1.Real-world characteristics and treatment patterns in Chinese patients with newly diagnosed endometrial cancer.
Aijun YIN ; Dong WANG ; Yanlin LUO ; Ruifang AN ; Shuzhong YAO ; Yufei SHEN ; Li SUN ; Cuirong LEI ; Yan TIAN ; Li WANG ; Dan ZHONG ; Manman XU ; Yuanyuan JIANG ; Min ZHANG ; Binqi ZHANG ; Huirong MAO ; Fengshi DONG ; Yu ZHANG ; Beihua KONG
Chinese Medical Journal 2025;138(13):1624-1626
2.Intercomparison of institutions providing individual external exposure monitoring services in Shanghai from 2021 to 2023
Aijun QIAN ; Xuexin WEN ; Linfeng GAO ; Qiaochu YANGFAN ; Jie YAO ; Minpeng HUANG
Journal of Environmental and Occupational Medicine 2024;41(10):1162-1166
Background The monitoring of external radiation individual doses for radiation workers is a statutory task and serves as an important basis for the diagnosis of occupational diseases in this occupational group. Ensuring the accuracy and reliability of monitoring data is crucial for safeguarding the health of radiation workers. Objective To evaluate and compare the capabilities and levels of external radiation individual dose monitoring conducted by radiation hygiene service institutions in Shanghai, to standardize relevant workflows, and to improve the accuracy and reliability of the monitoring service. Methods From 2021 to 2023, annual intercomparisons of external radiation individual dose monitoring capabilities were organized for radiation hygiene service institutions in Shanghai. The study subjects were 19 to 21 radiation hygiene service institutions registered in Shanghai for each year and they all participated in the intercomparisons. The monitoring subjects included 16 district-level centers for disease control and prevention (CDCs) and 13 third-party testing agencies. Monitoring capabilities were analyzed based on single-group performance, comprehensive performance, and Q-value. In the intercomparison, a thermoluminescent dosimetry system was used to perform irradiation tests on thermoluminescence dosimeter [made of lithium fluoride (magnesium, copper, phosphorus), LiF (Mg, Cu, P)], and monitoring data for X-rays and γ-rays at different doses and radiation conditions were analyzed following a standard procedure specified by GBZ 207−2016. Statistical methods included t-test and Kolmogorov-Smirnov test, with statistical significance set at P<0.05. Results From 2021 to 2023, the number of participating institutions was 19, 21, and 19, respectively, with an overall pass rate of 94.9% (56/59). Two institutions failed in 2022 and one in 2023. The number of institutions meeting the excellent standard in single-group and comprehensive performance was 9, 12, and 13, respectively, and the number of institutions ultimately rated as excellent was 3, 7, and 8,respectively, with an overall excellence rate of 30.5% (18/59) and an excellence conversion rate of 52.9%. The pass rates for single-group and comprehensive performance were both 98.3%. The number of groups with negative deviation was 1.86 times that of groups with positive deviation for X-rays, and 1.10 times for γ-rays. For X-rays, there was a statistically significant deviation between doses of less than 1.0 mSv and more than 1.0 mSv (P=0.01), while there was no significant difference in the single-group performance deviation between X-rays and γ-rays at the same dose. There was a statistically significant difference between the reported and reference values for X-rays in 2021 and 2022 (P<0.05), but no significant difference in 2023 (P>0.05); there was no significant difference between the reported and reference values for γ-rays over the three years (P>0.05). Conclusion Over the past three years, the external radiation individual dose monitoring capability intercomparison results of radiation hygiene service institutions in Shanghai have shown that the pass rate remains at a high level, with the excellence rate increasing year by year. However, some institutions still need to improve their monitoring capabilities, and further cooperation among institutions and training for technical staff are needed to enhance the capabilities and standardization of external radiation individual dose monitoring in Shanghai.
3.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
4.Efficacy of balloon dilation percutaneous kyphoplasty combined with prying reduction and bone grafting in the treatment of thoracolumbar fractures
Peng CAO ; Yinchuan HE ; Xueying YAO ; Ran WEI ; Minghao LIU ; Aijun ZHAO ; Junling XU
Chinese Journal of Postgraduates of Medicine 2023;46(9):826-831
Objective:To explore the efficacy of balloon dilation percutaneous kyphoplasty (PKP) combined with prying reduction bone grafting in the treatment of thoracolumbar fractures, and its impact on patients′neurological function.Methods:The clinical data of 184 patients with thoracolumbar fractures from March 2017 to May 2020 in Cangzhou Integrated Traditional Chinese and Western Medicine Hospital of Hebei Province were retrospectively analyzed. Among them, 86 patients were treated with balloon dilation PKP combined with prying reduction and bone grafting (combined group), and 98 patients were treated with open reduction decompression and internal fixation (internal fixation group). The intraoperative bleeding volume, surgical time, intraoperative fluoroscopy frequency, efficacy and complications were recorded. One year after surgery, X-ray films were taken to measure the height of the anterior border and posterior border of vertebral body and the Cobb angle, and the pain visual analogue score (VAS), Barthel index and neurological Frankel grade were evaluated.Results:The intraoperative bleeding volume and surgical time in combined group were significantly higher than those in internal fixation group: (205.64 ± 45.63) ml vs. (180.37 ± 30.08) ml and (110.22 ± 28.91) min vs. (81.66 ± 20.77) min, and there were statistical differences ( P<0.01); there was no statistical difference in intraoperative fluoroscopy frequency between the two groups ( P>0.05). The total effective rate in combined group was significantly higher than that in internal fixation group: 91.86% (79/86) vs. 79.59% (78/98), the total incidence of complications was significantly lower than that in internal fixation group: 13.95% (12/86) vs. 38.78% (38/98), and there were statistical differences ( P<0.05 or <0.01). The height of the anterior border and posterior border of vertebral body 1 year after surgery in combined group were significantly higher than those in internal fixation group: (95.78 ± 1.59) mm vs. (62.74 ± 1.80) mm and (98.53 ± 3.80) mm vs. (95.06 ± 3.28) mm, the Cobb angle was significantly smaller than that in internal fixation group: (6.53 ± 2.80)° vs. (18.06 ± 2.68)°, and there were statistical differences ( P<0.01). The VAS and Barthel index 1 year after surgery in both groups improved significantly, and there were statistical differences ( P<0.01), but there were no statistical differences between the two groups ( P>0.05). The rate of neurological Frankel grade E 1 year after surgery in combined group was significantly higher than that in internal fixation group: 56.98% (49/86) vs. 23.47% (23/98), and there was statistical difference ( P<0.01). Conclusions:Compared with open reduction decompression and internal fixation, the balloon dilation PKP combined with prying reduction and bone grafting patients with thoracolumbar fractures is better for vertebral reduction and deformity repair, with higher safety, more significant pain relief, and better recovery of daily life and neurological function.
5.Isolation and genome-wide evolutionary analysis of a type Ⅲ WU polyomavirus strain
Yiman HUANG ; Aijun CHEN ; Chao WANG ; Tianli WEI ; Zhuang HU ; Shanshan CONG ; Jingjing TAN ; Lihong YAO ; Lishu ZHENG
Chinese Journal of Microbiology and Immunology 2023;43(3):182-190
Objective:To isolate and culture WU polyomavirus (WUPyV), and to analyze the genome-wide evolutionary patterns, homology and population dynamics.Methods:Real-time quantitative PCR was used to detect the nasopharyngeal aspirate samples of hospitalized children with respiratory tract infection in Beijing Friendship Hospital during 2020 to 2022. Primary human airway epithelial cells cultured at the air-liquid interface were used to isolate and culture WUPyV. Whole genome sequence of the isolated strain was obtained by Sanger sequencing. For phylogenetic and evolutionary dynamics analysis, the whole genome was compared with the published whole genome sequences in GenBank database.Results:The detection rate of WUPyV was 4.7% (31/659) during 2020 to 2022, and a clinical strain BJ0593 of WUPyV type Ⅲc was successfully isolated. The homology of the whole genome and gene fragments of WUPyV was high. The average evolutionary rate of VP2 gene was about 1.256×10 -4 substitution/site every year, and the population dynamics of WUPyV tended to be flat in the last decade. Conclusions:This study successfully isolated a clinical WUPyV type Ⅲ strain for the first time, which provided the basis for further investigation on the molecular evolution and pathogenicity of WUPyV.
6.Effectiveness of personal dose monitoring intercomparison results in a laboratory in Shanghai
Hong XIAO ; Linfeng GAO ; Jie YAO ; Aijun QIAN ; Bin WANG ; Zhou JIANG ; Weiye YUAN ; Jiangtao BAI ; Shunqi LU ; Zenghe XIU
Journal of Environmental and Occupational Medicine 2023;40(5):571-576
Background Individual monitoring of occupational external exposure is an essential part of the occupational health management of radiation workers, and is an important basis for the evaluation of individual absorbed dose and the diagnosis of occupational radiation diseases. Continuous participation of monitoring service providers in intercomparison is a fundamental quality assurance for routine monitoring, which can identify problems and improve them in time. Objective Taking the Laboratory of Radiation Protection in Shanghai Institute of Preventive Medicine as an example, to evaluate the performance of an individual occupational external dose monitoring system in the laboratory, identify influencing factors of the monitoring results, and provide a basis for improving the quality of daily monitoring by analyzing the process and results of a national intercomparison of individual dose monitoring. Methods According to the Testing criteria of personnel dosimetry performance for external exposure (GBZ 207-2016), and the relevant requirements of Class II (photon) inspection, a total of 20 groups of blind sample dosimeters were measured for four consecutive years from 2018 to 2021. The radiation energy source of each group was identified, and related personal dose equivalent Hp(10), the uncertainty of measurement results, and the deviation between the reported value and the reference value were calculated. The national intercomparison process and results of individual dose monitoring were also analyzed. Results The energy sources of the blind samples in the tested laboratory for four years were N100 or Cs-137. The reported dose values of the blind samples were 0.57-4.61 mSv, the combined uncertainties were 0.043-0.365 mSv, the expanded uncertainties (k=2) were 0.09-0.73 mSv, and the relative expanded uncertainties (k=2) were 13.8%-16.4%. The single-group performance ∣Pi∣ of 20 sets of blind samples in the four years was ≤0.10, the yearly comprehensive performance of 5 sets of blind samples was ≤0.10, and the yearly Q score of the test report was >15 points. The laboratory achieved excellent results in the national intercomparison of individual dose monitoring in four consecutive years, except the Q value not reaching full score. Conclusion The laboratory exhibits standardized data processing of individual dose monitoring, generates accurate and reliable results, and meets the requirements of relevant national standards; but it should continue to participate in the national intercomparison of individual dose monitoring, strengthen the angular response research of energy identified dosimeter, improve the monitoring ability of low-dose X-rays, analyze the key points of reducing the uncertainty of measurement results, and continuously improve the monitoring ability.
7.Feasibility study of predicting dose of radioiodine in hyperthyroidism patients based on neural network
Weiye YUAN ; Jie YAO ; Zhou JIANG ; Hong XIAO ; Aijun QIAN ; Bin WANG ; Jiangtao BAI ; Linfeng GAO
Chinese Journal of Radiological Medicine and Protection 2022;42(2):130-136
Objective:To construct back propagation (BP) neural network model to predict the dose required for 131I therapy for hyperthyroidism and to calculate the personalized dose plan for patients. Methods:A complete set of data of patients treated for hyperthyroidism radioaiodine was collected from the nuclear medicine departments of several medical colleges in Shanghai, including history, examination result, treatment course, etc. As a result, a prediction model was established. The predicated result for BP neural network, radial basis function (RBF) neural network and Support Vector Machine (SVM) were compared by means of small sample data. The optimal model was selected to predict administrated dose and to finally test the accuracy of the model.Results:The average errors in BP neural network, RBF neural network and SVM model based on small samples were 5.53%, 7.09% and 9.64%, respectively. After comparison, BP neural network was selected to build the prediction model. 30 cases of data were selected by random sampling to verify the BP neural network. The mean error, mean square error, minimum error and maximum error of the prediction result were 7.22%, 0.053, 0.57% and 13.78%, respectively.Conclusions:In this study, a neural network prediction method was proposed to provide a more accurate dose for patients in need of radioiodine therap for hyperthyroidism, and to reduce the possibility of radiation damage or the unsatisfactory therapeutic effect caused by insufficient dose. It has clinical practical significance in providing the reference for clinicians to evaluate the administrated dose.
8.Investigation on current radiological examinations in Jinshan district of Shanghai based on the health information platform
Hong XIAO ; Linfeng GAO ; Jie YAO ; Aijun QIAN ; Bin WANG ; Zhou JIANG
Chinese Journal of Radiological Medicine and Protection 2022;42(5):379-384
Objective:To investigate the characteristics of diagnostic radiology and the situation of repeated examinations at medical institutions of Jinshan district, and put forward strategies and suggestions for the correct guidance on and reasonable applications of various medical exposures.Methods:The cases data on radiological examinations at medical institutions in Jinshan district, obtained in 2017 from Shanghai Municipal Health Commission Information Center Platform, was used to describe the characteristics of population distribution of patients, examination types, examination areas, diagnosed diseases, number of repeated examinations and the result of radiological examinations.Results:The main types of radiological examinations in Jinshan district were the CT scans and the conventional X-ray diagnosis, accounted respectively for 53.2% and 44.7% of the total radiological examinations. The radiological examinations were mainly performed on household registration (77.3%). The number of radiological examinations on males was close to on females, with examination frequency of 49.4% for males and 50.1% for females. The greatest frequency of radiological examinations was found in the age group older than 41 years, accounting for 77.1% of CT scans and 65.2% of the conventional X-ray diagnosis. The main examination sites of the CT scans at Jinshan medical institutions were chest (32.8%), abdomen (19.4%), brain (16.1%) and spine (11.4%), and for the conventional X-ray diagnosis were chest (43.2%) and limbs (39.6%). The main departments applying for radiological examinations are surgery (39.7%) and medicine (27.1%). The numbers of radiological examinations are, respectively, diseases of the respiratory system (19.8%), the injury, poisoning and some other consequences of external causes (15.8%), and the diseases of musculoskeletal system and connective tissue (15.8%). The positive rate of the conventional X-ray diagnosis was 53.1%, and the positive rate of CT scans was 73.5%. The conventional X-ray diagnosis and CT scans contributed higher specific rates of repeated examinations, accounting for 9.3% and 7.9% of the total of such type examination, respectively.Conclusions:CT scans in Jinshan district accounted for more than half of the total frequency of radiological examinations, therefore, interventions should be imposed on certain types of phycians and patients types.
9.An investigation of radiation dose to adult subjects in computed tomography scanning in Shanghai, China
Aijun QIAN ; Linfeng GAO ; Jie YAO ; Xuexin WEN ; Bin WANG ; Hong XIAO ; Zhou JIANG
Chinese Journal of Radiological Health 2022;31(5):587-591
Objective To investigate dose parameters in computed tomography (CT) scanning of common body parts inall public medical institutions in Shanghai, China, and analyze the dose distribution of CT scanning among adult subjects in Shanghai, and to provide a basis for establishing the diagnostic reference levels of CT scanning in Shanghai. Methods We selected at least one medical institution with CT services each from all 16 districts of Shanghai. In each medical institution, a piece of CT equipment with qualified annual inspection was sampled to investigate the doses to subjects in head, chest, abdomen, and lumbar spine scanning. We collected the basic information of the subjects, CT scanning parameters, volumetric CT dose index (CTDIvol), and dose length product (DLP). Results The scanning data of 1475 subjects were obtained. The 75th percentiles of the CTDIvol of the head, chest, abdomen, and lumbar spine were 57 mGy, 11 mGy, 16 mGy, and 23 mGy, respectively. The 75th percentiles of the DLP were 862 mGy·cm, 361 mGy·cm, 593 mGy·cm, and 550 mGy·cm, respectively. Conclusion CTDIvol and DLP differed significantly at different body parts, and also differed greatly at the same body parts. The DLP of men was slightly higher than that of women.
10.Monitoring on individual dose among radiation workers in medical institutions in Shanghai from 2015 to 2019
Aijun QIAN ; Xuexin WEN ; Linfeng GAO ; Jie YAO
Shanghai Journal of Preventive Medicine 2022;34(7):634-637
ObjectiveTo determine the individual dose level and changing trend in the occupational external exposure of radiation workers in Shanghai, and provide scientific evidence for health risk assessment for radiation workers. MethodsIn the Occupational Health Management System for Radiation Workers of the National Health Commission-External Exposure Personal Monitoring and Management Subsystem, we retrieved the monitoring data of 38 077 external exposure individual dose of all medical radiation workers in Shanghai from 2015 to 2019. Using clustered sampling method, a total of 11 370 radiation workers in medical institutions (including tertiary, secondary, and primary hospitals) were selected in the study. Statistical analyses were conducted using SPSS 22.0. ResultsThe collective annual effective dose of 11 370 radiation workers was determined to be 4.340 person Sv, including 2.270 man·mSv in diagnostic radiology, 1.112 man·mSv in interventional radiology, and <0.5 man·mSv in other categories. The average annual effective dose was 0.382 mSv, which was 0.482 mSv in nuclear medicine, 0.431 mSv in radiotherapy, and <0.5 mSv in other categories. Moreover, the average annual effective dose of 6 workers (0.05%) was higher than 5 mSv, whereas that of 10 453 workers (92%) were less than 1 mSv; in addition, the annual dose of 911 workers (8.0%) was between 1‒5 mSv. All workers had average annual effctive dose lower than 20 mSv. The annual effective dose differed significantly by years (F=161.1, P<0.01), by occupational groups (F=13.5, P<0.01), and by hospital levels (F=264.5, P<0.01). ConclusionThe average annual effective dose of radiation workers in medical institutions in Shanghai is lower than the national standard limit, suggesting proper and adequate radiation protection system and measures in medical institutions.


Result Analysis
Print
Save
E-mail