1.Lenthening and reconstruction progress of achondroplastic short arm deformity.
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):118-122
OBJECTIVE:
To describe the characteristics of short arm deformity in patients with achondroplasia, and summarize the progress of its lenthening and reconstruction, so as to provide reference for clinical diagnosis and treatment.
METHODS:
The literature on the lenthening of upper limb with achondroplastic short arm deformity at home and abroad in recent years was reviewed, and the characteristics, extension methods, postoperative management, effectiveness evaluation, and related complications of short arm deformity were summarized.
RESULTS:
Achondroplastic short arm deformity affect the patient's daily perineal hygiene activities. Although the upper limb is proportionately shortened, the humerus is mainly short limb deformity. Bilateral humeral lengthening is a common treatment method, and the traditional lengthening tools are mainly external fixation, guided by Ilizarov distraction osteogenesis concept; intramedullary lengthening is the latest treatment method. Lengthening percentage and healing index are commonly used for clinical evaluation indexes, and complications such as nerve injury may occur during upper limb lengthening.
CONCLUSION
In addition to appearance improvement, achondroplastic short arm lengthening is of great significance in achieving self-management of individual perineal hygiene. Lenthening and reconstruction methods are constantly being innovated and improved.
Humans
;
Achondroplasia/surgery*
;
Osteogenesis, Distraction/methods*
;
Bone Lengthening/methods*
;
Plastic Surgery Procedures/methods*
;
Humerus/abnormalities*
;
Treatment Outcome
;
Ilizarov Technique
;
Arm/abnormalities*
2.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
3.Analysis of anatomical characteristics of proximal humerus measured based on three-dimensional reconstruction technique and its clinical significance.
Jun WANG ; Jun DENG ; Shuo LI ; Facan LI ; Yanlin LI ; Miao CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1296-1303
OBJECTIVE:
To conduct a comprehensive analysis of proximal humeral anatomical characteristics in the Chinese population utilizing three-dimensional reconstruction technology, thereby establishing an evidence base for the enhancement of shoulder hemiarthroplasty procedures and the development of domestically manufactured prostheses.
METHODS:
The study cohort comprised 30 patients (60 shoulders) presenting with cervicoscapular pain between July 2023 and June 2025, with equal gender distribution (15 males and 15 females); age distribution ranged from 20 to 75 years (mean, 53.7 years). Data acquisition was performed via high-resolution CT imaging (technical parameters: slice thickness 0.625 mm, voltage 120 kV, current 150 mA, matrix 512×512). Subsequently, CT datasets were processed in DICOM format using Mimics17.0 software for three-dimensional reconstruction, followed by quantitative assessment via Imageware12.0 software to evaluate key proximal humeral parameters: humeral head dimensions (coronal diameter, sagittal diameter, surface curvature diameter, thickness), angular measurements [neck-shaft angle, retroversion angle (retroversion angle 1 was the angle between the humeral head axis and the line connecting the medial and lateral condyles, and retroversion angle 2 was the angle between the humeral head axis and the tangent of the trochlea)], and positional metrics (medial offset, posterior offset). Statistical analysis incorporated Pearson correlation coefficients to determine parameter relationships, with comparative evaluations conducted across demographic variables including gender, height, body mass, and age.
RESULTS:
Quantitative analysis yielded the following measurements: humeral head coronal diameter (41.8±3.6) mm, sagittal diameter (39.1±4.1) mm, surface curvature diameter (44.9±4.6) mm, thickness (17.2±1.8) mm, neck-shaft angle (128.4±4.2)°, retroversion angle 1 (16.9±8.9)°, retroversion angle 2 (21.4±11.3)°, medial offset (3.8±1.7) mm, and posterior offset (5.1±1.6) mm. Correlation analysis demonstrated the most pronounced positive relationship between humeral head surface curvature diameter and thickness ( r=0.966, P=0.001), with additional significant positive correlations observed between surface curvature diameter and coronal diameter ( r=0.842, P=0.001), posterior offset and retroversion angle 1 ( r=0.766, P=0.001), and coronal diameter and thickness ( r=0.727, P=0.001). Demographic analysis revealed significantly greater dimensions in males compared to females for humeral head surface curvature diameter, coronal diameter, sagittal diameter, and thickness ( P<0.05), with these parameters demonstrating progressive increases corresponding to height ( P<0.05). With the exception of neck-shaft angle, all parameters exhibited a positive correlation with body mass. No significant age-related differences were detected across parameters ( P>0.05).
CONCLUSION
The proximal humeral morphology in the Chinese population exhibits substantial variability, necessitating optimization of prosthetic designs based on population-specific anatomical metrics to enhance the efficacy of personalized clinical interventions.
Humans
;
Middle Aged
;
Male
;
Female
;
Aged
;
Imaging, Three-Dimensional/methods*
;
Adult
;
Tomography, X-Ray Computed/methods*
;
Humerus/diagnostic imaging*
;
Shoulder Joint/surgery*
;
Hemiarthroplasty/methods*
;
Humeral Head/anatomy & histology*
;
Young Adult
;
Clinical Relevance
4.Finite element analysis of influence of humerus torque screw tip distance on stability of proximal humeral fracture plate fixation.
Chen ZHOU ; Cheng CHEN ; Rui CAO ; Hong-Wang GUO ; Chen-Yi HUANG ; Liang YAN ; Wei-Hua XUE
China Journal of Orthopaedics and Traumatology 2024;37(12):1202-1207
OBJECTIVE:
To explore changes of humerus torque screw tip distance on stability of proximal humeral internal locking system (PHILOS) by finite element analysis, in order to provide reference for selection of intraoperative plant size.
METHODS:
The proximal humerus 3D model was constructed based on Synbone artificial bone model in 3D engineering drawing software, and the corresponding 3D model was constructed based on PHILOS bone plate contour. The model was modified to simulate comminuted proximal humerus fracture, and the operation model was simulated after fracture, and the fixed operation model was assembled, the apex distance of humerus moment screw was set as 4, 8, 12 and 16 mm respectively. The axial and torsional loads were applied under the conditions of vertical downward and 20° abduction respectively, and the maximum displacement of humeral head and the peak stress of cortical bone and cancellous bone of humeral head were calculated under the corresponding working conditions, respectively, to evaluate influence of screw tip distance change on the risk of humeral head varus after PHILOS plate fixation.
RESULTS:
The peak displacement of humerus head did not generally increase with the increase of torque screw tip distance. On the contrary, the peak displacement of humerus head decreased slightly in all working conditions with the gradual increase of torque screw tip distance. At 20° abduction, the maximum displacement of humerus head was significantly higher in all models than that under vertical loading. At the same time, the lengthening of tip distance of torque screw did not lead to significant stress concentration of the humerus head after operation. The peak stress of cancellous bone decreased gradually with the extension of the peak distance of humerus moment screw, while the peak stress of cortical bone increased first and then decreased. When the peak distance was 12 mm, the peak stress of cortical bone was the largest under all working conditions, and then decreased with the further extension of the peak distance.
CONCLUSION
In the case of a small humeral head interlocking screw tip distance(less than 4 mm), increasing the humeral torque screw tip distance does not lead to a significant loss of stability after PHILOS plate fixation and a significant increase in the risk of postoperative complications.
Humans
;
Finite Element Analysis
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Bone Screws
;
Humerus/surgery*
;
Shoulder Fractures/surgery*
;
Torque
;
Biomechanical Phenomena
5.Comparative study on effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in treatment of Jakob type Ⅱ lateral condylar humerus fractures in children.
Xiwei SUN ; Hailong MA ; Fang LIU ; Zhiye GUAN ; Sicheng ZHANG ; Jun SUN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):952-957
OBJECTIVE:
To compare the effectiveness of ultrasound- and arthrography-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ lateral condylar humerus fracture (LCHF) in children.
METHODS:
A clinical data of 101 children with Jakob type Ⅱ LCHF, who met the selection criteria and were admitted between April 2021 and April 2022, was retrospectively analyzed. Of them, 47 cases were treated with ultrasound-assisted Kirschner wire fixation (group A), and 54 cases with arthrography-assisted surgery (group B). There was no significant difference in gender, age, cause of injury, fracture side, and disease duration between groups (P>0.05). Intraoperative fluoroscopy times, operation time, and hospital stay, Flynn elbow joint function score, and postoperative complications were recorded and compared between groups. X-ray examination was performed to observe the healing of fracture, and measure the carrying angle and the shaft-condylar angle (SCA).
RESULTS:
The success rate of closed reduction was significantly higher in group A than in group B (P<0.05), and the intraoperative fluoroscopy times was significantly less in group A than in group B (P<0.05). There was no significant difference in operation time and hospital stay between groups (P>0.05). All children in both groups were followed up 12-18 months, with an average of 13.6 months. X-ray reexamination showed that the fractures of both groups healed, and the difference in healing time was not significant (P>0.05). At last follow-up, there was no significant difference in carrying angle and SCA between unaffected side and affected side in both groups and between groups A and B in affected side (P>0.05). There was no significant difference in Flynn elbow joint function score between groups (P>0.05). There were 18 cases of lateral spurs formation in group A, 1 case of pinning infection and 26 cases of lateral spurs formation in group B, and there was no significant difference in the incidence of the above complications (P>0.05).
CONCLUSION
Compared with the arthrography, the ultrasound-assisted Kirschner wire fixation in the treatment of Jakob type Ⅱ LCHF in children can avoid the open reduction and decrease the number of intraoperative fluoroscopy, and obtain the good effectiveness.
Child
;
Humans
;
Arthrography
;
Bone Wires
;
Humeral Fractures/surgery*
;
Humerus
;
Retrospective Studies
;
Male
;
Female
6.Reconstruction of medial and lateral column periosteal hinge using Kirschner wire to assist in closed reduction of multi-directional unstable humeral supracondylar fractures in children.
Hailong MA ; Fang LIU ; Zhilin ZHOU ; Sicheng ZHANG ; Zhongtuo HUA ; Guoqiang JIA ; Jun SUN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1220-1224
OBJECTIVE:
To investigate the effectiveness of medial and lateral column periosteal hinge reconstruction using Kirschner wire in the closed reduction of multi-directional unstable humeral supracondylar fractures in children.
METHODS:
A clinical data of 43 children with multi-direction unstable humeral supracondylar fractures, who met the selection criteria and were admitted between August 2020 and August 2022, was retrospectively analyzed. Twenty-one cases of fractures were treated wuth closed reduction after medial and lateral column periosteal hinge reconstruction using Kirschner wire and percutaneous Kirschner wires fixation (study group), while 22 cases of fractures were treated by traditional closed reduction technique and percutaneous Kirschner wire fixation (control group). There was no significant difference in gender, age, cause of injury, fracture side, and interval from injury to operation between the two groups ( P>0.05). The operation time, intraoperative fluoroscopy times, the number of children who were changed to open reduction after closed reduction failure, fracture healing time, complications within 2 months after operation, and the Flynn score of elbow joint function at last follow-up were compared between the two groups.
RESULTS:
All the fractures in the study group were successfully closed reduction, and 4 cases in the control group were changed to open reduction and completed the operation, the difference between the two groups was significant ( P=0.040). The operation time and intraoperative fluoroscopy times of the study group were significantly less than those of the control group ( P<0.05). All children in both groups were followed up 6-18 months with an average of 9.0 months in the study group and 9.8 months in the control group. Imaging review showed that the fractures of both groups healed, and the difference in the healing time between the two groups was not significant ( P=0.373). According to Flynn score at last follow-up, the excellent and good rate of elbow joint function was 95.2% (20/21) in the study group and 86.4% (19/22) in the control group, with no significant difference ( P=0.317). There was no complication such as infection or irritation at the end of Kirchner wire within 2 months after operation.
CONCLUSION
For children with multi-directional unstable humeral supracondylar fractures, the use of Kirschner wires to reconstruct the medial and lateral column periosteal hinge to assist in closed reduction has the advantages of shortening operation time, reducing intraoperative fluoroscopy times, and effectively reducing the incidence of open reduction, and can achieve similar postoperative elbow joint function when compared with traditional closed reduction technique.
Humans
;
Child
;
Bone Wires
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Humeral Fractures/surgery*
;
Humerus/surgery*
;
Treatment Outcome
7.Preoperative estimation of humerus intramedullary nail length using clinical landmarks.
Atmananda S HEGDE ; Chethan B SHETTY ; Nitin JOSEPH ; Prajwal MANE ; Samarth THAKKAR
Chinese Journal of Traumatology 2023;26(5):256-260
PURPOSE:
Intramedullary interlocking nailing is one of the accepted methods of treating humerus diaphyseal fractures. Appropriate nail length and diameter are of paramount importance to achieve a stable fracture fixation. Estimating the nail length can be as challenging in certain cases as it is important. This study aims to provide an easy-to-use formula utilizing clinical measurements from contra lateral arm to accurately estimate humeral nail length.
METHODS:
This descriptive cross-sectional study was conducted at 3 tertiary care hospitals in Mangalore, India. Patients above the age of 18 years coming to the outpatient department with elbow, shoulder or arm complaints requiring radiological investigation from July 2021 to July 2022 were included. Patients with fractures or dislocations of upper limbs, malunited or non-united fractures of upper limbs, congenital or developmental deformities and patients with open growth plates were excluded. Patients' variables (like age and gender), radiological humerus length and contralateral arm clinical measurements were recorded. An independent samples t-test was used for univariate analysis, and linear regression analysis was done to estimate the desired nail length using the clinical measurement of the humerus (cm) in both genders separately. The significance level was set at p < 0.05.
RESULTS:
Our study included 204 participants of which 108 were male and 96 were female. The formula for predicting humeral nail length in males is (-2.029) + (0.883 × clinical measurement). The formula for females is 1.862 + (0.741 × clinical measurement). A simplified formula to determine humeral nail length is 0.9 clinical length - 2 cm (in males) and 0.7 × clinical length + 2 cm (in females).
CONCLUSION
To improve the stability of fixation with intramedullary nails it is imperative to select the appropriate nail length. There have been studies that devised reliable methods of determining nail lengths in the tibia and femur using preoperative clinical measurements. A similar clinical method of determining humeral nail length is lacking in the literature. Our study was able to correlate radiological lengths of the humerus medullary canal with clinical measurements performed using anatomical landmarks to arrive at a formula. This allows for a reliable and easy nail length determination preoperatively.
Humans
;
Male
;
Female
;
Adolescent
;
Cross-Sectional Studies
;
Bone Nails
;
Humerus/surgery*
;
Fracture Fixation, Intramedullary/methods*
;
Humeral Fractures/surgery*
;
Treatment Outcome
8.Short-term effectiveness of transverse antecubital incision for failed closed reduction of Gartland type Ⅲ supracondylar humerus fractures in children.
Yinshuan DENG ; Jing BAI ; Rui LIU ; Zhaoming DA ; Weishun YAN ; Zhen CHEN ; Shuo LI ; Tao QU ; Weimin NIU ; Binbin GUO ; Zhiyun YANG ; Guohai LI ; Guoxin NAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):566-571
OBJECTIVE:
To investigate the short-term effectiveness of transverse antecubital incision in the treatment of failed closed reduction of Gartland type Ⅲ supracondylar humeral fractures (SHFs) in children.
METHODS:
Between July 2020 and April 2022, 20 children with Gartland type Ⅲ SHFs who failed in closed reduction were treated with internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision. There were 9 boys and 11 girls with an average age of 3.1 years (range, 1.1-6.0 years). The causes of injuries were fall in 12 cases and fall from height in 8 cases. The time from admission to operation ranged from 7 to 18 hours, with an average of 12.4 hours. The healing of the incision and the occurrence of complications such as nerve injury and cubitus varus were observed after operation; the elbow flexion and extension range of motion after removing the gypsum, after removing the Kirschner wire, and at last follow-up were recorded and compared, as well as the elbow flexion and extension and forearm rotation range of motion at last follow-up between healthy and affected sides; the Baumann angle was measured on the X-ray film, and the fracture healing was observed. At last follow-up, the effectiveness was evaluated according to the Flynn elbow function evaluation criteria.
RESULTS:
All incisions healed by first intention, and there was no skin necrosis, scar contracture, ulnar nerve injury, and cubitus varus. Postoperative pain occurred in the radial-dorsal thumb in 2 cases. The gypsum was removed and elbow flexion and extension exercises were started at 2-4 weeks (mean, 2.7 weeks) after operation, and the Kirschner wire was removed at 4-5 weeks (mean, 4.3 weeks). All the 20 patients were followed up 6-16 months, with an average of 12.4 months. The fracture healing time was 4-5 weeks, with an average of 4.5 weeks, and there was no complication such as delayed healing and myositis ossificans. The flexion and extension range of motion of the elbow joint gradually improved after operation, and there were significant differences between the time after removing the gypsum, after removing the Kirschner wire, and at last follow-up ( P<0.017). There was no significant difference in the flexion and extension of the elbow joint and the forearm rotation range of motion between the healthy and affected sides at last follow-up ( P>0.05). There was no significant difference in Baumann angle between the time of immediate after operation, after removing the Kirschner wire, and at last follow-up ( P>0.05). According to Flynn elbow function evaluation standard, 16 cases were excellent and 4 cases were good, the excellent and good rate was 100%.
CONCLUSION
The treatment of Gartland type Ⅲ SHFs in children with failed closed reduction by internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision has the advantages of complete soft tissue hinge behind the fracture for easy reduction and wire fixation, small incision, less complications, fast fracture healing, early functional recovery, reliable reduction and fixation, and can obtain satisfactory results.
Male
;
Female
;
Humans
;
Child
;
Child, Preschool
;
Calcium Sulfate
;
Humerus
;
Humeral Fractures/surgery*
;
Plastic Surgery Procedures
;
Fracture Fixation, Internal/methods*
;
Bone Wires
;
Fracture Healing
;
Treatment Outcome
;
Range of Motion, Articular
9.Clinical outcomes of reverse shoulder arthroplasty for the treatment of failed fixation of proximal humeral fracrtures in the elderly patients.
Wei-Bin DU ; Yi DONG ; Fu-Xiang SHEN ; Rong-Liang CHEN ; Shang-Ju XIE ; Keng YU ; Guo-Ping CAO
China Journal of Orthopaedics and Traumatology 2023;36(2):110-115
OBJECTIVE:
To evaluate the clinical outcomes of reverse total shoulder arthroplasty as a revision procedure for the failed fixation of proximal humeral fractures in the elderly patients.
METHODS:
A retrospective analysis was performed on 8 patients with failed internal fixation of proximal humeral fractures from May 2014 to March 2020, including 3 males and 5 females, aged from 65 to 75 years old. All 8 patients underwent reverse total shoulder arthroplasty, and the mean time between initial fixation and reverse total shoulder arthroplasty ranged from 8 to 16 months. Range of motion(ROM), University of California at Los Angeles(UCLA) shoulder score, visual analogue scale (VAS), self-rating anxiety scale(SAS), and Constant-Murley score of shoulder function were assessed pre-operatively and at the last follow-up. Complications relating to the surgery were recorded.
RESULTS:
All 8 patients successfully followed up. The mean follow-up after reverse total shoulder arhroplasty ranged from 16 to 28 months. The range of motion (forward flexion, external rotation, abduction and internal rotation) of the affected shoulder was significantly improved after surgery, and the post-operative VAS, SAS and UCLA scores were also significantly improved. For the Constant-Murley score of shoulder joint function, the total scores and the subscores of pain, daily activities, range of motion and strength test at the last follow-up were all significantly improved. Scapular glenoid notch was observed in patient, which was evaluated as grade 1 on imaging. All the other patients did not develop specific or non-specific complications.
CONCLUSION
Reverse total shoulder arhroplasty is an appropriate treatment as a revision surgery for failed fixation of proximal humeral fractures. It has shown satisfactory clinical outcomes, accelerating the rehabilitation of shoulder function and improving the quality of life.
Male
;
Female
;
Humans
;
Aged
;
Shoulder/surgery*
;
Arthroplasty, Replacement, Shoulder/methods*
;
Retrospective Studies
;
Treatment Outcome
;
Quality of Life
;
Shoulder Joint/surgery*
;
Shoulder Fractures/surgery*
;
Humerus/surgery*
;
Range of Motion, Articular
10.Treatment of four-part proximal humerus fractures with depressed humeral head collapse using strut allograft with locking plates.
Lie LIU ; Feng YANG ; Cheng-Cheng ZONG ; Jing CHEN
China Journal of Orthopaedics and Traumatology 2023;36(2):116-119
OBJECTIVE:
To evaluate the clinical outcomes of allogeneic femoral head as strut allograft combined with proximal humeral internal locking system (PHILOS) in the treatment of proximal humeral Neer grade Ⅳ fracture with humeral head collapse.
METHODS:
From January 2018 to November 2020, 18 patients with Neer grade Ⅳ fracture with humeral head collapse were treated with strut allograft with PHILOS, including 4 males and 14 females, aged from 55 to 78 years old, with an average of (68.11±7.20) years old. The operation time, intraoperative bleeding, postoperative drainage volume, fracture healing time, neck-shaft angle and the height of the humeral head, failure of internal fixation the shoulder function at the last follow-up was assessed using Neer's scoring system.
RESULTS:
All 18 patients were followed up, and the duration ranged from 10 to 12 months, with an average of (11.08±0.65) months. The operation time was (66.44±5.06) min, the intraoperative bleeding volume was (206.67±36.14) ml, the postoperative drainage volume was (76.11±9.63) ml, and the fracture healing time was (17.28±3.92) weeks. At the last follow-up, the degree of loss of neck-shaft angle was (5.44±0.86) ° and the loss of the height of humeral head was (1.43±0.27) mm. All 18 patients had healing without complications such as fracture, withdrawal, penetration of internal fixation and necrosis of humeral head. According to Neer's evaluation standard, the total score was (89.61±5.60), 10 cases got an excellent result, 6 good, 2 fair.
CONCLUSION
Allogeneic femoral head combined with PHILOS is an appropriate treatment for the four-part proximal humerus fractures with humeral head collapse, exhibiting good clinic outcome.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Humeral Head
;
Shoulder
;
Treatment Outcome
;
Bone Plates
;
Retrospective Studies
;
Humerus
;
Shoulder Fractures/surgery*
;
Fracture Fixation, Internal/adverse effects*
;
Humeral Fractures
;
Allografts

Result Analysis
Print
Save
E-mail