1.Relationship between anthropometric parameters and 20 meter shuttle run test among children and adolescents
Chinese Journal of School Health 2023;44(11):1708-1712
Objective:
To determine the association between anthropometric parameters and 20 meter shuttle run test (20 m SRT) score among children and adolescents.
Methods:
The convenient sampling method was conducted to select 3 192 primary and secondary school students in Baoan District, Shenzhen, based on the street school types school from April to May 2019. Height, weight, 20 m SRT score and general demographic indicators were assessed and collected. Individuals were divided into two groups based on the dose response correlation between different anthropometric parameters (the Z score of height, weight and BMI) and 20 m SRT score analyzed with the restricted cubic spline. The association between the Z score of height and 20 m SRT score was further analyzed using the Spearman correlation analysis. Logistic regression analysis was used to analyze separately the relationship different anthropometric parameters and 20 m SRT score.
Results:
The Z value of weight and 20 m SRT score showed a non linear dose response association ( P <0.01), the significant but weak linear correlation between the Z value of height and 20 m SRT score ( r=0.06, P <0.05). The prevalence rate on the low level of the Z value of 20 m SRT score in 3 192 children and adolescents was 44.7%, and the gender ( χ 2=14.02, P <0.01) and grade difference ( χ 2=93.28, P <0.01) were both statistically significant. There was no significant relationship between the Z value of height and 20 m SRT score grade among total population, different genders and different grades ( P > 0.05). Compared with the reference group on the Z value of weight ≤-0.23, individuals with the Z value of weight >-0.23 had the low level of 20 m SRT score ( OR =0.61, P <0.05). Compared with the reference group on the Z value of BMI ≤ 0.25, individuals with the Z value of weight >0.25 had the low level of 20 m SRT score ( OR =0.45, P <0.05). Stratified for gender and grade, the above significant relationship on the Z value of weight, Z value of BMI and 20 m SRT score were still observed ( P <0.01).
Conclusions
The higher height Z value shows on correlations with 20 m SRT score, but the positive association is found between weight and BMI Z value and the 20 m SRT score. The cardiopulmonary fitness improvement may be more effective among children and adolescents when tuking weight and BMI Z scores into consideration.
2.Highly sensitive electrochemical determination of rutin based on the synergistic effect of 3D porous carbon and cobalt tungstate nanosheets
Feng GUANGJUN ; Yang YANG ; Zeng JIANTAO ; Zhu JUN ; Liu JINGJIAN ; Wu LUN ; Yang ZHIMING ; Yang GUANYI ; Mei QUANXI ; Chen QINHUA ; Ran FENGYING
Journal of Pharmaceutical Analysis 2022;12(3):453-459
Rutin,a flavonoid found in fruits and vegetables,is a potential anticancer compound with strong anti-cancer activity.Therefore,electrochemical sensor was developed for the detection of rutin.In this study,CoWO4 nanosheets were synthesized via a hydrothermal method,and porous carbon(PC)was prepared via high-temperature pyrolysis.Successful preparation of the materials was confirmed,and character-ization was performed by transmission electron microscopy,scanning electron microscopy,and X-ray photoelectron spectroscopy.A mixture of PC and CoWO4 nanosheets was used as an electrode modifier to fabricate the electrochemical sensor for the electrochemical determination of rutin.The 3D CoWO4 nanosheets exhibited high electrocatalytic activity and good stability.PC has a high surface-to-volume ratio and superior conductivity.Moreover,the hydrophobicity of PC allows large amounts of rutin to be adsorbed,thereby increasing the concentration of rutin at the electrode surface.Owing to the syn-ergistic effect of the 3D CoWO4 nanosheets and PC,the developed electrochemical sensor was employed to quantitively determine rutin with high stability and sensitivity.The sensor showed a good linear range(5-5000 ng/mL)with a detection limit of O.45 ng/mL.The developed sensor was successfully applied to the determination of rutin in crushed tablets and human serum samples.
3.Three-column scoring system for postoperative X-ray stability of intertrochanteric fracture after intramedullary nailing
Baoan PEI ; Shanshan DUAN ; Qingyun JIA ; Jinhua ZI ; Lisheng WU ; Yunzhen CHEN
Chinese Journal of Orthopaedic Trauma 2021;23(3):221-227
Objective:To evaluate the clinical significance of our self-designed three-column scoring system for postoperative X-ray stability of intertrochanteric fracture after intramedullary nailing.Methods:A retrospective study was conducted of the 378 patients with intertrochanteric fracture who had been treated between January 2015 and June 2019 at Department of Orthopaedics, Linyi People's Hospital by internal fixation with proximal femoral nail antirotation (PFNA). They were 161 males and 217 females, aged from 60 to 97 years (average, 72.5 years). By the AO classification, there were 109 cases of type 31-A1, 188 cases of type 31-A2 and 81 cases of type 31-A3. Anteroposterior and lateral X-ray examinations of the hip were performed immediately after internal fixation to evaluate the fracture stability using our self-designed three-column scoring system by which the medial column is given 4 points, middle column 2 points and lateral column 2 points. A single column scoring full points is rated as stable, 3-column stability as excellent, 2-column stability as good, one-column stability as fair, and 3-column unstability as poor. Rehabilitation programs were carried out according to the results of stability evaluation: full weight bearing at an early stage was indicated for excellent patients, partial weight bearing at an early stage for good patients and weight bearing at an early stage contraindicated for fair or poor patients. Fracture union time and failure of internal fixation were recorded. The relationship between internal fixation failure and our three-column scoring system was calculated.Results:The 378 patients were followed up for 6 to 24 months (mean, 10.4 months). Of them, 365 obtained fracture union after an average time of 4.3 months (from 3 to 7 months). Internal fixation failure occurred in 13 patients, giving a failure rate of 3.4%(13/378).Of the 129 excellent patients by our three-column scoring system for post-operative X-ray stability of intertrochanteric fracture, none failed in internal fixation; of the 193 good patients, 4 failed; of the 56 fair patients, 9 failed. Internal fixation failure was closely related to our three-column scoring system for postoperative X-ray stability of intertrochanteric fracture ( r=-0.986, P=0.006), as well as to the column stability ( r=-1.000, P=0.033). Conclusion:Our self-designed three-column scoring system for postoperative X-ray stability of intertrochanteric fracture after intramedullary nailing can accurately reflect the fracture stability so that it can be used to guide rehabilitation programs for the patients and judge their prognosis.
4.Sequential transcatheter arterial chemoembolization and selective portal vein embolization before major hepatectomy for large hepatocellular carcinoma: a pilot study
Wenchao ZHAO ; Yintao WU ; Yingxiang YANG ; Yang AN ; Nianxin XIA ; Peng LIU ; Jianyong ZHU ; Che LIU ; Hong ZHANG ; Jingbo LI ; Baoan QIU
Chinese Journal of Hepatobiliary Surgery 2021;27(3):164-168
Objective:To preliminarily study the feasibility, safety and efficacy of transcatheter arterial chemoembolization (TACE) combined with selective portal vein embolization (SPVE) before surgical resection in the treatment of large liver cancer.Methods:A retrospective study was conducted on the clinical data of 17 patients with large liver cancer treated with TACE combined with SPVE from January 2016 to December 2019 at the Department of Hepatobiliary Surgery, the Sixth Medical Center of PLA General Hospital. The study included 15 males and 2 females, aged (59.17±10.30) years. The levels of alanine aminotransferase, tumor changes and patient survival were analyzed before operation, after TACE, and after SPVE.Results:Among the 17 patients, the levels of alanine aminotransferase on the 1st and 3rd day after SPVE was significantly higher than those after TACE [191.4 (30.5-1966.4) IU/L vs 125.3 (35.7-846.2) IU/L on the first day, and 298.5 (24.6-1334.2) IU/L vs 208.6 (21.6-775.6) IU/L on the 3rd day], all P<0.05. One month after the two combined embolism, among the 6 patients with a tumor diameter of 5-10 cm, 2 patients (33.3%) had complete remission, 3 patients (50.0%) had partial remission, and 1 patients (16.6%) had stable disease. For the tumor’s longest diameter, among the 11 patients with tumors >10 cm, 1 patient had complete remission (9.1%), 4 patients had partial remission (36.4%), 5 patients had stable diseases (45.5%), and 1 patient had disease progression (9.1%). Eventually, 11 patients underwent surgical exploration. The median residual liver volume before treatment was 329.5 (284.9-365.7) ml, and after the combined procedure 415.6 (354.7-718.8) ml. The median hyperplasia ratio was 28.1% (14.1%-51.3%). Eight patients finally underwent surgical resection. There was no death in the perioperative periods. The median tumor-free survival time was 17 (7-42) months, and the median survival time was 27 (7-42) months. Conclusion:For patients with large liver cancer with insufficient remnant liver volume, preoperative TACE+ SPVE has certain value in controlling tumor progression, promoting remnant liver hyperplasia, increasing surgical resection rate and improving prognosis.
5.Effect of ascending medial open-wedge high tibial osteotomy and descending medial open-wedge high tibial osteotomy on patellar height
Baoan PEI ; Shanshan DUAN ; Guodong DU ; Lisheng WU ; Cunhua ZHANG ; Jinhua ZI
Chinese Journal of Orthopaedics 2021;41(8):496-505
Objective:In order to compare the effect of ascending medial open-wedge high tibial osteotomy and descending medial open-wedge high tibial osteotomy on patellar height.Methods:Our group analyzed 77 patients of medical cases which were closely associated with medial open-wedge high tibial osteotomy for the treatment of knee varus deformity and medial compartment osteoarthritis from May 2011 to December 2018 and 77 cases were effectively followed up, including 36 males and 41 females with an average age of 59.4±10.5. By the way, there are 51 cases of ascending osteotomy and 26 cases of descending osteotomy. During these treatment, we adopted some scientific methods full-length standing anteroposterior radiograph,Miniaci method, Insall-Salvati index (ISI), Caton-Deschamps index (CDI) and Blackburne-Peel Index (BPI) to measure the corresponding parameters and changes in patellar height (PH) at different stages.Results:77 patients were enrolled, the mean follow-up time was 20.6 months (range, 12-60 months), ascending and descending high tibial osteotomy (HTO) show the average degree of varus correction (10.43°±2.67° and 11.16°± 2.80°) respectively. And at the same time, in these cases of ascending HTO, PH decreased by 8.1% (CDI method), 2 cases of low PH (the patellar height decreased by 10%, which is the low patellar) were measured (ISI method), 7 cases of low PH occurred (CDI and BPI). Instead, PH decreased by 4.5% (CDI method) in descending HTO,the difference was significant ( t=2.101, P=0.040). 22 cases of ascending HTO with varus correction less than 10 degrees, the PH decreased by 6.9%. By the way, the ISI method did not detect the occurrence of low PH, but we found one by CDI and BPI. The 29 cases with varus correction of more than 10 degrees in ascending HTO, and PH decreased by 10.4%. There were 2 low PH (ISI method), and 6 low PH (CDI and BPI), the difference was significant ( t=2.310, P=0.028). Conclusion:In ascending HTO, the low PH is closely related to the degree of varus correction. Conversely, The descending HTO did not influence PH.
6. Expert consensus on prevention and cardiopulmonary resuscitation for cardiac arrest in COVID-19
Wei SONG ; Yanhong OUYANG ; Yuanshui LIU ; Heping XU ; Feng ZHAN ; Wenteng CHEN ; Jun ZHANG ; Shengyang YI ; Jie WEI ; Xiangdong JIAN ; Deren WANG ; Xianjin DU ; Ying CHEN ; Yingqi ZHANG ; Shuming XIANYU ; Qiong NING ; Xiang LI ; Xiaotong HAN ; Yan CAO ; Tao YU ; Wenwei CAI ; Sheng'Ang ZHOU ; Yu CAO ; Xiaobei CHEN ; Shunjiang XU ; Zong'An LIANG ; Duohu WU ; Fen AI ; Zhong WANG ; Qingyi MENG ; Yuhong MI ; Sisen ZHANG ; Rongjia YANG ; Shouchun YAN ; Wenbin HAN ; Yong LIN ; Chuanyun QIAN ; Wenwu ZHANG ; Yan XIONG ; Jun LV ; Baochi LIU ; Xiaojun HE ; Xuelian SUN ; Yufang CAO ; Tian'En ZHOU
Asian Pacific Journal of Tropical Medicine 2021;14(6):241-253
Background: Cardiopulmonary resuscitation (CPR) strategies in COVID-19 patients differ from those in patients suffering from cardiogenic cardiac arrest. During CPR, both healthcare and non-healthcare workers who provide resuscitation are at risk of infection. The Working Group for Expert Consensus on Prevention and Cardiopulmonary Resuscitation for Cardiac Arrest in COVID-19 has developed this Chinese Expert Consensus to guide clinical practice of CPR in COVID-19 patients. Main recommendations: 1) A medical team should be assigned to evaluate severe and critical COVID-19 for early monitoring of cardiac-arrest warning signs. 2) Psychological counseling and treatment are highly recommended, since sympathetic and vagal abnormalities induced by psychological stress from the COVID-19 pandemic can induce cardiac arrest. 3) Healthcare workers should wear personal protective equipment (PPE). 4) Mouth-to-mouth ventilation should be avoided on patients suspected of having or diagnosed with COVID-19. 5) Hands-only chest compression and mechanical chest compression are recommended. 6) Tracheal-intubation procedures should be optimized and tracheal-intubation strategies should be implemented early. 7) CPR should be provided for 20-30 min. 8) Various factors should be taken into consideration such as the interests of patients and family members, ethics, transmission risks, and laws and regulations governing infectious disease control. Changes in management: The following changes or modifications to CPR strategy in COVID-19 patients are proposed: 1) Healthcare workers should wear PPE. 2) Hands-only chest compression and mechanical chest compression can be implemented to reduce or avoid the spread of viruses by aerosols. 3) Both the benefits to patients and the risk of infection should be considered. 4) Hhealthcare workers should be fully aware of and trained in CPR strategies and procedures specifically for patients with COVID-19.
7.Effect of electronic moxibustion on memory function in patients with amnestic mild cognitive impairment.
Qi-Qi LIU ; Shang-Jie CHEN ; Guo-Ming SHEN ; Xin-Yan JIA ; Xiao-di QIAO ; Guo-Long WU
Chinese Acupuncture & Moxibustion 2020;40(4):352-356
OBJECTIVE:
To observe the effect of electronic moxibustion on memory function in the patients with amnestic mild cognitive impairment (aMCI).
METHODS:
A total of 59 aMCI patients were randomized into an electronic moxibustion group (30 cases) and a placebo moxibustion group (29 cases). In the electronic moxibustion group, the electronic moxibustion was applied to Baihui (GV 20), Dazhui (GV 14), Mingmen (GV 4) and Taixi (KI 3), 45 ℃ in temperature, 20 min each time. The treatment was given once a day, 5 times a week. The treatment for 4 weeks was as one course and 2 courses were required totally. In the placebo moxibustion group, the moxa-free patch was used, 38 ℃ in temperature. The acupoint selection and the treatment frequency were same as the electronic moxibustion group. Before and after treatment, Rivermead behavior memory test (RBMT) was adopted to evaluate the global memory function of the patients in the two groups and the N-back task test was adopted to evaluate working memory function separately. Additionally, the mini-mental state examination (MMSE) and its immediate memory, Montreal cognitive assessment (MoCA) and its delay recall were adopted to evaluate the global cognitive function and memory function
RESULTS:
In the electronic moxibustion group, after treatment, RBMT score, N-back accuracy rates, MMSE and MoCA scores and the scores of immediate memory and delay recall were improved significantly as compared with those before treatment (<0.01). In the placebo moxibustion group, the accuracy rates of 1-back and 2-back task and the scores of immediate memory and delay recall were improved obviously as compared with those before treatment (<0.05, <0.01). After treatment, the improvements of RBMT score, the accuracy rates of N-back task and MMSE and MoCA scores in the electronic moxibustion group were higher than those in the placebo moxibustion group (<0.05).
CONCLUSION
Electronic moxibustion improves memory function in the patients with amnestic mild cognitive impairment.
Acupuncture Points
;
Amnesia
;
therapy
;
Cognitive Dysfunction
;
therapy
;
Humans
;
Memory
;
Mental Status and Dementia Tests
;
Moxibustion
;
methods
8.Identification of RhCcEe Mixed Visual Field in Patients with Regular Blood Transfusion and Efficacy Analysis of the Matched Transfusion.
Yong-Mei YUAN ; Xian LI ; Qing-Wei YANG ; Chang-Lin WU ; Xin-Tang DANG ; Chao-Peng SHAO
Journal of Experimental Hematology 2019;27(3):930-934
OBJECTIVE:
To explore the feasibility of RhCcEe blood group antigen mixed visual field identification in patients with regular blood transfusion, to follow up and evaluate the efficacy of matched transfusion and its clinical significance.
METHODS:
RhCcEe genotyping for 142 patients with regular transfusion in our hospital was carried out by PCR-SSP method. According to the results of genotyping, 48 patients voluntarily selected the continuous transfusion of RhCcEe matched red blood cells, 46 patients received random blood transfusion (RhCcEe mismatched transfusion), 42 patients received partial RhCcEe matched transfusion (unable to provide fully matched RhCcEe donors each time), and 6 patients' blood transfusion data were lost. After 3-6 months of the RhCcEe matched transfusion, all patients were tested by RhCcEe microcolumn gel card and compared with the results before RhCcEe matched transfusion. The positive rates of alloantibodies, DAT and the percentage of red blood cell invalid transfusion were followed up and evaluated for the above-mentsioned 3 types of regular transfusion patients in the past 5 years.
RESULTS:
Out of the 48 patients who underwent conti-nuous RhCcEe matched transfusion, only 1 case showed stratification, the remaining 47 cases had clear gel card results without stratification, suggesting that PCR-SSP genotyping was feasible. In addition, another 42 patients who could not receive RhCcEe matched transfusion each time and 46 patients with random blood transfusion were found to have a mixed vision phenomenon again. but the results was still difficult to confirm the results. For the transfusion results in the past 5 years, follow-up analysis showed that there were 1 case alloantibody (anti-Jka) (1/48) , 1 case of DAT positive (1/48) and 2 cases of invalid transfusion (2/48) in the RhCcEe matched transfusion group; 7 cases of alloantibodies (3 anti-E, 1 anti-E+anti-c, 1 anti-C, 1 anti-M, 1 anti-Fya) (7/46), 6 case of DAT positive (6/46) and 9 case of invalid transfusion (9/46) in the random transfusion group; 6 cases of alloantibodies (1 anti-E, 1 anti-E+autoantibody, 1 anti-C, 1 anti-c, 1 anti-M and 1 other antibody) (6/42) and 7 case of DAT positive (7/42) and 8 case of invalid transfusion (8/42) in the partial RhCcEe matched transfusion group. The statistical analysis showed that the positive rate of alloantibodies and the invalid infusion rate of RBC in each group were significant differences between RhCcEe matched transfusion group and the random transfusion group as well as betwen Rhce fe matched transfusion group and the partial matched transfusion group(P<0.05), but there was no statistical difference between the random transfusion group and the partial matched transfusion group(P>0.05).
CONCLUSION
PCR-SSP genotyping technique can be used to detect RhCcEe mixed vision in patients with regular blood transfusion. Continuous RhCcEe matched transfusion can effectively prevent the occurrence of alloimmunization, and improve the clinical transfusion efficacy and safety of the patients with regular blood transfusion, which has very important clinical significance.
Blood Group Antigens
;
Blood Transfusion
;
Humans
;
Isoantibodies
;
Transfusion Reaction
;
Visual Fields
9. Combined effect of noise and hydrogen cyanide on noise-induced hearing loss in a metal electroplating enterprise
Sheng ZHANG ; Jianguo HUANG ; Jianguo WU ; Jincai CHEN ; Zipeng LAN ; Lilin WEN ; Zhenxi ZHENG ; Hanqin WANG
China Occupational Medicine 2018;45(04):480-484
OBJECTIVE: To study the combined effect of noise and hydrogen cyanide on noise-induced hearing loss( NIHL)in a metal electroplating enterprise. METHODS: The judgment sampling method was used to select 663 workers in a largescale metal electroplating enterprise as the study subjects. Among them,186 workers exposed to noise alone were designated as noise group; 138 workers exposed to hydrogen cyanide alone were designated as hydrogen cyanide group; and161 workers exposed to noise and hydrogen cyanide were designated as combined effect group,and 178 workers without exposure from occupational disease risk factors were designated as control group. Questionnaires survey and pure tone audiometry were used for analyzing the effects of combined noise and hydrogen cyanide exposure on NIHL. RESULTS: The hearing loss detection rate of the study subjects was 40. 4%. The hearing loss detection rates in the control group,noise group,hydrogen cyanide group,and combined effect group were 17. 4%,47. 8%,32. 6% and 64. 0%,respectively. The detection rate of hearing loss in the control group was lower than that in the other three groups( P < 0. 008). The NIHL detection rates in the combined effect group and the noise group were higher than that in the hydrogen cyanide group( P <0. 008). The hearing loss detection rate of the combined effect group was higher than that of the noise group and the hydrogen cyanide group( P < 0. 008). Ordinal multi-categorical logistic regression model results showed that after adjusting confounding factors such as age,length of service,gender,marital status,smoking,alcohol drinking,we found hydrogen cyanide exposure,noise exposure,and combined exposure to hydrogen cyanide and noise had effects on workers' hearing(P < 0. 05). The risk of hearing loss in workers exposed to noise and hydrogen cyanide was higher than that of workers exposed to noise alone or hydrogen cyanide alone. CONCLUSION: There is a combined effect of noise and hydrogen cyanide in this metal electroplating enterprise,which can increase the risk of NIHL in workers.
10.Clinical study on tetrandrine in adjuvant treatment of relapsed/refractory acute leukemia
Jia LI ; Weiying GU ; Banghe DING ; Jun QIAN ; Bin HE ; Lidong ZHAO ; Xue WU ; Xiaoyan MA ; Jian CHENG ; Fei WANG ; Baoan CHEN
Journal of Leukemia & Lymphoma 2018;27(7):385-390
Objective To analyze the efficacy and safety of tetrandrine in the adjuvant treatment of relapsed/refractory acute leukemia (except M3).Methods A total of 58 patients with relapsed/refractory acute leukemia (except M3) admitted to six tertiary hospitals in Jiangsu Province from January 2015 to December 2017 were included in this study.The tetrandrine-adjuvant standard chemotherapy regimen and standard chemotherapy regimen were given to treatment and control groups respectively.There were 17 and 41 patients in treatment and control groups.The treatment group was given tetrandrine for 5 days before the use of standard chemotherapy.The dose of tetrandrine was 4 mg ·kg-1 ·d-1,and patients had continuous oral administration of 5 days.After that,the patients in the treatment group started chemotherapy immediately.On the other side,the control group received standard chemotherapy without any other multidrug reversal medicine.Then the clinical efficacy and safety outcomes in both groups were analyzed.Results In the treatment group,5,3,and 9 cases achieved complete remission (CR),partial remission (PR),and nonremission (NR) respectively,and the total effective (CR+PR) rate was 47.06 % (8/17);in the control group,14,10,and 17 cases achieved CR,PR,and NR,and the total effective rate was 58.54 % (24/41).There was no significant difference in the total effective rate between the two groups (x2 =0.64,P =0.424).There was no significant difference in the efficacy between the two groups of patients with different genders (P > 0.05).When the disease duration was 6-11 months,the difference of efficacy between the two groups was statistically significant (P =0.041).There was no significant difference in the proportion of myeloid leukemia cells,white blood cell count,platelet count,red blood cell count,and hemoglobin between the two groups before and after treatment (all P > 0.05).There was no significant difference in clinical safety indicators (urine,faecal routine,liver and kidney function,and electrocardiogram) between the two groups (all P > 0.05).Conclusions Tetrandrine is more effective in patients with relapsed/refractory acute leukemia (except M3) with shorter duration of disease.Compared with chemotherapy alone,the clinical efficacy of adding tetrandrine in chemotherapy cannot be considered superior to the former.


Result Analysis
Print
Save
E-mail