2.Maintenance of pegylated liposomal doxorubicin/carboplatin in patients with advanced ovarian cancer: randomized study of an Asian Gynecologic Oncology Group
Chyong Huey LAI ; Elizabeth VALLIKAD ; Hao LIN ; Lan Yan YANG ; Shih Ming JUNG ; Hsueh Erh LIU ; Yu Che OU ; Hung Hsueh CHOU ; Cheng Tao LIN ; Huei Jean HUANG ; Kuan Gen HUANG ; Jiantai QIU ; Yao Ching HUNG ; Tzu I WU ; Wei Yang CHANG ; Kien Thiam TAN ; Chiao Yun LIN ; Angel CHAO ; Chee Jen CHANG
Journal of Gynecologic Oncology 2020;31(1):5-
3.Diagnostic Accuracy of a Novel On-site Virtual Fractional Flow Reserve Parallel Computing System
Hyung Bok PARK ; Yeonggul JANG ; Reza ARSANJANI ; Minh Tuan NGUYEN ; Sang Eun LEE ; Byunghwan JEON ; Sunghee JUNG ; Youngtaek HONG ; Seongmin HA ; Sekeun KIM ; Sang Wook LEE ; Hyuk Jae CHANG
Yonsei Medical Journal 2020;61(2):137-144
bias of 0.005 (95% CI −0.011 to 0.021) with 95% limits of agreement of −0.16 to 0.17 between vFFR and FFR. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 78.0%, 87.1%, 72.5%, 58.7%, and 92.6%, respectively, using the FFR cutoff of 0.80. They were 87.0%, 95.0%, 80.0%, 54.3%, and 98.5%, respectively, with the FFR cutoff of 0.75. The area under the receiver-operating characteristics curve of vFFR versus obstructive CTA stenosis was 0.88 versus 0.61 for the FFR cutoff of 0.80, respectively; it was 0.94 versus 0.62 for the FFR cutoff of 0.75.CONCLUSION: Our novel, fully automated, on-site vFFR technology showed excellent diagnostic performance for the detection of lesion-specific ischemia.]]>
Angiography
;
Bias (Epidemiology)
;
Constriction, Pathologic
;
Coronary Angiography
;
Fractional Flow Reserve, Myocardial
;
Humans
;
Ischemia
;
Patient-Specific Modeling
;
Sensitivity and Specificity
4.Incidence of Hypotension after Discontinuation of Norepinephrine or Arginine Vasopressin in Patients with Septic Shock: a Systematic Review and Meta-Analysis
Jae Uk SONG ; Jonghoo LEE ; Hye Kyeong PARK ; Gee Young SUH ; Kyeongman JEON
Journal of Korean Medical Science 2020;35(1):8-
bias. In addition, there were no significant differences in intensive care unit (ICU) mortality, in-hospital mortality, 28-day mortality, or ICU length of stay between the groups.CONCLUSION: Discontinuing NE prior to AVP was associated with a lower incidence of hypotension in patients recovering from septic shock. However, our results should be interpreted with caution, due to the considerable between-study heterogeneity.]]>
Arginine Vasopressin
;
Arginine
;
Bias (Epidemiology)
;
Consensus
;
Hospital Mortality
;
Humans
;
Hypotension
;
Incidence
;
Intensive Care Units
;
Length of Stay
;
Mortality
;
Norepinephrine
;
Odds Ratio
;
Population Characteristics
;
Sepsis
;
Shock, Septic
;
Treatment Outcome
;
Vasoconstrictor Agents
5.Precision Medicine and Cardiovascular Health: Insights from Mendelian Randomization Analyses
Wes SPILLER ; Keum Ji JUNG ; Ji Young LEE ; Sun Ha JEE
Korean Circulation Journal 2020;50(2):91-111
Cardiovascular disease (CVD) is considered a primary driver of global mortality and is estimated to be responsible for approximately 17.9 million deaths annually. Consequently, a substantial body of research related to CVD has developed, with an emphasis on identifying strategies for the prevention and effective treatment of CVD. In this review, we critically examine the existing CVD literature, and specifically highlight the contribution of Mendelian randomization analyses in CVD research. Throughout this review, we assess the extent to which research findings agree across a range of studies of differing design within a triangulation framework. If differing study designs are subject to non-overlapping sources of bias, consistent findings limit the extent to which results are merely an artefact of study design. Consequently, broad agreement across differing studies can be viewed as providing more robust causal evidence in contrast to limiting the scope of the review to a single specific study design. Utilising the triangulation approach, we highlight emerging patterns in research findings, and explore the potential of identified risk factors as targets for precision medicine and novel interventions.
Artifacts
;
Bias (Epidemiology)
;
Cardiovascular Diseases
;
Mendelian Randomization Analysis
;
Mortality
;
Precision Medicine
;
Random Allocation
;
Risk Factors
6.Impact of Repetitive Transcranial Magnetic Stimulation with Computerized Cognitive Enhancement Training on Change in Cognitive Function of Mild Cognitive Impairment Patients : Existing, Sham Treatment Controlled, Pilot Study
Si Eun LEE ; Ho Sang MOON ; Sung Taek CHUNG ; Chang Uk LEE ; Dong Woo KANG
Journal of Korean Geriatric Psychiatry 2019;23(2):51-57
bias factor of this study and further studies supplementing these factors are needed.]]>
Bias (Epidemiology)
;
Cognition
;
Humans
;
Mild Cognitive Impairment
;
Neuropsychological Tests
;
Pilot Projects
;
Placebos
;
Prefrontal Cortex
;
Sample Size
;
Transcranial Magnetic Stimulation
;
Treatment Outcome
7.Benefit of Early Statin Initiation within 48 Hours after Admission in Statin-Naïve Patients with Acute Myocardial Infarction Undergoing Percutaneous Coronary Intervention
Min Chul KIM ; Youngkeun AHN ; Jae Yeong CHO ; Ki Hong LEE ; Doo Sun SIM ; Nam Sik YOON ; Hyun Ju YOON ; Kye Hun KIM ; Young Joon HONG ; Hyung Wook PARK ; Ju Han KIM ; Myung Ho JEONG ; Jeong Gwan CHO ; Jong Chun PARK ; Kiyuk CHANG ; Ki Bae SEUNG
Korean Circulation Journal 2019;49(5):419-433
BACKGROUND AND OBJECTIVES: Although current guidelines recommend early initiation of statin in patients with acute myocardial infarction (AMI), there is no consensus for optimal timing of statin initiation. METHODS: A total of 3,921 statin-naïve patients undergoing percutaneous coronary intervention were analyzed, and divided into 3 groups according to statin initiation time: group 1 (statin initiation <24 hours after admission), group 2 (24–48 hours) and group 3 (≥48 hours). We also made 3 stratified models to reduce bias: model 1 (<24 hours vs. ≥24 hours), model 2 (<48 hours vs. ≥48 hours) and model 3 (<24 hours vs. 24–48 hours). The endpoint was major adverse cardiac events (MACE; composite of cardiac death, myocardial infarction and target-vessel revascularization) during median 3.8 years. RESULTS: During follow-up, incidence of MACE was lower in early statin group in both model 1 (14.3% vs. 18.4%, hazard ratio [HR], 0.77; 95% confidence interval [CI], 0.66–0.91; p=0.002) and model 2 (14.6% vs. 19.7%, HR, 0.81; 95% CI, 0.67–0.97; p=0.022). After propensity-score matching, results remained unaltered. Statin initiation <24 hours reduced MACE compared to statin initiation ≥24 hours in model 1. Statin initiation <48 hours also reduced MACE compared to statin initiation later in model 2. However, there was no difference in incidence of MACE between statin initiation <24 hours and 24–48 hours) in model 3. CONCLUSIONS: Early statin therapy within 48 hours after admission in statin-naïve patients with AMI reduced long-term clinical outcomes compared with statin initiation later. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02385682
Bias (Epidemiology)
;
Consensus
;
Death
;
Follow-Up Studies
;
Humans
;
Hydroxymethylglutaryl-CoA Reductase Inhibitors
;
Incidence
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
8.The Current State and Quality Assessment of Nursing Intervention Study in Occupational Health Nursing of Korea
Korean Journal of Occupational Health Nursing 2019;28(1):21-35
PURPOSE: The purpose of this study is to propose directions for the development of Occupational Health Nursing Intervention by identifying the current status and quality of Occupational Health Nursing Intervention Research in domestic industries. METHODS: Between 2000 and August of 2018, total of 1,181 Occupational Health Nursing related published references were searched using 4 domestic databases, and of the total, 29 final theses that suited the requirements were analysed In this research, the quality assessment of literature that were selected as suitable was conducted using a tool for assessing the biasing risk of non-randomized studies, RoBANS(Risk of Biasing Assessment Tool for Non-randomized Study). RESULTS: For all research, nonequivalent control group pre-posttest design was the most used as quasi-experimental designs. The effectiveness of intervention was found both in terms of physical and psychological aspects, and the result of the risk of biasing assessment showed a high risk levels in both “confounding variables” and “detection bias”. CONCLUSION: Occupational Health Nursing Intervention have been steadily making improvements in terms of both quality and quantity, and as for more effective intervention developments that improves the physical and mental health of the workers, supplementation in strict research design and in ethical aspects deems necessary.
Bias (Epidemiology)
;
Korea
;
Mental Health
;
Nursing
;
Occupational Health Nursing
;
Occupational Health
;
Research Design
9.Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement
Songlin YU ; Weiyan ZHOU ; Xinqi CHENG ; Qinghui MENG ; Honglei LI ; Li'an HOU ; Jun LU ; Shaowei XIE ; Qian CHENG ; Chuanbao ZHANG ; Ling QIU
Annals of Laboratory Medicine 2019;39(4):381-387
BACKGROUND: Accurate serum total thyroxine (TT4) measurement is important for thyroid disorder diagnosis and management. We compared the performance of six automated immunoassays with that of isotope-diluted liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) as the reference method. We also evaluated the correlation of thyroid stimulating hormone (TSH) with TT4 measured by ID-LC-MS/MS and immunoassays. METHODS: Serum was collected from 156 patients between October 2015 and January 2016. TT4 was measured by immunoassays from Abbott (Architect), Siemens (ADVIA Centaur XP), Roche (E601), Beckman-Coulter (Dxi800), Autobio (Autolumo A2000), and Mindray (CL-1000i), and by ID-LC-MS/MS. Results were analyzed using Passing-Bablok regression and Bland-Altman plots. Minimum requirements based on biological variation were as follows: a mean bias of ≤4.5% and total imprecision (CV) of ≤3.7%. RESULTS: All immunoassays showed a correlation >0.945 with ID-LC-MS/MS; however, the slope of the Passing-Bablok regression line varied from 0.886 (Mindray) to 1.23 (Siemens) and the intercept from −12.8 (Siemens) to 4.61 (Mindray). Only Autobio, Beckman-Coulter, and Roche included the value of one in the 95% confidence interval for slope. The mean bias ranged from −10.8% (Abbott) to 9.0% (Siemens), with the lowest value noted for Roche (3.5%) and the highest for Abbott (−10.8%). Only Abbott and Roche showed within-run and total CV ≤3.7%. CONCLUSIONS: Though all immunoassays correlated strongly with ID-LC-MS/MS, most did not meet the minimum clinical requirement. Laboratories and immunoassay manufacturers must be aware of these limitations.
Bias (Epidemiology)
;
Diagnosis
;
Humans
;
Immunoassay
;
Mass Spectrometry
;
Methods
;
Thyroid Gland
;
Thyrotropin
;
Thyroxine
10.Effects of Smartphone-Based Mobile Learning in Nursing Education: A Systematic Review and Meta-analysis
Asian Nursing Research 2019;13(1):20-29
PURPOSE: A systematic review and meta-analysis was conducted to evaluate the effects of smartphone-based mobile learning for nurses and nursing students. METHODS: Electronic literature search of PubMed, Cochrane Library, Embase, SCOPUS, Web of Science, ProQuest Central, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Educational Resource Information Center (ERIC) was conducted. Two authors independently reviewed empirical studies for inclusion and extracted the design, sample size, intervention method, outcome variables, and statistical values of them. Methodological quality was assessed using Cochrane collaboration risk of bias tool. To estimate the effect size, meta-analysis was performed using R meta program. RESULTS: Authors identified 11 randomized or nonrandomized controlled trials of a total of 3,419 studies. Overall effect sizes by random-effects model was large [Hedges'g (g) = 1.12, 95% confidence interval (CI) 0.72−1.52], with learning attitude (g = 1.69), skills (g = 1.41), knowledge (g = 1.47), and confidence in performance (g = 1.54). For heterogeneity, subgroup analyses using meta-analysis of variance were performed, but no significant difference was found. Finally, a funnel plot and Egger's regression test along with trim-and-fill analysis and fail-safe N were conducted to check for publication bias, but no significant bias was detected. CONCLUSION: Smartphone-based mobile learning had significantly positive influence on nursing students' knowledge, skills, confidence in performance, and learning attitude. Smartphone-based mobile learning may be an alternative or supportive method for better education in nursing fields.
Bias (Epidemiology)
;
Cooperative Behavior
;
Education
;
Education, Nursing
;
Humans
;
Information Centers
;
Learning
;
Methods
;
Nursing
;
Population Characteristics
;
Publication Bias
;
Sample Size
;
Smartphone
;
Students, Nursing

Result Analysis
Print
Save
E-mail