact of image quality on the diagnostic performance of CT-derived fractional flow reserve
Qingchao MENG ; Yang GAO ; Na ZHAO ; Lei SONG ; Hongjie HU ; Tao JIANG ; Wenqiang CHEN ; Feng ZHANG ; Lin LI ; Li XU ; Dumin LI ; Lijuan FAN ; Chaowei MU ; Jingang CUI ; Yunqiang AN ; Bo XU ; Bin LYU
Chinese Journal of Radiology 2023;57(2):150-156
Objective:To explore the impact of coronary CT angiography (CCTA) image quality and related factors on the diagnostic performance of CT-derived fractional flow reserve (CT-FFR).Methods:Based on the CT-FFR CHINA trial, the prospective multicenter trial enrolled patients with suspected coronary artery disease who underwent CCTA, CT-FFR and FFR measurement. The subjective and objective assessments of CCTA image were performed on a per-vessel level. The objective assessments included the enhancement degree of coronary artery, the signal-to-noise ratio (SNR) of the aortic root. We used χ 2 test and DeLong test to compare the diagnostic performance of CT-FFR with FFR as the reference standard in different subjective groups (non-artifact vs. artifact), enhancement degree of coronary artery groups (≤400 vs. 401-500 vs.>500 HU), SNR of the aortic root groups (≤16.9 vs.>16.9), body mass index (BMI) groups (<25 kg/m 2 vs.≥25 kg/m 2) and heart rate groups (<75 bpm vs.≥75 bpm). FFR and CT-FFR values≤0.80 was identified as myocardial ischemia. Results:The study enrolled 317 patients with 366 vessels. All target vessels in CCTA images were successfully analyzed by CT-FFR. The accuracy, sensitivity, specificity, positive predictive value, negative predictive value and AUC of the non-artifact group were 90.45%, 86.75%, 93.10%, 90.00%, 90.76% and 0.928, respectively, and those of the artifact group were 83.23%, 87.21%, 79.01%, 81.52%, 85.33% and 0.869, respectively. The differences in accuracy and specificity were statistically significant (χ 2=4.23, P=0.040; χ 2=8.55, P=0.003). The diagnostic efficacy of CT-FFR had no statistically significant differences among different objective groups (all P>0.05). Conclusions:The artifact of CCTA image has an effect on CT-FFR in the diagnosis of myocardial ischemia. The degree of vascular enhancement, SNR, BMI, and heart rate have no significant effect on the diagnostic performance of CT-FFR.
4.The clinical study of middle and old age patients with knee osteoarthritis treated by abdominal acupuncture combined with sodium hyaluronate injected in intraarticular
Chengmao JI ; Xiaohua YUAN ; Chaowei CUI ; Jiawei GUO ; Shaohua ZHOU ; Yanzhen DENG
Chinese Journal of Primary Medicine and Pharmacy 2017;24(10):1454-1457
Objective To explore the clinical efficacy of knee osteoarthritis treated by abdominal acupuncture combined with sodium hyaluronate injected in intraarticular.Methods 120 patients with knee osteoarthritis were randomly divided into observation group and control group,60 patients in each group.The observation group was treated by abdominal acupuncture combined with sodium hyaluronate injected in intraarticular.The control group was treated with intraarticular injection of sodium hyaluronate alone.Results After a follow up of 6 months, the total effective rate of the treatment group was 95.00%,which was higher than 78.33% of the control group, the difference was statistically significant (x2=7.21,P<0.01).Conclusion Abdominal acupuncture combined with intraarticular injection of sodium hyaluronate is a good way to treat middle and old age patients with knee osteoarthritis.
5.A meta-analysis of microRNA-149, microRNA-499 gene polymorphism and susceptibility to hepatocellular carcinoma
Lixia YE ; Chaowei FU ; Feng JIANG ; Yuanxia CUI ; Wei MENG
Chinese Journal of Preventive Medicine 2016;50(5):445-450
Objective To investigate the relationship between microRNA-149 (rs2292832),microRNA-499 (rs2292832) polymorphism and hepatocellular carcinoma susceptibility by meta-analysis.Methods We used "hepatocellular carcinoma/HCC","miRNA-149/miR-149/microRNA-149",and "miRNA-499/miR-499/microRNA-499" as key words to search papers in databases including China National Knowledge Internet (CNKI),Chinese BioMedical Literature (CBM),Vip Citation Databases (VIP),Wanfang,PubMed and Web of Science databases,and collected the case-control studies on the association of rs2292832 or rs3746444 and the susceptibility to hepatocellular carcinoma from updated to May 31st 2015.Data were extracted by two independent reviewers and pooled OR with 95% CI was calculated.A bioinformatics analysis was further conducted.Results A total of 13 research papers were collected,and 5 studies for rs2292832 and 12 studies for rs3746444.1 096 cases and 1 701 controls were included for rs2292832 and 3 117 cases and 4 126 controls were included for rs3746444.Meta-analysis failed to detect associations between rs2292832,rs3746444 and susceptibility to hepatocellular carcinoma under each genetic model tested and alleles of OR(95% CI) were 0.99(0.78-1.28) and 1.11(0.88-1.40).However,subgroup analysis showed that rs3746444 C allele seem to be associated with an increased hepatocellular carcinoma risk in both researches which had more than 400 samples and which used more accurate genotyping methods,and OR(95%C1) were 1.32(1.02-1.70) and 1.34(1.09-1.66),respectively.Furthermore,bioinformatics analysis also showed that the expression of both SNPs were down-regulated in HepG2 cells and indicated possible functional effects on gene transcription.Cochran's Q test indicated that there was the heterogeneity among the studies included.Conclusions No significant association was found between rs2292832,rs3746444 and susceptibility to hepatocellular carcinoma,but subgroup study indicated C allele might be associated with increased hepatocellular carcinoma risk for rs3746444.Bioinformatics analysis indicated that the two SNPs might have possible influence on gene transcription.
6.A meta-analysis of microRNA-149, microRNA-499 gene polymorphism and susceptibility to hepatocellular carcinoma
Lixia YE ; Chaowei FU ; Feng JIANG ; Yuanxia CUI ; Wei MENG
Chinese Journal of Preventive Medicine 2016;50(5):445-450
Objective To investigate the relationship between microRNA-149 (rs2292832),microRNA-499 (rs2292832) polymorphism and hepatocellular carcinoma susceptibility by meta-analysis.Methods We used "hepatocellular carcinoma/HCC","miRNA-149/miR-149/microRNA-149",and "miRNA-499/miR-499/microRNA-499" as key words to search papers in databases including China National Knowledge Internet (CNKI),Chinese BioMedical Literature (CBM),Vip Citation Databases (VIP),Wanfang,PubMed and Web of Science databases,and collected the case-control studies on the association of rs2292832 or rs3746444 and the susceptibility to hepatocellular carcinoma from updated to May 31st 2015.Data were extracted by two independent reviewers and pooled OR with 95% CI was calculated.A bioinformatics analysis was further conducted.Results A total of 13 research papers were collected,and 5 studies for rs2292832 and 12 studies for rs3746444.1 096 cases and 1 701 controls were included for rs2292832 and 3 117 cases and 4 126 controls were included for rs3746444.Meta-analysis failed to detect associations between rs2292832,rs3746444 and susceptibility to hepatocellular carcinoma under each genetic model tested and alleles of OR(95% CI) were 0.99(0.78-1.28) and 1.11(0.88-1.40).However,subgroup analysis showed that rs3746444 C allele seem to be associated with an increased hepatocellular carcinoma risk in both researches which had more than 400 samples and which used more accurate genotyping methods,and OR(95%C1) were 1.32(1.02-1.70) and 1.34(1.09-1.66),respectively.Furthermore,bioinformatics analysis also showed that the expression of both SNPs were down-regulated in HepG2 cells and indicated possible functional effects on gene transcription.Cochran's Q test indicated that there was the heterogeneity among the studies included.Conclusions No significant association was found between rs2292832,rs3746444 and susceptibility to hepatocellular carcinoma,but subgroup study indicated C allele might be associated with increased hepatocellular carcinoma risk for rs3746444.Bioinformatics analysis indicated that the two SNPs might have possible influence on gene transcription.

Result Analysis
Print
Save
E-mail