1.Effectiveness of comprehensive rhinoplasty on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Ming CHEN ; Zongke GUO ; Bing YU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):56-61
OBJECTIVE:
To investigate the effectiveness of comprehensive rhinoplasty with autogenous costal cartilage grafting and prosthesis augmentation rhinoplasty in the treatment of secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
METHODS:
The clinical data of 96 patients with secondary nasal deformity with saddle nasal deformity after cleft lip surgery between September 2008 and January 2019 were retrospectively analyzed. There were 17 males and 79 females with an average age of 25.6 years (range, 17-38 years). Autogenous costal cartilage grafts were used to construct stable nasal tip framework and enhance the strength of alar cartilage. Nasal dorsum prostheses (39 cases of bulge, 45 cases of silicone prosthesis) or autogenous costal cartilage (12 cases) were used for comprehensive rhinoplasty. Visual analogue scale (VAS) score was used to evaluate the postoperative satisfaction subjectively, and nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle were calculated to evaluate objectively before and after operation.
RESULTS:
All patients were followed up 6 months to 8 years, with an average of 13.4 months. Nasal septal hematoma occurred in 3 patients after operation, which was improved after local aspiration and nasal pressure packing. Two cases had mild deformation of the rib cartilage graft of the nasal dorsum, one of which had no obvious deviation of the nasal dorsum and was not given special treatment, and one case underwent the cartilage graft of the nasal dorsum removed and replaced with silicone prosthesis. The incisions of the other patients healed by first intention, and there was no complication such as postoperative infection and prosthesis displacement. The nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle significantly improved after operation when compared with preoperative ones ( P<0.05). Postoperative subjective satisfaction evaluation reached the level of basic satisfaction or above, and most of them were very satisfied.
CONCLUSION
Comprehensive rhinoplasty using autologous rib cartilage grafting to construct a stable nasal tip support, combined with dorsal nasal prosthesis or autologous cartilage implantation, can achieve good effectiveness on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Male
;
Female
;
Humans
;
Adult
;
Rhinoplasty
;
Cleft Lip/surgery*
;
Retrospective Studies
;
Nose/surgery*
;
Nasal Septum/surgery*
;
Nasal Cartilages/surgery*
;
Silicones
;
Treatment Outcome
2.A randomized controlled trial of iRoot BP Plus used as pulp capping agent in the complex fracture of young permanent tooth.
Yingting YANG ; Ruozhu LI ; Guili DOU ; Yue LEI ; Bin XIA
Journal of Peking University(Health Sciences) 2024;56(6):1083-1088
OBJECTIVE:
To investigate the clinical and radiographic outcomes of 3 years after partial pulpotomy with iRoot BP Plus in immature permanent teeth with complex crown fracture and to provide refe-rence for the clinical application.
METHODS:
The study was prospectively designed and 104 immature permanent teeth with complex crown fracture were randomly allocated into two groups (n=52). The experiment group received iRoot BP Plus as the pulp capping agent while the control group received calcium hydroxide as the pulp capping agent. After partial pulpotomy, all teeth were clinically and radiographically assessed at the end of 1, 3, 6, 12, 18, 24, 30, and 36 months. The success rate in the two groups was evaluated to see if there was significant difference. The root canal wall thickness in the treated teeth was compared both between the groups and within the groups with those of the corresponding healthy teeth on the opposite side, in the same patient.
RESULTS:
Excluding those lost to follow-up, there were 44 teeth in calcium hydroxide group (8 teeth accounting for 15.4% were lost to follow up) and 45 teeth in iRoot BP Plus group (7 teeth accounting for 13.5% were lost to follow up) in the end. There was no intergroup difference in the success rate between calcium hydroxide group and iRoot BP Plus group (per-protocol analysis: 80% vs. 87%; intent-to-treat analysis: 67% vs. 75%). The non-inferiority margin was -10%. The 95% confidence interval of the difference in success rate was -8% to 22%. There was no significant difference in root development between the experimental teeth and contralateral control teeth. The thickness of upper 1/3 root canal in the iRoot BP Plus group was thinner than that in the CH group [(1.82±0.21) mm vs. (1.91±0.20) mm, P=0.047].
CONCLUSION
iRoot BP Plus used in pulpotomy can effectively preserve the living pulp and promote the development of root in the young permanent teeth with complex crown fracture.
Humans
;
Tooth Fractures
;
Calcium Hydroxide/therapeutic use*
;
Female
;
Male
;
Child
;
Pulp Capping and Pulpectomy Agents
;
Pulpotomy/methods*
;
Prospective Studies
;
Dental Pulp Capping/methods*
;
Adolescent
;
Dentition, Permanent
;
Drug Combinations
;
Tooth Crown/injuries*
;
Root Canal Filling Materials
;
Silicones
3.Embedded 3D printing of porous silicon orbital implants and its surface modification.
Hong ZHAO ; Yilin WANG ; Yanfang WANG ; Haihuan GONG ; Feiyang YINJUN ; Xiaojun CUI ; Jiankai ZHANG ; Wenhua HUANG
Journal of Southern Medical University 2023;43(5):783-792
OBJECTIVE:
To prepare customized porous silicone orbital implants using embedded 3D printing and assess the effect of surface modification on the properties of the implants.
METHODS:
The transparency, fluidity and rheological properties of the supporting media were tested to determine the optimal printing parameters of silicone. The morphological changes of silicone after modification were analyzed by scanning electron microscopy, and the hydrophilicity and hydrophobicity of silicone surface were evaluated by measuring the water contact angle. The compression modulus of porous silicone was measured using compression test. Porcine aortic endothelial cells (PAOECs) were co-cultured with porous silicone scaffolds for 1, 3 and 5 days to test the biocompatibility of silicone. The local inflammatory response to subcutaneous porous silicone implants was evaluated in rats.
RESULTS:
The optimal printing parameters of silicone orbital implants were determined as the following: supporting medium 4% (mass ratio), printing pressure 1.0 bar and printing speed 6 mm/s. Scanning electron microscopy showed that the silicone surface was successfully modified with polydopamine and collagen, which significantly improved hydrophilicity of the silicone surface (P < 0.05) without causing significant changes in the compression modulus (P > 0.05). The modified porous silicone scaffold had no obvious cytotoxicity and obviously promoted adhesion and proliferation of PAOECs (P < 0.05). In rats bearing the subcutaneous implants, no obvious inflammation was observed in the local tissue.
CONCLUSION
Poprous silicone orbital implants with uniform pores can be prepared using embedded 3D printing technology, and surface modification obviously improves hydrophilicity and biocompatibility of the silicone implants for potential clinical application.
Animals
;
Rats
;
Swine
;
Silicon
;
Orbital Implants
;
Endothelial Cells
;
Porosity
;
Silicones
;
Printing, Three-Dimensional
5.Retinal Toxicity Following the Injection Ganciclovir into Silicone Oil-filled Eye to Treat Acute Retinal Necrosis
Yeon Ji JO ; Seung Kwon CHOI ; Sun Ho PARK ; Jae Jung LEE ; Ji Eun LEE ; Sung Who PARK
Journal of the Korean Ophthalmological Society 2020;61(1):111-115
PURPOSE: To report a case of retinal toxicity after an intravitreal ganciclovir injection to treat acute retinal necrosis in an eye filled with silicone oil.CASE SUMMARY: A 56-year-old male presented with ocular pain and visual loss in his right eye. His best-corrected visual acuity was 20/25, inflammatory cells in the anterior chamber, multiple retinitis lesions and retinal vessel occlusions in the peripheral retina and vitreous opacity were showed. Acute retinal necrosis was suspected, anterior chamber polymerase chain reaction (PCR) test was done. Aciclovir 2,400 mg/day intravenously and ganciclovir 2.0 mg were administered by intravitreal injection. After 4 days, retinitis was worsened and PCR test was positive for varicella zoster virus. Ganciclovir intravitreal injections were increased twice a week. After 16 days, retinal detachment occurred, so scleral encircling, vitrectomy, laser photocoagulation, and silicone oil tamponade were conducted. Ganciclovir 1.0 mg was injected at the end of surgery. The patient's visual acuity decreased to hand motion, and multiple crystal deposits with multiple retinal hemorrhages were observed in the right eye the next day. Visual acuity did not recover and optical coherent tomography showed that the macula was thinned.CONCLUSIONS: Visual loss seemed to be related with the retinal toxicity of ganciclovir. The increased local concentration due to the silicone oil tamponade is thought to have caused the toxicity.
Acyclovir
;
Anterior Chamber
;
Ganciclovir
;
Hand
;
Herpesvirus 3, Human
;
Humans
;
Intravitreal Injections
;
Light Coagulation
;
Male
;
Middle Aged
;
Polymerase Chain Reaction
;
Retina
;
Retinal Detachment
;
Retinal Hemorrhage
;
Retinal Necrosis Syndrome, Acute
;
Retinal Vessels
;
Retinaldehyde
;
Retinitis
;
Silicon
;
Silicones
;
Visual Acuity
;
Vitrectomy
6.Analysis of subclinical infections and biofilm formation in cases of capsular contracture after silicone augmentation rhinoplasty: Prevalence and microbiological study
Supasid JIRAWATNOTAI ; Bhakabhob MAHACHITSATTAYA
Archives of Plastic Surgery 2019;46(2):160-166
BACKGROUND: Implant-related deformities in aesthetic rhinoplasty are a major problem for rhinoplasty surgeons. Capsular contracture is believed to be the pathological cause of delayed contour deformities, comparable to breast implant-related contracture. This study investigated the prevalence of bacterial biofilms and other epidemiological factors related to capsular contracture in cases of silicone augmentation rhinoplasty. METHODS: Thirty-three patients who underwent corrective rhinoplasty due to a delayed contour deformity or aesthetic revision after implant rhinoplasty were studied from December 2014 to December 2016. All recruited patients received surgical correction by the authors. The patients were categorized by clinical severity into four grades. Demographic data and related confounding factors were recorded. Samples of capsular tissue and silicone removed from each patient were analyzed for the presence of a biofilm by ultrasonication with bacterial culture and scanning electron microscopy. RESULTS: Thirty-three paired samples of capsular tissue and silicone implants from the study group were analyzed. Biofilms were detected in one of 10 subjects (10%) with grade 1 contracture, two of four (50%) with grade 2 contracture, 10 of 14 (71.40%) with grade 3 contracture, and four of five (80%) with grade 4 contracture (P<0.05). The organisms found were Staphylococcus epidermidis (47.10%), coagulase-negative staphylococci (35.30%), and Staphylococcus aureus (17.60%). CONCLUSIONS: As with breast implant-related capsular contracture, silicone nasal augmentation deformities likely result from bacterial biofilms. We demonstrated the prevalence of biofilms in patients with various degrees of contracture. Implant type and operative technique seemed to have only vague correlations with biofilm presence.
Asymptomatic Infections
;
Biofilms
;
Breast
;
Congenital Abnormalities
;
Contracture
;
Humans
;
Microscopy, Electron, Scanning
;
Prevalence
;
Rhinoplasty
;
Silicon
;
Silicones
;
Staphylococcus aureus
;
Staphylococcus epidermidis
;
Surgeons
7.A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures
Seong Hwan BAE ; Dae Kyun JEONG ; Ju Young GO ; Heeseung PARK ; Joo Hyoung KIM ; Jae Woo LEE ; Taewoo KANG
Archives of Plastic Surgery 2019;46(5):421-425
BACKGROUND: The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. METHODS: Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. RESULTS: Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. CONCLUSIONS: We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.
Endoscopy
;
Humans
;
Methods
;
Orbit
;
Polyethylene
;
Recurrence
;
Silicon
;
Silicones
;
Titanium
;
Tomography, X-Ray Computed
8.Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation
Du Hyeong LEE ; Hang Nga MAI ; Phyu Pwint THANT ; Su Hyung HONG ; Jaewon KIM ; Seung Mi JEONG ; Keun Woo LEE
The Journal of Advanced Prosthodontics 2019;11(1):41-47
PURPOSE: Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS: Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (α=.05). RESULTS: The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P < .001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION: Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.
Bacterial Adhesion
;
Biofilms
;
Dental Instruments
;
Dental Polishing
;
Diamond
;
Silicon
;
Silicones
;
Streptococcus mutans
9.Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques
Mugem Asli EKICI ; Ferhan EGILMEZ ; Isil CEKIC-NAGAS ; Gulfem ERGUN
The Journal of Advanced Prosthodontics 2019;11(2):128-137
PURPOSE: The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS: 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and Mann-Whitney U tests (P<.05). RESULTS: Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION: Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.
Absorption
;
Aluminum Oxide
;
Ceramics
;
Computer-Aided Design
;
Dental Polishing
;
Diamond
;
Immersion
;
Rubber
;
Silicon
;
Silicones
;
Solubility
;
Water
10.Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy
Hong Taek JUNG ; Shiela A CAMPANA ; Jin Hong PARK ; Joo Hee SHIN ; Jeong Yol LEE
The Journal of Korean Academy of Prosthodontics 2019;57(2):95-101
PURPOSE: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (µTBS) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. MATERIALS AND METHODS: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting (6 mm length × 1 mm width × 1 mm thick). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide (125 µm grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the µTBS test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (α = .05) using SPSS software. RESULTS: The mean µTBS of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. CONCLUSION: The µTBS of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the µTBS of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.
Adhesives
;
Alloys
;
Aluminum Oxide
;
Fungi
;
Resin Cements
;
Silicon
;
Silicones

Result Analysis
Print
Save