1.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
2.Three-dimensional binding treatment for avulsion fractures of inferior pole of patella utilizing suture anchor.
Hongqing HE ; Ningkai LI ; Meng LIU ; Jiating LIN ; Qiang WANG ; Yinchang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):26-31
OBJECTIVE:
To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.
METHODS:
A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B). There was no significant difference in terms of age, gender, cause of fracture, side of fracture, and disease duration between the two groups ( P>0.05). The length of incision, operation time, occurrence of complications, the range of motion of knee joint, and Böstman score of knee joint at last follow-up were recorded. The fracture healing was evaluated through X-ray films and the time of fracture healing was recorded.
RESULTS:
All incisions healed by first intention. The length of incision was significantly shorter in group A than in group B ( P<0.05). There was no significant difference in the operation time between the two groups ( P>0.05). All patients were followed up 12-24 months (mean, 16.1 months). X-ray films showed that all fractures healed and there was no significant difference in the healing time between the two groups ( P>0.05). At last follow-up, the range of motion and Böstman score of the knee joint in group A were significantly better than those in group B ( P<0.05). During follow-up, 1 patient (5.6%) in group A had one anchor mild prolapse and 3 patients (15.0%) occured internal fixation irritation in group B. But there was no significant difference in the incidence of complications between the two groups ( P>0.05).
CONCLUSION
For the avulsion fractures of the inferior pole of the patella, the suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique has advantages of reliable fixation, small incision, avoidance of secondary operation to remove internal fixator, and fewer complications, with definite effectiveness.
Humans
;
Male
;
Female
;
Patella/surgery*
;
Suture Anchors
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Retrospective Studies
;
Middle Aged
;
Fractures, Avulsion/surgery*
;
Treatment Outcome
;
Young Adult
;
Range of Motion, Articular
;
Fracture Healing
;
Adolescent
;
Suture Techniques
;
Knee Joint/physiopathology*
3.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*
4.Application of elbow skin fold extension line in extreme elbow flexion in ulnar Kirschner wire insertion of extended supracondylar humeral fractures in children.
Xu LIU ; Wei WU ; Yuzhou SHAN ; Guanghui YANG ; Ming CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):70-74
OBJECTIVE:
To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.
METHODS:
The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group). There was no significant difference in baseline data such as gender, age, side, cause of injury, Gartland type, Kirschner wire configuration, and time from injury to operation between the two groups ( P>0.05). The closed reduction rate, total operation time, time of medial humeral condyle pin placement, fluoroscopy times during medial pin placement, rate of one-time determination of medial entry point, ulnar nerve injury incidence, and fracture healing time were recorded and compared between the two groups. At the same time, the closed reduction rate of patients with the time from injury to operation ≤24 hours and >24 hours was compared. The elbow function was evaluated by Mayo elbow function score.
RESULTS:
The closed reduction rate of the study group was significantly higher than that of the control group ( P<0.05). Among all patients, the closed reduction rate of patients with the time from injury to operation ≤24 hours [73.3% (22/30)] was significantly higher than that of patients >24 hours [42.9% (12/28)] ( χ 2=5.545, P=0.019). The total operation time, medial needle placement time, and fluoroscopy times in the study group were significantly less than those in the control group, and the one-time determination rate of medial needle entry point in the study group was significantly higher than that in the control group ( P<0.05). There were 4 cases of ulnar nerve injury in the control group, and no ulnar nerve injury in the study group, but there was no significant difference in the incidence of ulnar nerve injury between the two groups ( P>0.05). All patients were followed up 6-12 months (mean, 8 months). There was no bone nonunion in both groups, and the fracture healing time of the study group was significantly shorter than that of the control group ( P<0.05). Volkmann ischemic contracture, heterotopic ossification, myositis ossificans, and premature epiphyseal closure were not observed after operation. No complications such as loosening or fracture of Kirschner wire occurred. At last follow-up, the Mayo elbow joint function score was used to evaluate function, and there was no significant difference between the two groups ( P>0.05).
CONCLUSION
In the treatment of extended supracondylar fractures of the humerus in children, the elbow skin fold extension line can help to quickly locate the medial epicondyle of the humerus, quickly insert Kirschner wire, and reduce the operation time and trauma.
Humans
;
Humeral Fractures/surgery*
;
Bone Wires
;
Male
;
Female
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Child
;
Elbow Joint/physiopathology*
;
Child, Preschool
;
Treatment Outcome
;
Fracture Healing
;
Ulnar Nerve/injuries*
;
Adolescent
;
Range of Motion, Articular
5.Effectiveness analysis of three internal fixation methods in treatment of avulsion fracture of tibial tubercle in adolescents.
Keyou DUAN ; Zhaodong WANG ; Yajun LIU ; Chen XU ; Zhonglian ZHU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):75-82
OBJECTIVE:
To analyze the effectiveness of three internal fixation methods, namely hollow screw combined with Kirschner wire tension band, hollow screw combined with anchor nail, and modified 1/3 tubular steel plate, in the treatment of avulsion fracture of tibial tubercle (AFTT) in adolescents.
METHODS:
Between January 2018 and September 2023, 19 adolescent AFTT patients who met the selection criteria were admitted. According to different internal fixation methods, patients were divided into group A (8 cases, hollow screw combined with Kirschner wire tension band), group B (6 cases, hollow screw combined with anchor nail), and group C (5 cases, modified 1/3 tubular steel plate). There was no significant difference in the baseline data of age, gender, side, cause of injury, Ogden classification, and time from injury to operation among the three groups ( P>0.05). The range of motion (ROM), weight-bearing time, normal activity time of knee joint, and the hospital for special surgery (HSS) score at last follow-up were recorded and compared among the three groups. Recorded whether the fracture was displaced, whether the fracture line was blurred at 1 month after operation, whether there was epiphyseal dysplasia, and whether there was incision infection and other complications.
RESULTS:
There was no significant difference in hospital stay between the groups ( P>0.05). All patients were followed up 10-24 months, with an average of 14.3 months; there was no significant difference between the groups ( P>0.05). All the incisions healed well without soft tissue irritation or fracture nonunion, and no limb shortening deformity or epiphyseal dysplasia was found during follow-up. At 1 month after operation, the knee joint ROM and hospitalization expenses in group A were better than those in groups B and C, the fracture healing time, knee joint weight-bearing time, and normal activity time of knee joint were better than those in group C, and the hospitalization expenses in group C were better than those in group B, with significant differences ( P<0.05); there was no significant difference in the other indicators between the groups ( P>0.05). In group A, the fracture line was blurred 1 month postoperatively, the fracture ends were in close contact, and there was no fracture displacement; in groups B and C, the fracture line was clear in 2 cases, and 1 case in group C had slight fracture displacement; except for 1 case in group B, there was no fracture split in the other two groups. There was no significant difference in the incidences of blur of fracture line, fracture displacement, and intraoperative bone split between the groups at 1 month after operation ( P>0.05). At last follow-up, the HSS scores of knee joints in the three groups were excellent and good, and there was no significant difference between the groups ( P>0.05).
CONCLUSION
Hollow screw combined with Kirschner wire tension band technique is effective in treating adolescent AFTT, which has the advantages of stabilizing fracture, accelerating fracture healing and rehabilitation, early feasible knee joint functional exercise, and reducing hospitalization expenses.
Humans
;
Tibial Fractures/surgery*
;
Adolescent
;
Male
;
Fracture Fixation, Internal/instrumentation*
;
Female
;
Fractures, Avulsion/surgery*
;
Bone Wires
;
Bone Screws
;
Bone Plates
;
Treatment Outcome
;
Range of Motion, Articular
;
Bone Nails
;
Weight-Bearing
;
Fracture Healing
6.Effectiveness of digital three-dimensional printing osteotomy guide plate assisted total knee arthroplasty in treatment of knee osteoarthritis patients with femoral internal implant.
Chao LI ; Binbin ZHANG ; Xiangping LIU ; Haiya LI ; Jingtang ZHANG ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):151-157
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) printing osteotomy guide plate assisted total knee arthroplasty (TKA) in treatment of knee osteoarthritis (KOA) patients with femoral internal implants.
METHODS:
The clinical data of 55 KOA patients who met the selection criteria between July 2021 and October 2023 were retrospectively analyzed. Among them, 26 cases combined with femoral implants were treated with digital 3D printing osteotomy guide plate assisted TKA (guide plate group), and 29 cases were treated with conventional TKA (control group). There was no significant difference in gender, age, body mass index, side, Kellgren-Lawrence classification, preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) knee score, knee range of motion, and other baseline data between the two groups ( P>0.05). The operation time, intraoperative blood loss, incision length, postoperative first ambulation time, surgical complications; VAS score, knee HSS score, knee range of motion before operation, at 1 week and 3 months after operation, and at last follow-up; distal femoral lateral angle, proximal tibial medial angle, hip-knee-ankle angle and other imaging indicators at last follow-up were recorded and compared between the two groups.
RESULTS:
The operation time, incision length, intraoperative blood loss, and postoperative first ambulation time in the guide plate group were significantly lower than those in the control group ( P<0.05). In the control group, there were 1 case of incision rupture and bleeding and 1 case of lower limb intermuscular venous thrombosis, which was cured after symptomatic treatment. There was no complication such as neurovascular injury, incision infection, or knee prosthesis loosening in both groups. Patients in both groups were followed up 12-26 months, with an average of 16.25 months. The VAS score, HSS score, and knee range of motion improved at each time point after operation in both groups, and further improved with time after operation, the differences were significant ( P<0.05). The above indicators in the guide plate group were significantly better than those in the control group at 1 week and 3 months after operation ( P<0.05), and there was no significant difference between the two groups at last follow-up ( P>0.05). At last follow-up, the distal femoral lateral angle, the proximal tibial medial angle, and the hip-knee-ankle angle in the guide plate group were significantly better than those in the control group ( P<0.05).
CONCLUSION
The application of digital 3D printing osteotomy guide plate assisted TKA in the treatment of KOA patients with femoral implants can simplify the surgical procedures, overcome limitations of conventional osteotomy guides, reduce surgical trauma, achieve individualized and precise osteotomy, and effectively restore lower limb alignment and knee joint function.
Humans
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/instrumentation*
;
Male
;
Retrospective Studies
;
Female
;
Printing, Three-Dimensional
;
Femur/surgery*
;
Middle Aged
;
Bone Plates
;
Range of Motion, Articular
;
Aged
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods*
;
Knee Prosthesis
;
Knee Joint/surgery*
;
Operative Time
7.Expert consensus on T 1 rhizotomy for central hand flexion spasticity (2024 version).
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):259-263
Central limb spasticity is a common complication after central nervous system injury, in which hand flexion spasticity often leads to the loss of the patient's ability to move. Reducing muscle tone and relieving spasticity are the prerequisites for restoring limb function. T 1 rhizotomy, which has been proposed in recent years, has proven to be effective in the treatment of central hand flexion spasticity. This consensus summarizes the etiology, symptoms, functional assessment of central hand flexion spasticity, and surgical indications for T 1 rhizotomy, surgical principles and procedures, and rehabilitation program. The standardized protocol of T 1 rhizotomy for the treatment of central hand flexion spasticity is proposed for the reference of clinicians in the process of diagnosis and treatment, with the aim of further improving the treatment level for central hand flexion spasticity.
Humans
;
Muscle Spasticity/physiopathology*
;
Rhizotomy/methods*
;
Hand/physiopathology*
;
Consensus
;
Treatment Outcome
;
Range of Motion, Articular
8.Clinical study of reverse total shoulder arthroplasty versus open reduction and internal plate fixation for treatment of Neer three/four-part proximal humeral fractures in elderly.
Yuhui YANG ; Zhantao DENG ; Qingtian LI ; Xiurui ZHANG ; Yunzhi PENG ; Ruiying ZHANG ; Yuanchen MA ; Qiujian ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):412-419
OBJECTIVE:
To compare the effectiveness and shoulder function of reverse total shoulder arthroplasty (RTSA) and open reduction and internal fixation (ORIF) in the treatment of Neer three/four-part proximal humeral fractures in the elderly.
METHODS:
Randomized controlled analysis was conducted on 68 patients over 70 years old with Neer three/four-part proximal humeral fractures treated with RTSA or ORIF between January 2020 and June 2022. The patients were randomly divided into RTSA group ( n=32) and ORIF group ( n=36). There was no significant difference ( P>0.05) in the baseline data such as age, gender, body mass index, injured side, Neer classification, and preoperative Charlson comorbidity index, visual analogue scale (VAS) score, Constant shoulder score, Oxford shoulder score (OSS), and hemoglobin (Hb). The operation time, intraoperative blood loss, reduction of Hb on the 3rd day after operation, hospital stay, total cost of hospitalization, complication incidence, range of motion of shoulder joint at 2 years after operation, VAS score before operation and at 5 days and 1 month after operation, Constant shoulder score and OSS score before operation and at 2 years after operation, and imaging results during follow-up were recorded and compared between the two groups.
RESULTS:
Compared with the ORIF group, the RTSA group had longer operation time, less intraoperative blood loss, and higher total cost of hospitalization ( P<0.05). There was no significant difference in Hb reduction on the 3rd day after operation between the two groups ( P>0.05). The VAS scores significantly improved in both groups at 5 days and 1 month after operation ( P<0.05), but there was no significant difference between the two groups ( P>0.05). All patients were followed up 26-35 months, with an average of 31.2 months. In the RTSA group, there were 2 cases of poor healing of superficial incision and 1 case of transient nerve injury. There was no complication such as bone resorption around the prosthesis, lucent band, prosthesis loosening, or periprosthetic fracture in all patients. In the ORIF group, there was 1 case of poor healing of superficial incision, 3 cases of nonunion of fracture, 1 case of arthritis secondary to humeral head necrosis, and 1 case of bone absorption of large tuberosity, and no displacement or fracture failure of internal fixation was found in all patients. There was no significant difference in the incidence of complications [9.4% (3/32) vs 16.7% (6/36)] between the two groups [ OR (95% CI): 0.828 (0.171, 4.014), P=0.814]. In the RTSA group, 28 cases were graded 0 and 4 cases were graded 1 at 2 years after operation. Constant and OSS scores of RTSA group were significantly better than those of ORIF group ( P<0.05). The Constant score was significantly better than ORIF group in activity and strength, range of motion, lifting, abduction, and external rotation ( P<0.05), and there was no significant difference in pain, daily function, and internal rotation between the two groups ( P>0.05). The RTSA group had a significantly greater range of motion in lifting, abduction, and external rotation than ORIF group ( P<0.05), but there was no significant difference in internal rotation between the two groups ( P>0.05).
CONCLUSION
Application of RTSA as the initial treatment of Neer three/four-part proximal humeral fractures in the elderly can achieve better rehabilitation of joint activity and lower risk of early reoperation, and improve the quality of life of elderly fracture patients. However, the difficulty of revision and the high cost of treatment require the surgeon to pay full attention and strictly grasp the indications.
Humans
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Shoulder Fractures/surgery*
;
Arthroplasty, Replacement, Shoulder/methods*
;
Aged
;
Bone Plates
;
Open Fracture Reduction/methods*
;
Range of Motion, Articular
;
Treatment Outcome
;
Shoulder Joint/physiopathology*
;
Aged, 80 and over
;
Operative Time
;
Postoperative Complications/epidemiology*
;
Length of Stay
9.Application of femoral condyle sliding osteotomy in initial total knee arthroplasty.
Xin WANG ; Jian MA ; Songyan ZHANG ; Rui TAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):425-433
OBJECTIVE:
To investigate the effect of femoral condyle sliding osteotomy (FCSO) on the flexion gap and external rotation of the prosthesis in balancing coronal instability during initial total knee arthroplasty (TKA).
METHODS:
Between November 2021 and October 2024, FCSO technique was applied to balance the coronal medial and lateral spaces during initial TKA in 3 patients, including medial condyle sliding osteotomy (MCSO) and lateral condyle sliding osteotomy (LCSO). There were 1 male and 2 females with the age of 81, 68, and 68 years old. The affected knee has varus or valgus deformity, with tibia-femoral angles of 169.7°, 203.3°, and 162.2°, respectively. The hip-knee-ankle angle (HKA), range of motion (ROM), knee society scoring system (KSS), and pain visual analogue scale (VAS) score were used to evaluate joint function and pain relief. Based on model bone, the thickness and bone bed area of the medial and lateral femoral condyle osteotomy blocks in FCSO were measured. During TKA in 12 patients, the range of osteotomy block movement was evaluated. By simplifying the upward and forward movement of the osteotomy block into a geometric model, the impact of movement on the flexion gap and external rotation of the prosthesis was calculated.
RESULTS:
After application of FCSO during TKA, the limb alignment and medial and lateral balance at extension and flexion positions were restored in 3 patients. Three patients were followed up 23, 11, and 3 months, respectively. Postoperative HKA, pain VAS score, KSS score, and ROM all showed significant improvement compared to preoperative levels. The maximum thickness of osteotomy blocks by MCSO and LCSO was 17 and 12 mm, respectively. The simple upward movement of the osteotomy block mainly affected the extension gap, and had little effect on the flexion gap and external rotation of the prosthesis. Moving the osteotomy block forward at the same time had a significant impact on the flexion gap and external rotation of the prosthesis, especially on LCSO. Mild forward movement leaded to a decrease in external rotation of more than 3°, which had a serious impact on the patellar trajectory.
CONCLUSION
FCSO can effectively solve the problem of imbalance between the medial and lateral spaces during initial TKA, avoiding knee joint instability caused by excessive loosening and limiting the use of constrained condylar prosthesis. The distance for the downward movement of the osteotomy block in MCSO and LCSO was 3-5 mm and 6-8 mm, respectively, with 10-15 mm of space for forward movement and almost no space for backward movement. For MCSO, the upward and forward movement of the osteotomy block will increase the external rotation of the prosthesis, which is beneficial for improving the patellar trajectory and suitable for valgus knee. LCSO is suitable for varus knee, and the osteotomy block only slides vertically up and down without moving forward and backward.
Humans
;
Osteotomy/methods*
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/methods*
;
Aged
;
Range of Motion, Articular
;
Femur/surgery*
;
Knee Joint/physiopathology*
;
Aged, 80 and over
;
Knee Prosthesis
;
Treatment Outcome
;
Osteoarthritis, Knee/surgery*
10.Modified Lemaire procedure in anterior cruciate ligament reconstruction with highly positive pivot shift test.
Shangzeng WANG ; Xinyan LIU ; Mingzhe SONG ; Bowen ZHENG ; Wenlong XU ; Shao CHENG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):434-439
OBJECTIVE:
To explore the effectiveness of the modified Lemaire procedure in anterior cruciate ligament reconstruction (ACLR) in patients with a highly positive pivot shift test.
METHODS:
The clinical data of 18 patients with anterior cruciate ligament (ACL) rupture and highly positive pivot shift test between April 2020 and September 2022 were retrospectively analyzed. There were 13 males and 5 females with an average age of 28.3 years (range, 17-41 years). Causes of injury included 11 cases of direct violence injury, including 6 cases of traffic accident injury, 4 cases of sports injury, 1 case of falling injury; 7 cases of indirect violence injury, all sports injury. All patients had complete ACL rupture, including 15 acute injuries and 3 old injuries. The preoperative pivot shift test was grade Ⅱ in 9 cases and grade Ⅲ in 9 cases. All patients were treated with ACLR combined with modified Lemaire procedure. The International Knee Documentation Committee (IKDC) score and Lysholm score were used to evaluate the effectiveness before operation and at 3, 6, 12 months after operation. KT-2000 arthrometer was used to measure the anterior stability of the knee joint, and the difference between the healthy and affected sides was recorded. Pivot shift test was used to evaluate the rotational stability of the knee joint. During the follow-up, X-ray films were taken to observe the bone tunnel and internal fixation, and MRI was used to examine the healing of ACL, anterolateral collateral ligament and fibular collateral ligament grafts.
RESULTS:
All patients completed the operation successfully without complications such as knee joint infection, vascular and nerve injury. All patients were followed up 12-19 months (mean, 13.2 months). After operation, the rotational stability of the knee joint recovered satisfactorily, and there was no adverse symptom such as knee instability and locking at last follow-up. X-ray film and MRI showed that the bone tunnel was anatomically located and healed well, the internal fixation was in good position, and the reconstructed ACL and iliotibial band were continuous and in good tension. The IKDC score, Lysholm score, and the difference of KT-2000 between the healthy and the affected sides significantly improved at 3, 6, and 12 months after operation ( P<0.05). All the indicators further improved with time after operation, except that there was no significant difference in IKDC score between 3 and 6 months after operation and in the difference of KT-2000 between 3 months and 6, 12 months after operation ( P>0.05), and there were significant differences in other indicators between different time points ( P<0.05). Pivot shift test was negative immediately after operation and at last follow-up.
CONCLUSION
In ACL injuries with a highly positive pivot shift test, ACLR combined with the modified Lemaire procedure can effectively restore anterolateral knee stability, leading to satisfactory knee stability and function in the early postoperative period.
Humans
;
Anterior Cruciate Ligament Reconstruction/methods*
;
Male
;
Female
;
Anterior Cruciate Ligament Injuries/physiopathology*
;
Adult
;
Adolescent
;
Retrospective Studies
;
Young Adult
;
Anterior Cruciate Ligament/surgery*
;
Treatment Outcome
;
Joint Instability/surgery*
;
Knee Joint/physiopathology*
;
Range of Motion, Articular

Result Analysis
Print
Save
E-mail