5.Postprocedural Outcomes and Risk Factors for Arrhythmias Following Transcatheter Closure of Congenital Perimembranous Ventricular Septal Defect: A Single-center Retrospective Study.
Li-Jian ZHAO ; Bo HAN ; Jian-Jun ZHANG ; Ying-Chun YI ; Dian-Dong JIANG ; Jian-Li LYU
Chinese Medical Journal 2017;130(5):516-521
BACKGROUNDCurrently, transcatheter closure of perimembranous ventricular septal defect (pmVSD) is a widely accepted therapeutic modality. However, arrhythmias, especially postprocedural heart blocks, are a concern and outcomes are not very clear. This study explored the outcomes and risk factors of arrhythmias associated with transcatheter device closure of pmVSD.
METHODSA total of 395 patients diagnosed with pmVSD who successfully underwent transcatheter intervention between January 2010 and December 2015 in our center were retrospectively reviewed. Electrocardiographic data before and after the procedure were collected and analyzed. We first evaluated the potential risk factors including gender, age, weight, inlet and outlet diameters of defect, subaortic rim length, occluder size, corrected occluder size into body surface area, fluoroscopy time, presence of aneurysm, and deployment position. We compared the potential risk factors between arrhythmia and nonarrhythmia groups using univariate analysis, followed by logistic analysis for independent risk factors.
RESULTSVarious arrhythmias were detected in 95 cases (24.1%) following transcatheter closure procedure. Logistic regression analysis revealed that eccentric (odds ratio [OR] 2.9, 95% confidence interval [CI]: 1.2-7.2) and large occluders (OR 2.0, 95% CI: 1.6-2.5), as well as long fluoroscopy time (OR 1.1, 95% CI: 1.1-1.2), were correlated with postprocedural arrhythmia. During 35.5 months (range: 9-80 months) of follow-up, most of the patients (74 out of 95) reverted to normal heart rhythm.
CONCLUSIONSThe mid-term outcome of patients with arrhythmias after transcatheter closure of pmVSD was satisfactory as most of the patients recovered normal rhythm. Eccentric, large device and long fluoroscopy time increase the risk of arrhythmias after transcatheter closure of pmVSD.
Arrhythmias, Cardiac ; diagnosis ; etiology ; Cardiac Catheterization ; adverse effects ; Cardiac Surgical Procedures ; adverse effects ; Child ; Child, Preschool ; Electrocardiography ; Female ; Heart Septal Defects, Ventricular ; physiopathology ; surgery ; Humans ; Male ; Retrospective Studies ; Risk Assessment ; Risk Factors ; Septal Occluder Device ; adverse effects ; Treatment Outcome
7.Comparison of Outcomes of Transcatheter and Surgical Procedure in Perimembranous Ventricular Septal Defect Patients with Tricuspid Regurgitation.
Xiao Ke SHANG ; Liang ZHONG ; Rong LU ; Gang Cheng ZHANG ; Mei LIU ; Qun Shan SHEN ; Xin ZHOU ; Chang Yu QIN ; Hong Mei ZHOU
Annals of the Academy of Medicine, Singapore 2016;45(7):322-325
Adolescent
;
Adult
;
Cardiac Catheterization
;
economics
;
methods
;
Cardiac Surgical Procedures
;
economics
;
methods
;
Cardiac Valve Annuloplasty
;
Child
;
China
;
epidemiology
;
Echocardiography
;
Female
;
Heart Septal Defects, Ventricular
;
complications
;
diagnostic imaging
;
surgery
;
Humans
;
Length of Stay
;
statistics & numerical data
;
Male
;
Operative Time
;
Postoperative Complications
;
epidemiology
;
Septal Occluder Device
;
Tricuspid Valve Insufficiency
;
complications
;
diagnostic imaging
;
surgery
;
Young Adult
8.Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery.
Sak LEE ; Seung Hyun LEE ; Byung Chul CHANG ; Jae Kwang SHIM
Yonsei Medical Journal 2015;56(4):913-920
PURPOSE: We compared the efficacy of postoperative hemodynamic goal-directed therapy (GDT) using a pulmonary artery catheter (PAC) and bioreactance-based noninvasive cardiac output monitoring (NICOM) in patients with atrial fibrillation undergoing valvular heart surgery. MATERIALS AND METHODS: Fifty eight patients were randomized into two groups of GDT with common goals to maintain a mean arterial pressure of 60-80 mm Hg and cardiac index > or =2 L/min/m2: the PAC group (n=29), based on pulmonary capillary wedge pressure, and the NICOM group (n=29), based on changes in stroke volume index after passive leg raising. The primary efficacy variable was length of hospital stay. Secondary efficacy variables included resource utilization including vasopressor and inotropic requirement, fluid balance, and major morbidity endpoints. RESULTS: Patient characteristics and operative data were similar between the groups, except that significantly more patients underwent double valve replacement in the NICOM group. The lengths of hospital stay were not different between the two groups (12.2+/-4.8 days vs. 10.8+/-4.0 days, p=0.239). Numbers of patients requiring epinephrine (5 vs. 0, p=0.019) and ventilator care >24 h (6 vs. 1, p=0.044) were significantly higher in the PAC group. The PAC group also required significantly larger amounts of colloid (1652+/-519 mL vs. 11430+/-463 mL, p=0.004). CONCLUSION: NICOM-based postoperative hemodynamic GDT showed promising results in patients with atrial fibrillation undergoing valvular heart surgery in terms of resource utilization.
Aged
;
Aged, 80 and over
;
Cardiac Output/*physiology
;
Cardiac Surgical Procedures/*methods
;
Catheterization, Swan-Ganz
;
Female
;
Goals
;
Heart Valves/*surgery
;
Hemodynamics
;
Humans
;
Length of Stay/*statistics & numerical data
;
Male
;
Middle Aged
;
Monitoring, Intraoperative/methods
;
Monitoring, Physiologic/methods
;
Postoperative Complications/epidemiology/prevention & control
;
Postoperative Period
9.Advantages and limitations of fetal cardiac intervention.
Hongyu DUAN ; Kaiyu ZHOU ; Yimin HUA
Chinese Journal of Pediatrics 2014;52(1):65-68
Animals
;
Aortic Valve
;
surgery
;
Aortic Valve Stenosis
;
congenital
;
therapy
;
Balloon Valvuloplasty
;
methods
;
Cardiac Surgical Procedures
;
adverse effects
;
methods
;
Catheterization
;
adverse effects
;
methods
;
Female
;
Fetal Diseases
;
therapy
;
Fetal Heart
;
surgery
;
Heart Defects, Congenital
;
therapy
;
Humans
;
Postoperative Complications
;
epidemiology
;
Pregnancy
;
Pregnancy Trimester, Second
;
Ultrasonography, Interventional
;
methods
10.Preliminary study of a new heart valve prostheses implanted with minimally invasive techniques: pulsatile-flow testing in vitro.
Jinglong TANG ; Shuo WANG ; Li LIU ; Jian WANG ; Chunren WANG
Journal of Biomedical Engineering 2013;30(1):166-169
The aim of this study was to investigate the pulsatile-flow performance in vitro of a new heart valve prostheses implanted with minimally invasive techniques (HVPMIT). Three HVPMITs were tested valves and another three original biological heart valve prostheses acted as reference valves. The pulsatile-flow parameters (including mean pressure drop, regurgitant percentage of stroke volume, and effective orifice area) were tested in a pulse duplicator according to the methods listed in ISO5840-2005 and GB 12279-2008. The results demonstrated that the regurgitant percentage of stroke volume of tested valves was up to 13%. It was significantly higher than that of the reference valves. This result suggested that paravalvular leakage had occurred in the tested valves. It was found in the further analysis that because HVPMIT was not sewn into the heart tissue when the HVPMIT was implanted in vivo and there was not a sewing ring in the HVPMIT, when tested valves were fixed in the pulse duplicator, some gaps might exist between the stent of HVPMIT and the fix gasket, and the paravalvular leakage could therefore take place through these gaps. This study demonstrated that there are significant differences in the shape, structure, fixation in vivo and clinical operational methods between HVPMIT and original biological heart valve prostheses. It is necessary to establish new test methods which adapt for HVPMIT to evaluate its pulsatile-flow performance according to its own features.
Animals
;
Cardiac Catheterization
;
Heart Valve Prosthesis
;
Heart Valve Prosthesis Implantation
;
adverse effects
;
instrumentation
;
methods
;
Minimally Invasive Surgical Procedures
;
methods
;
Prosthesis Design
;
Pulsatile Flow

Result Analysis
Print
Save
E-mail