1.Meta-analysis of anterior cervical decompression and fusion ROI-CTM self-locking system in treatment of degenerative cervical spondylosis
Yanjie ZHOU ; Chunfeng CAO ; Zhongzu ZHANG ; Xiong NIU ; Xin WANG ; Zaihai YANG ; Liang ZHOU ; Bo LI
Chinese Journal of Tissue Engineering Research 2025;29(3):617-627
OBJECTIVE:Anterior cervical decompression and fusion is a classic surgical method for the treatment of degenerative cervical spondylosis.The use of nail plates increases the fusion rate and stability and indirectly leads to adjacent vertebral degeneration and postoperative dysphagia.In this paper,the clinical results and complications of ROI-CTM self-locking system and traditional cage combined with screw-plate internal fixation in the treatment of degenerative cervical spondylosis were compared by meta-analysis to provide evidence-based support for the selection of internal fixation methods in anterior cervical decompression and fusion. METHODS:CNKI,WanFang,VIP,PubMed,Cochrane Library,Web of Science,and Embase databases were searched for Chinese and English literature on the application of ROI-CTM self-locking system and fusion cage combined with screw plate internal fixation in the treatment of degenerative cervical spondylosis.The retrieval time range was from inception to July 2023.Two researchers selected the literature strictly according to the inclusion and exclusion criteria.The Cochrane bias risk tool was used to evaluate the quality of randomized controlled trials.Newcastle-Ottawa Scale was used to assess the quality of cohort studies.Meta-analysis was performed using RevMan 5.4 software.Outcome indicators included operation time,intraoperative blood loss,Japanese Orthopaedic Association score,Neck Disability Index,C2-C7 Cobb angle,fusion rate,incidence of adjacent vertebral degeneration,cage subsidence rate,and incidence of dysphagia. RESULTS:Thirteen articles were included,including eleven retrospective cohort studies and two randomized controlled trials,with 1 136 patients,569 in the ROI-C group,and 567 in the cage combined with the nail plate group.Meta-analysis results showed that the operation time(MD=-15.52,95%CI:-18.62 to-12.42,P<0.000 01)and intraoperative blood loss(MD=-24.53,95%CI:-32.46 to-16.61,P<0.000 01)in the ROI-C group and the fusion device combined with nail plate group.Postoperative adjacent segment degeneration rate(RR=0.40,95%CI:0.27-0.60,P<0.000 01)and postoperative total dysphagia rate(RR=0.18,95%CI:0.13-0.26),P<0.000 01)were statistically different.The two groups had no significant difference in Japanese Orthopaedic Association score,Neck Disability Index,C2-C7 Cobb angle,fusion rate,or cage subsidence rate(P≥0.05). CONCLUSION:Applying an ROI-CTM self-locking system and traditional cage combined with plate internal fixation in anterior cervical decompression and fusion can achieve satisfactory clinical results in treating degenerative cervical spondylosis.The operation of the ROI-CTM self-locking system is more straightforward.Compared with a cage combined with plate internal fixation,the ROI-CTM self-locking system can significantly reduce the operation time and intraoperative blood loss and has obvious advantages in reducing the incidence of postoperative dysphagia and adjacent segment degeneration.The ROI-CTM self-locking system is recommended for patients with skip cervical spondylosis and adjacent vertebral disease.However,given its possible high settlement rate,using a fusion cage combined with screw-plate internal fixation is still recommended for patients with degenerative cervical spondylosis with multiple segments and high-risk factors of fusion cage settlement,such as osteoporosis and vertebral endplate damage.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effects of donor gender on short-term survival of lung transplant recipients: a single-center retrospective cohort study
Xiaoshan LI ; Shiqiang XUE ; Min XIONG ; Rong GAO ; Ting QIAN ; Lin MAN ; Bo WU ; Jingyu CHEN
Organ Transplantation 2025;16(4):591-598
Objective To evaluate the effect of donor gender on short-term survival rate of lung transplant recipients. Methods A retrospective analysis was conducted on the data of 1 066 lung transplant recipients. The log-rank test was used to evaluate the differences in short-term fatality among different donor gender groups and donor-recipient gender combination groups. Multivariate Cox regression, propensity score (PS) regression, and propensity score matching (PSM) were employed to control for confounding factors and further assess the differences in fatality. Subgroup analyses were also performed based on donor gender. Results Multivariate Cox regression analysis showed no statistically significant differences in fatality at 30 days, 1 year, 2 years and 3 years postoperatively between male and female donor groups (all P>0.05). After PS regression and PSM, univariate Cox regression analysis indicated that recipients from female donors had a higher fatality at 2 years postoperatively compared to those from male donors, with hazard ratios (95% confidence intervals) of 1.29 (1.01-1.65) and 1.36 (1.03-1.80) respectively. Multivariate Cox regression analysis also revealed no statistically significant differences in fatality at various follow-up time points among different donor-recipient gender combination groups (all P>0.05). Subgroup analyses based on donor sex showed no statistically significant differences in fatality among recipients of different gender within either male or female donor groups (all P>0.05). Conclusions Female donors may reduce the short-term postoperative survival rate of lung transplant recipients, but this negative impact is not sustainable in the long term. At present, there is no evidence to support the inclusion of sex as a factor in lung allocation rules.
9.Study on the effect of postoperative implant fusion after anterior cervical discectomy and fusion by applying nano-hydroxyapatite/collagen composite in patients with low bone mass cervical spondylosis.
Shi-Bo ZHOU ; Xing YU ; Ning-Ning FENG ; Zi-Ye QIU ; Yu-Kun MA ; Yang XIONG
China Journal of Orthopaedics and Traumatology 2025;38(8):800-809
OBJECTIVE:
To explore the effect of nano-hydroxyapatite/collagen composite (nHAC) on bone graft fusion after anterior cervical discectomy and fusion (ACDF) in patients with cervical spondylosis and low bone mass.
METHODS:
A retrospective analysis was conducted on 47 patients with low bone mass who underwent ACDF from 2017 to 2021. They were divided into the nHAC group and the allogeneic bone group according to different bone graft materials. The nHAC group included 26 cases, with 8 males and 18 females;aged 50 to 78 years old with an average of (62.81±7.79) years old;the CT value of C2-C7 vertebrae was (264.16±36.33) HU. The allogeneic bone group included 21 cases, with 9 males and 12 females;aged 54 to 75 years old with an average of (65.95±6.58) years old;the CT value of C2-C7 vertebrae was (272.39±40.44) HU. The visual analogue scale (VAS), neck disability index (NDI), and Japanese Orthopaedic Association (JOA) spinal cord function score were compared before surgery, 1 week after surgery, and at the last follow-up to evaluate the clinical efficacy. Imaging assessment included C2-C7 Cobb angle, surgical segment height, intervertebral fusion, and whether the cage subsidence occurred at 1 week after surgery and the last follow-up.
RESULTS:
The follow-up duration ranged from 26 to 39 months with an average of (33.27±3.34) months in the nHAC group and 26 to 41 months with an average of (31.86±3.57) months in the allogeneic bone group. At 1 week after surgery and the last follow-up, the VAS, NDI scores, and JOA scores in both groups were significantly improved compared with those before surgery, with statistically significant differences (P<0.05). At 1 week after surgery, the C2-C7 Cobb angles in the nHAC group and the allogeneic bone group were (14.26±10.32)° and (14.28±8.20)° respectively, which were significantly different from those before surgery (P<0.05). At the last follow-up, the C2-C7 Cobb angles in both groups were smaller than those at 1 week after surgery, with statistically significant differences (P<0.05). At 1 week after surgery, the height of the surgical segment in the nHAC group was (31.65±2.55) mm, and that in the allogeneic bone group was (33.63±3.26) mm, which were significantly different from those before surgery (P<0.05). At the last follow-up, the height of the surgical segment in both groups decreased compared with that at 1 week after surgery, with statistically significant differences (P<0.05). At the last follow-up, 39 surgical segments were fused and 6 cages subsided in the nHAC group;40 surgical segments were fused and 7 cages subsided in the allogeneic bone group;there was no statistically significant difference between the two groups (P>0.05). Compared with the CT value of vertebrae without cage subsidence, the CT value of vertebrae with cage subsidence in both groups was significantly lower, with a statistically significant difference (P<0.05).
CONCLUSION
The application of nHAC in ACDF for patients with low bone mass can achieve effective fusion of the surgical segment. There is no significant difference in improving clinical efficacy, intervertebral fusion, and cage subsidence compared with the allogeneic bone group. With the extension of follow-up time, the C2-C7 Cobb angle decreases, the height of the surgical segment is lost, and the cage subsides in both the nHAC group and the allogeneic bone group, which may be related to low bone mass. Low bone mass may be one of the risk factors for cervical spine sequence changes, surgical segment height loss, and cage subsidence after ACDF.
Humans
;
Male
;
Female
;
Middle Aged
;
Spondylosis/physiopathology*
;
Spinal Fusion/methods*
;
Cervical Vertebrae/surgery*
;
Aged
;
Diskectomy
;
Durapatite
;
Retrospective Studies
;
Collagen/chemistry*
10.Effects of hyperoxia on the expression of hippocampal N-methyl D-aspartate receptor 1 and its synapse-associated molecules in neonatal rats.
Yi XIONG ; Lin CHENG ; Na JIANG ; Tuan-Mei WANG ; Tao BO
Chinese Journal of Contemporary Pediatrics 2025;27(8):1002-1010
OBJECTIVES:
To investigate the effects of hyperoxia on the expression of N-methyl-D-aspartate receptor 1 (NMDAR1) and its synapse-associated molecules, including cannabinoid receptor 1 (CB1R), postsynaptic density 95 (PSD95), and synapsin (SYN), in the hippocampus of neonatal rats.
METHODS:
One-day-old Sprague-Dawley neonatal rats were randomly divided into a hyperoxia group and a control group (n=8 per group). The hyperoxia group was exposed to 80% ± 5% oxygen continuously, while the control group was exposed to room air, for 7 days. At 1, 3, and 7 days after hyperoxia exposure, hematoxylin and eosin (HE) staining was used to observe histopathological changes in the brain. The expression levels of NMDAR1, CB1R, PSD95, and SYN proteins and mRNAs in the hippocampus were detected by immunohistochemistry, Western blotting, and quantitative real-time PCR.
RESULTS:
After 7 days of hyperoxia exposure, the hyperoxia group showed decreased neuronal density and disordered arrangement in brain tissue. Compared with the control group, after 1 day of hyperoxia exposure, CB1R mRNA and both NMDAR1 and CB1R protein expression in the hyperoxia group were significantly downregulated, while SYN protein expression was significantly upregulated (P<0.05). After 3 days, mRNA expression of NMDAR1, CB1R, and SYN was significantly decreased (P<0.05); NMDAR1 and CB1R protein expression was significantly downregulated (P<0.05), while PSD95 and SYN protein expression was significantly upregulated (P<0.05). After 7 days of hyperoxia, the protein expression of NMDAR1 and CB1R was significantly upregulated (P<0.05).
CONCLUSIONS
Continuous hyperoxia exposure induces time-dependent changes in the expression levels of NMDAR1 and its synapse-associated molecules in the hippocampus of neonatal rats.
Animals
;
Receptors, N-Methyl-D-Aspartate/genetics*
;
Rats, Sprague-Dawley
;
Hippocampus/pathology*
;
Rats
;
Animals, Newborn
;
Receptor, Cannabinoid, CB1/genetics*
;
Hyperoxia/metabolism*
;
Disks Large Homolog 4 Protein/genetics*
;
Synapsins/genetics*
;
Synapses
;
Male
;
Female
;
RNA, Messenger/analysis*

Result Analysis
Print
Save
E-mail