1.Research progress of air-to-ground transport devices for patients with serious injury
Mengru YU ; Jia WANG ; Peng DU ; Linyuan ZHANG ; Canhua XU ; Hongbing LU
China Medical Equipment 2025;22(7):167-171
The air-ground transfer device for patients with serious injury is one kind of medical equipment and system that can realize the safe and efficient transfer for patients with serious injury between the air and the ground under scenarios of emergency medical rescue,which plays an important role in the process of aviation rescue.At present,a variety of air-to-ground transport devices for patients with serious injury have been developed abroad,such as the trauma life support and transportation system of United States,the medical transport aircraft of Israel and so on.In China,it has also been developed,such as general-purpose airborne stretcher supports,life support system for patients with serious injury in moving,cross-platform and etc..However,there are still many challenges in current research and development of air-to-ground transfer devices,including technical stability,intelligent level,the application of new materials and so on.Based on this,this paper systematically reviewed the domestic and international development status of air-to-ground transport devices for patients with serious injury,and analyzed the facing problems and technical challenges of these devices,and discussed their development trends in future.Through the research and analysis for existing devices,this study aimed to provide references for the research and development of air-to-ground transport devices for patients with serious injury,so as to improve the efficiency and quality of emergency medical rescue.
2.Design and implementation of aviation transport stretcher for severely injured patients
Jia WANG ; Peng DU ; Linyuan ZHANG ; Yeqin SUN ; Zongmin WEI ; Mengru YU ; Canhua XU ; Hongbing LU
China Medical Equipment 2025;22(9):167-172
Objective:To develop an air transfer stretcher for severely injured patients,so as to meet the requirements of severely injured patients for rapid transport of aviation medical treatment.Methods:The guide rails of hatch of mainstream civil airliner models were analyzed through investigation.Based on the principles of modularization,integration and intelligence,a highly universal and portable aviation stretcher with the functions of rapid transport and life support was designed and developed.The design of the stretcher was verified through simulation analysis and calculation,as well as tests in laboratory,which should meet the requirements of the standards from China Civil Aviation Regulations(CCAR)-25.Results:The results of simulation analysis and tests of laboratory showed that the aviation transport stretcher,and the strength and stiffness of its structure reached to requirement of CCAR-25 standard,which was suit to the portable aviation evacuation of severely injured patients on civil airliners,and the rapid transfer between air and ground.It has the function of supporting life,and the aviation transport stretcher with high universality and convenience can enhance the safety and rescue capability of aviation evacuation system of medical treatment of aviation.Conclusion:The portable aviation stretcher with high-versatility that was researched and developed by this study can effectively solve the problems of life support,injury monitoring,and emergently rescue and treatment during the transport for severely injured patients,which improve the support ability of air-ground transportation for severely injured patients.
3.Research progress of air-to-ground transport devices for patients with serious injury
Mengru YU ; Jia WANG ; Peng DU ; Linyuan ZHANG ; Canhua XU ; Hongbing LU
China Medical Equipment 2025;22(7):167-171
The air-ground transfer device for patients with serious injury is one kind of medical equipment and system that can realize the safe and efficient transfer for patients with serious injury between the air and the ground under scenarios of emergency medical rescue,which plays an important role in the process of aviation rescue.At present,a variety of air-to-ground transport devices for patients with serious injury have been developed abroad,such as the trauma life support and transportation system of United States,the medical transport aircraft of Israel and so on.In China,it has also been developed,such as general-purpose airborne stretcher supports,life support system for patients with serious injury in moving,cross-platform and etc..However,there are still many challenges in current research and development of air-to-ground transfer devices,including technical stability,intelligent level,the application of new materials and so on.Based on this,this paper systematically reviewed the domestic and international development status of air-to-ground transport devices for patients with serious injury,and analyzed the facing problems and technical challenges of these devices,and discussed their development trends in future.Through the research and analysis for existing devices,this study aimed to provide references for the research and development of air-to-ground transport devices for patients with serious injury,so as to improve the efficiency and quality of emergency medical rescue.
4.Design and implementation of aviation transport stretcher for severely injured patients
Jia WANG ; Peng DU ; Linyuan ZHANG ; Yeqin SUN ; Zongmin WEI ; Mengru YU ; Canhua XU ; Hongbing LU
China Medical Equipment 2025;22(9):167-172
Objective:To develop an air transfer stretcher for severely injured patients,so as to meet the requirements of severely injured patients for rapid transport of aviation medical treatment.Methods:The guide rails of hatch of mainstream civil airliner models were analyzed through investigation.Based on the principles of modularization,integration and intelligence,a highly universal and portable aviation stretcher with the functions of rapid transport and life support was designed and developed.The design of the stretcher was verified through simulation analysis and calculation,as well as tests in laboratory,which should meet the requirements of the standards from China Civil Aviation Regulations(CCAR)-25.Results:The results of simulation analysis and tests of laboratory showed that the aviation transport stretcher,and the strength and stiffness of its structure reached to requirement of CCAR-25 standard,which was suit to the portable aviation evacuation of severely injured patients on civil airliners,and the rapid transfer between air and ground.It has the function of supporting life,and the aviation transport stretcher with high universality and convenience can enhance the safety and rescue capability of aviation evacuation system of medical treatment of aviation.Conclusion:The portable aviation stretcher with high-versatility that was researched and developed by this study can effectively solve the problems of life support,injury monitoring,and emergently rescue and treatment during the transport for severely injured patients,which improve the support ability of air-ground transportation for severely injured patients.
5.Clinical effect of posterior lumbar interbody fusion under Delta large channel endoscope on degenerative lumbar diseases
Yunsheng CHEN ; Yaohong WU ; Canhua XU
Chinese Journal of Spine and Spinal Cord 2024;34(7):704-710
Objectives:To explore the curative effect of posterior lumbar interbody fusion under Delta large channel endoscope(Endo-PLIF)on degenerative lumbar diseases.Methods:A retrospective analysis was per-formed on the case data of 80 patients with degenerative lumbar diseases treated in the hospital between September 2021 and September 2022.The patients were divided into observation group(38 cases,17 males and 21 females,aged 61.0±4.9 years)and control group(42 cases,20 males and 22 females,aged 60.5±5.4 years).The patients in the observation group were treated with Endo-PLIF,while those in the control group were treated with open posterior lumbar interbody fusion.The intraoperative blood loss,postoperative drainage volume,operative time,length of surgical incisions,length of hospital stays,and complications of both groups of patients were recorded and compared.The visual analogue scale(VAS)was used to evaluate patients'low back pain and Oswestry disability index(ODI)was used to assess the lumbar function before surgery,at 1 week,1 month,3 months and 6 months after surgery.The patients were also evaluated using the modified Macnab criteria for treatment efficacy,and using the Bridwell criteria for assessing the segmental fusion within 1 year after surgery.Results:The intraoperative blood loss and postoperative drainage volume in the observation group were 88.46±10.98mL and 159.73±18.42mL,lower than those in the control group 112.99±12.01mL and 201.36±23.06mL(P<0.05);The lengths of surgical incision and hospital stays were 1.54±0.36cm and 6.79±1.22d,which were shorter in the observation group than those in the control group of 5.43±1.01cm and 8.03±1.43d(P<0.05);And the operative time was longer in the observation group than that in the control group(162.33±19.57min vs 126.87±23.15min,P<0.05).All the patients were followed up for 15-40 months(19.0±6.3 months).At 1 week and 1 month after surgery,VAS scores in observation group were 2.46±0.51 and 1.21±0.38,and ODI were(17.84±4.15)%and(10.69±1.88)%,which were lower than those in the control group[VAS score:3.68±0.62,2.01±0.41;ODI:(21.33±3.48)%,(12.33±2.17)%,P<0.05].At 3 months and 6 months after surgery,there was no significant difference in VAS scores between the two groups(P>0.05).There was neither significant difference in the excellent and good rate of treatment(92.11%vs 85.71%,P=0.487)nor significant difference in fusion grading between the observation group and control group(Z=0.487,P=0.624).No significant difference was noticed in the incidence of postoperative complications between observation group and control group(5.26%vs 9.52%,P=0.678).Conclusions:The curative effect of Endo-PLIF is satisfactory on degenerative lumbar diseases,which can reduce intraoperative blood loss,shorten surgical incision and hospitalization time,improve short-term pain and lumbar function faster,with good safety.
6.Oral squamous cell carcinomas: state of the field and emerging directions.
Yunhan TAN ; Zhihan WANG ; Mengtong XU ; Bowen LI ; Zhao HUANG ; Siyuan QIN ; Edouard C NICE ; Jing TANG ; Canhua HUANG
International Journal of Oral Science 2023;15(1):44-44
Oral squamous cell carcinoma (OSCC) develops on the mucosal epithelium of the oral cavity. It accounts for approximately 90% of oral malignancies and impairs appearance, pronunciation, swallowing, and flavor perception. In 2020, 377,713 OSCC cases were reported globally. According to the Global Cancer Observatory (GCO), the incidence of OSCC will rise by approximately 40% by 2040, accompanied by a growth in mortality. Persistent exposure to various risk factors, including tobacco, alcohol, betel quid (BQ), and human papillomavirus (HPV), will lead to the development of oral potentially malignant disorders (OPMDs), which are oral mucosal lesions with an increased risk of developing into OSCC. Complex and multifactorial, the oncogenesis process involves genetic alteration, epigenetic modification, and a dysregulated tumor microenvironment. Although various therapeutic interventions, such as chemotherapy, radiation, immunotherapy, and nanomedicine, have been proposed to prevent or treat OSCC and OPMDs, understanding the mechanism of malignancies will facilitate the identification of therapeutic and prognostic factors, thereby improving the efficacy of treatment for OSCC patients. This review summarizes the mechanisms involved in OSCC. Moreover, the current therapeutic interventions and prognostic methods for OSCC and OPMDs are discussed to facilitate comprehension and provide several prospective outlooks for the fields.
Humans
;
Carcinoma, Squamous Cell/therapy*
;
Squamous Cell Carcinoma of Head and Neck
;
Mouth Neoplasms/therapy*
;
Head and Neck Neoplasms
;
Tumor Microenvironment
7.A multifrequency time-difference electrical impedance tomography algorithm using spectral constraints.
Lu CAO ; Bin YANG ; Haoting LI ; Xuechao LIU ; Benyuan LIU ; Canhua XU ; Ruigang LIU ; Feng FU
Journal of Biomedical Engineering 2020;37(1):80-86
This study aims to propose a multifrequency time-difference algorithm using spectral constraints. Based on the knowledge of tissue spectrum in the imaging domain, the fraction model was used in conjunction with the finite element method (FEM) to approximate a conductivity distribution. Then a frequency independent parameter (volume or area fraction change) was reconstructed which made it possible to simultaneously employ multifrequency time-difference boundary voltage data and then reduce the degrees of freedom of the reconstruction problem. Furthermore, this will alleviate the illness of the EIT inverse problem and lead to a better reconstruction result. The numerical validation results suggested that the proposed time-difference fraction reconstruction algorithm behaved better than traditional damped least squares algorithm (DLS) especially in the noise suppression capability. Moreover, under the condition of low signal-to-noise ratio, the proposed algorithm had a more obvious advantage in reconstructions of targets shape and position. This algorithm provides an efficient way to simultaneously utilize multifrequency measurement data for time-difference EIT, and leads to a more accurate reconstruction result. It may show us a new direction for the development of time-difference EIT algorithms in the case that the tissue spectrums are known.
8.Efficacy comparison of three different treatment of internal fixation of intervetebral crasis on spinal cord cervical spondylosis
Canhua XU ; Zenghui WU ; Zhi ZHENG ; Qingshun ZHANG
Chongqing Medicine 2015;(31):4345-4348
Objective To observe the difference of efficacy of three different treatment of internal fixation of intervetebral crasis on cervical spondylosis (spinal cord) .Methods From January 2009 to January 2013 ,There are 167 cases of patients admitted to hospital from cervical spondylosis (spinal cord ) ,randomly selected different fusion fixation methods are divided into three groups :in the first group ,there were 55 patients treated with autologous iliac bone graft fusion plate fixation ;in the second group , there were 60 patients treated with zero profile material PEEK interbody fusion with autologous bone graft ;in the third group ,the 52 patients were treated with the PEEK material MC + self‐locking cervical interbody fusion with autologous bone graft .Observa‐tion and comparison indicators include :spinal cord function JOA scores before and after surgery ,surgical segment intervertebral height and cervical curvature condition .Results Follow‐up lasted from 13 to 50 months ,the average length was 26 months .The difference in operation time ,blood loss during surgery analysis ,wherein the first group and the second or third group of three groups was statistically significant (P<0 .05) ,the difference between the second group and the third group was not statistically significant (P>0 .05) .In the first group ,there were 17 patients had transient throat discomfort and symptom disappeared 48 hours later ;dysphagia relieved or disappeared in one week ;there were two cases of screws and titanium loosen one week after operation , and were treated with immediate revision surgery .In the second ,third group ,there were 19 cases and 13 cases showed temporary throat discomfort disappeared within 48 hours after surgery respectively ,there was no dysphagia .No patient experienced cerebrospi‐nal fluid leakage ,hematoma and wound infection .The postoperative JOA scores spinal cord function (17 points France) ,surgical segmental cervical intervertebral height and curvature of three groups improved significantly compared with preoperative evaluation index ,and there was no significant difference among three groups (P>0 .05) .In the last follow‐up ,the interbody fusion rates of the first ,second and third groups were 67 .1% ,66 .3% and 65 .9% ,the difference between groups was not statistically significant (P>0 .05) .Conclusion Anterior decompression and interbody fusion locking device applications showed good performance in maintai‐ning the intervertebral height segment surgery ,rehabilitation cervical curvature ,and promote bone fusion with autogenous titanium plate fixation comparison .Patients can get a good surgery ,and the former has a simpler surgical fixation method ,shorter time ,less bleeding and less complications .
9.The study on the job stressors of nurses employed in military hospitals and relationship between job stressors and demography characters
Xi XU ; Song ZHANG ; Canhua XIAO ; Meirong HU
Chinese Journal of Practical Nursing 2006;0(12):-
Objective This study was conducted to describe job stressors of nurses employed in military hospitals and relationship between job stressors and demography characters.Method 296 employed nurses were investigated by nurse job stressor questionnaires.Result Professional and career issues were the most frequently encountered job stressor among employed nurses,the other stressors in descending order were workload and time pressure,patient care and interaction,resource and environmental problems,management issues.Job stressors of nurses could be influenced by their age,job title,et al.Conclusion The finding suggest that effective stress management strategies should be relieve job stress.
10.Comparison of Performances of Ag/AgCl Coating Electrodes and Pulverized Electrodes in Cerebral Application of Electrical Impedance Tomography
Meng DAI ; Xiuzhen DONG ; Fusheng YOU ; Xuetao SHI ; Canhua XU
Chinese Medical Equipment Journal 2004;0(09):-
Objective To compare the performance of novel Ag/AgCl pulverized electrodes with conventional Ag/AgCl coating electrodes in cerebral application of Electrical Impedance Tomography(EIT).Methods Based on the EIT system developed by our group,raw data were measured on a phantom and an adult volunteer,with Ag/AgCl coating electrodes and pulverized electrodes,respectively.The performances of electrode systems were evaluated in contact impedance and two other figures(the high-frequency SNR,HFSNR;the low-frequency SNR,LFSNR).Results Ag/AgCl pulverized electrode plays a better performance in resisting noise and keeping stabilization.Conclusion Ag/AgCl pulverized electrode develops the needs of imaging and monitoring human brains in EIT more availably.

Result Analysis
Print
Save
E-mail