1.Postoperative urinary retention following hip or knee arthroplasty under spinal anaesthesia with intrathecal morphine: a retrospective cohort study.
Elad DANA ; Oz BEN-ZUR ; Sara DICHTWALD ; Guy FEIGIN ; Noa BRIN ; Michael MARKUSHEVICH ; Brian FREDMAN ; Yaron Shraga BRIN
Singapore medical journal 2025;66(9):481-485
INTRODUCTION:
Postoperative urinary retention (POUR) frequently complicates the course of patients following hip and knee arthroplasty. Intrathecal morphine (ITM) was identified as a significant risk factor for POUR. The objective of this study was to investigate the incidence and risk factors for POUR in fast-track total joint arthroplasty (TJA) under spinal anaesthesia (SA) with ITM.
METHODS:
We conducted a retrospective study of our institutional joint registry of patients who underwent primary TJA under SA with ITM between October 2017 and May 2021. Preoperative (baseline demographics) and perioperative data were collected. The primary outcome was the incidence of POUR after 8 h or earlier, either due to lack of voiding or according to patient's complaints of bladder distension. Univariate and adjusted analyses were performed to identify predictors of POUR.
RESULTS:
Sixty-nine patients who underwent total knee arthroplasty (TKA) and 36 patients who underwent total hip arthroplasty (THA) under SA with ITM were included in the study. POUR requiring bladder catheterisation was diagnosed in 21% of patients. Independent predictors of POUR were age over 65 years and male gender.
CONCLUSIONS
SA with ITM for TJA is associated with high rates of POUR in males older than 65 years of age. Other previously identified risk factors such as intraoperative fluid administration or comorbidities may not be as influential.
Humans
;
Retrospective Studies
;
Male
;
Urinary Retention/epidemiology*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Anesthesia, Spinal/adverse effects*
;
Female
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Morphine/adverse effects*
;
Aged
;
Middle Aged
;
Risk Factors
;
Postoperative Complications/epidemiology*
;
Injections, Spinal
;
Incidence
;
Analgesics, Opioid/adverse effects*
;
Aged, 80 and over
2.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
3.Application of personalized three-dimensional printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Shuailei LI ; Hao CHAI ; Yongqiang SUN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):13-19
OBJECTIVE:
To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
METHODS:
A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film.
RESULTS:
The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation ( t=-12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the "Lewinneck safety zone". There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side ( P>0.05).
CONCLUSION
The use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
Humans
;
Printing, Three-Dimensional
;
Male
;
Female
;
Middle Aged
;
Acetabulum/surgery*
;
Aged
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Reoperation
;
Treatment Outcome
4.Analysis of correlation between Barthel index score and preoperative occurrence of deep vein thrombosis in patients undergoing total hip arthroplasty revision surgery.
Ying SHEN ; Yao YAO ; Liang QIAO ; Dengxian WU ; Xinhua LI ; Qing JIANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):158-162
OBJECTIVE:
To explore the correlation between the Barthel index score and other factors with the preoperative occurrence of deep vein thrombosis (DVT) in patients undergoing total hip arthroplasty (THA) revision surgery.
METHODS:
A retrospective analysis was conducted on clinical data from 122 patients who met the inclusion criteria and underwent THA revision surgery between April 2017 and November 2020. Among them, 61 were male and 61 were female, with an age range of 32-85 years (mean, 65.3 years). The reasons for revision included prosthetic joint infection in 7 cases, periprosthetic fracture in 4 cases, prosthetic dislocation in 6 cases, and aseptic loosening in 105 cases. The Barthel index score was 76.4±17.7, with 10 cases classified as level 1, 57 as level 2, 37 as level 3, and 18 as level 4. Univariate analysis was performed on variables such as age, gender, body mass index, Barthel index score, preoperative D-dimer positivity, history of diabetes, hypertension, cancer, cerebral infarction, smoking, and thrombosis in patients with and without preoperative DVT. Furthermore, logistic regression was used to identify risk factors for preoperative DVT in THA revision surgery. The incidence of preoperative DVT was compared among different Barthel index score groups.
RESULTS:
Preoperative DVT was detected in 11 patients (9.02%), all of whom had intermuscular venous thrombosis. Among them, 1 had prosthetic joint infection, 1 had periprosthetic fracture, 1 had prosthetic dislocation, and 8 had aseptic loosening. Univariate analysis showed significant differences between the two groups in terms of age, gender, and Barthel index score ( P<0.05). logistic regression further revealed that female, age ≥70 years, and Barthel index score<60 were independent risk factors for preoperative DVT in patients undergoing THA revision surgery ( P<0.05). The incidence of preoperative DVT in patients with Barthel index scores of levels 1, 2, 3, and 4 were 0 case (0%), 2 cases (3.5%), 3 cases (8.1%), and 6 cases (33.3%), respectively. A significant correlation was found between Barthel index score classification and the incidence of preoperative DVT in patients undergoing THA revision surgery ( χ 2=10.843, P=0.001).
CONCLUSION
In patients undergoing THA revision surgery, older age, female, and lower Barthel index scores are associated with higher preoperative DVT incidence. For patients with low preoperative Barthel index scores, preoperative thrombosis screening should be emphasized.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Reoperation
;
Aged, 80 and over
;
Venous Thrombosis/epidemiology*
;
Adult
;
Risk Factors
;
Postoperative Complications/etiology*
;
Preoperative Period
5.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
6.Research progress in etiology and prevention of bone cement implantation syndrome.
Guangtao HAN ; Qin WANG ; Shuo SUN ; Pengde KANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):237-242
OBJECTIVE:
To introduce the etiology and prevention of bone cement implantation syndrome (BCIS).
METHODS:
The literature about BCIS at home and abroad in recent years was extensively reviewed, and the incidence, clinical manifestations, etiology, and prevention of BCIS were summarized and analyzed.
RESULTS:
The clinical manifestations of BCIS are diverse. The etiology of BCIS is not completely clarified, and it may be related to circulating methyl methacrylate-mediated model, embolus-mediated model, histamine release and hypersensitivity response, complement activation and multimodal model. BCIS prevention begins with the identification of high-risk patients in preoperative evaluation and communication between surgeon and anesthesiologist about the choice of implant type, surgical procedure, and technique to minimize the risk of cardiovascular complications in high-risk patients with multiple or severe risk factors or comorbidities. Preoperative assessment and optimization of a patient's cardiovascular reserve is also critical to prevent BCIS.
CONCLUSION
BCIS is a possible complication after hip joint arthroplasty, and its pathogenesis needs to be further research in order to provide new ideas for prevention and treatment.
Humans
;
Bone Cements/adverse effects*
;
Postoperative Complications/etiology*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Risk Factors
;
Syndrome
;
Methylmethacrylate/adverse effects*
7.Analgesic effect of "cocktail" analgesia containing high-dose compound betamethasone after revision hip arthroplasty and the use of opioid drugs.
Ning YANG ; Wulamu WUHUZI ; Xiaobin GUO ; Yicheng LI ; Xiaogang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):314-319
OBJECTIVE:
To investigate the analgesic effect of locally injecting a "cocktail" analgesia containing a high-dose compound betamethasone during revision hip arthroplasty, and also to study the usage of opioid drugs.
METHODS:
A retrospective analysis was conducted on the clinical data of 180 patients who underwent revision hip arthroplasty due to aseptic loosening of the hip prosthesis between January 2015 and December 2021. Among them, 95 patients received intraoperative injection of "cocktail" analgesia containing high-dose compound betamethasone (group A), and 85 patients received intraoperative injection of traditional "cocktail" analgesia (group B). There was no significant difference in baseline data such as gender, age, body mass index, presence or absence of diabetes mellitus between the two groups ( P>0.05). The hospital stay, use of opioid drugs within 72 hours, and the incidence of adverse reactions within 72 hours after operation [including nausea and vomiting, insomnia, deep venous thrombosis (DVT), infection, etc.] were recorded and compared between the two groups. The pain relief of patients was evaluated using the static and dynamic visual analogue scale (VAS) scores at 12, 24, 48, and 72 hours after operation. The incidence of complications (including prosthesis re-loosening, hip joint dislocation, hip joint stiffness, limping, chronic pain, etc.) at 2 years after operation was recorded, and the Harris Hip Score (HHS) was used to evaluate the function at 2 years after operation.
RESULTS:
In group A, the utilization rate of opioid drugs within 72 hours after operation was significantly lower than that in group B ( P<0.05). However, there was no significant difference between the two groups in terms of hospital stay, as well as the incidence of adverse reactions such as nausea and vomiting, insomnia, DVT, and infection within 72 hours after operation ( P>0.05). The VAS scores of both groups decreased with time, and the differences between different time points were significant ( P<0.05). The static and dynamic VAS scores of group A were significantly lower than those of group B at 12, 24, and 48 hours after operation ( P<0.05), but there was no significant difference in static and dynamic VAS scores between the two groups at 72 hours after operation ( P>0.05). All patients in both groups were followed up 2-8 years, with an average of 5.73 years. At 2 years after operation, no significant difference was found between the two groups in the incidence of complications and HHS score ( P>0.05).
CONCLUSION
"Cocktail" analgesia containing a high-dose compound betamethasone for early analgesia after revision hip arthroplasty can effectively reduce postoperative pain and the use of opioid drugs, but will not increase the incidence of infection and DVT after operation.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Betamethasone/therapeutic use*
;
Retrospective Studies
;
Male
;
Female
;
Analgesics, Opioid/administration & dosage*
;
Pain, Postoperative/prevention & control*
;
Middle Aged
;
Reoperation
;
Aged
;
Analgesia/methods*
;
Adult
;
Pain Measurement
;
Pain Management/methods*
;
Prosthesis Failure
;
Hip Prosthesis
8.Research progress in application of intelligent remote follow-up mode in hip and knee arthroplasty.
Yunhao TANG ; Xin WANG ; Wei CHAI ; Fangyuan YU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):375-383
OBJECTIVE:
To review the research progress of intelligent remote follow-up modes in the application after hip and knee arthroplasty.
METHODS:
Extensive literature on this topic published in recent years both domestically and internationally was reviewed, and the application of intelligent remote follow-up modes after hip and knee arthroplasty was summarized and analyzed.
RESULTS:
The intelligent remote follow-up mode is a novel follow-up method based on network information technology. Patients who undergo hip and knee arthroplasty require long-term follow-up and rehabilitation guidance after operation. Traditional outpatient follow-up is relatively time-consuming and inconvenient for some patients in terms of travel and transportation, which makes the application of intelligent remote follow-up modes increasingly widespread worldwide. The inherent attributes of remote interaction and instant feedback of this mode make it particularly valued in the field of hip and knee arthroplasty. Artificial intelligence (AI)-based voice follow-up systems and virtual clinics have significant advantages in improving follow-up efficiency, reducing human resource costs, and enhancing patient satisfaction.
CONCLUSION
The existing intelligent follow-up system has formed a standardized protocol in remote follow-up and rehabilitation guidance. However, there are still shortcomings in the formulation of personalized rehabilitation plans and the gerontechnological adaptation of human-computer interaction. In the future, it is necessary to construct a multimodal data fusion platform and establish technical application guidelines for different rehabilitation stages.
Humans
;
Arthroplasty, Replacement, Knee/rehabilitation*
;
Arthroplasty, Replacement, Hip/rehabilitation*
;
Artificial Intelligence
;
Follow-Up Studies
;
Telemedicine
9.Feasibility study on measuring anteversion angle of acetabular prosthesis after total hip arthroplasty using arbitrary point method.
Bowen LI ; Longyuan LI ; Heng ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):420-424
OBJECTIVE:
To explore the reliability and accuracy of the arbitrary point method for measuring the anteversion angle of acetabular prosthesis after total hip arthroplasty (THA) based on pelvic X-ray films.
METHODS:
The clinical data of 23 patients (25 hips) who underwent THA between December 2018 and September 2023 and met the selection criteria were retrospectively analyzed. Among them, there were 16 males and 7 females, with an average age of 57.6 years (range, 34-81 years); 13 hips had THA on the left side and 12 on the right side. There were 19 cases (21 hips) of osteonecrosis of the femoral head, 2 cases (2 hips) of femoral neck fractures, 1 case (1 hip) of developmental dysplasia of the hip, and 1 case (1 hip) of osteoarthritis. After THA, all patients underwent X-ray examination and CT scan. Three physicians measured the anteversion angle of acetabular prosthesis using the arbitrary point method and the CT measurement method respectively, and repeated the measurements three times. The results of the two measurement methods were compared, and the intraclass correlation coefficient (ICC) was employed to assess the reproducibility of the methods.
RESULTS:
The anteversion angles of acetabular prosthesis were (15.87±7.73)° measured by the arbitrary point method, and (15.31±7.89)° measured by CT measurement method. There was no significant difference between the two methods ( t=1.515, P=0.143). The ICC of the measurement results by the arbitrary point method for the three physicians were 0.97 ( P<0.001), 0.96 ( P<0.001), and 0.96 ( P<0.001), respectively; and the ICC of the measurement results by CT method were 0.93 ( P<0.001), 0.93 ( P<0.001), and 0.94 ( P<0.001), respectively.
CONCLUSION
The arbitrary point method for measuring the anteversion angle of acetabular prosthesis after THA based on pelvic X-ray film is easy to operate, accurate, and has high reproducibility.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Hip Prosthesis
;
Acetabulum/surgery*
;
Aged, 80 and over
;
Retrospective Studies
;
Adult
;
Reproducibility of Results
;
Feasibility Studies
;
Tomography, X-Ray Computed
10.Comparison of muscle injury between piriformis muscle release and preservation in total hip arthroplasty via supercapsular percutaneously-assisted total hip approach.
Fengping GAN ; Qibiao ZHANG ; Fulai MO ; Linjie LI ; Fei ZHENG ; Xinxin LIN ; Hao QIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):715-722
OBJECTIVE:
To compare the effects of piriformis muscle release versus preservation in total hip arthroplasty (THA) via supercapsular percutaneously-assisted total hip (SuperPATH) approach on muscle injury.
METHODS:
Forty-nine patients undergoing initial THA via SuperPATH approach between June 2022 and June 2023 were randomly divided into two groups, with 24 patients in trial group and 25 patients in control group. The trial group received piriformis muscle release intraoperatively, whereas the control group underwent muscle preservation. There was no significant difference in baseline data such as gender, age, body mass index, disease type, American Society of Anesthesiologists (ASA) grading, and preoperative muscle infiltration, muscle atrophy, muscle injury serological indicators, Harris score, etc. ( P>0.05). The incision length, operation time, intraoperative blood loss, total blood loss, hospital stay, preoperative and postoperative 1-day muscle injury serological indicators [including creatine kinase (CK) and lactic dehydrogenase (LDH)], and incidence of complications between two groups were recorded. Harris score was used to evaluate the recovery of hip joint function. MRI was used to evaluate the extent of hip muscle injuries (gluteus minimus, gluteus medius, piriformis, obturator internus, quadratus femoris), including tendon integrity, degree of muscle fat infiltration, and degree of muscle atrophy preoperative and 1 year postoperatively.
RESULTS:
The operation time, intraoperative blood loss, and total blood loss in the trial group were significantly shorter than those in the control group ( P<0.05). There was no significant difference in the incision length and length of hospital stay between the two groups ( P>0.05). Both groups showed a significant increase in serum CK and LDH levels on postoperative day 1 compared to preoperative levels ( P<0.05), but there was no significant difference between the two groups ( P>0.05). All patients were followed up, the follow-up time for the trial group and the control group was (14.8±2.8) and (15.1±3.0) months, respectively, with no significant difference ( t=-0.400, P=0.691). Incisions healed by first intention in both groups, with 1 case in the trial group and 2 cases in the control group experiencing venous thrombosis in the calf muscle space. There was no complication such as deep vein thrombosis, pulmonary embolism, hip dislocation, prosthesis loosening, or periprosthetic infection in the lower limbs. There was no significant difference in the incidence of complications between the two groups ( P>0.05). At 1 year after operation, both groups of patients showed a significant increase in Harris scores compared to preoperative levels ( P<0.05), but there was no significant difference between the two groups ( P>0.05). Compared with preoperative results, both groups showed significant fat infiltration in the piriformis and obturator muscles at 1 year after operation ( P<0.05), while there was no significant fat infiltration in the gluteus minimus, gluteus medius, and quadratus femoris muscles ( P>0.05). At 1 year after operation, except for the higher incidence of piriformis muscle fat infiltration in the control group compared to the trial group ( P<0.05), there was no significant difference in the incidence of other muscle infiltrations between the two groups ( P>0.05). At 1 year after operation, both groups of piriformis and obturator muscles showed significant muscle atrophy compared to preoperative levels ( P<0.05). The gluteus minimus and gluteus medius showed mild atrophy compared to preoperative levels, while the maximum transverse diameter of the quadriceps muscle slightly increased, but the differences were not significant ( P>0.05). There was no significant difference in the maximum cross-sectional diameter or cross-sectional area changes of each muscle between the two groups ( P>0.05). At 1 year after operation, the continuity of the gluteus medius and quadratus femoris muscles in both groups was intact. Both groups had some patients with incomplete continuity of the piriformis muscle, obturator internus, and gluteus minimus, but the difference was not significant ( P>0.05).
CONCLUSION
The SuperPATH approach THA may cause injury to the piriformis, gluteus minimus, and obturator internus. The piriformis muscle release does not increase muscle injury, but it can shorten the operation time and reduce bleeding.
Humans
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Male
;
Female
;
Muscle, Skeletal/surgery*
;
Middle Aged
;
Aged
;
Postoperative Complications/epidemiology*
;
Adult
;
Operative Time
;
Muscular Atrophy
;
Creatine Kinase/blood*
;
Length of Stay
;
Treatment Outcome

Result Analysis