1.Relationship Between Gastroesophageal Reflux Disease-Related Symptoms and Clinicopathologic Characteristics and Long-Term Survival of Patients with Esophageal Adenocarcinoma in China
Kan ZHONG ; Xin SONG ; Ran WANG ; Mengxia WEI ; Xueke ZHAO ; Lei MA ; Quanxiao XU ; Jianwei KU ; Lingling LEI ; Wenli HAN ; Ruihua XU ; Jin HUANG ; Zongmin FAN ; Xuena HAN ; Wei GUO ; Xianzeng WANG ; Fuqiang QIN ; Aili LI ; Hong LUO ; Bei LI ; Lidong WANG
Cancer Research on Prevention and Treatment 2025;52(8):661-665
Objective To investigatethe relationship between gastroesophageal reflux disease (GERD) symptoms and clinicopathological characteristics, p53 expression, and survival of Chinese patients with esophageal adenocarcinoma. Methods A total of
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Discovery of a novel AhR-CYP1A1 axis activator for mitigating inflammatory diseases using an in situ functional imaging assay.
Feng ZHANG ; Bei ZHAO ; Yufan FAN ; Lanhui QIN ; Jinhui SHI ; Lin CHEN ; Leizhi XU ; Xudong JIN ; Mengru SUN ; Hongping DENG ; Hairong ZENG ; Zhangping XIAO ; Xin YANG ; Guangbo GE
Acta Pharmaceutica Sinica B 2025;15(1):508-525
The aryl hydrocarbon receptor (AhR) plays a crucial role in regulating many physiological processes. Activating the AhR-CYP1A1 axis has emerged as a novel therapeutic strategy against various inflammatory diseases. Here, a practical in situ cell-based fluorometric assay was constructed to screen AhR-CYP1A1 axis modulators, via functional sensing of CYP1A1 activities in live cells. Firstly, a cell-permeable, isoform-specific enzyme-activable fluorogenic substrate for CYP1A1 was rationally constructed for in-situ visualizing the dynamic changes of CYP1A1 function in living systems, which was subsequently used for discovering the efficacious modulators of the AhR-CYP1A1 axis. Following screening of a compound library, LAC-7 was identified as an efficacious activator of the AhR-CYP1A1 axis, which dose-dependently up-regulated the expression levels of both CYP1A1 and AhR in multiple cell lines. LAC-7 also suppressed macrophage M1 polarization and reduced the levels of inflammatory factors in LPS-induced bone marrow-derived macrophages. Animal tests showed that LAC-7 could significantly mitigate DSS-induced ulcerative colitis and LPS-induced acute lung injury in mice, and markedly reduced the levels of multiple inflammatory factors. Collectively, an optimized fluorometric cell-based assay was devised for in situ functional imaging of CYP1A1 activities in living systems, which strongly facilitated the discovery of efficacious modulators of the AhR-CYP1A1 axis as novel anti-inflammatory agents.
8.Detection of germline variants in pancreatic cancer by next-generation sequencing and correlation analysis of clinical factors
Hui-Qin JIANG ; Li ZHANG ; Fei HUANG ; Xin-Ning CHEN ; Li YU ; Min-Na SHEN ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(1):19-24
Objective To investigate the rate of germline variants in patients with pancreatic cancer and clinical characteristics related with germline variants.Methods A total of 271 patients diagnosed with pancreatic cancer were enrolled in this study.Germline variants of 21 tumor susceptibility genes were detected by next-generation sequencing,and the relationship between germline variants and clinical factors such as age of onset,family history and personal history was analyzed.Results The rate of germline P/LP variants was 6.3%in unselected pancreatic cancer patients,but was high as 17.1%in genetic high-risk group patients(those with a family or personal history of cancer,or early-onset).Genes with higher frequency of germline variants in pancreatic cancer patients were PALB2,BRCA2,and ATM.Conclusion The rate of germline variants in overall pancreatic cancer patients is not high,but it increases significantly in genetic high-risk group,proving the importance of clinical factors in the screening of hereditary pancreatic cancer.
9.Identification and clearance of high-level drug-resistant Salmonella Kentucky ST198.2-1 from an occupational health examinee
Yan ZHONG ; Jingfang RUAN ; Xiachan QIN ; Bei WEI ; Yue LIU ; Min ZHOU ; Xuebin XU
Chinese Journal of Laboratory Medicine 2024;47(9):1094-1097
A 49-year-old female examinee, employed at a paper company in Guigang, Guangxi (engaged in the production of napkins), visited the Qintang District People′s Hospital in Guigang on June 11, 2023, to apply for a health certificate. Salmonella was isolated during a physical examination screening for enteric pathogens ( Salmonella, Shigella), and repeated use of empirical antibacterial drugs failed to eradicate the pathogen. A reference laboratory identified the two isolates as S. Kentucky ST198 by performing serotyping, drug resistance phenotyping, and whole genome sequencing. Based on the regional serotype database of Salmonella in China, a phylogenetic tree of S. Kentucky ST198 resistance genotypes was constructed, defining both isolated strains as high-level drug-resistant ST198.2-1 subclade clones. Following a multidisciplinary consultation and based on antimicrobial susceptibility test results, the treatment was adjusted to amoxicillin/clavulanate and azithromycin. On August 19, three consecutive negative test results confirmed the eradication of Salmonella Kentucky.
10.Campylobacter fetus subsp. fetus ST20 isolated and identified from the bacteremia patient
Bei WEI ; Fen GAO ; Yue LIU ; Yan ZHONG ; Yanfang LI ; Deju QIN ; Jincheng ZHOU ; Xuebin XU
Chinese Journal of Laboratory Medicine 2024;47(9):1102-1105
A 72-year-old female patient was admitted to the emergency department of Qintang District People′s Hospital of Guigang City in August 2023 due to chills and fever, abdominal distension and pain, diarrhea, cough and shortness of breath for 1 day. She had a history of chronic obstructive and pulmonary heart disease, stage Ⅲ hypertension, and ceftazidime allergy. Clinical diagnosis of acute bacterial infection of chronic obstructive pneumonia was made and levofloxacin combined with piperacillin/tazobactam were given as symptomatic treatment. The blood culture reported Campylobacter fetus after four days, and the patient was cured and discharged after seven days with negative blood culture. The morphology and mass spectrometry identification of the strain were consistent with the definition of Campylobacter fetus. Whole genome sequencing predicted the multi-site sequence type as Campylobacter fetus subsp. fetus( Cff) ST20, carrying the tetracycline resistance gene tet (O/M/O), 18 flagella genes (including rpoN gene from Campylobacter jejuni. these genes were not found in the other two Campylobacter fetus subspecies), and six virulence genes (including like-typhoidal toxin and typhoid toxin genes). The pathogen has the ecological characteristics of parasitic farmed animal colonization and the biological characteristics of high mobility and virulence. These attributes facilitated its entry into the bloodstream via the fecal-oral route, leading to invasive infections.

Result Analysis
Print
Save
E-mail