1.Postoperative urinary retention following hip or knee arthroplasty under spinal anaesthesia with intrathecal morphine: a retrospective cohort study.
Elad DANA ; Oz BEN-ZUR ; Sara DICHTWALD ; Guy FEIGIN ; Noa BRIN ; Michael MARKUSHEVICH ; Brian FREDMAN ; Yaron Shraga BRIN
Singapore medical journal 2025;66(9):481-485
INTRODUCTION:
Postoperative urinary retention (POUR) frequently complicates the course of patients following hip and knee arthroplasty. Intrathecal morphine (ITM) was identified as a significant risk factor for POUR. The objective of this study was to investigate the incidence and risk factors for POUR in fast-track total joint arthroplasty (TJA) under spinal anaesthesia (SA) with ITM.
METHODS:
We conducted a retrospective study of our institutional joint registry of patients who underwent primary TJA under SA with ITM between October 2017 and May 2021. Preoperative (baseline demographics) and perioperative data were collected. The primary outcome was the incidence of POUR after 8 h or earlier, either due to lack of voiding or according to patient's complaints of bladder distension. Univariate and adjusted analyses were performed to identify predictors of POUR.
RESULTS:
Sixty-nine patients who underwent total knee arthroplasty (TKA) and 36 patients who underwent total hip arthroplasty (THA) under SA with ITM were included in the study. POUR requiring bladder catheterisation was diagnosed in 21% of patients. Independent predictors of POUR were age over 65 years and male gender.
CONCLUSIONS
SA with ITM for TJA is associated with high rates of POUR in males older than 65 years of age. Other previously identified risk factors such as intraoperative fluid administration or comorbidities may not be as influential.
Humans
;
Retrospective Studies
;
Male
;
Urinary Retention/epidemiology*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Anesthesia, Spinal/adverse effects*
;
Female
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Morphine/adverse effects*
;
Aged
;
Middle Aged
;
Risk Factors
;
Postoperative Complications/epidemiology*
;
Injections, Spinal
;
Incidence
;
Analgesics, Opioid/adverse effects*
;
Aged, 80 and over
2.Study on Pre-Clinical In-Vitro Test Methods of Unicondylar Knee Prosthesis.
Shu YANG ; Dan HAN ; Wen CUI ; Zhenxian CHEN ; Jinju DING ; Jintao GAO ; Bin LIU
Chinese Journal of Medical Instrumentation 2025;49(1):111-118
Compared with total knee arthroplasty, unicondylar knee replacement has the advantage of preserving the knee tissue structure and motor function to the greatest extent. Pre-clinical in-vitro test is an important tool to evaluate the safety and effectiveness of unicondylar knee prostheses, and it is also a key focus of the product registration process. Through collection, comparison, and analysis of current regulations, technical standards, guidelines, and related research literature, this paper expounds on the relevant research methods for the pre-clinical in-vitrotesting of unicondylar knee prostheses. At the same time, in conjunction with current evaluation requirements and experience, the study discusses the focus of pre-clinical performance research for unicondylar knee prostheses during the registration process to clarify the performance evaluation requirements of this product category. This aims to provide a reference for the pre-clinical performance research of unicondylar knee prostheses and to standardize industry testing standards.
Knee Prosthesis
;
Arthroplasty, Replacement, Knee
;
Humans
;
Prosthesis Design
;
Materials Testing
3.Application of custom-made joint prostheses in wrist.
Xiaodi ZOU ; Yanzhao DONG ; Changxing WANG ; Hui LU
Journal of Zhejiang University. Science. B 2025;26(2):200-202
The wrist joint is a highly mobile functional joint. Wrist conditions including traumatic and degenerative arthritis, rheumatoid arthritis, and giant cell tumors of the distal radius, cause significant pain and mobility impairment. In joint surgery, the decision to use joint prostheses to reconstruct joint function is greatly influenced by the characteristics of the prosthesis (Mok et al., 2016). However, traditional implants have limitations such as shape mismatch, inadequate implant-bone interface strength which causes loosening, and poor bone ingrowth (Zhang et al., 2014).
Humans
;
Joint Prosthesis
;
Wrist Joint/surgery*
;
Prosthesis Design
;
Arthroplasty, Replacement
;
Arthritis, Rheumatoid/surgery*
4.Evolution of temporomandibular joint reconstruction: from autologous tissue transplantation to alloplastic joint replacement.
Hanghang LIU ; Liwei HUANG ; Shibo LIU ; Linyi LIU ; Bolun LI ; Zizhuo ZHENG ; Yao LIU ; Xian LIU ; En LUO
International Journal of Oral Science 2025;17(1):17-17
The reconstruction of the temporomandibular joint presents a multifaceted clinical challenge in the realm of head and neck surgery, underscored by its relatively infrequent occurrence and the lack of comprehensive clinical guidelines. This review aims to elucidate the available approaches for TMJ reconstruction, with a particular emphasis on recent groundbreaking advancements. The current spectrum of TMJ reconstruction integrates diverse surgical techniques, such as costochondral grafting, coronoid process grafting, revascularized fibula transfer, transport distraction osteogenesis, and alloplastic TMJ replacement. Despite the available options, a singular, universally accepted 'gold standard' for reconstructive techniques or materials remains elusive in this field. Our review comprehensively summarizes the current available methods of TMJ reconstruction, focusing on both autologous and alloplastic prostheses. It delves into the differences of each surgical technique and outlines the implications of recent technological advances, such as 3D printing, which hold the promise of enhancing surgical precision and patient outcomes. This evolutionary progress aims not only to improve the immediate results of reconstruction but also to ensure the long-term health and functionality of the TMJ, thereby improving the quality of life for patients with end-stage TMJ disorders.
Humans
;
Temporomandibular Joint/surgery*
;
Temporomandibular Joint Disorders/surgery*
;
Transplantation, Autologous
;
Arthroplasty, Replacement/methods*
;
Joint Prosthesis
;
Plastic Surgery Procedures/methods*
5.Is unicompartmental knee arthroplasty a better choice than total knee arthroplasty for unicompartmental osteoarthritis? A systematic review and meta-analysis of randomized controlled trials.
Kuanyu XIA ; Lang MIN ; Wenqing XIE ; Guang YANG ; Dong Keon YON ; Seung Won LEE ; Ai KOYANAGI ; Louis JACOB ; Lee SMITH ; Jae Il SHIN ; Masoud RAHMATI ; Wenfeng XIAO ; Yusheng LI
Chinese Medical Journal 2025;138(13):1568-1577
BACKGROUND:
The choice of unicompartmental knee arthroplasty (UKA) vs . total knee arthroplasty (TKA) in the surgical treatment of knee osteoarthritis (KOA) remains controversial. This study aimed to perform a systematic review and meta-analysis of randomized controlled trials (RCTs) to compare the clinical results of UKA and TKA for treating unicompartmental KOA.
METHODS:
PubMed, Embase, and the Cochrane Library were systematically searched for articles published up to January 2, 2023. The literature was rigorously screened to include only RCTs comparing UKA and TKA for unicompartmental KOA. A systematic review and meta-analysis were performed to calculate the mean difference (MD), relative risk (RR), and 95% confidence interval (CI) according to the Cochrane standards.
RESULTS:
Thirteen publications involving 683 UKAs and 683 TKAs were analyzed. Except for one study with a follow-up period of 15 years, all outcome measures reported were within 5 years of follow-up. Meta-analysis showed better knee recovery (MD: 1.23; 95% CI: 1.01-1.45; P <0.001), greater knee function (MD: 1.78; 95% CI: 0.34-3.22; P = 0.020), less pain (MD: 0.75; 95% CI: 0.43-1.06; P <0.001), and better health status (MD: 3.75; 95% CI: 0.81-6.69; P = 0.010) after UKA than TKA. However, considering the minimal clinically important difference values for these variables, the findings were not clinically relevant. Moreover, UKA patients had fewer complications (RR: 0.59; 95% CI: 0.45-0.78; P <0.001) and shorter hospital stays (MD: -0.89; 95% CI: -1.57 to -0.22; P = 0.009) than did TKA patients. There were no statistically significant differences in terms of postoperative range of movement, revision, failure, operation time, and patient satisfaction.
CONCLUSIONS
In terms of clinical efficacy, there was no obvious advantage of UKA over TKA in the surgical treatment of knee OA when considering the minimal clinically important difference. The main advantage of UKA over TKA is that it leads to fewer complications and a shorter length of hospital stay. It is ideal to perform prospective studies with longer follow-up periods to fully evaluate the long-term efficacy and safety of the two procedures in the future.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Randomized Controlled Trials as Topic
;
Treatment Outcome
6.Biomechanical effects of medial and lateral translation deviations of femoral components in unicompartmental knee arthroplasty on tibial prosthesis fixation.
Jingting XU ; Jing ZHANG ; Bing ZHANG ; Wen CUI ; Weijie ZHANG ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(1):105-112
Prosthesis loosening is the leading cause of postoperative revision in unicompartmental knee arthroplasty (UKA). The deviation of medial and lateral translational installation of the prosthesis during surgery is a common clinical phenomenon and an important factor in increasing the risk of prosthesis loosening. This study established a UKA finite element model and a bone-prosthesis fixation interface micromotion prediction model. The predicted medial contact force and joint motion of the knee joint from a patient-specific lower extremity musculoskeletal multibody dynamics model of UKA were used as boundary conditions. The effects of 9 femoral component medial and lateral translational installation deviations on the Von Mises stress of the proximal tibia, the contact stress, and the micro-motion of the bone prosthesis fixation interface were quantitatively studied. It was found that compared with the neutral position (a/A of 0.492), the lateral translational deviation of the femoral component significantly increased the tibial Von Mises stress and the bone-prosthesis fixation interface contact stress. The maximum Von Mises stress and the maximum contact stress of the fixation interface increased by 14.08% and 143.15%, respectively, when a/A was 0.361. The medial translational deviation of the femoral component significantly increased the bone-prosthesis fixation interface micro-motion. The maximum value of micromotion under the conditions of femoral neutral and medial translation deviation was in the range of 20-50 μm, which is suitable for osseointegration. Therefore, based on considerations such as the micromotion range suitable for osseointegration reported in the literature, the risk of reducing prosthesis loosening, and factors that may induce pain, it is recommended that clinicians control the mounting position of the femoral component during surgery within the safe range of 0-4 mm medial translation deviation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Knee Prosthesis
;
Tibia/surgery*
;
Femur/surgery*
;
Stress, Mechanical
;
Prosthesis Failure
;
Knee Joint/surgery*
;
Prosthesis Design
7.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
8.Effects of elastic modulus of the metal block on the condylar-constrained knee prosthesis tibial fixation stability.
Yuhan ZHANG ; Jing ZHANG ; Tianqi DONG ; Xuan ZHANG ; Weijie ZHANG ; Lei GUO ; Zhenxian CHEN
Journal of Biomedical Engineering 2025;42(4):782-789
Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated. Results demonstrated that collision between the insert post and femoral prosthesis during tibial internal rotation increased tibial von Mises stress, significantly influencing the prediction of block elastic modulus variation. A decrease in the elastic modulus of the metal block resulted in increased von Mises stress in the proximal tibia, significantly reduced von Mises stress in the distal tibia, decreased von Mises stress of the block, and increased micromotion at the bone-prosthesis fixation interface. When the elastic modulus of the metal block fell below that of bone cement, inadequate block support substantially increased the risk of stress shielding in the distal tibia and fixation interface loosening. Therefore, this study recommends that biomechanical investigations of CCK prostheses must consider the post-constraint effect, and the elastic modulus of metal blocks for bone reconstruction should not be lower than 3 600 MPa.
Knee Prosthesis
;
Humans
;
Finite Element Analysis
;
Tibia/surgery*
;
Elastic Modulus
;
Arthroplasty, Replacement, Knee/methods*
;
Stress, Mechanical
;
Metals
;
Prosthesis Design
;
Knee Joint/surgery*
;
Biomechanical Phenomena
9.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
10.Application of personalized three-dimensional printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Shuailei LI ; Hao CHAI ; Yongqiang SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):13-19
OBJECTIVE:
To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
METHODS:
A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film.
RESULTS:
The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation ( t=-12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the "Lewinneck safety zone". There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side ( P>0.05).
CONCLUSION
The use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
Humans
;
Printing, Three-Dimensional
;
Male
;
Female
;
Middle Aged
;
Acetabulum/surgery*
;
Aged
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Reoperation
;
Treatment Outcome

Result Analysis
Print
Save
E-mail