1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Relationship Between Gastroesophageal Reflux Disease-Related Symptoms and Clinicopathologic Characteristics and Long-Term Survival of Patients with Esophageal Adenocarcinoma in China
Kan ZHONG ; Xin SONG ; Ran WANG ; Mengxia WEI ; Xueke ZHAO ; Lei MA ; Quanxiao XU ; Jianwei KU ; Lingling LEI ; Wenli HAN ; Ruihua XU ; Jin HUANG ; Zongmin FAN ; Xuena HAN ; Wei GUO ; Xianzeng WANG ; Fuqiang QIN ; Aili LI ; Hong LUO ; Bei LI ; Lidong WANG
Cancer Research on Prevention and Treatment 2025;52(8):661-665
Objective To investigatethe relationship between gastroesophageal reflux disease (GERD) symptoms and clinicopathological characteristics, p53 expression, and survival of Chinese patients with esophageal adenocarcinoma. Methods A total of
7.Post-Orgasmic Illness Syndrome: Two Cases Treated with Autologous Seminal Plasma Subcutaneous Cluster Immunotherapy
Lun LI ; Yanping DUAN ; Fan ZHI ; Jing ZHANG ; Yu LI ; Bei LIU ; Jia YIN
JOURNAL OF RARE DISEASES 2025;4(3):341-347
Post-orgasmic illness syndrome (POIS) is a rare condition characterized by the rapid onset of extreme fatigue, flu-like symptoms, difficulty concentrating, depression, nasal congestion, rhinorrhea, itchy eyes, and other physical and psychological discomforts following ejaculation. This report presents the outcomes of two patients with POIS who underwent a two-year course of autologous seminal plasma subcutaneous cluster immunotherapy. Treatment efficacy was assessed using methods such as the symptom Visual Analogue Scale (VAS), the Union Physio-Psycho-Social Assessment Questionnaire (UPPSAQ)-70, and the Short Form 36 Health Survey (SF-36). The results suggest that autologous seminal plasma subcutaneous cluster immunother-apy may be a safe and effective therapeutic approach for POIS.
8.Discovery of a novel AhR-CYP1A1 axis activator for mitigating inflammatory diseases using an in situ functional imaging assay.
Feng ZHANG ; Bei ZHAO ; Yufan FAN ; Lanhui QIN ; Jinhui SHI ; Lin CHEN ; Leizhi XU ; Xudong JIN ; Mengru SUN ; Hongping DENG ; Hairong ZENG ; Zhangping XIAO ; Xin YANG ; Guangbo GE
Acta Pharmaceutica Sinica B 2025;15(1):508-525
The aryl hydrocarbon receptor (AhR) plays a crucial role in regulating many physiological processes. Activating the AhR-CYP1A1 axis has emerged as a novel therapeutic strategy against various inflammatory diseases. Here, a practical in situ cell-based fluorometric assay was constructed to screen AhR-CYP1A1 axis modulators, via functional sensing of CYP1A1 activities in live cells. Firstly, a cell-permeable, isoform-specific enzyme-activable fluorogenic substrate for CYP1A1 was rationally constructed for in-situ visualizing the dynamic changes of CYP1A1 function in living systems, which was subsequently used for discovering the efficacious modulators of the AhR-CYP1A1 axis. Following screening of a compound library, LAC-7 was identified as an efficacious activator of the AhR-CYP1A1 axis, which dose-dependently up-regulated the expression levels of both CYP1A1 and AhR in multiple cell lines. LAC-7 also suppressed macrophage M1 polarization and reduced the levels of inflammatory factors in LPS-induced bone marrow-derived macrophages. Animal tests showed that LAC-7 could significantly mitigate DSS-induced ulcerative colitis and LPS-induced acute lung injury in mice, and markedly reduced the levels of multiple inflammatory factors. Collectively, an optimized fluorometric cell-based assay was devised for in situ functional imaging of CYP1A1 activities in living systems, which strongly facilitated the discovery of efficacious modulators of the AhR-CYP1A1 axis as novel anti-inflammatory agents.
9.Diagnostic value of musculoskeletal ultrasound in patients with limb pain
Zhengxi LONG ; Bei FU ; Qi FAN ; Yan SONG ; Lihua LUO ; Tingting LIU ; Huiling QI ; Sujiang CHEN
China Modern Doctor 2024;62(13):8-10
Objective To explore the diagnostic value of musculoskeletal ultrasound in patients with limb pain.Methods A total of 80 patients with limb pain admitted to the First Hospital of Nanchang from January 2021 to December 2022 were included in the study.All patients received magnetic resonance imaging(MRI)and musculoskeletal ultrasound on admission.The consistency and coincidence rate of musculoskeletal ultrasound and MRI in diagnosing the cause of limb pain were compared.Results In the 80 patients,MRI and musculoskeletal ultrasound detected positive results in 78 cases,accounting for 97.50%,and 2 cases had no clear disease type.According to the results of MRI,there were 75 cases in which musculoskeletal ultrasound diagnosis of the cause of limb pain was consistent with the MRI results,and total coincidence rate was 96.15%(75/78),with excellent consistency(Kappa=0.907).Conclusion Musculoskeletal ultrasound can clearly display the fine tissue structure,and the diagnosis accuracy of limb pain is high,and the diagnosis consistency with MRI is excellent.
10.Exploring the mechanism of action of sour jujube nut compound formula for depression based on network pharmacology and experimental validation
Hanwen ZHENG ; Xinyue LIU ; Haiyan ZHAO ; Jiayin WANG ; Fulong LUO ; Bei FAN ; Alberto Carlos Pires Dias ; Fengzhong WANG ; Qiong WANG
Acta Laboratorium Animalis Scientia Sinica 2024;32(7):901-912
Objective In this study,we aimed to use network pharmacology techniques to predict the key targets of a prescription of Ziziphi spinosae semen formula(ZSSF)compound for depression,and to verify its mechanism of action using a zebrafish model of rifampicin-induced depression.Methods The drug targets of ZSSF were retrieved from the TCMSP database,and the target names were corrected using the UniProt database.Depression-related targets were identified using the GeneCards,OMIM,and NCBI databases.Protein-protein interaction information for the shared targets was predicted using the STRING database.The collected data were then analyzed using the Metascape database to determine GO and KEGG pathway enrichment,and the result were visualized using microbiotics.Behavioral experiments and reverse-transcription quantitative PCR experiments were conducted to verify the therapeutic effects of ZSSF on a zebrafish depression model induced by risperdal.Results 188 targets were screened to find the interactions between depression and ZSSF.The protein-protein interaction result showed that ZSSF primarily targeted TNF-α,IL-2,IL-6,IL-1β,and IL-10 to produce its antidepressant effect.KEGG pathway enrichment analysis revealed that ZSSF exerted its effects on depression through various signaling pathways,including the TNF,PI3K-Akt,and cGMP-PKG signaling pathways.The result of the animal experiments showed that the treatment groups given high,medium,and low doses of ZSSF exhibited significant improvements in movement distance under acoustic and light stimulation compared with the model group(P<0.05).The speed of movement of the treatment groups was also significantly faster(P<0.01).Additionally,the mRNA expression levels of TNF-α,IL-2,IL-6,IL-1β,and IL-10 were up-regulated in the brain tissues of zebrafish in the high-,medium-,and low-dosage groups of ZSSF compared those in the model group(P<0.001).Conclusions ZSSF exerts its antidepressant effect through multiple components and targets,and its antidepressant effects may be associated with its inhibition of inflammatory factors.

Result Analysis
Print
Save
E-mail