1.Analysis of the Burden of Acute Lymphoid Leukemia in China and Globally from 1990 to 2021
Derong LIN ; Jingya FANG ; Yue LI ; Xiaohua XIE ; Xiaolin YE ; Xiaowen ZHANG ; Jiexuan LI ; Aiguo XUE
Medical Journal of Peking Union Medical College Hospital 2026;17(2):463-475
To analyze the disease burden of acute lymphoid leukemia(ALL) and its changing trends in China and globally from 1990 to 2021, aiming to provide a theoretical basis for disease prevention, treatment, and policy formulation. Data on the incidence, prevalence, mortality, and disability adjusted life years(DALYs) of ALL in China and globally from 1990 to 2021 were extracted from the Global Burden of Disease(GBD) 2021 database. The Joinpoint regression model was used to calculate the average annual percentage change(AAPC) to assess the trends in disease burden. Decomposition analysis was employed to identify and quantify the contributions of different factors to the changes in ALL disease burden. The population attributable fraction(PAF) was used to compare the risk factors for ALL in China and globally in 1990 and 2021. Stratified by the sociodemographic index(SDI), the locally estimated scatterplot smoothing(LOESS) method was used to assess the association between age-standardized incidence rate(ASIR), age-standardized mortality rate(ASMR), and SDI. The incidence-mortality ratio(IMR) was calculated to evaluate the diagnostic level and current treatment status of ALL. From 1990 to 2021, ASIR of ALL in the Chinese population increased from 3.385/100 000 to 3.637/100 000(AAPC: 0.005), the age-standardized prevalence rate(ASPR) increased from 6.596/100 000 to 22.022/100 000(AAPC: 0.478), the ASMR decreased from 3.051/100 000 to 1.357/100 000(AAPC: -0.056), and the age-standardized DALYs rate(ASDR) decreased from 195.792/100 000 to 74.063/100 000(AAPC: -3.996). Globally, the corresponding figures were: ASIR decreased from 1.789/100 000 to 1.371/100 000(AAPC: -0.014), ASPR increased from 4.122/100 000 to 5.425/100 000(AAPC: 0.039), ASMR decreased from 1.551/100 000 to 0.898/100 000(AAPC: -0.021), and ASDR decreased from 94.894/100 000 to 48.858/100 000(AAPC: -1.494). During this period, the aforementioned disease burden indicators were generally higher in males than in females, both in China and globally.In 2021, the peak incidence of ALL in China and globally was primarily concentrated in the 0-19 years age group, with the highest rate observed in those under 5 years of age. The burden of prevalence and DALYs was also mainly concentrated in this age group. Regarding mortality, the death burden in China was predominantly observed in the older adult age group, particularly among those aged ≥60 years. Globally, the mortality burden was highest in the under-5 age group, while remaining at a relatively high level in the older adult population. SDI correlation analysis based on data from 204 countries/regions globally from 1990 to 2021 showed that ASIR gradually increased with increasing SDI, whereas ASMR showed an initial increase followed by a decreasing trend. The ASIR and ASMR for the overall Chinese population and by sex were higher than expected. PAF results indicated that smoking and high body mass index were the main attributable risk factors for ALL mortality and DALYs burden, with their contribution consistently increasing. Decomposition analysis revealed that population growth and epidemiological changes were the primary drivers behind the changes in ALL incidence and mortality burden. Compared with 1990, the IMR for ALL in both China and globally increased in 2021. Over the past three decades, the ASMR and ASDR for ALL in China and globally have generally declined. During the same period, the ASIR and ASPR for ALL increased in China, while globally, the ASIR decreased and the ASPR increased. However, the disease burden of ALL remains high in males, children, and the older adult population. Differentiated prevention and control measures should be implemented in accordance with changes in SDI. The findings highlight the importance of strengthening prevention and early diagnosis, and suggest the need for targeted screening and treatment strategies for different age and sex groups. Concurrently, attention should be paid to the role of weight management and tobacco control in comprehensive prevention and control efforts to further reduce the disease burden of ALL.
2.3D-printed metal augment or integrated acetabular prosthesis for reconstruction of bone defects in hip revision
Bo SUN ; Kewei LI ; Shaohua WANG ; Aiguo WANG ; Wei MEI ; Jinliang WANG
Chinese Journal of Orthopaedics 2025;45(2):94-101
Objective:To investigate the clinical efficacy of 3D-printed metal augment or integrated acetabular prostheses for reconstruction of bone defects in hip revision.Methods:A total of 11 patients who underwent total hip revision in Zhengzhou Orthopaedic Hospital from June 2021 to July 2023 were retrospectively analysed. There were 5 males and 6 females, age 64.8±10.7 years (range, 58-75 years), and body mass index 23.3±4.8 kg/m 2 (range, 21-27 kg/m 2). Paprosky classification of acetabular bone defects: 3 cases of type IIA, 4 cases of type IIB, 3 cases of type IIIA, 1 case of type IIIB. Reasons for revision: 8 cases of aseptic loosening, 3 cases after infection exclusion procedure. A 3D-printed metal augment was used in 9 cases (8 cases of aseptic loosening and 1 case of infected exclusion procedure) and a 3D-printed integrated acetabulum was used in 2 cases (infected exclusion procedure). The time from primary total hip arthroplasty to revision was 11.8±5.6 years (range, 5-17 years). Harris hip score and visual analogue scale (VAS) were used to evaluate the improvement of hip function and pain recovery. The leg length discrepancy, vertical height and horizontal position of the hip rotation center were measured on pelvic anteroposterior X-ray films. Results:All patients successfully completed the operation. The operation time was 145.9±35.5 min (range, 110-159 min), and the intraoperative blood loss was 950.5±310.8 ml (range, 680-1,450 ml). The postoperative Harris hip function score was significantly higher than that before operation ( F=554.085, P<0.001). One year after operation, the Harris hip function score was 74.36±5.16, which was higher than that before operation 32.18±4.07, and the difference was statistically significant ( P<0.05). The VAS scores of all patients decreased after operation, and the difference was statistically significant compared with that before operation ( F=177.717, P<0.001). The VAS score at 1 year after operation was 1.27±0.65, which was lower than that before operation 6.18±1.17, and the difference was statistically significant ( P<0.05). The preoperative leg length discrepancy was 1.97±0.71 cm, which was greater than 0.69±0.52 cm at the last follow-up, and the difference was statistically significant ( t=4.824, P<0.001). The vertical height of the hip rotation center was 1.88±0.46 cm on the affected side and 1.67±0.35 cm on the healthy side, showing no significant difference ( t=1.205, P=0.242). The postoperative horizontal position of the hip rotation center was 3.48±0.55 cm on the affected side and 3.54±0.32 cm on the healthy side, and the difference was no statistically significant ( t=-0.313, P=0.758). One case had an intraoperative greater trochanteric fracture that healed 3 months after reduction and internal fixation. All patients were followed up for 21.3±9.5 months (range, 15-31 months). All incisions healed in one stage, and all patients were fully weight-bearing at 3 months after operation. At the last follow-up, there was no case of loosening, dislocation or infection of the prosthesis; 4 cases had mild claudication, 1 case had heterotopic ossification, and the patients had good hip flexion and extension functions, which did not affect daily life without further treatment. Conclusion:The clinical efficacy of 3D-printed metal augment or integrated acetabular prosthesis for reconstruction of acetabular bone defects is satisfactory, which can restore the normal center of rotation of the hip joint and has a low incidence of postoperative complications.
3.Research on surgical treatment strategies for Mason type III radial head fracture complicated with adult Bado type II Monteggia fracture
Dawei ZHANG ; Honghao CHEN ; Kun WANG ; Jiangming QI ; Yugang PAN ; Shijun ZHENG ; Aiguo WANG ; Yejun ZHA ; Maoqi GONG ; Dongsheng LI
Chinese Journal of Orthopaedics 2025;45(13):848-855
Objective:To explore the surgical treatment strategies for Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures.Methods:A retrospective analysis was performed on the clinical data of 25 adult patients with Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures, admitted to the Upper Extremity Orthopaedics Department of Zhengzhou Orthopaedic Hospital from June 2013 to June 2023. There were 15 males and 10 females, with an average age of 43.5±14.7 years (range: 20-67 years). Among them, 5 cases were complicated with humeroulnar joint dislocation. The patients were divided into two groups: 17 cases were treated with open reduction and internal fixation (ORIF) of radial head fractures combined with ORIF of proximal ulnar fractures (open reduction group), and 8 cases were treated with radial head replacement combined with ORIF of proximal ulnar fractures (radial head replacement group). At the last follow-up, elbow joint range of motion was recorded, and pain, elbow function, and subjective upper limb function were evaluated using the Visual Analogue Scale (VAS), Mayo Elbow Performance Score (MEPS), and Disabilities of the Arm, Shoulder and Hand (DASH) scale. The incidence of complications was also recorded.Results:All 25 patients were followed up for an average of 25.6±9.0 months (range: 12-45 months). At the last follow-up, the affected elbows in the open reduction group had a flexion of 124.47°±12.59° (range, 90°-140°), extension of 21.12°±10.07° (range, 10°-50°), pronation of 48.59°±11.62° (range, 20°-61°), and supination of 48.53°±8.43° (range, 30°-60°). In the radial head replacement group, the affected elbows showed flexion of 128.75°±13.17° (range, 100°-140°), extension of 14.00°±7.71° (range, 0°-25°), pronation of 61.25°±10.26° (range, 60°-80°), and supination of 71.88°±10.33° (range, 60°-80°). The MEPS score in the open reduction group was 82(75, 85) points (range, 55-90 points), the VAS pain score was 1(1, 2) points (range, 0-3 points), and the DASH score was 9(8, 14) points. In the radial head replacement group, the MEPS score was 90(85, 90) points (range, 85-90 points), the VAS pain score was 1(0, 1) points (range, 0-1 points), and the DASH score was 5(5, 6) points. Complications included 5 cases of heterotopic ossification, 1 case of incision infection, 1 case of nonunion, 1 case of ulnar nerve injury combined with traumatic arthritis, and 1 case of proximal radioulnar bone bridge formation.Conclusions:Both radial head replacement and open reduction internal fixation combined with proximal ulnar fracture fixation can effectively treat Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures. There was no significant difference in postoperative flexion and extension, but the radial head replacement group demonstrated better forearm rotation and DASH scores postoperatively.
4.Safety and efficacy of the reamer-irrigator-aspirator technique in adult lower extremity long bone nonunion
Hui DONG ; Wenxiang LI ; Liangyu ZHU ; Wei YUAN ; Aiguo WANG ; Xinghua LI
Chinese Journal of Orthopaedics 2025;45(20):1327-1334
Objective:To compare the clinical efficacy of the reamer-irrigator-aspirator (RIA) technique and iliac crest bone grafting (ICBG) in the treatment of adult noninfectious long bone nonunion of the lower extremity, and to evaluate the safety and effectiveness of the RIA technique.Methods:A retrospective review was conducted of 42 adult patients with noninfectious long bone nonunion of the lower extremity treated surgically at Zhengzhou Orthopaedic Hospital from January 2021 to June 2024. The cohort included 33 men and 9 women with a mean age of 47.0±14.4 years (range, 18-62 years). Twenty-three patients had nonunion on the left side and 19 on the right. Initial surgical fixation methods included plate fixation (19 cases), intramedullary nail (16 cases), external fixator (5 cases), and combined plate-and-nail fixation (2 cases). Revision procedures included debridement and freshening of the nonunion ends, revision or adjustment of internal fixation, and autologous bone grafting. Nineteen patients underwent graft harvesting with the RIA technique (RIA group), and 23 received autograft harvested from the iliac crest (iliac group). Baseline and perioperative variables compared between the two groups included sex, age, body-mass index, preoperative comorbidities, anatomical site of the nonunion (tibial or femoral), duration from the index fracture operation to the current revision, operative time, intraoperative blood loss, volume of blood transfusion and rate of perioperative complications, nonunion fracture sites, visual analogue scale (VAS) pain score at the fracture site, donor-site morphology and functional appearance scores, and radiographic union score for tibial fractures (RUST).Results:There was no significant difference in age between the RIA and ICBG groups (45.1±14.1 vs. 48.5±14.7 years, t=0.746, P=0.449). However, intraoperative blood loss was higher in the RIA group [300 (150, 720) ml, Z=-3.072, P=0.002] and the transfusion rate was higher (14/19 vs. 8/23, χ 2=6.313, P=0.012). The harvested bone volume was very similar [40(35, 60) cm 2vs. 40(35, 40) cm 2, Z=-1.077, P=0.281]. All patients were followed for a mean of 16.5±2.8 months (range, 7-40 months). VAS scores at the surgical site showed no significant difference between groups at 3 months (3.2±1.0 vs. 3.3±1.4, t= 4.754, P=0.720) and 6 months (1.6±0.8 vs. 1.8±1.2, t=6.841, P=0.542). Donor-site morphology and functional scores were significantly better in the RIA group at 3 months [14.5(13.0, 15.5) vs. 9.0(7.0, 10.0), Z=-3.748, P<0.001] and 6 months [15.5(15.0, 16.0) vs. 11.0(10.0, 13.0), Z=-3.782, P<0.001]. At 12 months postoperatively, RUST scores did not differ significantly between groups (10.6±1.2 vs. 10.4±1.5, t=0.483, P=0.632). The incidence of perioperative complications was comparable [42%(8/19) vs. 30%(7/23), χ 2=0.617, P=0.432]. Conclusions:Both RIA and ICBG achieved favorable clinical outcomes in the treatment of adult noninfectious lower-extremity long bone nonunion. Although RIA was associated with greater intraoperative blood loss, it resulted in less donor-site morbidity and better cosmetic and functional outcomes. Bone healing capacity and overall complication rates did not differ significantly between the two groups. These findings suggest that the RIA technique is safe and effective for use in the Chinese patient population.
5.Application of the reaming-irrigation-aspirator technique in autologous bone grafting for non-union of lower limb fracture
Yanxin SHI ; Aiguo WANG ; Hui DONG ; Liangyu ZHU ; Wenxiang LI ; Xinghua LI
Chinese Journal of Orthopaedic Trauma 2025;27(3):216-221
Objective:To evaluate the application of the reaming-irrigation-aspirator (RIA) technique in autologous bone grafting for non-union of lower limb fracture.Methods:A retrospective analysis was conducted of the data of 16 patients with non-union of lower limb fracture who had undergone autologous bone grafting using the RIA technique at Department of Lower Limb Orthopaedics Ⅰ, Zhengzhou Orthopaedic Hospital from July 2023 to March 2024. There were 12 males and 4 females with an age of (47.2±14.3) years. Sites of non-union: the femur in 14 cases and the tibia in 2 cases. Initial surgical fixation: intramedullary nail fixation in 5 cases, plate fixation in 10 cases, and intramedullary nail plus plate fixation in 1 case. The time for fracture non-union was (21.0±12.0) months. Intraoperatively, autologous bone reaming was conducted using a drill bit of RIA system, and simultaneous flushing using irrigation fluid. The bone debris carried out by the irrigation fluid was collected into a filtration device through negative pressure aspiration. After the filter was opened to squeeze out congestion, bone paste was taken out for standby. Internal fixation methods were adjusted according to the non-union condition of the fractures. Finally, the bone paste was implanted into bone defects. The time for autologous bone harvest, amount of bone harvested, intraoperative blood loss, postoperative pain at a donor site, fracture healing, functional recovery of a lower limb and occurrence of complications were recorded.Results:In 2 of the 16 patients, fracture of the RIA drill bit occurred when bone marrow was harvested from the tibia, and their operation was completed only after the drill bits were replaced. In the 16 patients, time for bone harvest was (31.4±6.1) min, bone harvest volume (42.6±9.5) mL, and intraoperative blood loss (815.6±238.6) mL. The incisions in this cohort healed primarily after operation, and 4-week follow-up revealed that no patients had pain symptoms at a donor site. The 16 patients were followed up for (8.0±2.0) months after operation. All patients achieved bone union after (4.4±0.5) months. Follow-ups showed that no patients had complications like delayed infection, donor site fracture, or loosening or fracture of an internal fixator. According to the rating scale for lower limb function at the last follow-up, the function of affected limb was evaluated as excellent in 7 cases, as good in 8 cases, and as fair in 1 case.Conclusion:Application of RIA technique for autologous bone grafting to treat non-union of lower limb fracture can lead to fine fracture healing and good lower limb function, but no long-term pain symptoms in the donor area for the patients.
6.A new classification system applied to irreducible intertrochanteric femoral fractures: a multi-center efficacy analysis
Wei ZHANG ; Aiguo WANG ; Shijun ZHAO ; Peng XIAO ; Zhi ZHU ; Wei CHEN ; Zhennan ZHANG ; Xiang LI
Chinese Journal of Orthopaedic Trauma 2025;27(11):926-934
Objective:To explore the efficacy of a new classification system proposed by us applied to the treatment of irreducible intertrochanteric femoral fractures.Methods:A retrospective study was conducted to analyze the clinical data of the 225 patients with irreducible intertrochanteric femoral fracture who had been treated between January 2023 and November 2024 at Zhengzhou Orthopedic Hospital (78 cases), The First Affiliated Hospital of Zhengzhou University (61 cases), Zhengzhou Central Hospital Affiliated to Zhengzhou University (28 cases), Zhengzhou Hospital of Traditional Chinese Medicine (34 cases), and Puyang Hospital of Traditional Chinese Medicine (24 cases). There were 86 males and 139 females, with an age of (74.8±7.9) years. Satisfactory reduction had failed in all patients even after 3 attempts at closed reduction. The patients were divided into 2 groups based on whether the new classification system proposed by our research team in our previous study was used to guide the treatment. The observation group of 116 cases were treated through an extended incision at the head of the intramedullary nail for reduction and fixation under the guidance of the new classification system while the control group of 109 cases were treated by reduction and fixation through a direct anterolateral incision. The operation time, intraoperative blood loss, fracture healing time, Harris hip scores at 3 months after operation and the last follow-up, and incidence of complications were compared between the 2 groups.Results:No statistically significant differences were observed in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (12.6±2.5) months after operation. The operation time, intraoperative blood loss, and fracture healing time [(39.5±9.7) minutes, (106.6±54.8) mL, and (3.1±0.7) months] in the observation group were significantly less than those in the control group [(70.2±11.1) minutes, (322.8±55.5) mL, and (4.5±0.7) months] ( P<0.05). The Harris hip scores at 3 months after operation and the last follow-up in the observation group [(90.3±3.4) points and (93.7±3.2) points] were significantly higher than those in the control group [(75.1±3.8) points and (78.7±3.6) points] ( P<0.05). The incidence of complications in the observation group was 6.0% (7/116), significantly lower than that in the control group [14.7% (16/109)] ( P<0.05). Conclusion:In the treatment of irreducible intertrochanteric femoral fractures, compared with the conventional anterolateral approach for intramedullary nailing, the extended intramedullary head nail approach guided by our new classification system can reduce operation time, intraoperative blood loss, fracture healing time, and incidence of postoperative complications, and improve postoperative hip joint function.
7.Clinical efficacy of arthroscopic limited excision of flexor hallucis longus tendon sheath combined with open technique of posterior ankle joint capsule for hallucal ganglion cyst deriving from ankle joint
Yunjia HAO ; Jie LI ; Jianchao CHANG ; Jiaqiang FAN ; Zexiang LYU ; Buqing CHANG ; Youlun TAO ; Aiguo WANG
Chinese Journal of Surgery 2025;63(9):829-835
Objective:To investigate the feasibility and clinical effect of arthroscopic limited excision of flexor hallucis longus(FHL) tendon sheath combined with open technique of posterior ankle joint capsule for hallucal ganglion cyst(HGC) deriving from the ankle joint.Methods:This is a retrospective case series study. From September 2021 to September 2023, the clinical data of 18 patients (18 feet) with HGC deriving from ankle joint treated by arthroscopic limited excision of FHL tendon sheath combined with posterior ankle capsule opening technique at Department of Orthopedic, Xuzhou Central Hospital were analyzed retrospectively. There were 12 males and 6 females. The age was (49.5±10.7) years (range:32 to 66 years). There were 10 cases on the right side and 8 cases on the left side; 11 cases in fibular, 3 cases in plantar, 2 cases in tibial and 2 cases in tip. There were 8 cases of primary operation and 12 cases of recurrence after resection in other hospital. There were 10 cases with complete skin and soft tissue and 8 cases with ulcer.All patients underwent arthroscopic limited excision of FHL tendon sheath combined with open technique of posterior ankle joint capsule.Clinical evaluations included the American Orthopedic Foot and Ankle Society ankle-hindfoot score(AOFAS-AH), visual analog scale (VAS). The data were compared by paired sample t test and Wilcoxon rank sum test. Results:All cases successfully completed the operation. The operation time was (46.3±8.1) minutes (range:35 to 65 minutes), and the intraoperative blood loss was (6.8±3.1)ml (range:2 to 15 ml). All patients primarily healing without any complications such as infection and skin necrosis. All 18 patients were followed up for (16.3±2.9) months (range:12 to 20 months),and no recurrence. One patient complained of numbness of tibial nerve innervation, and the symptoms disappeared after 3 months of symptomatic treatment with oral mecobalamin. At the last follow-up, the AOFAS-AH significantly improved from 78.9±7.1 (range:65 to 90) preoperatively to 95.8±3.3 (range:89 to 100) postoperatively ( t=9.62, P<0.01). The VAS ( M(IQR)) was reduced from 3(4) preoperatively to 0(1) postoperatively ( Z=-3.75, P<0.01). Conclusions:Arthroscopic limited excision of FHL tendon sheath combined with open technique of posterior ankle joint capsule is an effective and feasible surgery, which realizes accurate and minimally invasive treatment process and good short-term clinical effect.
8.3D-printed metal augment or integrated acetabular prosthesis for reconstruction of bone defects in hip revision
Bo SUN ; Kewei LI ; Shaohua WANG ; Aiguo WANG ; Wei MEI ; Jinliang WANG
Chinese Journal of Orthopaedics 2025;45(2):94-101
Objective:To investigate the clinical efficacy of 3D-printed metal augment or integrated acetabular prostheses for reconstruction of bone defects in hip revision.Methods:A total of 11 patients who underwent total hip revision in Zhengzhou Orthopaedic Hospital from June 2021 to July 2023 were retrospectively analysed. There were 5 males and 6 females, age 64.8±10.7 years (range, 58-75 years), and body mass index 23.3±4.8 kg/m 2 (range, 21-27 kg/m 2). Paprosky classification of acetabular bone defects: 3 cases of type IIA, 4 cases of type IIB, 3 cases of type IIIA, 1 case of type IIIB. Reasons for revision: 8 cases of aseptic loosening, 3 cases after infection exclusion procedure. A 3D-printed metal augment was used in 9 cases (8 cases of aseptic loosening and 1 case of infected exclusion procedure) and a 3D-printed integrated acetabulum was used in 2 cases (infected exclusion procedure). The time from primary total hip arthroplasty to revision was 11.8±5.6 years (range, 5-17 years). Harris hip score and visual analogue scale (VAS) were used to evaluate the improvement of hip function and pain recovery. The leg length discrepancy, vertical height and horizontal position of the hip rotation center were measured on pelvic anteroposterior X-ray films. Results:All patients successfully completed the operation. The operation time was 145.9±35.5 min (range, 110-159 min), and the intraoperative blood loss was 950.5±310.8 ml (range, 680-1,450 ml). The postoperative Harris hip function score was significantly higher than that before operation ( F=554.085, P<0.001). One year after operation, the Harris hip function score was 74.36±5.16, which was higher than that before operation 32.18±4.07, and the difference was statistically significant ( P<0.05). The VAS scores of all patients decreased after operation, and the difference was statistically significant compared with that before operation ( F=177.717, P<0.001). The VAS score at 1 year after operation was 1.27±0.65, which was lower than that before operation 6.18±1.17, and the difference was statistically significant ( P<0.05). The preoperative leg length discrepancy was 1.97±0.71 cm, which was greater than 0.69±0.52 cm at the last follow-up, and the difference was statistically significant ( t=4.824, P<0.001). The vertical height of the hip rotation center was 1.88±0.46 cm on the affected side and 1.67±0.35 cm on the healthy side, showing no significant difference ( t=1.205, P=0.242). The postoperative horizontal position of the hip rotation center was 3.48±0.55 cm on the affected side and 3.54±0.32 cm on the healthy side, and the difference was no statistically significant ( t=-0.313, P=0.758). One case had an intraoperative greater trochanteric fracture that healed 3 months after reduction and internal fixation. All patients were followed up for 21.3±9.5 months (range, 15-31 months). All incisions healed in one stage, and all patients were fully weight-bearing at 3 months after operation. At the last follow-up, there was no case of loosening, dislocation or infection of the prosthesis; 4 cases had mild claudication, 1 case had heterotopic ossification, and the patients had good hip flexion and extension functions, which did not affect daily life without further treatment. Conclusion:The clinical efficacy of 3D-printed metal augment or integrated acetabular prosthesis for reconstruction of acetabular bone defects is satisfactory, which can restore the normal center of rotation of the hip joint and has a low incidence of postoperative complications.
9.Comparative efficacy of hip hemiarthroplasty via the fracture line approach versus modified Harding approach in the treatment of unstable intertrochanteric fractures in the elderly
Bo SUN ; Kewei LI ; Shaohua WANG ; Aiguo WANG ; Wei MEI ; Jinliang WANG
Chinese Journal of Trauma 2025;41(8):746-753
Objective:To compare the efficacy of hip hemiarthroplasty via the fracture line approach versus modified Harding approach in the treatment of unstable intertrochanteric fractures in the elderly.Methods:A retrospective cohort study was conducted to analyze the clinical data of 79 elderly patients with unstable intertrochanteric fractures who were admitted to Zhengzhou Orthopaedic Hospital between July 2018 and February 2024, including 17 males and 62 females, aged 80-96 years [(84.0±9.6)years]. According to the AO classification, the fractures were classified as type A2 in 61 patients and type A3 in 18. All the patients underwent hip hemiarthroplasty, 33 of whom were treated via the fracture line approach (fracture line approach group) and 46 via the modified Harding approach (modified Harding approach group). The incision length, operation duration, intraoperative blood loss, blood transfusion volume, and weight-bearing time were documented. At 1 month, 3 months after surgery and at the last follow-up, hip function and pain were assessed using the Harris hip score and visual analogue scale (VAS). Postoperative dislocation rate, fracture nonunion rate, incidence of other complications (vascular injury, neurologic impairment, prosthesis loosening, lower extremity venous thrombosis, and surgical site infection) and 12-month mortality rate were recorded.Results:All the patients were followed up for 12-36 months [(18.0±5.1)months]. The operation duration and intraoperative blood loss were (68.2±8.4)minutes and (286.6±63.7)ml in the fracture line approach group, which were significantly shorter or less than (72.4±6.7)minutes and (321.3±76.2)ml in the modified Harding approach group ( P<0.05). However, there were no statistically significant differences in the incision length, blood transfusion volume or weight-bearing time between the two groups ( P>0.05). Harris hip scores and VAS scores at 1 month, 3 months, and at the last follow-up showed no significant differences between the two groups ( P>0.05). The dislocation rate was 0 in the fracture line approach group, superior to 13% in the modified Harding approach group ( P<0.05). There were no statistically significant differences in the fracture nonunion rate, incidence of other complications, or 12-month mortality rate between the two groups ( P>0.05). Conclusion:Compared with the modified Harding approach, hip hemiarthroplasty via the fracture line approach in the treatment of unstable intertrochanteric fractures in the elderly can shorten the operation time, reduce intraoperative blood loss, and lower the postoperative dislocation rate.
10.Research on surgical treatment strategies for Mason type III radial head fracture complicated with adult Bado type II Monteggia fracture
Dawei ZHANG ; Honghao CHEN ; Kun WANG ; Jiangming QI ; Yugang PAN ; Shijun ZHENG ; Aiguo WANG ; Yejun ZHA ; Maoqi GONG ; Dongsheng LI
Chinese Journal of Orthopaedics 2025;45(13):848-855
Objective:To explore the surgical treatment strategies for Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures.Methods:A retrospective analysis was performed on the clinical data of 25 adult patients with Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures, admitted to the Upper Extremity Orthopaedics Department of Zhengzhou Orthopaedic Hospital from June 2013 to June 2023. There were 15 males and 10 females, with an average age of 43.5±14.7 years (range: 20-67 years). Among them, 5 cases were complicated with humeroulnar joint dislocation. The patients were divided into two groups: 17 cases were treated with open reduction and internal fixation (ORIF) of radial head fractures combined with ORIF of proximal ulnar fractures (open reduction group), and 8 cases were treated with radial head replacement combined with ORIF of proximal ulnar fractures (radial head replacement group). At the last follow-up, elbow joint range of motion was recorded, and pain, elbow function, and subjective upper limb function were evaluated using the Visual Analogue Scale (VAS), Mayo Elbow Performance Score (MEPS), and Disabilities of the Arm, Shoulder and Hand (DASH) scale. The incidence of complications was also recorded.Results:All 25 patients were followed up for an average of 25.6±9.0 months (range: 12-45 months). At the last follow-up, the affected elbows in the open reduction group had a flexion of 124.47°±12.59° (range, 90°-140°), extension of 21.12°±10.07° (range, 10°-50°), pronation of 48.59°±11.62° (range, 20°-61°), and supination of 48.53°±8.43° (range, 30°-60°). In the radial head replacement group, the affected elbows showed flexion of 128.75°±13.17° (range, 100°-140°), extension of 14.00°±7.71° (range, 0°-25°), pronation of 61.25°±10.26° (range, 60°-80°), and supination of 71.88°±10.33° (range, 60°-80°). The MEPS score in the open reduction group was 82(75, 85) points (range, 55-90 points), the VAS pain score was 1(1, 2) points (range, 0-3 points), and the DASH score was 9(8, 14) points. In the radial head replacement group, the MEPS score was 90(85, 90) points (range, 85-90 points), the VAS pain score was 1(0, 1) points (range, 0-1 points), and the DASH score was 5(5, 6) points. Complications included 5 cases of heterotopic ossification, 1 case of incision infection, 1 case of nonunion, 1 case of ulnar nerve injury combined with traumatic arthritis, and 1 case of proximal radioulnar bone bridge formation.Conclusions:Both radial head replacement and open reduction internal fixation combined with proximal ulnar fracture fixation can effectively treat Mason type III radial head fractures complicated with adult Bado type II Monteggia fractures. There was no significant difference in postoperative flexion and extension, but the radial head replacement group demonstrated better forearm rotation and DASH scores postoperatively.

Result Analysis
Print
Save
E-mail